Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 Westcor Division 408-522-5280 LoPAC Family Rev. 1.2 Page 3 of 8
Set your site on VICOR at www.vicorpower.com
INPUT CHARACTERISTICS
Parameter PFC Mini PFC Micro PFC MicroS Units Notes
AC Input
Voltage 85-264 Vac
Frequency 47-500 Hz
DC Input 100-380 100-300 Vdc
Line Regulation 0.4 % From low line to high line
Inrush Current
@ 115Vac 30 5 A rms
@ 230Vac 60 10 A rms
Ride Through Time >20 ms
@ load 1,200 500 W
Conducted EMI/RFI FCC Class A FCC Class A PFC Mini with 1st Gen units
EN55022 Class A EN55022 Class A (consult factory) meets FCC & EN Class B
Power Factor >0.98 >75% load
Harmonic Current Limits EN61000-3-2/A14 Class A
Surge Immunity IEC61000-4-5 Level 3 Performance Criteria B
Dielectric Withstand
Primary to Chassis GND 2,121 Vdc
Primary to Secondary 4,242 Vdc
Secondary to Chassis GND 750 Vdc
OUTPUT CHARACTERISTICS
Parameter PFC Mini PFC Micro PFC MicroS Units Notes
Setpoint Accuracy 0.5 % of Vnom
Load Regulation 0.05 % 10% to full load
0.2 % No load to full load
Temperature Regulation 0.005 %/°C -20º to +65ºC
Long T erm Drift 0.02 %/khr
Output Ripple & Noise
≤10Vout 100 mV 20 MHz bandwidth
>10Vout 1.0 % Vout 20 MHz bandwidth
V oltage Trim Range
1st Gen Slots 50-110 % Vout ±10% on 10-15 Vout
2nd Gen Slots 10-110 % Vout Preload may be required
Remote Sense Compensation 0.5 Vdc Autosense (See page 2)
OVP Set Point 125 % Vout Not available on 1st Gen Minis
Current Limit 115 % Imax Auto recovery
ENVIRONMENTAL CHARACTERISTICS
Parameter PFC Mini PFC Micro PFC MicroS Units Notes
Storage Temperature -40 to +85 °C
Operating Temperature
Full Rated Power -20 to +45 °C
50% Rated Power -20 to +65 °C
Safety Approvals UL, CUL, TÜV, VDE, CE Marked
MECHANICAL CHARACTERISTICS
Parameter PFC Mini PFC Micro PFC MicroS Units Notes
Weight 5.5 5.2 3.1 lbs
2,5 2,4 1,4 kg
Overall Dimensions 12.20 x 6.00 x 1.75 10.40 x 5.06 x 1.86 7.95 x 5.06 x 1.86 in L x W x H
309,9 x 152,4 x 44,5 264,1 x 128,5 x 47,3 201,9 x 128,5 x 47,3 mm
Performance Specifications
The following are typical performance specifications at room
ambient temperature, nominal line voltage (115/230Vac) and
75% load on all outputs, unless specified otherwise. For detail
specifications, consult the Design Guide for the LoPAC
configuration of interest. This is available from any sales office
(see Back Cover) or our web site (vicorpower.com).