VICOR PM12-75300, PM12-100300, PM12-150600, PM12-200600, PM15-100300 Datasheet

...
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 Westcor Division 408-522-5280 LoPAC Family Rev. 1.2 Page 1 of 8
Set your site on VICOR at www.vicorpower.com
Family Features
• Near unity power factor
• EN61000-3-2 harmonic current compliance
• Low profile package
• Output power to 1,500W
• Up to 6 user specifiable outputs
• Power density up to 11W/in
3
• Integral cooling fans
• New “Autosense” feature
• Safety agency approvals: UL, CUL, TÜV, VDE, CE Marked
Overview
The PFC MicroS, PFC Micro and PFC Mini are members of the new low profile, high-density LoPAC series of power factor corrected AC-DC power supplies. Available as a one, two or three slot package, respectively, each LoPAC slot can be configured with standard Vicor DC-DC converter modules enabling up to six user specifiable isolated outputs in a package only
1.75'' (44.5mm) high with a power density
of 11W/in3.
For maximum versatility and flexibility, the LoPAC can be configured with Vicor 1st Generation VI-26x (full brick), VI-J6x (half brick) or 2nd Generation V375 Series full, half and quarter brick modules. These modules cover the entire range of outputs from 1 to 100Vdc and 25 to 600 Watts. We will factory configure the optimum solution based on your exact requirements.
All units comply with FCC Class Aand certain configurations meet FCC & EN55022 Class B for conducted EMI. Harmonic current limits per EN61000-3-2 and Surge Immunity per IEC61000-4-5 Level 3, in addition to a wide variety of safety agency approvals, further enhance the LoPAC flexibility.
Data Sheet
LoPAC
TM
Family
PFC Mini, PFC Micro, PFC MicroS
Power Factor Corrected, AC-DC Switchers
PFC Mini
12.20" x 6.00" x 1.75"
309,9 x 152,4 x 44,5 mm
Up to 1,500W 1 to 6 Outputs
PFC Micro
10.40" x 5.06" x 1.86"
264,1 x 128,5 x 47,3 mm
Up to 800W
1 to 6 Outputs
PFC MicroS
7.95" x 5.06" x 1.86"
201,9 x 128,5 x 47,3 mm
Up to 600W
1 to 3 Outputs
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 Westcor Division 408-522-5280 LoPAC Family Rev. 1.2 Page 2 of 8
Set your site on VICOR at www.vicorpower.com
Autosense Feature
*
This is a new feature implemented in all converter slots in the LoPAC family. If remote sense connections are not needed or are inadvertently not made, no local sense connections are necessary. Simply connect the output(s) to the load and the
converter(s) will automatically operate in the local sense mode. If remote sense connections are made, the unit will operate in remote sense mode.
Part Numbering
Product Prefix
PM PFC Mini PC PFC Micro PS PFC MicroS
Number of
1st Gen module(s)
Number of
2nd Gen module(s)
Factory
Assigned
P M X
1
-X
2
X
3
XXX
Number of
Output
Voltages
Available Power (W) per Package Size
Maxi Mini Micro
2nd Gen 1st Gen 2nd Gen 1st Gen 2nd Gen
2Vdc 160 80 60 100 40 30 50
3.3Vdc 264 132 99 150 66 50 75 5Vdc 400 200 150 200 100 75 100
12Vdc 600 200 150 300 100 75 150 15Vdc 600 200 150 300 100 75 150 24Vdc 600 200 150 300 100 75 150 28Vdc 600 200 150 300 100 75 150 48Vdc 600 200 150 300 100 75 150
Maximum Output Power
Model Total per
Type # Slots @ 230Vac @ 115Vac Slot Modules per Slot
PFC Mini 3 1,500W 800W 500W 1 Maxi or 2 Minis
PFC Micro 2 800W 500W 600W 1 Maxi or 2 Minis or 3 Micros
PFC MicroS 1 600W 500W 600W 1 Maxi or 2 Minis or 3 Micros
Output
Voltage
LoPAC Slot Configurations
The DC-DC converter modules are used to populate each LoPAC converter slot. Each slot can be configured in different ways depending on module sizes and power limitations.
The following table summarizes the available slot configurations for each of the three LoPAC packages.
DC Output Selections
The versatility of the LoPAC series is due, in large part, to the wide array of Vicor modules available to be configured into the different package formats. Slots can be populated with 1st or 2nd Generation modules in full, half or quarter brick sizes. Vicor’s full VI-26x, VI-J6x and V375 standard product
matrices are available to choose from. In addition, the full range of non-standard voltages and powers from 1 to 100Vdc and 10 to 600W is also available for inclusion. The table below is just a sampling of some of the most popular standard outputs that can be configured into LoPAC slots.
*
Applies to converter slots utilizing Maxi or Mini size converters.
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 Westcor Division 408-522-5280 LoPAC Family Rev. 1.2 Page 3 of 8
Set your site on VICOR at www.vicorpower.com
INPUT CHARACTERISTICS Parameter PFC Mini PFC Micro PFC MicroS Units Notes
AC Input
Voltage 85-264 Vac
Frequency 47-500 Hz DC Input 100-380 100-300 Vdc Line Regulation 0.4 % From low line to high line Inrush Current
@ 115Vac 30 5 A rms
@ 230Vac 60 10 A rms Ride Through Time >20 ms
@ load 1,200 500 W Conducted EMI/RFI FCC Class A FCC Class A PFC Mini with 1st Gen units
EN55022 Class A EN55022 Class A (consult factory) meets FCC & EN Class B Power Factor >0.98 >75% load Harmonic Current Limits EN61000-3-2/A14 Class A Surge Immunity IEC61000-4-5 Level 3 Performance Criteria B Dielectric Withstand
Primary to Chassis GND 2,121 Vdc Primary to Secondary 4,242 Vdc Secondary to Chassis GND 750 Vdc
OUTPUT CHARACTERISTICS Parameter PFC Mini PFC Micro PFC MicroS Units Notes
Setpoint Accuracy 0.5 % of Vnom Load Regulation 0.05 % 10% to full load
0.2 % No load to full load Temperature Regulation 0.005 %/°C -20º to +65ºC Long T erm Drift 0.02 %/khr Output Ripple & Noise
10Vout 100 mV 20 MHz bandwidth >10Vout 1.0 % Vout 20 MHz bandwidth
V oltage Trim Range
1st Gen Slots 50-110 % Vout ±10% on 10-15 Vout
2nd Gen Slots 10-110 % Vout Preload may be required Remote Sense Compensation 0.5 Vdc Autosense (See page 2) OVP Set Point 125 % Vout Not available on 1st Gen Minis Current Limit 115 % Imax Auto recovery
ENVIRONMENTAL CHARACTERISTICS Parameter PFC Mini PFC Micro PFC MicroS Units Notes
Storage Temperature -40 to +85 °C Operating Temperature
Full Rated Power -20 to +45 °C
50% Rated Power -20 to +65 °C Safety Approvals UL, CUL, TÜV, VDE, CE Marked
MECHANICAL CHARACTERISTICS Parameter PFC Mini PFC Micro PFC MicroS Units Notes
Weight 5.5 5.2 3.1 lbs
2,5 2,4 1,4 kg
Overall Dimensions 12.20 x 6.00 x 1.75 10.40 x 5.06 x 1.86 7.95 x 5.06 x 1.86 in L x W x H
309,9 x 152,4 x 44,5 264,1 x 128,5 x 47,3 201,9 x 128,5 x 47,3 mm
Performance Specifications
The following are typical performance specifications at room ambient temperature, nominal line voltage (115/230Vac) and 75% load on all outputs, unless specified otherwise. For detail
specifications, consult the Design Guide for the LoPAC configuration of interest. This is available from any sales office (see Back Cover) or our web site (vicorpower.com).
Loading...
+ 5 hidden pages