Parameter Min Typ Max Remarks
Input voltage 180Vdc 270Vdc 375Vdc Continuous Output current 3A Inrush limiting 0.018A/µF Transient immunity Exceeds limits of MIL-STD-704E EMI:MIL-STD-461E
Dielectric withstand 1,500Vrms Input/Output to base
2,121Vdc Input/Output to base Efficiency 96% 98% Internal voltage drop 3.0Vdc 5.0Vdc @ 3A, 100°C baseplate ON/OFF control
Enable (ON) 0.0Vdc 1.0Vdc Referenced to –Vout. Disable (OFF) 3.5Vdc 5.0Vdc 100kinternal pull-up resistor
External capacitance See illustration C1 on page 3.
10µF 22µF 400V Weight 3.1 (88) 4 (113) Ounces (grams) Warranty 2 Years
Parameter Rating Unit Notes
+In to –In 375 Vdc Continuous +In to –In 400 Vdc 100ms Mounting torque 5 (0.57) in-lbs 6 each, #4-40 or M3 Pin Soldering temperature 500 (260) °F (°C) <5 sec; wave solder Pin Soldering temperature 750 (390) °F (°C) <7 sec; hand solder Operating temperature H–Grade -40 to +100 °C Baseplate Storage temperature H–Grade -55 to +125 °C Operating temperature M–Grade -55 to +100 °C Baseplate Storage temperature M–Grade -65 to +125 °C
Features
EMI filtering-MIL-STD-461E
Transient protection-MIL-STD-704E
Environments-MIL-STD-810, MIL-STD-202
Environmental stress screening
Low profile mounting options
Output current up to 3 Amps
Mini sized package
Inrush current limiting
Product Highlights
The M-FIAM3 is a DC front-end module that provides EMI filtering and transient protection required in military applications. The M-FIAM3 enables designers using Vicor 2nd Generation 300V DC-DC converters to meet conducted emission/conducted susceptibility per MIL-STD-461E; and input transients per MIL-STD-704E. The M-FIAM3 accepts an input voltage of 180-375Vdc and delivers output current up to 3 Amps.
M-FIAM3 is housed in an industry standard "half brick" module measuring
2.28" x 2.2" x 0.5" and depending upon model selected, may be mounted on-board or in-board for height critical applications.
Compatible Products
• 2nd Generation 300V Input DC-DC converters
Part Number Format
*Compatible with SurfMate and InMate socketing systems.
Thermal Resistance
Parameter Typ
Baseplate to sink; flat, greased surface 0.16°C/Watt Baseplate to sink; thermal pad (P/N 20264) 0.1°C/Watt Baseplate to ambient 7.9°C/Watt Baseplate to sink; 1000 LFM 2.2°C/Watt
M-FIAM3
Military 270Vin Filter Input Attenuator Module
45
Shown actual size:
2.28 x 2.2 x 0.5 in
57,9 x 55,9 x 12,7 mm
Specifications
(typical at TBP = 25ºC, nominal line, 75% load, unless otherwise specified)
Absolute Maximum Rating
M-FIAM3 M 2 1
Product
Baseplate 1 = Slotted 2 = Threaded 3 = Thru-hole
Pin Style 1 = Short 2 = Long
*S=Short ModuMate *N=Long ModuMate
Product Grade(°C)
H = –40 to +100 M = –55 to +100
Temp. Environment MTBF Unit
25°C Ground benign:G.B. 3,505,003 Hrs 50°C Naval sheltered:N.S. 841,200 Hrs
65°C Airborne inhabited cargo:A.I.C. 683,475 Hrs
MTBF per MIL-HDBK-217F
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 MFIAM3 Rev. 1.5 Page 2 of 4
Set your site on VICOR at www.vicorpower.com
Transient Immunity
Inrush Limiting
Figure 2 – Transient Immunity: M-FIAM3 output response to an input transient.
Figure 3– Inrush Limiting: Inrush current with 22µF external capacitance.
Environmental Qualification
Altitude
MIL-STD-810C, Method 500.2, Procedure I & II, 40,000 ft. and 70,000 ft. Operational.
Explosive Atmosphere
MIL-STD-810F, Method 511.4, Procedure I, Operational.
Vibration
MIL-STD-810F, Method 514.5, Procedure I, Category 14, Sine and Random vibration per Table 514.5C for Helicopter AH-6J Main Rotor with overall level of 5.6 grams for 4 hours per axis. MIL-STD-810F, Method 514.5C, General Minimum Integrity Curve per Figure 514.5C-17 with overall level of 7.7 grams for 1 hour per axis.
Shock
MIL-STD-810-F, Method 516.5, Procedure I, Functional Shock,40 G's. MIL-S-901D, Lightweight Hammer Shock, 3 impacts/axis, 1,3,5 ft. MIL-STD-202F, Method 213B, 60 G's, 9ms half sine. MIL-STD-202F, Method 213B, 75 G's, 11ms Saw Tooth Shock.
Acceleration
MIL-STD-810F, Method 513.5, Procedure II, table 513.5-II, Operational, 2-7 G's, 6 directions.
Humidity
MIL-STD-810F, Method 507.4, Procedure I, Cycle I, 240 hrs, 95% RH.
Solder Test
MIL-STD-202F, Method 208, 8 hour aging.
H Grade M Grade
Operating Temp. -40°C to +100°C -55°C to +100°C Storage Temp. -55°C to +125°C -65°C to +125°C
Temp. Cycling:*
12 cycles 12 cycles
-65°C to +100°C -65°C to +100°C Ambient Test @ 25°C
Yes Yes
Power Cycling 12 hours, 24 hours, Burn-In: 28 cycles 56 cycles Functional and Parametric
-40°C and -55°C and
ATE Tests:
+100°C +100°C
Hi-Pot Test Yes Yes Visual Inspection: Yes Yes Test Data vicorpower.com vicorpower.com
Environmental Stress Screening
Conducted Noise
Figure 1– M-FIAM3 and Model V300A48M500AL DC-DC converter operating at 180Vdc, 130W.
Output
Input
*Temperature cycled with power off, 17°C per minute rate of change.
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 MFIAM3 Rev. 1.5 Page 3 of 4
Set your site on VICOR at www.vicorpower.com
(2X)
0.01
0.35 8,8
0.20** 5,1
0.12* 3,1
DIA,(7X)
0.150 3,81
(REF)
DIA,(2X)
0.080
2,03
431
98276 5
0.23 5,8
0.400
10,16
1.400 35,56
1.000 25,40
0.700 17,78
2.20 55,9
1.74 44,2
FULL R (6X)
(6X)
(REF.)
0.10 2,5
1.30 33,0
2.28 57,9
2.20 55,9
0.130
3,30
0.49 12,4
0.65 16,5
0.06 1,5
R(3X)
X 45˚
CHAMFER
Use a 4-40 Screw (6X)
Torque to:
5 in-lbs
.57 N-m
0.54 13,7
0.43 10,9
Pin Style 2&N
(Long Pin)
0.62 15,7
Pin Style 1&S
(Short Pin)
(9X)
(9X)
Slotted (Style 1) or Threaded (Style 2)
4-40 UNC-2B (6X)
or Thru Hole (Style 3)
#30 Drill Thru (6X) (0.1285)
(ALL MARKINGS
THIS SURFACE)
ALUMINUM BASEPLATE
0.50 ±0.02 12,7 ±0,5
* Style 1 baseplate only ** Style 2 & 3 baseplates *** Reserved for Vicor accessories Not for mounting
style 2 & 3 baseplates only (4X)***
0.300 ±0.015 7,62 ±0,38
0.300 ±0.015 7,62 ±0,38
1.900 48,26
2.000
50,80
0.10 2,5
PCB Mounting Specifications
Transient and Surge Protection
Module Pins
No. Function Label
1 +In + 2
No
NC
Connection 3 Ground EMI/GND 4–In – 5–Out – 6 ON/OFF ON/OFF
7
No
NC
Connection 8
No
NC
Connection 9 +Out +
Mechanical Diagram
C1
Capacitance (C1) 10µF(min),22µF(max)
Recommended Fuse: 3A Max., F03A Type
Note: The M-FIAM3 is shown in the on state. To disable,
open the connection between ON/OFF and –Out.
–IN
MOV P/N
03040
+IN
EMI
GND
NC
++
M-FIAM3
OFF
ON
NC NC
–IN
PR
2nd Generation
PC
300Vdc Input
DC-DC Converters
+IN
–OUT
–S
SC
+S
+OUT
INBOARD
SOLDER
MOUNT
PIN STYLE 1&S
0.094 ±0.003
(7X)
2,39 ±0,08
0.164 ±0.003
(2X)
4,16 ±0,08
0.43 10,9
PCB THICKNESS
0.06
R (4X)
1,5
1.900*
1.900*
48.26
48,26
0.400* 10,16
0.195 4,95
0.062 ±0.010 1,57 ±0,25
1.790 45,47
1.400* 35,56
56789
12 34
0.700* 17,78
1.000* 25,40
THRU HOLE
* DENOTES TOL =
PLATED
DIA
1.584*
±0.003
40,23
±0,08
0.158 4,01
ONBOARD
SOLDER
MOUNT
PIN STYLE 2&N
0.094 ±0.003 2,39 ±0,08
0.164 ±0.003 4,16 ±0,08
0.53 13,5
ALUMINUM BASEPLATE
PINS STYLES STYLE 1 & 2: TIN/LEAD HOT SOLDER DIPPED STYLE S & N: GOLD PLATED COPPER
ALL MARKINGS THIS SURFACE
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 FARM, Filter/Autoranging Rectifier Module Rev. 1.5 04/03/10M
Set your site on VICOR at www.vicorpower.com
Vicor’s comprehensive line of power solutions includes modular, high density DC-DC converters and accessory components, configurable power supplies, and custom power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. No license is granted by implication or otherwise under any patent or patent rights of Vicor. Vicor components are not designed to be used in applications, such as life support systems, wherein a failure or malfunction could result in injury or death. All sales are subject to Vicor’s Terms and Conditions of Sale, which are available upon request.
Specifications are subject to change without notice.
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
978-470-2900
Fax: 978-475-6715
Email
Vicor Express: vicorexp@vicr.com Technical Support: apps@vicr.com
Component Solutions for Your Power System
Loading...