VICOR M-FIAM3M21, M-FIAM3M13, M-FIAM3M11, M-FIAM3HS2, M-FIAM3HS1 Datasheet

...
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 MFIAM3 Rev. 1.5 Page 1 of 4
Set your site on VICOR at www.vicorpower.com
Parameter Min Typ Max Remarks
Input voltage 180Vdc 270Vdc 375Vdc Continuous Output current 3A Inrush limiting 0.018A/µF Transient immunity Exceeds limits of MIL-STD-704E EMI:MIL-STD-461E
Dielectric withstand 1,500Vrms Input/Output to base
2,121Vdc Input/Output to base Efficiency 96% 98% Internal voltage drop 3.0Vdc 5.0Vdc @ 3A, 100°C baseplate ON/OFF control
Enable (ON) 0.0Vdc 1.0Vdc Referenced to –Vout. Disable (OFF) 3.5Vdc 5.0Vdc 100kinternal pull-up resistor
External capacitance See illustration C1 on page 3.
10µF 22µF 400V Weight 3.1 (88) 4 (113) Ounces (grams) Warranty 2 Years
Parameter Rating Unit Notes
+In to –In 375 Vdc Continuous +In to –In 400 Vdc 100ms Mounting torque 5 (0.57) in-lbs 6 each, #4-40 or M3 Pin Soldering temperature 500 (260) °F (°C) <5 sec; wave solder Pin Soldering temperature 750 (390) °F (°C) <7 sec; hand solder Operating temperature H–Grade -40 to +100 °C Baseplate Storage temperature H–Grade -55 to +125 °C Operating temperature M–Grade -55 to +100 °C Baseplate Storage temperature M–Grade -65 to +125 °C
Features
EMI filtering-MIL-STD-461E
Transient protection-MIL-STD-704E
Environments-MIL-STD-810, MIL-STD-202
Environmental stress screening
Low profile mounting options
Output current up to 3 Amps
Mini sized package
Inrush current limiting
Product Highlights
The M-FIAM3 is a DC front-end module that provides EMI filtering and transient protection required in military applications. The M-FIAM3 enables designers using Vicor 2nd Generation 300V DC-DC converters to meet conducted emission/conducted susceptibility per MIL-STD-461E; and input transients per MIL-STD-704E. The M-FIAM3 accepts an input voltage of 180-375Vdc and delivers output current up to 3 Amps.
M-FIAM3 is housed in an industry standard "half brick" module measuring
2.28" x 2.2" x 0.5" and depending upon model selected, may be mounted on-board or in-board for height critical applications.
Compatible Products
• 2nd Generation 300V Input DC-DC converters
Part Number Format
*Compatible with SurfMate and InMate socketing systems.
Thermal Resistance
Parameter Typ
Baseplate to sink; flat, greased surface 0.16°C/Watt Baseplate to sink; thermal pad (P/N 20264) 0.1°C/Watt Baseplate to ambient 7.9°C/Watt Baseplate to sink; 1000 LFM 2.2°C/Watt
M-FIAM3
Military 270Vin Filter Input Attenuator Module
45
Shown actual size:
2.28 x 2.2 x 0.5 in
57,9 x 55,9 x 12,7 mm
Specifications
(typical at TBP = 25ºC, nominal line, 75% load, unless otherwise specified)
Absolute Maximum Rating
M-FIAM3 M 2 1
Product
Baseplate 1 = Slotted 2 = Threaded 3 = Thru-hole
Pin Style 1 = Short 2 = Long
*S=Short ModuMate *N=Long ModuMate
Product Grade(°C)
H = –40 to +100 M = –55 to +100
Temp. Environment MTBF Unit
25°C Ground benign:G.B. 3,505,003 Hrs 50°C Naval sheltered:N.S. 841,200 Hrs
65°C Airborne inhabited cargo:A.I.C. 683,475 Hrs
MTBF per MIL-HDBK-217F
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 MFIAM3 Rev. 1.5 Page 2 of 4
Set your site on VICOR at www.vicorpower.com
Transient Immunity
Inrush Limiting
Figure 2 – Transient Immunity: M-FIAM3 output response to an input transient.
Figure 3– Inrush Limiting: Inrush current with 22µF external capacitance.
Environmental Qualification
Altitude
MIL-STD-810C, Method 500.2, Procedure I & II, 40,000 ft. and 70,000 ft. Operational.
Explosive Atmosphere
MIL-STD-810F, Method 511.4, Procedure I, Operational.
Vibration
MIL-STD-810F, Method 514.5, Procedure I, Category 14, Sine and Random vibration per Table 514.5C for Helicopter AH-6J Main Rotor with overall level of 5.6 grams for 4 hours per axis. MIL-STD-810F, Method 514.5C, General Minimum Integrity Curve per Figure 514.5C-17 with overall level of 7.7 grams for 1 hour per axis.
Shock
MIL-STD-810-F, Method 516.5, Procedure I, Functional Shock,40 G's. MIL-S-901D, Lightweight Hammer Shock, 3 impacts/axis, 1,3,5 ft. MIL-STD-202F, Method 213B, 60 G's, 9ms half sine. MIL-STD-202F, Method 213B, 75 G's, 11ms Saw Tooth Shock.
Acceleration
MIL-STD-810F, Method 513.5, Procedure II, table 513.5-II, Operational, 2-7 G's, 6 directions.
Humidity
MIL-STD-810F, Method 507.4, Procedure I, Cycle I, 240 hrs, 95% RH.
Solder Test
MIL-STD-202F, Method 208, 8 hour aging.
H Grade M Grade
Operating Temp. -40°C to +100°C -55°C to +100°C Storage Temp. -55°C to +125°C -65°C to +125°C
Temp. Cycling:*
12 cycles 12 cycles
-65°C to +100°C -65°C to +100°C Ambient Test @ 25°C
Yes Yes
Power Cycling 12 hours, 24 hours, Burn-In: 28 cycles 56 cycles Functional and Parametric
-40°C and -55°C and
ATE Tests:
+100°C +100°C
Hi-Pot Test Yes Yes Visual Inspection: Yes Yes Test Data vicorpower.com vicorpower.com
Environmental Stress Screening
Conducted Noise
Figure 1– M-FIAM3 and Model V300A48M500AL DC-DC converter operating at 180Vdc, 130W.
Output
Input
*Temperature cycled with power off, 17°C per minute rate of change.
Loading...