VICOR FIAM2C11, FIAM1T23, FIAM1T231, FIAM1T22, FIAM1T13 Datasheet

...
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 FIAM, Filter Input Attenuator Module Rev. 1.1 Page 1 of 4
Set your site on VICOR at www.vicorpower.com
PRELIMINARY
Parameter Min Typ Max Remarks
Input voltage 36Vdc 48Vdc 76Vdc Continuous Output current
FIAM1xxx 10A
FIAM2xxx 20A Inrush limiting .014A/µF Transient immunity 1µsec duration
Bellcore TR-NWT-000499 200V 5.0µsec rise time, 50µsec duration surge
ETS 300 386-1 Class 2 200V 1-100nsec burst
250V
EMI When used with Vicor 2nd Generation
Bellcore GR-001089-Core Issue 2 48Vin DC-DC converters
EN 55022 Level B
FCC Part 15 Level B Dielectric withstand 1,500Vrms Input/Output to Base
2,121Vdc Input/Output to Base
Efficiency 96 97.5 Internal voltage drop is 1.4 max.
@ 20A, 100°C baseplate
Reverse polarity protection No damage to module,
external fuse required
ON/OFF control
Enable (ON) 0.0Vdc 1.0Vdc Referenced to –Vout.
Disable (OFF) 3.5Vdc 5.0Vdc 100kinternal pull-up resistor External capacitance See illustration on page 2.
FIAM1xxx 10µF 150µF 100V
FIAM2xxx 100µF 330µF 100V Safety approvals UL 1950, CSA 22.2-950, EN 60950 Weight 3.1 (88) 4 (113) ounces (grams) Warranty 2 years
Parameter Rating Unit Notes
+In to –In 80 Vdc Continuous +In to –In 100 V 100ms +Out to –Out 75 Vdc Continuous Mounting torque 5(0.57) in-lbs 6 each, #4-40 or M3 Pin Soldering temperature 500 (260) °F(°C) <5 sec; wave solder Pin Soldering temperature 750 (390) °F(°C) <7 sec; hand solder Storage temperature C–, T–Grade -40 to +125 °C Operating temperature C–Grade -20 to +100 °C Baseplate Operating temperature T–Grade -40 to +100 °C Baseplate
Features
EMI filtering-Class B
Transient protection
Low profile mounting options
10 and 20 Ampere versions
UL, CSA, EN compliance
Mini-size package
Inrush current limiting
Product Highlights
The FIAM is a DC front-end module providing transient protection, inrush current limiting and Class B EMI filtering in a Mini­size package. The FIAM enables designers using Vicor 2nd Generation, 48Vin DC-DC converters to meet the transient immunity and EMI requirements of Bellcore, FCC, ETSI and European Norms while protecting system hardware from inrush current. The FIAM accepts an input voltage of 36-76Vdc, is available in 10 or 20A versions and provides reverse polarity protection and remote on/off.
FIAM is housed in an industry standard "half brick" module measuring 2.28" x 2.2" x 0.5" and depending upon model selected, may be mounted on-board or in-board for height critical applications.
Compatible Products
• 2nd Generation 48V Input DC-DC converters
Part Number Format
Thermal Resistance
Parameter Typ
Baseplate to sink; flat, greased surface 0.16°C/Watt Baseplate to sink; thermal pad (P/N 20264) 0.1°C/Watt Baseplate to ambient 7.9°C/Watt Baseplate to sink; 1000 LFM 2.2°C/Watt
Data Sheet
FIAM
TM
Filter Input Attenuator Module
45
Shown actual size:
2.28 x 2.2 x 0.5 in
57,9 x 55,9 x 12,7 mm
Specifications
(typical at TBP = 25C, nominal line, 75% load, unless otherwise specified)
Absolute Maximum Rating
FIAM 1 C 1 1
Product
Type 1 = 10A 2 = 20A
Baseplate 1 = Slotted 2 = Threaded 3 = Thru-hole
Pin Style 1 = Short 2 = Long
Product Grade C = –20 to +100 T = –40 to +100
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 FIAM, Filter Input Attenuator Module Rev. 1.1 Page 2 of 4
Set your site on VICOR at www.vicorpower.com
PRELIMINARY
2nd Generation
48Vdc Input
DC-DC Converters
FIAM
–IN
PR
PC
+IN
–OUT
–S
SC
+S
+OUT
–IN
EMI
GND
NC
+IN +OUT
NC NC
ON
OFF
–OUT
–IN
+IN
Note: The FIAM is shown in the on state. To disable,
open the connection between ON/OFF and –Out.
TRANSORB P/N
20461-120
Conducted Noise
Inrush Limiting Transient Immunity
Transient and Surge Protection
Figure 1—FIAM and Model V48A12C500A DC-DC converter. Figure 2—FIAM and Model V48B24C250A DC-DC converter.
Figure 3—Inrush Limiting: Inrush current with 330µF
external capacitance.
Tek Stop: Single Seq. 5.00MS/s
Ch1=Vdc in Ch2=Vdc out Ch3=Idc in
@0.2A/mV
2
[ T ]
Ch1 Zoom: 1.0X Vert 0.005X Horz
Ch1 10.0 V Ch2 10.0 V M2.00ms Ch1 31.8 V
Ch4 10.0mV
INPUT VOLTAGE
OUTPUT VOLTAGE
INPUT CURRENT
4
Figure 4—Transient Immunity: FIAM output response to an input transient.
Tek Run: 10.0MS/s
@ 200.0V
Ch1=Input
Ch2=Output
48V offset
2
Ch1 25.0V Ch2 25.0V M5.00µs Ch4 8.2A
INPUT TRANSIENT
OUTPUT VOLTAGE
Loading...