Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 FasTrak Maxi E-Grade Family Rev. 1.1 Page 2 of 8
Set your site on VICOR at www.vicorpower.com
Parameter 2V 3.3V 5V 12V 15V 24V 28V 48V 54V Unit Notes
Efficiency (typ.) 73.5 80.0 83.5 85.5 87.0 88.0 89.0 90.0 89.6 % Nominal input; 80% load; 25°C
Ripple and noise, p-p (typ.) 75 60 70 130 90 80 65 50 160 mV
Nominal input; full load;
25°C; 20 MHz BW
Output OVP setpoint (nom.) 2.8 4.3 6.3 14.3 17.8 28.1 32.7 55.7 62.6 Volts
25°C; recycle input voltage to
restart ( 1 minute off )
Dissipation, standby (typ.) 4.8 5.6 6.2 8.0 8.0 6.0 7.4 8.5 6.0 Watts No load; nominal input
Load regulation (max.) 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 ±% Vout No load to full load; nominal input
Current limit (typ.) 125 125 125 125 125 125 125 125 125 % Iout Output voltage 95% of nominal
Short circuit current (typ.) 125 125 125 125 125 125 125 125 125 % Iout Output voltage <250 mV
Parameter Min Typ Max Surge Withstand Unit Notes
Input voltage
24 Vin 18 24 36 50 Vdc <100 ms surge withstand
48 Vin 36 48 75 100 Vdc
300 Vin 180 300 375 400 Vdc
375 Vin 250 375 425 500 Vdc
Output voltage setpoint ±1 % Nominal input; full load; 25°C
Parameter Min Typ Max Unit Notes
Line regulation ±0.5 % Low line to high line; full load
Temperature regulation ±0.005 % / °C Over operating temperature range
Power sharing accuracy ±5 % 10 to 100% of full load
Programming range 10 110 %
Of nominal output voltage. For trimming below
90% of nominal, a minimum load of 10% of
maximum rated power may be required.
Parameter 24 Vin 48 Vin 300 Vin 375 Vin Units Notes
Undervoltage turn-on 17.5 34.9 175 243 Vdc Typical value
Undervoltage turn-off 15.3 30.5 153 212 Vdc Typical value
Overvoltage turn-off/on 37.8 78.8 N/A 446 Vdc Typical value
MODULE OPERATING SPECIFICATIONS
MODULE INPUT SPECIFICATIONS
MODULE OUTPUT SPECIFICATIONS
ELECTRICAL CHARACTERISTICS
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature,
unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate.
MODULE OUTPUT VOLTAGE RELATED SPECIFICATIONS
Note: For important information relative to applications where the converter modules are subject to continuous dynamic loading,
contact Vicor applications engineering at 800-927-9474.
Note: 300 Vin models do not have overvoltage turn-off.