VICOR FARM1CN2, FARM1CN1, FARM1C23, FARM1C21, FARM1C13 Datasheet

...
Set your site on VICOR at www.vicorpower.com
PRELIMINARY
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 FARM, Filter/Autoranging Rectifier Module Rev. 4.7 Page 1 of 12
Parameter Rating Unit Notes
L to N voltage 264 Vac Continuous L to N voltage 280 Vac 100ms +Out to –Out voltage 400 Vdc B OK to –Out voltage 16 Vdc EN to –Out voltage 16 Vdc Mounting torque 4-6(0.45-0.68) in-lbs (N-m) 6 each, 4-40 screw Pin soldering temperature 500 (260) °F (°C) <5 sec; wave solder Pin soldering temperature 750 (390) °F (°C) <7 sec; hand solder
Features
EMI filtering
Choice of 500W or 750W modules
96% Efficiency
Autoranging 115/230Vac input
Microprocessor controlled
Inrush current limiting
Mini sized package
Power fail signal
Module enable
Product Highlights
The FARM (Filter/Autoranging Rectifier Module) is an AC front-end module which provides EMI filtering, autoranging line rectification and inrush current limiting. The FARM is available in either 500/750W or 750/1000W models in a mini sized package measuring only 2.28" x 2.2" x 0.5".
The FARM interfaces directly with worldwide AC mains and may be used with Vicor 1st or 2nd Generation 300V input DC-DC converters to realize an autoranging, high density, low profile switching power supply. The FARM includes a microcontroller that continuously monitors the AC line to control bridge/doubler operation. The user need only provide external capacitance to satisfy system hold-up requirements.
Vicor 2nd Generation packaging technology offers flexible mounting options for various manufacturing processes. The FARM may be installed as a conventional leaded device for on-board applications, in-board for low profile, height restricted applications, socketed or surface mounted with optional ModuMate interconnect products.
Data Sheet
FARM
TM
Filter/ Autoranging Rectifier Module
Up to 1000 Watts
45
Shown actual size:
2.28 x 2.2 x 0.5 in
57,9 x 55,9 x 12,7 mm
Absolute Maximum Rating
Thermal Resistance and Capacity
Parameter Min Typ Max Unit
Baseplate to sink; flat, greased surface 0.16 °C/Watt Baseplate to sink; with thermal pad (P/N 20264) 0.14 °C/Watt Baseplate to ambient 8.0 °C/Watt Baseplate to ambient; 1000 LFM 1.9 °C/Watt
FARM 1 C 1 1
Product
Type 1 = 500/750W 2 = 750/1000W
Baseplate 1 = Slotted 2 = Threaded 3 = Thru-hole
Pin Style* 1= Short Pin 2= Long Pin S= Short ModuMate N= Long ModuMate
Product Grade C = –20°C to +100°C T = –40°C to +100°C
Part Numbering
*Pin styles S & N are compatible with the ModuMate interconnect system for socketing and surface mounting.
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 FARM, Filter/Autoranging Rectifier Module Rev. 4.7 Page 2 of 12
Set your site on VICOR at www.vicorpower.com
PRELIMINARY
Parameter Min Typ Max Unit Notes
Operating input voltage 90 132 Vac Autoranging (doubler mode) Operating input voltage 180 264 Vac Autoranging (bridge mode) Input undervoltage 90 Vac No damage AC line frequency 47 63 Hz C–Grade AC line frequency 47 880 Hz T–Grade Power factor 0.60 0.65 Typical line Inrush current
FARM1xxx 30 Amps 264Vac peak line, cold start FARM2xxx 60 Amps 264Vac peak line, cold start
Input surge withstand
2kV–50 µs common mode
EN61000-4-5
1kV–50 µs differential mode
SAFETY SPECIFICATIONS (FARM1xxx, FARM2xxx)
MODULE INPUT SPECIFICATIONS (FARM1xxx, FARM2xxx)
MODULE OUTPUT SPECIFICATIONS
Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output power and baseplate temperature, unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate. Specifications apply for AC mains having up to 5% total harmonic distortion.
Parameter Min Typ Max Unit Notes
Safety approvals UL 1950, CSA 22.2 No. 950,
TÜV, VDE, EN60950, CE Marked Isolation voltage (in to out) None Isolation provided by DC-DC converter(s) Isolation voltage (I/O to baseplate) 1500 Volts, rms Leakage current 1.2 mA 264Vac
FARM1xxx FARM2xxx
Parameter Min Typ Max Min Typ Max Unit Notes
Output power 0 500 0 750 Watts 90-132Vac Output power 0 750 0 1000 Watts 180-264Vac Efficiency, 120Vac 94 96 94 96 % Efficiency, 240Vac 94 96 94 96 % Output voltage 250 370 250 370 Vdc 90-264Vac Hold-up capacitance 1,800 3,300 µF
Set your site on VICOR at www.vicorpower.com
PRELIMINARY
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 FARM, Filter/Autoranging Rectifier Module Rev. 4.7 Page 3 of 12
Electrical Characteristics (continued)
MODULE CONTROL SPECIFICATIONS
MODULE GENERAL SPECIFICATIONS
Parameter Min Typ Max Unit Notes
AC Bus OK (B OK)
Low state resistance 15 To negative output - Bus normal Low state current 50 mA Bus normal High state voltage 14.8 15.0 15.2 Vdc Bus abnormal, 27K internal pull up to 15Vdc (see Fig.11) B OK true threshold 235 240 245 Vdc Output Bus voltage B OK false threshold 200 205 210 Vdc Output Bus voltage
Module Enable (EN)
Low state resistance 15 To negative output - Converters disabled Low state current 50 mA High state voltage 14.8 15.0 15.2 Vdc 150K internal pull up to 15Vdc (see Fig. 10) Enable threshold 235 240 Vdc Output bus voltage Disable threshold 185 190 195 Vdc Output bus voltage
AC Bus OK - Module Enable, differential error* 15 17 20 Vdc AC Bus OK and Module Enable thresholds track
Parameter Min Typ Max Unit Notes
MTBF >1,000,000 Hours 25˚C, Ground Benign Baseplate material Aluminum Cover Polyetherimide Pin Material Copper, Tin/lead solder dipped Weight 3.1(88) Ounces (grams) Size 2.28 x 2.2 x 0.5 Inches
57,9 x 55,9 x 12,7 (mm)
Storage Temperature (C, T-Grade) -40 +125 °C Operating Temperature (C-Grade) -20 +100 °C Baseplate
(T-Grade) -40 +100 °C Baseplate
* Tracking error between BUS OK and Enable thresholds
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 FARM, Filter/Autoranging Rectifier Module Rev. 4.7 Page 4 of 12
Set your site on VICOR at www.vicorpower.com
PRELIMINARY
Operating Characteristics
Figure 1—Start-up at 120Vac input
Figure 3—Power down, from 120Vac Figure 4—Power down, from 240Vac
Figure 2—Start-up at 240Vac input
Vdc output
Strap Engaged
Iac input @2A / mV
Iac input @2A / mV
Enable
Enable
B OK
Vdc output
B OK
Vdc output
Enable
B OK
Vdc output
Enable
B OK
Figure 5—Output overvoltage protection 240Vac range
Vdc output
Enable
B OK
Figure 6—Typical Conducted Emissions
Loading...
+ 8 hidden pages