Vicon VC-700W, VC-700WC Instruction Manual

VC-700W and VC-700WC
COLOR DOME CAMERAS
About this manual
INSTRUCTION MANUAL XX178-10
Before installing and using the camera, please read this manual carefully. Be sure to keep it handy for later reference. This installation should be made by a qualified service person and should conform to the National Electric Code, ANSI/NFPA 70 and all local codes. Installers should use appropriate hardware mounting materials.
This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instruction, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for a Class A computing device in accordance with the specification in subpart B of part 15 of the FCC rules, which are designed to provide reasonable protection against such interference in a commercial installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio and television reception, which can be determined by turning equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures:
FCC Notice
Note: Complies with Federal Communications Commission Rules & Regulations Part 15, Subpart B for a Class A digital device.
WARNING
• Reorient the receiving antenna.
• Relocate the equipment with respect to the receiver.
• Relocate the equipment away from the receiver.
• Plug the equipment into a different electrical outlet so that the equipment and receiver are on different branch circuits.
If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions.
Warning: Power must be removed from this unit before removing circuit modules or cables.
Caution: This unit contains circuit cards with integrated circuit devices that can be damaged by static discharge. Take all necessary precautions to prevent static discharge.
The user may find the following booklet prepared by the Federal Communications Commission helpful:
“Interference Handbook, Bulletin CIB-2”
This booklet is available from the U.S. Government Printing Office, Superintendent of Documents, Mailstop SSOP, Washington, D.C. 20402-9328, ISBN 0-16-045542-1.
Surface-Mount configuration In-Ceiling configuration
Dimensions : inch (mm)
PRECAUTIONS
Do not open or modify
Do not open the case except during maintenance and installation, as it may be dangerous and cause damages.
Do not put objects inside the unit
Make sure that no metal objects or flammable substances get inside the camera. This could cause fire, short-circuits or damages.
Be careful when handling the unit
To prevent damage, do not drop the camera or subject it to strong shock or vibration.
Install away from electric or magnetic fields
Protect from humidity and dust
Protect from high temperature
Be careful when installing close to the ceiling , in a kitchen or boiler room, as the temperature may rise to high levels.
Cleaning
Dirt can be removed from the case only by wiping it with a soft cloth moistened with a soft detergent solution.
Mounting Surface
The mounting surface material must be strong enough to support the camera.
TROUBLESHOOTING
Before sending the camera out for repair, check the items below. If the problem persists after checking these items, contact your service center.
If no image appears
Is the coaxial cable attached securely? Are the power and voltage normal? Has the iris of the lens inside the camera been adjusted correctly (with the level volume) ? Is there adequate illumination?
If the image is unclear
Is the lens in focus? Is the lens dirty? Dirt or fingerprints on the lens can adversely affect the images. Gently wipe any dirt or fingerprints off the lens with a soft cloth or lens cleaning paper and cleaning fluid (commercially available). Is the monitor adjusted correctly?
LENS ADJUSTMENT
1. Adjust the panning (360˚) and tilt (90˚) position.
2. Set the zoom position by using Zoom Lever Screw.
3. Set the focus by using Focus Lever Screw.
4. Loosen set screws (using small M1.0 Hex L-wrench provided) to adjust roll (turns camera position top/bottom).
PAN ROLL
SET
SCREW
(2X)
TILT
90˚
ZOOM
FOCUS
SPECIFICATION - VC-700W/C SERIES
General Spec NTSC PAL
HQ Interline Transf er CCD 1/3" 410K Pix els Color 1/3" 470k Pixels Color
Total Number of Pixels 811(H) X 508 (V) 795(H) X 596(V)
Scanning System 525 Lines 625 Lines
Hor iz on t a l Res olut ion
Sensitivity to Light [30IRE]
Gamma Correction
Shutter Speed 1/60 - 1/100,000[NTSC] 1/50 - 1/100,000[PAL]
S/N Ratio
Sync hronization
Video Output
Control DIP Sw itch
BLC
ME/A E
AWB
AGC
Electrical Spec
Operating Voltage
Pow er Consumption
Mechanical Spec
Opertion Temp
Air Humidity
Lens
Connections via
12VDC(11-20V), 24VAC(20-27V)
12VDC - 2.2W, 24VAC - 1.95W
0.45
550TV Lines
> 48dB [AGC off]
Internal / External (Line Lock)
0.04f c, 0.4Lux(Scene) With F1.2 Lens
Up to max.90%
3.3-12mm or 9-22mm
14°F ~ 131°F (-10°C ~ +55°C)
1.0Vp-p/75ohm Composite
BNC( VIDEO), 2P WIRE(POWER)
DIP Sw itc h Selec t ON/OFF
DIP Sw itc h Selec t ON/OFF
DIP Sw it c h S ele c t ME/ A E (ON/O FF)
DIP Sw itch Select ATW/AWB (ON/OFF)
SPECIFICATION - VC-700W-IR/C SERIES
General Spec NTSC PAL
HQ Interline Transf er CCD 1/3" 410K Pixels Color 1/3" 470k Pixels Color
Total Number of Pixels 811(H) X 508 (V) 795(H) X 596(V)
Scanning System 525 Lines 625 Lines
Hor iz on t a l Res olution
Sensitivity to Light [30IRE]
IR Dis tanc e
Gamma Correction
Shutter Speed 1/60 - 1/100,000[NTSC] 1/50 - 1/100,000[PAL]
S/N Ratio
Sync hronization
Video Output
Control DIP Sw itch
BLC
ME/A E
ATW/AWB
AGC
Electrical Spec
Operating Voltage
Pow er Consumption
Mechanical Spec
Opertion Temp
Air Humidity
Lens
Connections via BNC(VIDEO), 2P WIRE(POWER)
14°F ~ 131°F (-10°C ~ +55°C)
Up to max.90%
3.3-12mm
DIP Sw itc h Selec t ON/OFF
12VDC(11-20V), 24VAC(20-27V)
MAX LED ON (12VDC - 4.1W, 24VAC - 4.7W)
DIP Sw itc h Selec t ON/OFF
DIP Sw it c h S ele c t ME/ A E ( O N/ O FF)
DIP Sw itch Select ATW/AWB (ON/OFF)
0.45
> 48dB [AGC off]
Internal(12VDC) / External (Line Lock, 24VAC)
1.0Vp-p/75ohm Composite
550TV Lines
20m range
BW, NO LED : 0.004fc, 0.04Lux(Scene) With F1.2 Lens
COLOR : 0.04f c, 0.4Lux(Scene) With F1.2 Lens
SPECIFICATION - VC-700WDN/C SERIES
General Spec N TSC PAL
HQ Interline Transfer CCD 1/3" 410K Pixels Color 1/3" 470k Pixels Color
Total Number of Pixels 811(H) X 508 (V) 795(H) X 596(V)
Scanning System 525 Lines 625 Lines
Horizontal Resolution
Sensitivity to Light [30IRE]
Gamma Correction
Shutter Speed 1/60 - 1/100,000[NTSC] 1/50 - 1/100,000[PAL]
S/N Ratio
Synchronization
Video Output
Control DIP Switch
BLC
ME/ A E
ATW/AWB
AGC
Electrical Spec
Operating Voltage
Pow er Consumption
Mechanical Spec
Opertion Temp
Air Humidity
Lens
Connections via
Up to max.90%
3.3-12mm or 9-22mm
BNC( V IDEO), 2P WIRE( POWER)
BW : 0.004f c, 0.04Lux(Scene) With F1.2 Lens
12VDC(11-20V), 24VA C(20-27V)
12VDC - 2.3W, 24VAC - 2.6W
14°F ~ 131°F (-10°C ~ +55°C)
DIP Sw itch Selec t ME/AE (ON/OFF)
DIP Sw itch Selec t ATW/A WB (ON/OFF)
Internal(12VDC) / External (Line Lock, 24VAC)
1.0Vp-p/75ohm Composite
DIP Sw itch Selec t ON/OFF
550TV Lines
Color : 0.04fc, 0.4Lux(Scene) With F1.2 Lens
0.45
> 48dB [AGC off]
DIP Sw itch Selec t ON/OFF
CONNECTIONS
CAUTION
The use of a UL Listed Class 2 power supply is required to ensure compliance with electrical safety standards. Check for polarity when using a 12 VDC power supply.
Cable for connection to portable monitor, provided. When using a portable monitor, terminate at 75 ohms (at last device).
12VDC-24VAC
12VDC-24VAC
RED (+)
-
11.8in
(
300m
RED (+)
-
Surface-Mount Base
In-Ceiling Base
CAMERA SETTINGS FOR VC-700W SERIES
CAMERA SETTINGS
(1) BLC
(2) ME/AE
(3) AWB
(4) AGC
(5) DC Iris volume
(6) 2nd Video out
(7) Line Lock
(1) Compensating for backlight
ON When back light is too bright
OFF Normal setting
CAUTION : This can also be set correctly by adjusting DC Lens control (5).
(2) Confirming the iris setting
ME The default setting when DC autoiris lens is installed
AE The default setting when fixed iris lens is installed
CAUTION : The iris setting is preadjusted to the best condition for
use at time of factory shipment; it shouldn't be necessary to change settings.
(3) Confirming the White Balance
(4) Setting gain control (AGC)
For adjusting the sensitivity of the camera. Use this setting in dark environments.
ON Normal setting
OFF Set this when there is excessive video noise
AWC
Use this under light source below 2500K and over 9500K of Natrium (Sodium) low color temperature light.
ATW
Use this under light source between 2500K and 9500K of fluorescent lamp or incandescent light
(5) Adjusting level control
If the entire image is too dark or bright, or the backlight
compensation is not correct even after (1) is set to "ON,"
adjust the iris level.
CCW (Low) Closes the lens iris, making the entire image darker
CW(High) Opens the lens iris, making the entire image brighter
(6) Second VIDEO OUT connector
If installer is setting with portable monitor, use this connector.
(7) Setting monitor synchronization (24 VAC adaptor users)
The camera offers V-phase adjustment over 360°. Vertical sync disturbance may occur
when a switcher is used to switch between multiple cameras connected to one monitor.
To prevent vertical sync disturbance, adjust (7) by pushing the button. Before making any
adjustment, confirm that the cameras are connected to the power supply with the same
polarity. To make an adjustment:
While observing the video outputs from the cameras on an oscilloscope, press
the the first camera's V-phase pushbutton. Until vertical sync from all cameras are
in phase. If the first camera's adjustment phase is insufficient, adjust the second
camera's V-phase contol in the oppposite direction until they are in phase.
CAUTION
When using the 12 VDC adaptor, sync setting is set to internal sync.
NOTE: Sync is selected by a switch on the camera board, Int or L/L (Line Lock).
INSTALLATION
A
B
D
C
E F
2.46(R62.5)
2.30(R58.5)
4-0.17(Θ4.3)
2.46(R62.5)
2.30(R58.5)
360˙
The VC-700W can be either mounted to a surface (like a ceiling or wall) or installed into the ceiling, with or without an electrical box.
1 Use the large (Torx T20) L-Wrench to loosen the 4 screws (B) securing the dome assembly. 2 For surface-mount installations, align the mounting base (D) with the mounting surface; mark the mounting screw holes and then drill the four holes. For in-ceiling installations not mounting to a 4x4 electrical box, mark the holes in the camera assembly (C) and then drill the holes. For in-ceiling installations, (D) is not used. 3 For in-ceiling installations, cut a hole (diameter: 2.9 in./73 mm) in the ceiling for routing the cables. 4 Route the power cable(s) and video cable(s) to the installation location. 5 Align the four mounting holes in (D) with the holes in the ceiling. Using the four screws and anchors provided (G), if appropriate for mounting surface, fasten the mounting base to the wall/ceiling. Using the other four screws provided, secure the camera assembly (C) to the mounting base. For in-ceiling installations, align the holes in (C) with the holes drilled in the ceiling and secure the camera assembly with the hardware provided, if appropriate. If installing to an electrical box, secure (C) with the screws provided. 6 Pass the power cable (E) and video cable (F) from the camera unit through the cable hole in the ceiling. For surface-mounted units, cabling is routed through the knockout hole in the side of the unit. 7 Carry out the settings and adjustments for the camera previously described. 8 Secure the dome assembly (A) by tightening the screws (B).
Vicon Industries Inc.
Corporate Headquarters
89 Arkay Drive
Hauppauge, New York 11788
USA
631-952-CCTV (2288) 800-645-9116
Fax: 631-951-CCTV (2288)
European
Headquarters
Brunel Way
Fareham, PO15 5TX
United Kingdom
+44(0) 1489 566300
Fax: +44(0) 1489 566322
Germany
vin-videotronic infosystems gmbh
Lahnstrasse
D-24539 Neumuenster
Phone: +49 (0) 4321 8790
Fax: +49 (0) 4321 879 47
Internet Address: www.vicon-cctv.com
Vicon Part Number 8009-8178-10-01 Rev 609
Far East Office
Unit 5, 17/F, Metropole Square
2 On Yiu Street, Shatin
New Territories,
Hong Kong
(852) 2145-7118
Fax: (852) 2145-7117
©Copyright 2009, Vicon Industries Inc. Product specifications subject to change without notice.