Vicon VC-600W, VC-610W, VC-600WS, VC-610WS, VC-600WDN Instruction Manual

...
VC-600W, VC-600WS VC-610W, VC-610WS SERIES
COLOR DOME CAMERAS
About this manual
INSTRUCTION MANUAL XX173-02
Before installing and using the camera, please read this manual carefully. Be sure to keep it handy for later reference. This installation should be made by a qualified service person and should conform to the National Electric Code, ANSI/NFPA 70 and all local codes.
CAMERA DIMENSIONS in. (mm)
Before sending the camera out for repair, check the items below. If the problem persists after checking these items, contact your service center.
If no image appears
Is the coaxial cable attached securely? Are the power and voltage normal? Has the iris of the lens inside the camera been adjusted correctly (with the level volume) ? Is there adequate illumination?
If the image is unclear
Is the lens in focus? Is the lens dirty? Dirt or fingerprints on the lens can adversely affect the images. Gently wipe any dirt or fingerprints off the lens with a soft cloth or lens cleaning paper and cleaning fluid (commercially available). Is the monitor adjusted correctly?
PRECAUTIONS
Do not open or modify Do not open the case except during maintenance and installation, as it may be dangerous and cause damage.
Do not put objects inside the unit Make sure that no metal objects or flammable substances get inside the camera. It could cause fire, short-circuits or damages.
Be careful when handling the unit To prevent damage, do not drop the camera or subject it to strong shock or vibration.
Install away from electric or magnetic fields
Protect from humidity and dust
Protect from high temperature
Be careful when installing close to the ceiling, in a kitchen or boiler room, as the temperature may rise to high levels.
Cleaning Dirt can be removed from the case only by wiping it with a soft cloth moistened with a soft detergent solution.
Mounting Surface The mounting surface material must be strong enough to support the camera.
TROUBLESHOOTING
SPECIFICATION VC-600W/VC-600WS
SPECIFICATION VC-610W/VC-610WS
GENERAL Spec NTSC PAL
HQ Interline Transfer CCD 1/3" 410K Pixels Color 1/3" 470K Pixels Color Total Number of Pixels 811(H) x 508(V) 795(H) x 596(V) Scanning System 525 Lines 625 Lines Horizontal Resolution Sensitivity to Light [30IRE] Gamma Correction Shutter Speed 1/60 - 1/100,000[NTSC] 1/50 - 1/100,000[PAL] S/N Ratio Synchronization Video Output
Control DIP Switch
BLC ME/AE ATW/AWB AGC
Electrical Spec
Operating Voltage Power Consumption
Mechanical Spec
Operatio n Temp Air Humidity Lens Mount Connections via
550TV Lines
0.03fc, 0.3Lux(Scene) With F1.2 Lens
0.45
> 48dB [AGC off]
Internal (12VDC) / External (Line Lock, 24VAC)
1.0Vp-p/75ohm Composite
DIP Switch Select ON/OFF DIP Switch Select ME/AE (ON/OFF) DIP Switch Select ATW/AWB (ON/OFF) DIP Switch Select ON/OFF
12VDC(11-20V), 24VAC(20-27V) 12VDC -2.3W, 24VAC - 2.6W
14°F ~ 131°F ( -10°C ~ +55°C ) Up to max.90%
3.3-12mm BNC(VIDEO), 2P WIRE(Power)
GENERAL Spec NTSC PAL
CCD Type 1/3" 410K Pixels Color 1/3" 470K Pixels Color Total Number of Pixels 811(H) x 508(V) 795(H) x 596(V) Scanning System 525 Lines 625 Lines Horizontal Resolution Sensitivity t o Light [30IRE] Gamma Correction Shutter Speed 1/60 - 1/100,000[NTSC] 1/50 - 1/100,000[PAL] S/N Ratio Synchronization Video Output
Control DIP Switch
ME/AE ATW/AWB WDR ON/OFF AGC MAX ON
Electrical Spec
Operating Voltage Power Consumption
Mechanical Spec
Operation Temp Air Humidity Lens Mount Connections via
BNC(VIDEO), 2P WIRE(Power)
0.45
0.06fC, 0.6Lux(Scene) With F1.2 Lens
480TV Lines
1.0Vp-p/75ohm Composite
Internal (12VDC) / External (Line Lock, 24VAC)
> 45dB [AGC off]
12VDC -3.9W, 24VAC - 4.0W
12VDC(11-20V), 24VAC(20-27V)
3.3-12mm
DIP Switch Select ATW/AWB (ON/OFF)
DIP Switch Select ME/AE (ON/OFF)
Up to max.90%
14°F ~ 131°F ( -10°C ~ +55°C )
DIP Switch Select ON/OFF
DIP Switch Select WDR (ON/OFF)
SPECIFICATION VC-600WDN/VC-600WDN-S
SPECIFICATION VC-600WIR/VC-600WIR-S
GENERAL Spec NTSC PAL
HQ Interline Transfer CCD 1/3" 410K Pixels Color 1/3" 470K Pixels Color Total Number of Pixels 811(H) x 508(V) 795(H) x 596(V) Scanning S y stem 525 Lines 625 Lines Horizontal Resolution Sensitivity to Light [30IRE] Gamma Correction Shutter Spee d 1/60 - 1/100,00 0[N T SC ] 1/50 - 1/ 1 00, 00 0[ P A L] S/N Rati o Synchronization Video Output
Control DIP Switch
BLC ME/AE ATW/AWB AGC
Electrical Spec
Operating Voltage Power Consumption
Mechanic al Sp ec
Operation Temp Air Humidity Lens Mount Connections via
14°F ~ 131°F ( -10°C ~ +55°C ) Up to max.90%
3.3-12mm BNC(VIDEO), 2P WIRE(Power)
DIP Switch Select ATW/AWB (ON/OFF) DIP Switch Select ON/OFF
12VDC(11-20V ), 24VAC(20-27V) 12VDC -2.3W, 24VA C - 2.6W
Internal (12V DC ) / E xter nal (Lin e Lock, 24VAC)
10Vp-p/75ohm Composite
DIP Switch Select ON/OFF DIP Switch Select ME/AE (ON/OFF)
550TV Lines
0.04fc, 0.4Lux(Scene) With F1.2 Lens
0.45
> 48dB [AG C off]
GENERAL Spec NTSC PAL
HQ Interline Tran s fer CCD 1/3" 410K Pixels C ol or 1/3" 470K Pixels Color Total Number of Pixels 811(H) x 508(V) 795(H) x 596(V) Scanning System 525 Lines 625 Lines Horizontal Resolution Sensitivity to Light [30IRE] Gamma Correction Shutter Speed 1/60 - 1/100,000[NTSC] 1/50 - 1/100,000 [PAL] S/N Ratio Synchronization Video Output
Control DIP Switch
BLC ME/AE ATW/AWB AGC
Electrical Spec
Operating Vol tage Power Consumption
Mechanical Spec
Operation Tem p Air Humidity Lens Mount Connections via
550TV Lines
(BW, N o L ED ) 0. 04fc, 0.4Lux(Scene) Wit h F 1. 2 Lens
0.45
> 48dB [AGC off]
Internal (12VDC) / External (Line Lock, 24VAC)
10Vp-p/75ohm Composit e
DIP Switch Select ON/OF F DIP Switch Select ME/AE (ON/OFF) DIP Switch Select AT W/AWB (ON/OFF) DIP Switch Select ON/OF F
12VDC(11-20V), 24VAC(20-27V) MAX LED ON (12VDC - 4.6W, 24VAC - 4.7W)
14°F ~ 131°F ( -10°C ~ +55°C ) Up to max.90%
3.3-12mm BNC(VIDEO), 2P WIRE(Power)
LENS ADJUSTMEN
T
VC-600W/VC-600WS, VC-610W/VC-610WS, VC-600WDN/VC-600WDN-S
VC-600WIR/VC-600WIR-S
CONNECTION
LENS ADJUSTMENT AND CONNECTION
1. Adjust the panning (360˚) and tilt (51˚) position.
2. Set the zoom position by using Zoom Lever Screw.
3. Set the focus by using Focus Lever Screw.
4. Loosen set screws to adjust roll (turns camera position top/bottom).
CAUTION
Check for polarity when using a 12VDC power supply.
Input Voltage : 12VDC/24VAC CLASS 2 NOT WET, CLASS 3 WET
1. Adjust the panning (360˚) and tilt (60˚) position.
2. Set the zoom position by using Zoom Lever Screw.
3. Set the focus by using Focus Lever Screw.
4. Loosen set screws to adjust roll (turns camera position top/bottom).
PAN - 360˚
TILT - 60˚
Zoom
Focus
Set Screw (2x)
°
TILT - 51˚
PAN - 360˚
12VDC
Red (+)
Black (-)
24VAC
VC-600W, VC-600WS
DIP Switch Functions (1) Compensating for backlight ON When backlight is too bright OFF Normal setting
CAUTION : It will be correctly set by adjusting level volume 5.
(2) Confirming the iris setting ME(ON) When DC autoiris lens installed AE(OFF) When fixed iris lens is installed
(3) White balance setting ATW(ON) Use this under light source below 2500K and
over 9500K of Natrium (Sodium) low color temperature light
AWB(OFF) Use this under light source between 2500K
and 9500K of fluorescent lamp or incandescent light
(4) Setting gain control (AGC)
For adjusting the sensitivity of the camera. Use this setting for shooting in dark environments.
ON Normal setting OFF Set this when there is excessive noise
Second Video OUT Connector (Option)
If installer is setting with portable monitor, this connector is used. Be sure to terminate the last video device at 75 ohms.
IR LED Connector (Option)
If extra IR LED board is attached, this connector is used.
CAMERA SETTINGS
PORTABLE
MONITOR
IR LED
LINE LOCK
ADJUSTMENT
DC LENS CONTROL
DC
VARIFOCAL
POWER
CONNECTOR
Setting Monitor Synchronization (24 VAC adaptor users)
The camera offers V-phase adjustment over 360°. Vertical sync disturbance may occur when a switcher is used to switch between multiple cameras connected to one monitor. To prevent vertical sync disturbance, adjust ④*. CAUTION: When using the 12 VDC adaptor, sync setting is set to internal sync.
Adjusting Level Volume
If the entire image is too dark or bright, or the bakclight compensation is not correct even after is set to "ON", you need to adjust the level volume.
CCW (LOW) Closes the lens iris, making the entire image darker CW (HIGH) Opens the lens iris, making the entire image brighter
DC Varifocal Connector
This should be used with DC IRIS LENS.
Power connector
Connect with AC/DC power, board attached inside.
*Before making any adjustment, confirm that the cameras are connected to the power supply with the same polarity. To make an adjustment: While observing the video outputs from the cameras on an oscilloscope, press the first camera's V-phase pushbutton. Until vertical sync from all cameras are in phase. If the first camera's adjustment phase is insufficient, adjust the second camera's V-phase contol in the oppposite direction until they are in phase.
VC-610W, VC-610WS : WDR SETTING
DC LENS
CONTROL
LINE LOCK
ADJUSTMENT
PORTABLE
MONITOR
DC
VARIFOCAL
IR LED
OFF ON 1 AE/ME AE ME 2ATW/AWBAWBATW 3 WDR OFF ON 4 AGC MAX OFF ON
NO FUNCTION
DIP S/W
POWER
CONNECTOR
DIP Switch Functions (1) Confirming the iris setting ME(ON) When DC autoiris lens installed AE(OFF) When fixed iris lens is installed
(2) White balance setting ATW(ON) Use this under light source below 2500K and
over 9500K of Natrium (Sodium) low color temperature light
AWB(OFF) Use this under light source between 2500K
and 9500K of fluorescent lamp or incandescent light
(3) WDR mode ON Wide dynamic function is working OFF Wide dynamic function is not working
(4) Setting gain control (AGC)
For adjusting the sensitivity of the camera. Use this setting for shooting in dark environments.
ON Normal setting OFF Set this when there is excessive noise
Second Video OUT Connector (Option)
If installer is setting with portable monitor, this connector is used. Be sure to terminate the last video device at 75 ohms.
IR LED Connector (Option)
If extra IR LED board is attached, this connector is used.
Setting Monitor Synchronization (24 VAC adaptor users)
The camera offers V-phase adjustment over 360°. Vertical sync disturbance may occur when a switcher is used to switch between multiple cameras connected to one monitor. To prevent vertical sync disturbance, adjust ④*. CAUTION: When using the 12 VDC adaptor, sync setting is set to internal sync.
Adjusting Level Volume
If the entire image is too dark or bright, or the bakclight compensation is not correct even after is set to "ON", you need to adjust the level volume.
CCW (LOW) Closes the lens iris, making the entire image darker CW (HIGH) Opens the lens iris, making the entire image brighter
DC Varifocal Connector
This should be used with DC IRIS LENS.
Power connector
Connect with AC/DC power, board attached inside.
*Before making any adjustment, confirm that the cameras are connected to the power supply with the same polarity. To make an adjustment: While observing the video outputs from the cameras on an oscilloscope, press the first camera's V-phase pushbutton. Until vertical sync from all cameras are in phase. If the first camera's adjustment phase is insufficient, adjust the second camera's V-phase contol in the oppposite direction until they are in phase.
VC-600WDN, VC-600WDNS, VC-600WIR, VC-600WIRS : TDN/IR SETTING
DIP Switch Functions (1) Compensating for backlight ON
When backlight is too bright
OFF
Normal setting
CAUTION : It will be correctly set by adjusting level volume 5.
(2) Confirming the iris setting ME(ON)
When DC autoiris lens installed
AE(OFF)
When fixed iris lens is installed
(3) White balance setting ATW(ON)
Use this under light source below 2500K and over 9500K of Natrium (Sodium) low color temperature light
AWB(OFF)
Use this under light source between 2500K and 9500K of fluorescent lamp or incandescent light
(4) Setting gain control (AGC)
For adjusting the sensitivity of the camera. Use this setting for shooting in dark environments.
ON
Normal setting
OFF
Set this when there is excessive noise
PORTABLE MONITOR
DC VARIFOCAL
LINE LOCK
ADJUSTMENT
Second Video OUT Connector (Option)
If installer is setting with portable monitor, this connector is used. Be sure to terminate the last video device at 75 ohms.
IR LED Connector (Option)
If extra IR LED board is attached, this connector is used.
Setting Monitor Synchronization (24 VAC adaptor users)
The camera offers V-phase adjustment over 360°. Vertical sync disturbance may occur when a switcher is used to switch between multiple cameras connected to one monitor. To prevent vertical sync disturbance, adjust ④*. CAUTION: When using the 12 VDC adaptor, sync setting is set to internal sync.
Adjusting Level Volume
If the entire image is too dark or bright, or the bakclight compensation is not correct even after is set to "ON", you need to adjust the level volume.
CCW (LOW)
Closes the lens iris, making the entire image darker
CW (HIGH)
Opens the lens iris, making the entire image brighter
DC Varifocal Connector This should be used with DC IRIS LENS.
Power connector
Connect with AC/DC power, board attached inside.
*Before making any adjustment, confirm that the cameras are connected to the power supply with the same polarity. To make an adjustment: While observing the video outputs from the cameras on an oscilloscope, press the first camera's V-phase pushbutton. Until vertical sync from all cameras are in phase. If the first camera's adjustment phase is insufficient, adjust the second camera's V-phase contol in the oppposite direction until they are in phase.
in phase. If the first camera's adjustment phase is insufficient, adjust the second camera's V-phase contol in the oppposite direction until they are in phase.
INSTALLATION
VC-600WIR/VC-600WIRS
B
C
D
E
F
G
A
A
B
C
D
E
F
G
H
I
VC-600W/VC600WS, VC-610W/VC-610WS, VC-600WDN/VC-600WDNS
1 Use the supplied hexagon wrench to remove the four fixing screws (B) securing the dome cover (A). 2 Make screw holes and a cable hole in the supplied gasket (D) that attaches to the back of the camera unit (C) .
3 Attach the gasket (D) to the back of the camera unit (C). 4 Align the camera unit with the mounting surface; mark where the screw
holes are to be drilled and then drill the four holes.
5 Cut a hole (diameter: 2.9 in. / 73mm) in the ceiling for routing the cables. 6 Pass the power cable (E) and video cable (F) from the camera unit
through the cable hole in the ceiling. If mounting to a surface other than the ceiling, the cable can be routed through the hole in the side of the unit. 7 Align the four screw holes in the camera unit (C) with the screw holes in the installation surface, and then secure the camera in place by tightening the four or more screws (G).
8 Carry out the settings and adjustments for the camera. 9 If the dome liner (H) is secured in place, loosen the screw (I).
Adjust the dome liner (H) so that the dome camera's lens is visible from the camera window. 10 Use a philips screwdriver to secure the dome cover (A) by tightening the screws (B). 11 When mounting outdoors on a wall, caulk the entire perimeter of the camera unit base with a uniform bead of silicon RTV adhesive or equivalent sealing compound.
Note: The VC-600W/VC-610W series can be mounted in a pendant (suspended) configuration from a wall mount, a ceiling mount or from a 1/2- inch NPT pipe with the use of the VC-600W-PLATE adapter plate and the V910-PH.
Germany
vin-videotronic infosystems gmbh
Lahnstrasse
D-24539 Neumuenster
Phone: +49 (0) 4321 8790
Fax: +49 (0) 4321 879 47
Internet Address: www.vicon-cctv.com
Vicon Industries Inc.
Corporate Headquarters
89 Arkay Drive
Hauppauge, New York 11788
USA
631-952-CCTV (2288) 800-645-9116
Fax: 631-951-CCTV (2288)
European Headquarters
Brunel Way
Fareham, PO15 5TX
United Kingdom
+ 44(0) 1489 566300
Fax: + 44(0) 1489 566322
Vicon Part Number 8009-8173-02-01, rev 408
Far East Office
Unit 5, 17/F, Metropole Square
2 On Yiu Street, Shatin
New Territories,
Hong Kong
(852) 2145-7118
Fax: (852) 2145-7117
Loading...