Vicon Industries Inc. does not warrant that the functions contained in this equipment will meet your requirements or that the
operation will be entirely error free or perform precisely as described in the documentation. This system has not been designed
to be used in life-critical situations and must not be used for this purpose.
Document Number: 8009-8252-20-02
Product specications subject to change without notice.
This guide provides a quick installation guide and a step-by-step procedure
to set up V9360 IP Hemispheric Cameras for use wit h t he Vic onNet® Video
Management System. It as sumes an understanding of V iconNet and the
camera. Refer to the Vico nNet and camera manuals for deta il ed i nformation.
The camera has an IP Util ity (Dis cov er y ) tool that pr ovides a way for it to be
found on the network. After it has been added to the network, the camera is
then connected to the ViconN et system.
Go to Vicon’s website,
manuals and the IP Utility tool.
www.vicon-security, to find full installation and user
2 | Setup V9360 Hemispheric Cameras
Micro SDHC Card Slot
Digital Input/Output
Power LED
12 VDC Power Input
Audio Input/Output
Installation and Connecti ons
The camera package includes all the hardware necessary for installation,
including terminal blocks. A template is also include d for in s t al lat i on.
Additionally, a PC and monit or, a Network Switch and an RJ-45 network
cable (1 for each device) are required.
PoE switches that are IEEE802.3af compliant can pow er the camera directly.
For devices connected to a non-PoE switch, a power adapter is required with
the terminal block. Connect the white striped wire to t he 12 V pin and the
black wire to the GND (ground) pin.
Connections
Indoor Version
Reset Button
Ethernet Port
Outdoor Version
Digital Input/Output
Reset Button
Micro SDHC Card Slot
Power Button
Setup V9360 Hemispheric Cameras | 3
12 VDC Power Input
Ethernet Port
Audio Input/Output
4 | Setup V9360 Hemispheric Cameras
Pin 1
GND
Ground. Connect with Pin 3 for DI
control loop.
Pin 2
12 VDC
Provides power to externa l
Voltage: 12 VDC,
Pin 3
Digital
Connect to GND (Pin 1) to
Must not be exposed
Pin 4
Digital
Connect to Pin 2 through ext er nal
voltages.
Max load = <100 mA
Pin 5
GND
Ground. Connect with Pin 7 for DI
Pin 6
12 VDC
Provides power to externa l
of 100 mA.
Voltage: 12 VDC,
Pin 7
Digital
Connect to GND (Pin 5) to
(unconnected) to deactivate.
Must not be exposed
than 30 VDC.
Pin 8
Digital
Connect to Pin 6 through ext er nal
voltages.
Max load = <100 mA
Digital Input/Output
Digital Output: 2 digital outputs for connecting external devices, such as
relays. Connect Pin 2 with Pin 4 or P in 6 w ith Pin 8.
Digital Input: Alarm input, NO/NC.
Input 1
Output 1
Input 2
Output 2
devices with a maximu m c ur r ent
of 100 mA.
activate or leave floating
(unconnected) to deactivate.
devices for DO loop. If used with
an external relay, a diode must be
connected in parallel with the load
for protection against transient
control loop.
devices with a maximu m c ur r ent
activate or leave floating
devices for DO loop. If used with
an external relay, a diode must be
connected in parallel with the load
for protection against transient
Max: 1.2 W
to voltages greater
than 30 VDC.
Max voltage = 24 VDC
(to the transistor)
Max: 1.2 W
to voltages greater
Max voltage = 24 VDC
(to the transistor)
Connect input/output devices to the camera as follo ws:
1. Attach the cables for the device securely to the supp lied gr een connector
block.
2. Once cables are connec t ed, push c onnector block into the terminal
connector on camera.
Digital Input/Output Connector
Setup V9360 Hemispheric Cameras | 5
12 VDC Power Input
Connect DC power source t o t he t er minal block. The wire with white da shed
lines is the live wire, which s hould connect to the 12V pin.
PIN NAME DESCRIPTION
1 E-Ground Chassis Ground
2 GND
DC Power Input
3 12 V
Refer to the complete Hardware Manual for detailed instr uc t i on on installation
and connections.
6 | Setup V9360 Hemispheric Cameras
IP Address
Camera Discovery
The camera is accessed thr ough a standard web browser; Windows®
Internet Explorer® 8.0 and above. The IP address for your PC must be within
the same subnet as the IP dev ice. Y ou need to match the TCP/IP setti ngs
between PC and IP device befor e you can access it via Internet Explorer. If
the IP address of the camera is not known, use the camera’s IP Utility
(Discovery) tool. By default the camera is set t o obtain the IP address
automatically via DHCP; if your network does not have DHCP, the default IP
address is 192.168.0.100.
Note
If your network has a DHCP server and the UPnP function is enabled on your
PC on the same network, y ou can fi nd t he camera in “My Network;”double
click on the device to open its web page (the default browser mu s t be
Internet Explorer). Proceed directly to the Adding C ameras to the Nucleus
section.
1. Execute the IP Util ity (found on our websit e,
www.vicon-security.com/
on this camera’s page; it will sear ch cameras on the netw ork
automatically.
2. Select the camera (underlined IP link) on the list to acc ess t he
camera. The PC should be on the same subnet so it can be use d t o
open the camera page or use it t o assign an IP address.
3. The Configuration Tool B ar (A) offers a choice of functions t hat can
be controlled for the selec t ed camera. The Global sett ing Par ameter
(B) allows the configuration of mu lt ip le cameras at one time. The
Device List (C) provides in formation on all connected devices. The
Manual Input Bar (D) allow s ent er in g an IP address that is not
showing up in the Device List.
Setup V9360 Hemispheric Cameras | 7
4. Connect to the desired ca mer a by clicking on the IP address.
5. After connecting to the ca mera, the Login page will display .
6. The default User Name is Admin; the default Password in 123456.
7. Note
If your browser has pop-u p blocking enabled, you will hav e t o allow
the camera’s IP. You may also be prompted to install the cam er a’s
Active X in the browser to allow the video.
8. After logging in, the Live View w ill di splay. To go to the main menu,
click Setup in the top left corner of the screen.
8 | Setup V9360 Hemispheric Cameras
If you have access to a web brows er and know the camera IP address, you
can go directly to the Networ k scr een from the camera browser int er fa c e t o
configure the network.
Select Static IP Address. Ent er t he desired IP address (avoid the default IP
192.168.0.100). Clic k Apply and then click System >Save & Reboot.
Adding Cameras to the Nu cleus
The camera must be adde d t o the Nucleus of the system to be re cognized on
the ViconNet site list.
V9360 cameras do not require a license, but do not automatically show up on
the site list and must be added to the ViconNet system. Refer to the camera
manual for details on installation and setup of the camera.
Note:
V9360 cameras do not need to be register ed and only need to be added
once in the Nucleus for the ent ire system.
1. From the ViconNet Main window, click . The Setup Site
Selection window is displayed.
2. Select the Nucleus for which you want to configure the camera and
click . The System Settings window is displayed.
3. From the System Settings w indow , select the
button.
Setup V9360 Hemispheric Cameras | 9
4. Click on the Open Standard Camera
settings screen.
5. The detected cameras are displayed and are added aut omatically to
the list. A message will display to add a User Name and Password for
each detected camera. Th e User Name and Password for t he camera
are the camera’s identity in its browser. It is recommended that the
user be administrator lev el t o be able to access all camera featur es.
After being named, the camera can be activated. Click on the
camera. Click the button. The Camera
Details area will become e nabled.
Note:
Cameras will only be detect ed if they are on the same LAN as the PC.
Cameras that are not on the LAN have to be added manually. Refer to the
instruction manual for the c amera to add cameras manua lly .
1. Enter a Camera Name for t his camera and select IP or DNS.
2. The format is set from the camera’s Video Settings screen. Select the
same format, H.264, MPEG-4 or M-JPEG.
3. The Port Number will default t o 80; this can be changed as required.
4. Enter a User Name and Passwor d for this camera. It is recom me nded
that the user be administr at or level to be able to access all camera
features. Default User an d Password are “Admin” and “ 123456”.
5. Click Save to save the settings. An Undo button is p r ovided.
6. Click on the camera to be set up fro m the camera list. Click the
button.
7. Click the button for a
direct link to the browser for t hat cam er a, if n eeded. Click Save and
Close.
8. To make sure you can use Quick Playback, select the Quick
Playback Storage Sourc e. Fr om the dropdown list, select from the
NVR on which this camera will be recorded.
10 | Setup V9360 Hemispheric Cameras
9. Click on the button.
This opens a screen that allows setting up authorization for Liv e
View, Playback and PTZ actions by selecting () or deselecting
( ) the appropriate categories, as required. If all cameras are to
have the same authorizati ons , check Apply to all camer as box t o
avoid setting up each camera individually.
When this procedure is comp lete, t he c amera will appear on the Vic onNet
site list and there will be access to the video.
Vicon Industries Inc.
For office locations, visit the website:
www.vicon-security.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.