Vicon V700-C Series Instruction Manual

V700-C Series
COLOR DOME CAMERAS
About this manual
INSTRUCTION MANUAL XX178-01
Before installing and using the camera, please read this manual carefully. Be sure to keep it handy for later reference. This installation should be made by a qualified service person and should
conform to the National Electric Code, ANSI/NFPA 70 and all local codes. Installers should use appropriate hardware mounting materials.
This equipment generates and uses radio frequency energy and if
not installed and used properly, that is, in strict accordance with the
manufacturer’s instruction, may cause interference to radio and
television reception. It has been type tested and found to comply with the limits for a Class A computing device in accordance with
the specification in subpart B of part 15 of the FCC rules, which are
designed to provide reasonable protection against such interference in a commercial installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio and television reception, which can be determined by turning equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures:
• Reorient the receiving antenna.
• Relocate the equipment with respect to the receiver.
FCC Notice
Note: Complies with Federal Communications Commission Rules &
Regulations Part 15, Subpart B for a Class A digital device.
WARNING
Warning: Power must be removed from this unit before
removing circuit modules or cables.
Caution: This unit contains circuit cards with integrated circuit
devices that can be damaged by static discharge. Take all necessary precautions to prevent static discharge.
• Relocate the equipment away from the receiver.
• Plug the equipment into a different electrical outlet so that the
equipment and receiver are on different branch circuits. If necessary, the user should consult the dealer or an experienced
radio/television technician for additional suggestions. The user may find the following booklet prepared by the Federal
Communications Commission helpful:
“Interference Handbook, Bulletin CIB-2
This booklet is available from the U.S. Government Printing Office, Superintendent of Documents, Mailstop SSOP, Washington, D.C. 20402-9328, ISBN 0-16-045542-1.
Surface-Mount configuration In-Ceiling configuration
Dimensions : inch (mm)
PRECAUTIONS
Do not open or modify Do not open the case except during maintenance and installation, as it may be dangerous and cause damages.
Do not put objects inside the unit Make sure that no metal objects or flammable substances get inside the camera. It could cause fire, short-circuits or damages.
Be careful when handling the unit To prevent damage, do not drop the camera or subject it to strong shock or vibration.
Install away from electric or magnetic fields
Protect from humidity and dust
Protect from high temperature
Be careful when installing close to the ceiling , in a kitchen or boiler room, as the temperature may rise to high levels.
Cleaning Dirt can be removed from the case only by wiping it with a soft cloth moistened with a soft detergent solution.
Mounting Surface The mounting surface material must be strong enough to support the camera.
TROUBLESHOOTING
Before sending the camera out for repair, check the items below. If the problem persists after checking these items, contact your service center.
If no image appears
Is the coaxial cable attached securely? Are the power and voltage normal? Has the iris of the lens inside the camera been adjusted correctly (with the level volume) ? Is there adequate illumination?
If the image is unclear
Is the lens in focus? Is the lens dirty? Dirt or fingerprints on the lens can adversely affect the images. Gently wipe any dirt or fingerprints off the lens with a soft cloth or lens cleaning paper and cleaning fluid (commercially available). Is the monitor adjusted correctly?
WARNING:
TO PREVENT THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.
LENS ADJUSTMENT
1. Adjust the panning (360˚) and tilt (90˚) position.
2. Set the zoom position by using Zoom Lever Screw.
3. Set the focus by using Focus Lever Screw.
4. Loosen set screws (using small M1.0 Hex L-wrench provided) to adjust roll
(turns camera position top/bottom).
PAN ROLL
SET SCREW
(2X)
TILT
90˚
ZOOM
FOCUS
SPECIFICATION - V700-C SERIES
General Spec NTSC PAL CCD Type 1/3" 410K Pixels Color 1/3" 470K Pixels Color Total number of pixels 811(H) X 508 (V) 795(H) X 596(V) Min illumination Video Output Resolution S/N Ratio Shutter speed 1/60~1/100,000sec 1/50~1/100,000sec Sync System White Balance OSD Control DNR OFF, LOW, MIDDLE, HIGHT SENSE_UP OFF/AUTO (X2 ~ X256) AWB MIRROR OFF/MIRROR/V_FLIP/ROTATE PRIVACY 6 ZONE / SIZE
Power Input Video Output
Voltage Power Consumption
Operation temp In storage temp Operation humidity
0.013 fc (0.14 Lux ) @ F1.2, 30IRE
1.0Vp-p/75 ohm Composite
560 TV Lines
50dB (AGC off)
Internal / External
Connector
2 WIRE
BNC Cable
Electric Spec
Auto
ATW/ AWC/ MANUAL/ PUSH LOCK
Under 90 (Non-condensing)
Mechanical Spec
14 ~ 131° F (-10 ~ 55° C)
-4 ~ 158° F (-20 ~ 70° C)
DC 12V (11V ~ 16V) AC 24V (20V ~ 28V)
DC 12V : Max 1.8 [W] AC 24V : Max 2.4 [W]
CONNECTIONS
CAUTION
The use of a UL Listed Class 2 power supply is required to ensure
compliance with electrical safety standards. Check for polarity when using a 12VDC power supply.
12VDC-24VAC
12VDC-24VAC
RED (+)
BLACK (-)
11.8in (300mm)
RED (+)
BLACK (-)
VIDEO
VIDEO
Cable for connection to portable monitor, provided. When using a portable monitor, terminate at 75ohms (at last device).
Surface-Mount Base
In-Ceiling Base
CAMERA SETTINGS FOR V700-C SERIES
CAMERA SETTINGS
FUNCTION OF CONTROL BOARD
[1]. SW
Functional control of O.S.D (On Screen Display)
[2]. CON1
Second Video output connector
[3]. CON2
RS-485 connector
CON1
SW
CON2
OSD MAP
LENS MASK 1 E. SHUTTER MASK 2 BLC MASK 3 MAX_DR MASK 4 AGC MASK 5 SENSE_UP MASK 6
WB MODE SYNC MODE
R-Y GAIN V_PHASE B-Y GAIN
D&N MODE CAMERA ID C-SUP TITLE A-SUP DPC
MONITOR LANGUAGE BAUDRATE
OMNI LENS
MIRROR EXIT SHARPNESS SAVE & EXIT GAMMA FACTORY SET FREEZE NEGA 3D_DNR D_ZOOM SLC HME
DIS
MOTION SET WINDOW ALL SET ALL CLEAR SENSITI
SHOW INDI
DELAY OUT
9. EXIT
5. MOTION
6. PRIVACY
2. COLOR
7. SYNC
3. DAY&NIGHT
8. SETUP
4. FUNCTION
1. EXPOSURE
INSTALLATION
The V700-C can be either mounted to a surface (like a ceiling or
wall) or installed into the ceiling, with or without an electrical box.
1 Use the large (Torx T20) L-Wrench to loosen the 4 screws (B) securing
the dome assembly.
2 For surface-mount installations, align the mounting base (D) with the
mounting surface; mark the mounting screw holes and then drill the four holes. For in-ceiling installations not mounting to a 4x4 electrical box, mark the holes in the camera assembly (C) and then drill the holes. For in-ceiling installations, (D) is not used.
3 For in-ceiling installations, cut a hole (diameter: 2.9 in./73 mm) in the
ceiling for routing the cables. 4 Route the power cable(s) and video cable(s) to the installation location. 5 Align the four mounting holes in (D) with the holes in the ceiling.
Using the four screws and anchors provided (G), if appropriate for
mounting surface, fasten the mounting base to the wall/ceiling. Using
the other four screws provided, secure the camera assembly (C) to the
mounting base. For in-ceiling installations, align the holes in (C) with
the holes drilled in the ceiling and secure the camera assembly with
the hardware provided, if appropriate. If installing to an electrical box,
secure (C) with the screws provided. 6 Pass the power cable (E) and video cable (F) from the camera unit
through the cable hole in the ceiling. For surface-mounted units,
cabling is routed through the knockout hole in the side of the unit. 7 Carry out the settings and adjustments for the camera previously
described. 8 Secure the dome assembly (A) by tightening the screws (B).
Vicon Industries Inc.
Corporate Headquarters
89 Arkay Drive
Hauppauge, New York 11788
USA
631-952-CCTV (2288) 800-645-9116
Fax: 631-951-CCTV (2288)
European
Headquarters
Brunel Way
Fareham, PO15 5TX
United Kingdom
+44(0) 1489 566300
Fax: +44(0) 1489 566322
Vicon Germany
Kornstieg 3
D-24537 Neumuenster
Phone: +49 (0) 4321 8790
Fax: +49 (0) 4321 879 97
Internet Address: www.vicon-cctv.com
Vicon Part Number 8009-8178-01-00 Rev 310
Far East Office
Unit 5, 17/F, Metropole Square
2 On Yiu Street, Shatin
New Territories,
Hong Kong
(852) 2145-7118
Fax: (852) 2145-7117
© Copyright 2010, Vicon Industries Inc.
Loading...