Vibra-Tite 308 Technical Data

Page 1
Cyanoacrylate
Product Description
Base Compound
Ethoxyethyl
Appearance
Colorless Liquid
5 cP
Specific Gravity (g/cc)
1.06
Flash Point (TCC)
176°F
1 year unopened
°
Steel
5 to 10 seconds
Aluminum
7 to 14 seconds
Neoprene
< 8 seconds
ABS
5 to 10 seconds
Polycarbonate
10 to 20 seconds
PVC
5 to 10 seconds
Polymer (Cured)
Appearance
Colorless Solid
Service Temperature Range
Softening Point
Refractive Index
1.49 Full Cure Time
24 Hours
Dielectric Strength (KV/mm)
12.6
Dielectric Constant (@ 1Kc)
5.4 COE (in./in./F)
.000126
Tensile Strength
2400 psi
Solubility
Nitromethane,
Dimethylformamide
Substrate
Range in N/mm2
Blasted Steel
16 to 20
Etched Aluminum
11 to 18
Neoprene
> 10
ABS
>6
Polycarbonate
>5
PVC
>6
Strength at Temperature
0.00
20.00
40.00
60.00
80.00
100.00
0 60 80 100 120
Temperature , C
% Retained
308

Vibra-TITE 308 is a single component, low viscosity cyanoacrylate adhesive. No-odor and non-blooming characteristics make this product user friendly when vapor control is an issue.

Monomer (Liquid)
Viscosity (cP @ 68°F)
Shelf Life @40°F

Military Specifications

Curing Properties

Ambient surface moisture will initiate the hardening process. Handling strength is reached in a short period of time and varies depending on environmental conditions and substrates being bonded. Product will continue to cure for at least 24 hours before full strength and resistances are developed.

Physical Properties

Cyanoacrylate
Product Data Sheet
-65°F to 200°F
293°F
(ND 20)
(steel/steel)
Acetone,
Performance of Cured Materials
Tensile Shear strength after 48 hours at 20° to 25°C
Setting Time (68

Curing Performance

The gap of the bond line will affect set speed. Smaller gaps tend to increase the speed. Activators can be applied to improve set speed but may also impair overall adhesive performance.
F, 65% R.H.)
Temperature Resistance
Sheer Strength on steel after 1 week at 22 °C
Page 2
Cyanoacrylate

Chemical Resistance

% Strength Retained
Motor Oil
100
Gasoline
100
Tricloroethane
100
Freon TA
100
10% NaOH
0
10% Hcl
0
Water
0
For safe handling information on this product,
F pr ovides opt imum storage
or g rease. P roducts like isopropyl alcohol c an be u sed.
ch as a teaspoon handle.) In case of eye
contact, b athe i mmediately with water a nd s eek
308
Sheer strength on steel after 12 month soak
Solvent

General Instructions

Surfaces to be bonded should be clean and dry. Dispense a drop or drops to one surface only. Apply only enough to leave a thin film layer after compression.
Press parts together and hold firmly for a few seconds. Good contact is essential. An adequate bond develops in less that one minute and maximum strength is attained in 24 hours. Wipe off excess adhesive from the top of the container and recap. Cyanoacrylate products if left uncapped may deteriorate by contamination from moisture in the air. Because Cyanoacrylate products cure by polymerization, whitening may appear on the surface of the container or the bonded materials. Should this happen, wipe surfaces well with acetone.
Product Data Sheet
consult the Material Safety Data Sheet, (MSDS)
General Information
Storage
Refrigeration at 4 0° stability.
Note
Prior to use, remove all surface contaminants such as oil
Test compatibility of cleaner with substrate. Make sure surface is completely dry before bonding.
Health & Safety in use
CAUTION: SuperGlues b ond s kin a nd e yes o n c ontact. If acci dental skin bonding occurs, wash area with warm soapy water a nd s lowly p ry s kin a part us ing a b lunt object (su
immediate medical attention.