Vibe Labs SP SERIES, SP2000, SP4000 User Manual

SP SERIES
Digital Power Amplifiers
Page 2
SP Series User Manual
IMPORTANT SAFETY INFORMATION
Read instructions — All the safety and operating instructions should be read before the product is operated.
Retain instructions - The safety and operating instructions should be retained for future reference.
Heed Warnings — All warnings on the product and in the operating instructions should be adhered to.
Follow Instructions — All operating and maintenance instructions should be followed.
AC Power Supply — Connect the product only to a properly sized and fused AC supply circuit of the correct voltage.
Grounding — Use only with a proper Earth ground and the supplied 3 conductor power cord.
Power Cord Protection — Power cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them. Pay particular attention to plugs and the point from which the cords exit the product.
1.
2.
3.
4.
5.
6.
7.
Cleaning — Unplug this product from the wall outlet before cleaning. Do not use liquid or aerosol cleaners.
Disconnect — The product should be disconnected from the power supply during power outages, lightning storms or when unused for long periods of time.
Moisture - The product should be protected from moisture and should not be used in or near water.
Service and Repair — Refer all service and repair as required to qualified service personnel. Do not attempt repair.
Ventilation — Ensure that the product is installed where adequate airflow is present and that the ventilation openings are unobstructed.
Placing or Moving — Do not place on an unstable cart, stand, bracket or table. The product may fall, causing serious injury to a child or adult, and serious damage to the product. A product and cart combination should be moved with care. Quick stops, excessive force, and uneven surfaces may cause the product and cart combination to overturn.
Cover — To prevent the possibility of electrical shock do not remove the cover.
8.
9.
10.
11.
12.
13.
14.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.
FCC Part 15 Compliance
Page 3
SP Series User Manual
Welcome to Vibe Labs
Thank you for investing in the SP Series of professional power amplifiers from Vibe Labs! Your trust is well placed in what we believe to be one of the best specified, best designed and best built digital power amplifiers available. We have spent countless hours poring over the many details that make up a sophisticated product like the SP series to ensure that you enjoy many years of flawless performance.
Please take the time to read through this User Manual in order to fully appreciate all of the features and benefits of the SP series. Or, if you are experienced go ahead and read over the Quick Start on page 4. Ultra-seasoned “road dogs” might be tempted to skip even those instructions. If that’s the case then at least please check these two items so that we don’t blow anything up:
1. Make sure the AC VOLTAGE SWITCH is set correctly for your region.
2. Do not connect a BRIDGED MONO load to the amplifier; it will fail immediately.
Now if you’d like to discover all of the other features such as the switchable noise gate, auto-mute gain control and security lock functions or you’d like more information about controlling and monitoring the amplifier from a computer, then you’d best read on. The SP series has a lot to offer and we want you to get the very most out of it.
Finally, I’d like to encourage you to think about how you may be able to reduce your carbon footprint in this age of environmental awareness. At Vibe Labs we’ve made a commitment to become carbon neutral by reducing, re-using and recycling. While we can’t do it alone we know that every little bit helps. You can do your part by turning off devices (including this amplifier) when not in use. It’s only one small step but it will make a difference.
Thanks again for putting your trust in Vibe Labs.
Sincerely
Costa Lakoumentas
Founder & CEO
Page 4
SP Series User Manual
QUICK START GUIDE
It is strongly recommended that you read this User Manual in its entirity. However if you need to get up and running immediately please observe the following :
<2 OHMS
Do not connect speakers with a total load impedence of less than 2 Ohms per channel.
2.
BRIDGE
Do not bridge the amplifier outputs.3.
12
3
Pin 2 (+)
Pin 3 (-)
Pin 1 (S)
Balanced XLR
Left (+)
Balanced Euroblock
Connect input signals.4.
Adjust gain as needed.6.
115
VibeNET
IN OUT
OUTPUTS
Check the voltage select switch and make sure it is set correctly for your region.
1.
Connect to AC power and turn amplifier ON.5.
Set the MUTE PROTECT mode as described on Page 16 of this manual.
7.
Page 5
SP Series User Manual
SP series power amplifiers combine sophisticated digital signal processing with high-efficiency Class D power amplification for a wide range of professional audio applications. Included VibeNET™ SP software allows complete control over all signal processing, gain and test functions as well as real-time monitoring of levels and temperature from a connected PC either by USB or Cat5 cabling.
SP Series amplifiers may be operated on either 115VAC or 230VAC. The correct voltage is selected on the rear panel through the voltage select switch. While all amplifiers are set correctly at the factory for their intended destination country you are advised to confirm the setting before connecting the amplifier to the power supply for the first time.
AC Voltage Select
115
VibeNET
IN OUT
OUTPUTS
This product is designed to be connected and used only as recommended in this User Manual. To ensure electrical safety it must be connected to a properly rated and fused AC power supply that is grounded. Do not connect to a power supply that is ungrounded or where the power cord is missing the ground connection.
1. INTRODUCTION
2. UNPACKING & INSPECTION
The shipping carton contains:
SP series amplifier Printed copy of this user manual IEC AC power cable Two Euroblock Input connectors One Euroblock Output connector One USB cable One CD-ROM with VibeNET software
The amplifier should be checked for any damage that may have been caused in transport. Verify that all of the components are in the box. Please consider recycling the carton.
3. SAFETY
4. AC VOLTAGE
© Copyright 2009, Vibe Labs, Inc.
Vibe Labs™ is a trademark of Vibe Labs, Inc.
All other trademarks used in this manual are the property of their respective owners.
No part of this manual may be copied, reproduced, scanned or posted witout the express
written permission of Vibe Labs, Inc.
Page 6
SP Series User Manual
1. Carrying handles.
2. Air vents – DO NOT BLOCK!
3. Display bezel.
4. LCD display screen.
1 32 4
5 6 7 8
5. AC power switch.
6. Channel A Gain control / Setup encoder.
7. Channel B Gain control / Setup encoder.
8. USB connection point (to computer).
5. FRONT PANEL
Loading...