Viaanix VELORA102 User Manual

VELORA102
General Features
On-board proprietary protocol stack
command interface over UART
Compact form factor: 32.5 mm diameter
Castellated SMT pads for easy and reliable PCB mounting
Environmentally friendly, RoHS compliant
FCC Certified
manual
Operational
Single operating voltage: 2.1V to 3.6V (3.3V typical)
Temperature range: -40°C to +85°C
Low-power consumption
Programmable RF Communication Bit Rate up to 5468 bps with LoRa™ Technology
modulation
Integrated MCU, Crystal, Programmed 64 bit unique address, Radio Transceiver with
Analog Front End, Matching Circuitry
GPIOs for control and status
RF/Analog Features
Low-Power Long Range Transceiver operating in the 915 MHz frequency band
High Receiver Sensitivity: down to -148 dBm
TX Power: adjustable up to +20 dBm high efficiency PA
LoRa Technology modulation
IIP3 = -11 dBm
>1 mile coverage at suburban and >0.5 mile coverage at urban area
Description
Viaan Electronics’ Low-Power Long Range LoRa Technology Transceiver module provides an
easy to use, low-power solution for long range wireless data transmission. The advanced
command interface offers rapid time to market. The VELORA102 module has proprietary
software to allow for secure messaging between devices. The module is also prepared for
LORAWAN Type A data transfer.
It integrates RF, a baseband controller, command Application Programming Interface (API)
processor, battery or external power making it a complete long range Solution. The
VELORA102 module is suitable for simple long range sensor applications with external host
MCU or standalone.
Applications
Automated Meter Reading
Home and Building Automation
Wireless Alarm and Security Systems
Industrial Monitoring and Control
Machine to Machine
Internet of Things (IoT)
Federal Communication Commission Statement (FCC, U.S.)
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operation.
FCC Caution:
Any changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate this equipment.
IMPORTANT NOTES
Co-location warning:
This transmitter must not be co-located or operating in conjunction with any other
antenna or transmitter.
OEM integration instructions:
This device is intended only for OEM integrators under the following conditions: