16.1 What to do in case of system failure ............................................................75
16.1.1 Behaviour of the system in case of unforeseen shutdown ...............................75
16.1.2 Emergency lever and how to overcome faults during navigation in case of system
with mechanical interface .............................................................75
16.1.3 Self-protection in case of overload or breakage of the push-pull cables .................76
16.2 Analysis of the electronic system behaviour ....................................................77
16.3 Diagnosis through the command station ......................................................79
17 Drilling mask for command stations .................................................................80
17.1 Command station series EC3 ..................................................................80
17.2 Command station series EC4 ..................................................................81
18 Drilling mask for actuator ...........................................................................82
vetus® Electronic engine remote control
030624.135
Page 6
1 Introduction
This manual describes the electronic remote control system in general and its operating, performance and safety aspects.
If it is the first time that you install a VETUS electronic control system, go to the next section where you will be guided to
the necessary steps.
1.1 How to start
Once you have received the system package, follow these steps:
1) identify all the components necessary to build up your system with the help of instructions at sections 4, 5, 6 and
report all the relevant data in the frame here below
2) identify your installation type with the help of section 7.
3) configure the CANBus network, set dip-switches and end of line termination of actuators and command stations, as
described at section 7.6
4) mount command stations and actuators with the help of drilling mask (section 17)
5) make electrical wiring (section 8)
6) install push-pull cables, if your application requires it (section 10)
7) make setting of mechanical strokes, if your application requires it (section 11, 12 and 13)
8) program the actuator specific installation parameters (from section 11 to section 16 included)
9) make the programming of the options, if your application requires it (section 15)
10) once you have set-up the electronic system, read the pilot’s instruction (section 3). Good navigation!
1.2 System configuration and installer remarks
ComponentPosition aboardSerial number
Command station 1
Command station 2
Command station 3
Actuator left engine
Actuator right engine
Boat registration number
Date of installation
Name and signature of
authorized installer
6030624.13
vetus® Electronic engine remote control
Page 7
2 General installation features
2.1 Description of the system and its parts
The electronic engine remote control implements mechanical and electronic solutions with digital communication technology. Only few devices are required to compose a complete electronic engine remote control:
• Command stations
• Actuators
• Data communication cables which connect the Command Stations to the Actuators
2.2 Maximum extension of the system
The maximum configuration of the system is as shown in the following table:
ActuatorsThe maximum number of engines that the system can control is 2
Command stationsThe maximum number of Command Stations is unlimited
80 metersMaximum distance between cockpit and engine room
2.3 System performance
Temperature
Operating temperatureFrom -10 to 85°C
Storage temperatureFrom -40 to 90°C
Humidity max operating limit: 90% (relative humidity)
Protection degree of main system components
Command Station series EC3IP 66
Command Station series EC4IP 67
ActuatorIP 54
Mechanical features
Nominal load when actuator is providing a pushing force150 N (15 kg) with power consumption 1.5 A
Max load when actuator is providing a pushing force450 N (45 kg) with power consumption 5 A (with time <1 s)
Stroke of gearbox – forward
Stroke of gearbox – reverse
Throttle stroke Stroke can be set between 30 and 80 mm
Stroke can be set between 15 and 40 mm
Electrical features
Power supplyfrom 9 to 28 Vdc (for standard installations)
from 20 to 28 Vdc(for special installations)
Max. current absorbed5 A
Current absorbed when the system is in standby0,5 A
vetus® Electronic engine remote control
030624.137
Page 8
3 Pilot instructions
In the VETUS electronic control system can be mounted any of the following command stations: EC3- EC4. Depending
on the system configuration and on the type of command station, the latter can be used for the command of one or two
engines. Here below are reported the instructions for some types of levers: although the functions are the same, due to
the command station’s construction, push buttons, LEDs and keypads might look slightly different. For more detailed
information look at the specific command station product instruction.
Each command station repeats the functionality of a traditional mechanical lever. Moving the lever from the neutral position, after an angle between 16° and 20° forward or reverse (it depends on the lever’s type),automatically the electronic
system clutches-in respectively the forward or reverse gear. It follows then the lever’s stroke in forward and backward
direction for the throttle control.
Command station EC3
Command station EC4
Max.
Throttle
Reverse
62°
Reverse
Min.
Min.
Neutral
16°
Neutral
20°
Forward
Min.
16°
62°
Max.
Throttle
Forward
Min.
20°
8030624.13
Max.
Throttle
62°
62°
Max.
Throttle
vetus® Electronic engine remote control
Page 9
3.1 Control keypad
On each command station are mounted an electronic keypad, push-buttons and LEDs.
In installations with single engine(*), both the green LEDs are referring to the same engine. In systems with 2 engines the
push button and the green LED on the right are referring to the starboard engine while the push button and the green
LED on the left side are referring to the port engine.
Command station EC3Command station EC4
without trim optionwith trim option
Trim
vetus
Engine
Warm/Sync
Engine
Command
Engine
Warm/Sync
Engine
Command
DescriptionLEDs colour
Engine (*)Green
Warm/SyncYellow
CommandRed
Engine (*)Green
(*) In installations with single engine, both the green LEDs are referring to the same engine. In systems with 2 engines
the push button and the green LED on the right are referring to the starboard engine while the push button and the
green LED on the left side are referring to the port engine.
vetus® Electronic engine remote control
030624.139
Page 10
It follows the table with the definition of LED and push buttons.
Push-buttonLEDDescription
EngineThe left LED is for the port (left) engine, while the right LED is for the star-
board (right) engine. If the LED has a fixed light on (green), the corresponding gearbox is in neutral position.
If the LED is blinking (green), the lever on the LED’s side is synchronised
with the lever of the station that at the moment has the Command.
CommandIf it is switched off, the Station has not the command.
If is switched on, the Station has the command.
Warm/SyncIf it is blinking, the navigation system is in Warm-up mode; this means that
the engines can be accelerated without clutching-in the gear.
If the LED is fix lighted, the system is in Synchro mode.
Warm/SyncWhen both the levers of the Station that has the command are in neutral
position, if you press for 1,5 seconds the button Warm, it is activated the
function Warm-up.
CommandIf you press Command for 1,5 seconds the station takes the command, only
if one of these two conditions are respected:
- both the lever of the station are in neutral
- both the lever are synchronized with respect to the levers of the station
that at the moment has the command
All LEDs are lighted onThe control system isn’t working correctly
3.2 Acquisition of the command
It is possible to acquire the command of the boat from any Station in the following cases:
• The boat isn’t moving
1. Position both the levers in neutral and press Command for 1,5 seconds.
2. LED “Command” is now lighted on while the warm/synch LED is blinking. You are in Warm-up mode: throttle command is enabled but clutch command is disabled.
3. To enable the command of the gearbox you must press for 1,5 seconds the Warm/Sync push-button
• In navigation
1. Synchronize the 2 levers of the Station which wants to acquire the command with respect to the Station which has
the command.
2. When LEDs “Engine” of the station which wants to acquire the command are blinking, these levers are synchronised
with the levers of the station which still has the command.
3. By pressing the pushbutton Command for 1,5 seconds, the new station takes the command.
Important: before taking the command, proof that all the passengers are safely on board.
3.3 Engine Warm-up
If both levers are in neutral, by pressing for 1,5 seconds the button Warm/Sync of the Station which has the command,
you enter in Warm-up mode. If you move the lever, it is only affected the accelerator but not the gear.
In Warm-up mode the LED Warm/Sync is blinking.
After positioning again both levers in neutral and pressing for 1,5 seconds the Warm/Sync, the system comes back to the
normal operation mode.
10030624.13
vetus® Electronic engine remote control
Page 11
3.4 Synchro mode
It is possible to command both engines at the same speed and direction with only one lever. This function can be activated only by the station which has the command.
With both levers in neutral position, press at the same time for 1,5 seconds the two “engine” push-buttons. The command
of both engines is now on the right lever. In Synchro operation mode, the LEDs “Warm/Sync” and “Command” are lighted
on.
From “Synchro” operation mode, if you position both levers in neutral, and press contemporaneously for 1,5 seconds the
two “Engine” push buttons, the command of each engine is again assigned to the respective lever and LED “Warm/Sync”
is switched off.
Synchronisation or de-synchronisation can be performed on the station which has the command, in case the RPMs between the two engines don’t differ more than 10%.
3.5 Fast Start-up Mode
This function is available on the first command station as described in section 7.6of this manual. When the configuration
FSM (Fast Start-up Mode) is enabled, the station with the FSM enabled, takes automatically the command at the power
on, only if both its levers are in neutral position.
If the station is not in neutral position, it will take the command as soon the neutral position will be reached by both its
levers.
3.6 Emergency lever
In case of emergency, the electronic system can be switched off quickly and the engines and gearboxes can be operated
directly by the mechanical emergency levers. If you have the connector panel in front of you, the right emergency lever
is for gearbox, the left emergency lever is for engine.
Emergency levers are fitted on the
control box. During the normal
functioning, the indexing plunger
device “A” is positioned as shown in
the picture on the left. In emergency situation, to unlock the mechanism it is enough to rotate of 180°
the plunger “A” from its working
position. After this operation, the
mechanism (and the related pushpull cable) can be operated manually using lever (B).
In order to engage again the system you must:
1. Rotate or assure that the mechanical indexing plunger device “A” is in lock position (like in the picture)
2. Place the emergency lever “B” in the centre of stroke and move it back and forward until you hear a “click”.
3.
Verify that after the “click” the lever is engaged (you cannot move it freely by hand). In case the emergency lever is still
free, repeat operations from point 1 to 3.
vetus® Electronic engine remote control
030624.1311
Page 12
4 Command station
Command stations are classified as devices for the control of one or two engines, with or without trim/flap command.
After serial number 18500 there can be mounted in the same installation an unlimited number of command stations,
before serial number 18500 the number of command stations in the same installation is limited to 3; for detailed information look at section 7.7.
Depending on the application, it is very important to set the dip-switches present on the bottom part of the command
station, as described in sections 4.4 and 7.6 of this manual.
How to mount the Command Station
Command stations cannot be directly or indirectly mounted onto sources of vibrations. At chapter 17 of this manual you
find the drilling mask drawings.
4.1 Dimensions
4.1.1 Command station EC3
155 (6 1/8”)
”)
8
/
7
155 (6
1
/8”)
”)
16
/
3
132 (5
174 (6
ENG IN E 1
114 (4 1/2”)
COM M AN D
20
ENG IN E 2
43
”)
16
/
11
(1
”)
16
/
13
(
35
3
”)
8
/
(1
4 x M5
WAR M /S
Important: in case the screws to fix command station to the dashboard panel are not long enough, don’t open the command station to replace them but ask for an adaptation kit.
4.1.2 Command station EC4
142 (5 9/16”)
12030624.13
”)
16
/
5
160 (6
”)
2
/
1
114 (4
”)
8
/
3
35 (1
25.4 (1”)
62 (2 7/16”)
100 (3 15/16”)
”)
16
/
15
75 (2
40
9
”)
16
/
(1
107.5 (4 1/4”)24.3 (15/16”)
152 (6”)
vetus® Electronic engine remote control
Page 13
4.2 Friction adjustment
4.2.1 Command station EC3
To adjust the inner friction of the command lever, remove
the PVC cap (A) and unscrew the fixing screw (B). It is possible to adjust the friction screwing and unscrewing the inner
screw placed into the hole. When the regulation will be done,
mount the screw and the plastic cap.
B
C
A
4.3 Programming of the command station
4.3.1 For command stations before serial number 18500
At power up, the command station makes a sequence of two flashes. The first flash identifies the number of engines and
the second identifies the number of actuators present in the system. According to the length of each flash, the command
station is differently configured.
You need to configure the command station in relation to the type of installation. It is also possible to modify the configuration of the command station by keeping pressed before powering up and continuing to keep them pressed for 6
seconds after power up, the following push buttons:
• Warm/Sync + Command, in this case you want to change the number of actuators
• Engine left + Engine right, in this case you change the number of engines on the boat
Possible configurations are according to the following table:
1° flash (identifies the number of motors)2° flash (identifies the number of actuators)
Installation with 1
engine and 1 actuator
Installation with 2
engines and 1 actuator
Installation with 2
engines and 2 actuators
Important: from the factory, the command station is configured with the first flash short and the second flash long.
1. To configure the command lever for an installation with 2 actuator boxes, press the push buttons Warm/Sync and
Command before powering up the command station and continue to keep them pressed for 6 seconds. The lever is
now configured for installations with two engines and two actuators. At the next normal power up, the command
lever will make a sequence of 2 short flashes.
2. In case you need to configure again the command lever for installation with 2 engines and 1 actuator, repeat the
procedure of point 1.
Long (3 seconds)Long (3 seconds)
Short (less than 1 second)Long (3 seconds)
Short (less than 1 second)Short (less than 1 second)
vetus® Electronic engine remote control
030624.1313
Page 14
4.3.2 For command stations after serial number 18500
At power-up, the command station emits a sequence of flashes that depends on the type of station (single or double)
and on the status of the DIP-SWITCH 2. The possible behaviours of the command station are the following:
Step 1: if the station is single lever all the LEDs remain ON for 2s before moving on to the next state; if the station is
double lever, all the LEDs remain ON for 0.25s before moving on to the next state
Step 2: if the DIP-SWITCH 2 is ON, there is this further sequence of flashes: the two central LEDs (Command and
Warm-Up) are turned on for 0.25s and then the two side LEDs (Engine) stay ON for another 0.25s. Otherwise the
station goes to the next state
After step 1 and step 2 the station will perform with the normal LEDs management, based on station and system status.
Step 1Step 2 (only if dip-switch 2 = ON)
1° flash
Installation with 1
engine
Installation with 2
engines
(identifies the number of
engines)
Long (2 seconds)
Short (less than 0,25
second)
CMD and WARM-UP light
CMD and WARM-UP light
2° flash3° flash
ENGINES light on
on (0,25 seconds)
ENGINES light on
on (0,25 seconds)
(0,25 seconds)
(0,25 seconds)
Note: the number of flashes corresponding to the number of actuators present in the system (as depicted in
section 4.3.1.) is no longer executed.
4.3.3 EC4 two-engine stations: how to assign the Synchro function to the operating lever (after serial
number 18500)
By default the Synchro function is assigned to the left lever. It is possible to change or assign the Synchro function either
to the left or to the right lever, following the instructions here below:
1. activate the Synchro as usual
2. bring both levers in neutral
3. press the two push-buttons on the side of the lever that you want to use for the Synchro:
“Engine” left and “Syncro / WarmUp” for the left lever
“Command” and “Engine” right for the right lever
4. keep the push buttons pressed for at least 10s
5. if the operation is successful, the LEDs pair corresponding to the push buttons pressed will flash
The programming is then stored in the device memory. The operation must be repeated for all the control stations of the
system.
14030624.13
vetus® Electronic engine remote control
Page 15
4.4 Command station label
There is a label under the base of the command station.
This label shows the code and the serial number of the command station. The dip-switches configure the control station
on the base of its position in the CANBus network. The dip switch selector is represented with a small black square.
Command station 1, Command station 2, Command station 2 and Command station FSM are different addresses on the
CANBUs network.
If there are multiple stations in the same system, each one must have a different address. “Command station FSM” and
“Command station 1” cannot coexist in the same installation. “Command station FSM” is an alternative to “Command
station 1” and vice versa.
Chapter 7 lists the most common types of systems, which can only be configured with a correct dip-switch setting. 4.5.
Trolling option
DIP switch configuration
Command station 1
Command station FSM
Command station 2
Command station 3
CodeS/N
1234
Trolling
Line termination
ON
OFF
Address
Dip-switch configuration details
Command station 1
Command station FSM
(Fast Start-up Mode)
Command station 2
Command station 3
ON
OFF
4.5 Trolling option
To activate the Trolling function, dip-switch 2 must be set to ON. For specific information refer to the document “Trolling_Flap option for lever EC3 & EC4”.
vetus® Electronic engine remote control
030624.1315
Page 16
4.6 Trim/Flap option
Trim/flap command can be activated directly from the command station with the buttons ‘+’ and ‘-’. The commands are
sent to the actuator from the command station. The relay card fitted on the actuator activates the hydraulic pump of the
trim/flap.
For installations with two engines, in case of “Synchro” mode operation, the buttons on the right-hand side operate the
both the trims (or the flaps) simultaneously.
Command station EC3
Version for one engineVersion for two engines
Command station EC4
Version for one engine
Trim or flap can be activated
directly from the command
station with “+” and “-“ pushbuttons. These pushbuttons are
placed on the lateral side of the
left lever.
Version for two engines
Trims/flaps are tuned with “+” and “-“ pushbuttons placed on the keypad (a couple
for each engine).
It is also possible to command the trims/flaps in Synchro with the “+” and “-“ push
buttons placed on the left lever.
Trim
+
Engine
Engine
16030624.13
Warm/Sync
vetus® Electronic engine remote control
Command
Page 17
4.7 Advices about the mounting and preservation of the Command Station
In case of outdoor installation, being the command station not designed to be submerged by water, to be exposed directly to water jets, or to be cleaned with pressurized water/steam, please notice:
• Command station cannot be installed in areas where water can be retained or where there is the potential risk of creating water puddles.
• Command station cannot be submerged or directly exposed to waves or water jets.
• Command stations are made of materials resistant to marine environment; in any case, it is essential to remove periodically salt deposits on the external surfaces to avoid corrosion and consequentially system inefficiency.
• It is not allowed to clean the command station
with hydro-cleaner or any watering directly to
the command station.
• Do not use aggressive chemicals for cleaning
the command station.
• When not in use, put on the command station
the protection cover. In case the cover is not
included into the supply, it is possible to order
it separately.
4.8 Command station codes
Command stations
DescriptionCode
Command station 1 motor EC3 EC3H1
Command station 1 motor EC3 with TRIM optionEC3HT1
Command station 2 motors EC3EC3H2
Command station 2 motors EC3 with TRIM optionEC3HT2
Command station 1 motor EC4EC4H1
Command station 1 motor EC4 with TRIM optionEC4HT1
Command station 2 motors EC4EC4H2
Command station 2 motors EC4 with TRIM optionEC4HT2
vetus® Electronic engine remote control
030624.1317
Page 18
5 Actuator
With reference to the type of engine and gearboxes, with or without trim/flap, actuators are classified as follow:
• mechanical
• electronic
• mechanical & electronic
It follows the drawings of the different types of actuators. In the last page of this manual you find the footprint of the
actuator in scale 1:2.
5.1 Drawing of actuators with mechanical interface
34°
34°
213,5 (8 3/8”)
142,5 (5
Connectors area
5
/8”)
ø 20
11
1
7
/8”)
/16”)
/4”)
286 (11
200 (7
170 (6
130 (5 1/8”)
25
(1”)
”)
”)
16
16
/
/
13
300 (11
”)
15
8
/
3
354 (13
390 (15
”)
4
/
3
(
18030624.13
Shocks absorber
vetus® Electronic engine remote control
Page 19
5.2 Drawing of full electronic actuator
3
35 (1
/8”)
11
170 (6
/16”)
Trolling
142 (5 9/16”)200 (7 7/8”)
Trim/Flap
Gear
Neutral switch
”)
16
/
15
13
354 (13
”)
16
/
300 (11
Connectors area
Gear
Neutral switch
Throttle
Left engineRight engine
+12 V
+24 V
Fuse
Throttle
Canbus
Trolling
Trim/Flap
5.3 How to mount the Actuator
The actuator must be mounted in the engine room in a safety place and as near as possible to the propulsion engine. The
actuator cannot be exposed directly to the source of vibrations, e.g. it cannot be mounted directly on the engine, on the
gearbox or on the engine base.
Mount the actuator leaving a space of at least 25 cm on each side
A > 25cm (10”)
A > 25cm (10”)
A
A
A
vetus® Electronic engine remote control
A
Do not install the actuator
with the connectors upwards
A
A
030624.1319
Page 20
5.4 Electronic Actuator Boards
5.4.1 Actuator board ver. 3.1
21
JP8JP3JP18JP17JP16
Fuse
JP7
JP12
JP11
JP13
JP14
JP15
DOWN
UP
JP2
JP1
JP10JP9JP6
JP19
JP5
ENTER
Position on boardPinDescriptionOutput cable
JP8 Supply
JP9 Engine right
JP10 Engine left
2
3V_out CH2
1GND CH2
4GND CH1
2
3V_out CH4
1GND CH4
4GND CH3
1Vdc
2GND
V_out CH1
MOD2 (Rev.3)
V_out CH3
MOD2 (Rev.3)
Wall connector
4 poles
4 poles
Connectors JP9 and JP10 are dedicated to the electronic control engine device (ECU).
20030624.13
vetus® Electronic engine remote control
Page 21
5.4.2 Relays PCB version RB 1.0 for TRIM-FLAP and neutral relays
Fuse
Pin Description
1Vdc
2GND
3Vdc
4(Not used)
5
6Trim +
7Trim -
8Trailer
9Common neutral relays contact
10NO contact neutral relay
11NC contact neutral relay
12(Not used)
13(Not used)
14(Not used)
15(Not used)
16(Not used)
17(Not used)
18
19NO contact neutral relay
20NC contact neutral relay
21Common trim contact
22Trim +
23Trim -
24Trailer
Left engine
Right engine
Trim common contact
Common neutral relay contact
4211019876521232221201918
vetus® Electronic engine remote control
030624.1321
Page 22
5.4.3 Relays PCB version 2.0 for electronic gearboxes
Fuse
5
1 2
3
6
4
7
8 9 10
13
11 1224
1615
14
17
201918
23
2221
Pin Description
1Vdc
2GND
3Vdc
4GND
5
6Trim +
7Trim -
8Trailer
9Common neutral relays contact
10NC contact neutral relay
Left engine
11Forward gear
12GND
13Reverse gear
14GND
15
16GND
17Reverse
18GND
19Common neutral relay contact
20NC contact neutral relay
Right engine
21Common trim contact
22Trim +
23Trim -
24Trailer
Trim common contact
Forward gear
22030624.13
vetus® Electronic engine remote control
Page 23
5.5 Actuator labels
Inside the actuator there are two labels indicating code and serial number. Please write them down in case you call for
assistance.
Actuator codeSerial number
Actuator Codes
1 mechanical engine and 1 gearbox mechanical (no trim)
1 mechanical engine and 1 gearbox mechanical (with trim)
EC3UMM1
EC3UMMT1
1 electronic engine (V) and 1 gearbox mechanical (no trim)EC312EM1
2 electronic engines (V) and 2 gearboxes mechanical (no trim)EC312EM2
1 electronic engine (V) and 1 gearbox mechanical (with trim)EC312EMT1
2 electronic engines (V) and 2 gearboxes mechanical (with trim)EC312EMT2
1 mechanical engine and 1 gearbox solenoid driven (no trim)EC4UME1
1 mechanical engine and 1 gearbox solenoid driven (with trim)EC4UMET1
2 mechanical engines and 2 gearbox solenoid driven (with trim)EC4UMET2
1 mechanical engine + electric gear + trollingEC4UMETR1
*) identifies the power supply voltage; (*) = 2 identifies actuators with only 24 Vdc; (*) = 3 identifies actuators which can
work with both 12 and 24 Vdc.
All actuators with electronic gearbox interface have the neutral relay option already implemented.
vetus® Electronic engine remote control
030624.1323
Page 24
6 Accessories and Options
Cables reported here below are used in standard installations. For specific engines there are anyhow available
cables with their proper connectors; in case you need
cables for specific engines, please contact the supplier.
For a correct mounting plug in the connector at 90°
with respect to wall side of the actuator box. Rotate
then the ring until the cable enters into the counterpart M12.
If the cable has been inserted correctly, it must be possible to screw completely by hand the cable without
too much efforts. The best electrical connection and the
max water protection of this connector is reached when
screwed with around six turns.
Connector for throttle cables
90°
Engine cables must be installed as far as possible from
heat generating sources. If the cable is running for
some of its length nearby the engine, protect this part
of the cable with a cover suitable to reflect the heat
generated by the engine.
Connector for CANbus data transmission cable
Wall connector
Polarization code B
Cable connector
Polarization code A
24030624.13
Wall connector
Cable connector
vetus® Electronic engine remote control
Page 25
6.1 CANBus cable
6.1.1 CANBus data transmission cable
LengthCodeLengthCode
L=3 mDTCAN3ML=10 mDTCAN10M
L=5 mDTCAN5ML=15 mDTCAN15M
L=7,5 mDTCAN7,5M
6.1.2 CANBus extension cable
L
L
LengthCode
L=30 mDTCAN30M
6.2 Cable for electronic engine
6.2.1 Cable for 1 electronic engine with 1 channel: voltage, PWM, 4-20 mA
Code B
Front view
L
LengthCode
Wire colourFunction
WhiteSignal
YellowGND
L=3 mEC3E3U
Important: this cable is without connector on engine side
vetus® Electronic engine remote control
030624.1325
Page 26
6.3 Cable actuator – gearbox solenoid driven
For the connection towards the gearbox solenoid driven, please refer to sections 8.2.1 and 8.2.3. of this manual.
Wire colourFunction
Black 1Forward
Black 2Reverse
Yellow-GreenSupply
Front view
L
LengthCode
L=3 mEC3T2
Important: this cable is without connector on engine side
For the connection towards the gearbox solenoid driven, please refer to sections 8.2.2. and 8.2.4. of this manual.
Wire colourFunction
Front view
Black 1Forward - Signal
Black 2Reverse - Signal
Black 3Neutral relay
Black 4Forward - GND
Black 5Neutral relay
Black 6Reverse - GND
L
LengthCode
L=3 mECG3/6
Important: this cable is without connector on gearbox side
26030624.13
vetus® Electronic engine remote control
Page 27
6.4 Cable actuator – trim/flap
For the connection to trim/flap, please refer to sections 8.2.7. and 8.2.8. of this manual.
Front view
L
LengthCode
L=3 mEC3T3M
Wire colour
Trim HarnessHarness Flap
Black 1Trim -Flap -
Black 2Trim +Flap +
Yellow-GreenTrailer(Vdc Flap)
Function
vetus® Electronic engine remote control
030624.1327
Page 28
6.5 Cable actuator – Mercruiser® trim pump
The cable for the trim pump of Mercruiser sterndrive has a length of 3 meters; in the cabling are included the fast-on
connections to the micro-switch for the end of stroke of the tilt.
Fast-on receptable
White
3 m (118 1/8”)
LengthCode
L=3 mEC3T3MM
Fast-on receptable
Blue
Yellow
Blue
5
0.6 m (23
/8”)0.15 m (5 7/8”)
Mercruiser® trim pump sideActuator side
C
B
VETUS cable code:
TrimYellow
Trailer
Blue
Actuator
Trim+
White
Faston F
Faston F
Mercruiser pump electric circuit
Supply (non used)
Red (not used)
TrimGreen
Connector
Connector
Trailer
Blue
Faston M
Faston M
Mercruiser pump
NC Trailer switch
Blue
Violet
28030624.13
vetus® Electronic engine remote control
Page 29
6.6 T-Splitter
33.5 (1 5/16”)28.4 (1 1/8”)
”)
8
/
5
40.5 (1
Code: CANT
6.7 Power supply connector
30 (1 3/16”)
”)
16
/
13
ø 21 (
43 (1 11/16”)37 (1 7/16”)
”)
16
/
1
ø 27 (1
Code: EC3SUP
Important: cabling instruction of power supply connector are at section 8.1.1. of this manual.
vetus® Electronic engine remote control
030624.1329
Page 30
7 Configuration of the CANBus network
System types, installation schemes and addressing for command stations and actuators
How to configure the installation depends from the quantity, type of engines and gearboxes and number of command
stations. Actuators and command stations, which communicate together through the CANBus network, must be configured in relation to how they are connected to the CANBus network. In the following installation schemes you find:
• Components necessary to build an installation
• Configuration of actuators and command stations in relation of their position on the CANBus network
The following installation schemes cover the most common application cases.
7.1 Installation with 2 mechanical actuators – solution A
Command station 1Command station 2Command station 3
Actuator for
left engine
JP14: OFF (address)
JP19: ON (end-line)JP19: OFF (end-line)
Actuator for
right engine
JP14: ON (address)
Data transmission cable
Code: DTCANxx
This installation scheme is valid for systems with:
• Up to 3 command stations and 2 engines with mechanical throttle, mechanical gearbox, with/without trim;
30030624.13
vetus® Electronic engine remote control
Page 31
7.2 Installation with 2 mechanical actuators – solution B
Command station 2Command station 3Command station 1
Actuator for
left engine
JP14: OFF (address)
JP19: OFF (end-line)
Data transmission cable
Code: DTCANxx
Actuator for
right engine
JP14: ON (address)
JP19: OFF (end-line)
This installation scheme is valid for systems with:
• Up to 3 command stations and 2 engines with mechanical throttle, mechanical gearbox, with/without trim;
vetus® Electronic engine remote control
030624.1331
Page 32
7.3 Installation with 2 mechanical actuators – solution C
Actuators are placed at the ends of the CANBus network
Command station 1Command station 2Command station 3
Actuator for
left engine
JP14: OFF (address)
JP19: ON (end-line)
Data transmission cable
Code: DTCANxx
Actuator for
right engine
JP14: ON (address)
JP19: ON (end-line)
This installation scheme, typical for catamaran applications, is valid for systems with:
• Up to 3 command stations and 2 engines with mechanical throttle, mechanical gearbox, with/without trim;
32030624.13
vetus® Electronic engine remote control
Page 33
7.4 Installation with 1 actuator – solution D
The actuator is placed at one end of the CANBus network.
Command station 2Command station 3Command station 1
Actuator
JP14: OFF (address)
JP19: ON (end-line)
Data transmission cable
Code: DTCANxx
This installation scheme is valid for systems with:
• up to 3 command stations and 1 engine with mechanical throttle, mechanical gearbox, with/without trim (or flap);
• up to 3 command stations and 1or 2 engines with electronic throttle (voltage or CANBus), mechanical gearbox, with/
without trim (or flap);
• up to 3 command stations and 1 or 2 engines with electronic throttle (voltage or CANBus), solenoid driven gearbox,
with/without trim (or flap);
vetus® Electronic engine remote control
030624.1333
Page 34
7.5 Installation with 1 actuator – solution E
The actuator is placed in the middle of the CANBus line.
Command station 1
Command station 2Command station 3
Actuator
JP14: OFF (address)
JP19: OFF (end-line)
Data transmission cable
Code: DTCANxx
This installation scheme is valid for systems with:
• up to 3 command stations and 1 engine with mechanical throttle, mechanical gearbox, with/without trim (or flap);
• up to 3 command stations and 1or 2 engines with electronic throttle (voltage or CANBus), mechanical gearbox, with/
without trim (or flap);
• up to 3 command stations and 1 or 2 engines with electronic throttle (voltage or CANBus), solenoid driven gearbox,
with/without trim (or flap);
34030624.13
vetus® Electronic engine remote control
Page 35
7.6 Configuration: end of line termination resistor and address setting of command stations
and actuators
According to the number and to the position on the CANBus communication net, command stations and actuators must
be configured to guarantee the correct functioning of the system. End of line termination resistors must be enabled on
the devices placed at the end of the CANBus network.Configuration of the command station
7.6.1 Configuration of the command station
It is mandatory to setup the command station in relation to its position on the CANBus net. Each command station must
have a different address number and if the command station is connected at the end of the CANBus net, the end line
dip-switch must be enable (ON).
Under the base of the command station there is a plastic cap.
Unscrewing it, you have access to the dip-switches.
Operation:
• unscrew the plastic cap;
• set the dip-switch according to one of the configurations de-
scribed in chapter 7
• screw again the cap.
DIP switch configuration
1234
Command station 1
Command station FSM
Command station 2
Command station 3
CodeS/N
Dip-switch 1: OFF end-line resistance disabledON end-line resistance enabled
Dip-switch 2: trolling option
Dip-switch 3 and 4: identify the command station
Trolling
Line termination
ON
OFF
Address
ON
OFF
The dip-switches configure the command station according to its position in the CANBus network. The selector of the dip
switch is represented in the nearby label with the black square.
Dip- switch 3Dip- switch 4
Command station 1OFFOFF
Command station Fast Start-up Mode (this is alternative to command station 1)ONOFF
Command station 2OFFON
Command station 3ONON
vetus® Electronic engine remote control
030624.1335
Page 36
Important 1: if there are more command stations connected to the same CANBus network, each command station
must have a unique address. The address of the command station is defined by the configuration of
thedip-switches.
Important 2: “command station 1” and “command station Fast Start-up Mode” cannot co-exist in the same system: ei-
ther you have a “Fast Start-up Mode” or “Command station 1”.
Important 3: to configure the dip-switches of each command station, refer to the installation schemes reported from
section 7.1. to section 7.5.
Important 4: command station is configured from the factory for systems with only one actuator that can control 2 mo-
tors. This is the typical application where there are two motors and two gearboxes with electronic, interface (like it is described in sections 7.4 and 7.5). In case of systems with two mechanical engines and two
mechanical gearboxes, you need to use two mechanical actuators (these are the installations described
at sections 7.1, 7.2 and 7.3). If this is the case, the command station must be re-configured as described at
section 4.4.
36030624.13
vetus® Electronic engine remote control
Page 37
7.6.2 Configuration of the actuator
To configure the actuator it is necessary to:
• enable or disable the end of line resistor
• define the CANBus address
These operations must be according to the position of the actuator as described in the schemes of chapter 7.
Actuator PCBoard version 3.1
JP14 defines the CAN Bus address of the actuator. Factory setting is JP14 = OFF (address =0).
JP19 enables (ON) or disables (OFF) the line termination. Factory setting is JP19 = ON (line termination = ON).
In some documentation, alternative to ON or OFF are indicated YES or NO.
If JP14 = ON, address = 1
If JP19 = ON, end of line is enabled
The actuator configuration changes according if the system is with one or two actuators:
Installations with 1 actuatorInstallations with 2 actuators
JP14 = OFF (address = 0)
The settings of JP14 and JP19 depend on the configuration of the CANBus network, as described from
section 7.1 to 7.5
Left actuator is with JP14 = OFF (address = 0)
Right actuator is with JP14 = ON (address = 1)
vetus® Electronic engine remote control
030624.1337
Page 38
7.7 Configuration with more than 3 command stations
In case are required more than 3 command stations, command station with address n° 3 must be with serial number
greater than 18500. It is then possible to add to the CANBus network an unlimited number of command stations, which
must have all the CANBus address n° 3.
Command stations with CANBus address = 3 can be physically placed anywhere in the CANBus network, but the CANBus
must have at its ends the end-of-line terminations (see sections from 7.1 to 7.6). Here below an example of a single actuator installation with more than 3 command stations.
Actuator
JP19: ON (end-line)
JP14: OFF (address)
Command station 3Command station 3
Command station 3
Command station 3Command station 2
Code: DTCANxx
Data transmission cable
38030624.13
Command station 1
vetus® Electronic engine remote control
Page 39
8 Electrical installation
System’s components involved: actuator, supply connector, all the electrical cables
8.1 Wiring from the battery to the actuator (input cables)
8.1.1 Supply connector
First of all you must wire the power supply cable, do not connect any other cable before having checked that this
operation has been performed correctly!
Choose a cable with a cross section of at least 2,5 mm2.
Each actuator is delivered with an external supply plug, identify the insert of the power plug.
GND - it is
marked with ‘N’
• pay attention that the positive wire must be screwed to the clamp with the red mark
• insert the plug into the connector of the actuator box and power-up
• open the actuator box removing the 4 plastic screws
If the plug has been wired properly, after power up, the display shows a sequence of 2 codes: ‘FI’ and ‘XX’:
• ‘FI’ means Firmware;
• ‘XX’ is the firmware version.
… and after 2 seconds the display shows “_ _”.
If the display on the actuator doesn’t show any light, it means that there is no power supply on the actuator box.
Causes:
Vdc (the plug is
marked with in red)
• the electrical connection is missing, check where
• the actuator has been supplied with inverse polarity, therefore:
• swap plus and minus wires, in order to re-establish the right polarity on the supply cable
• replace the fuse of 6,3 A that you find on the front of the actuator box
• insert again the plug into the connector of the actuator box and power-up
If the display is lighted, the cabling is correct and you see on the actuator’s display the following sequence of digits reported here above (FI XX _ _).
In case of installations with 2 actuators, repeat the same procedure on each actuator (check that both displays light on).
Only after you have assured that the actuators have been powered up correctly, you can connect the CANBus cable
between the actuators and all the other electrical cables.
Supply voltage 12 V24 V12/24 V
Internal fuse (on the actuator PCB)5,0 A
Wall fuse6,15 A-6,15 A
Current absorbed in no loaded condition0,5 A0,25 A0,5 A (max)
vetus® Electronic engine remote control
030624.1339
Page 40
8.1.2 The ignition key switch
Starter motors
The cables that connect the battery to the starter motors must have a cross-section of at least 50 mm2 (both the
“plus” and the “minus” cable). The “minus” cable of the actuator must be connected directly to the battery. It is vital
that there is zero voltage between battery negative terminals.
Electronic system with 1 actuator
In case of 2 batteries, the actuator must be connected
to both the batteries. The “plus” cables must be con-
Each actuator must be supplied from its own battery.
The minimum section of the cable must be of 2,5 mm2.
Electronic system with 2 actuators
nected with a 10A decoupling diode. In this way the
actuator will be supplied by the most charged battery.
The minimum section of the cable must be of 2,5 mm2.
Refer to electrical installation scheme reported in section 8.1.3 for system with one ignition key and 8.1.4 for
system with two ignition keys. This last scheme allows
to power the actuator box activating at least one of
the two ignition keys.
Refer to electrical installation scheme reported in section 8.1.6.
If your application has double deck (e.g. main deck
and fly-bridge) refer to installation scheme reported in
section 8.1.7.
If your application has double deck (e.g. main deck
and fly-bridge) refer to installation scheme reported in
section 8.1.5.
8.1.3 Electrical installation of systems with 1 engine, 1 actuator and 1 ignition key
Ignition key
- Battery
Signal 15
A1
D
R
A2
Actuator power supply connector
+
L
Battery
F
Com
NO
-
Ref.Description
12 V power
supply
24 V power
supply
DDiode10 A, 20 V5 A, 24 V
RRelay10 A, 12 V5 A, 24 V
FFuse10 A
Terminal 15 is the signal coming from the igni-
15
tion key lock. When the ignition key is on its rst
detent, signal 15 is active.
Supply cable
cross section
N
2,5 mm
2
1,5 mm
2
40030624.13
vetus® Electronic engine remote control
Page 41
8.1.4 Electrical installation of systems with 2 engines, 1 actuator and 2 ignition keys
Ignition key - Left engine
+
- Battery
Signal 15
Battery
-
-
Battery
+
F
A1
D
R
A2
Com
NO
DD
Actuator power supply connector
L
For the detailed list of components, please refer to the table at section 8.1.3.
N
Ignition key - Right engine
F
Com
A1
R
NO
A2
Signal 15
- Battery
D
8.1.5 Electrical installation systems with 1 engine, 1 actuator and 2 ignition keys
Ignition key - Deck
- Battery
Signal 15
Ignition key - Fly Bridge
+
- Battery
Signal 15
Battery
-
DD
F
A1
D
R
A2
Com
NO
L
Actuator power supply connector
For the detailed list of components, please refer to the table at section 8.1.3
vetus® Electronic engine remote control
N
030624.1341
Page 42
8.1.6 Electrical installation of systems with 2 engines, 2 actuators and 2 ignition keys
Ignition key - Left engine
+
- Battery
Signal 15
Battery
-
-
Battery
F
A1
D
R
A2
For the detailed list of components, please refer to the table at section 8.1.3.
Com
NO
L
N
Actuator power supply connector
Ignition key - Right engine
+
Signal 15
- Battery
F
Com
NO
L
A1
R
A2
N
D
42030624.13
vetus® Electronic engine remote control
Page 43
8.1.7 Electrical installation of systems with 2 engines, 2 actuators and 4 ignition keys
Ignition key - Deck
- Battery
DDDD
Ignition key - Fly Bridge
Signal 15
- Battery
Signal 15
+
-
-
Ignition key - Fly Bridge
+
BatteryBattery
F
A1
D
R
A2
Com
NO
L
N
Com
NO
L
Ignition key - Deck
Signal 15
Signal 15
- Battery
- Battery
F
A1
R
A2
N
D
Actuator power supply connector
For the detailed list of components, please refer to the table at section 8.1.3.
8.1.8 Dimensional criteria of the power supply cables
For the supply cables respect the following
provisions:
• Cables from the battery to engine starter
(both positive and negative poles) must
have a minimum cross section of 50 mm2, if
it is not specified a higher cross section by
the engine supplier.
• The GND of the actuator must be connected
directly to the negative pole of the battery.
Minimum cross section is 2,5 mm2.
• In case electronic throttle, it is very important to connect to a common GND point
(either GND bus bar or common bonding
conductor or hull) all the negative poles of
each electronic device.
Bow
thruster
Motor
starter
P
ECU
Flexball
actuator
vetus® Electronic engine remote control
030624.1343
Page 44
8.2 Wiring from the actuator to command stations, engines, gearboxes, trim/flaps, etc (output cables)
Almost every cable is provided with its unique connector, therefore it is easy to identify the cable type, its function and
where to mount it. Each connector has a different polarization, so it is almost impossible to mount a cable in the wrong
position. For the description of all the types of cables, look at chapter 6.
When mounting the electronic engine cable on the actuator: align the polarization keys and insert carefully the M12
connector of the cable on the actuator M12 counterpart. Rotate then the M12 ring until the cable enters completely into
the counterpart. If the cable has been inserted correctly, it must be possible to screw completely by hand the cable without too much efforts (around 6 full rotations). For more info look at chapter 6.
There are basically 4 types of actuators classified on the type of interface (mechanic or electronic) and on the type of
connector placed on the actuator itself (with or without neutral relay).
8.2.1 Actuator with mechanical interface without neutral relay
CANBus to the comman station
Left engine - Throttle
Left engine - Trim/Flap
ThrottleGear
Mech left engine
Ein left engine
Gear
Neutral switch
Trim
Flap
ThrottleThrottle
Canbus
+12 V
+24 V
Left engine - Throttle
Right engine - Trim/Flap
Trim
Flap
ThrottleGear
Mech left engine
Ein left engine
Gear
Neutral switch
Left gearbox
Right gearboxFuse Supply
For better comprehension are depicted only the electrical connections and not the mechanical linkages. This actuator is
available in versions with neutral relay, with or without trim and it is suitable for the following applications:
• mechanical engine and mechanical gearbox (only 1 propulsion group per actuator)
• mechanical engine and solenoid driven gearbox (2 propulsion groups per actuator)
• electronic engine and mechanical gearbox (2 propulsion groups per actuator)
44030624.13
vetus® Electronic engine remote control
Page 45
8.2.2 Actuator with mechanical interface and neutral relay
CANBus to the comman station
Left engine - Throttle
Left engine - Trim/Flap
ThrottleGear
Mech left engine
Ein left engine
Gear
Neutral switch
Trim
Flap
ThrottleThrottle
Canbus
+12 V
+24 V
Left engine - Throttle
Right engine - Trim/Flap
Trim
Flap
Mech left engine
Ein left engine
Gear
Neutral switch
ThrottleGear
Right gearbox with neutral relayLeft gearbox with neutral relayFuse Supply
For better comprehension are depicted only the electrical connections and not the mechanical linkages. This actuator is
available in versions with neutral relay, with or without trim and it is suitable for the following applications:
• mechanical engine and mechanical gearbox (only 1 propulsion group per actuator)
• mechanical engine and solenoid driven gearbox (2 propulsion groups per actuator)
• electronic engine and mechanical gearbox (2 propulsion groups per actuator)
vetus® Electronic engine remote control
030624.1345
Page 46
8.2.3 Actuator with full electronic interface
Left engine - Trim/Flap
Left engine - Gearbox
Left engine - Gearbox
Left engine - Trim/Flap
Gear
Neutral switch
Trim/Flap
Trolling
Left engine - Throttle
Trim/Flap
Trolling
Gear
Neutral switch
Left engine - Throttle
CANBus to the comman station
Throttle
Right engineLeft engine
Throttle
Canbus
+12 V
+24 V
Fuse
FuseSupply
Important: in case of single engine installation, use only the connectors for the right engine.
8.2.4 Actuator with full electronic interface and neutral relay
Left engine - Trim/Flap
Left engine - Gearbox
with neutral relay
Gear
Neutral switch
Trim/Flap
Trolling
Left engine - Throttle
Trim/Flap
Trolling
Gear
Neutral switch
CANBus to the comman station
Throttle
Right engineLeft engine
Throttle
Canbus
+12 V
+24 V
Fuse
Left engine - Gearbox
FuseSupply
with neutral relay
Left engine - Trim/Flap
Left engine - Throttle
Important: in case of single engine installation, use only the connectors for the right engine.
46030624.13
vetus® Electronic engine remote control
Page 47
8.2.5 Wiring scheme to gearbox in case of actuator without neutral relay
This wiring scheme refers to:
• Actuators without neutral relay (see sections 8.2.1 and 8.2.3)
• Gearbox cable code EC3T2 (see section 6.3), gearbox cable code 4665/36 (see section 6.3.1) and gearbox cable code
15/36 (see section 6.3.2)
Battery
Solenoid FWD
FunctionWire colour
+ BatteryYellow-green
Forward (FWD)Black 1
Reverse (REV)Black 2
Gearbox
Solenoid REV
Important: this scheme shows how to connect the electrical cables; battery switch and protection devices (e.g. fuses)
must be chosen according to local regulations.
8.2.6 Wiring scheme to gearbox in case of actuator with neutral relay
This wiring scheme refers to:
• Actuators with neutral relay (see sections 8.2.2 and 8.2.4)
• Gearbox cable code ECG3/6 (see section 6.3.1)
-
-
FunctionWire number
Forward (FWD) - Signal1
Reverse (REV) - Signal2
Neutral relay3
Forward (FWD) - GND4
Neutral relay5
Reverse (REV) - GND6
+
Solenoid FWD
Gearbox
Solenoid REV
+
Important: this scheme shows how to connect the electrical cables; battery switch and protection devices (e.g. fuses)
must be implemented according to local regulations.
vetus® Electronic engine remote control
030624.1347
Page 48
8.2.7 Wiring scheme from actuator to trim/flap with external supply
This wiring scheme refers to:
• Any actuator with serial number before 16500
• Trim/Flap cable code EC3T3M (see section 6.4)
FunctionWire colour
+ BatteryYellow-green
Trim - Flap -Black 1
Trim + Flap +Black 2
Battery
Solenoid DOWN
Trim/Flap pump
Solenoid UP
Important: this scheme shows how to connect the electrical cables; battery switch and protection devices (e.g. fuses)
must be implemented according to local regulations.
8.2.8 Wiring scheme from actuator to trim/flap with internal supply
This wiring scheme refers to:
• Any actuator with serial number equal or after 16500
• Trim/Flap cable code EC3T3M (see section 6.4)
Output signals are internally protected with 5A fuse.
Battery
Solenoid DOWN
48030624.13
FunctionWire colour
+ Battery-
Trim - Flap -Black 1
Trim + Flap +Black 2
Trim/Flap pump
Solenoid UP
vetus® Electronic engine remote control
Page 49
9 Programming of the actuator, general guidelines
9.1 Programming keypad
The keyboard has a display with two figures and three programming pushbuttons/keys.
Actuators are already programmed from the factory and it should not be necessary to make any change, but in case you
want to modify their programming, follow this procedure.
9.2 Display and Parameters
After power up, the display shows a sequence of 2 codes: ‘FI’ and ‘XX’:
• ‘FI’ means Firmware;
• ‘XX’ is the firmware version.
… and after 2 seconds the display shows “_ _”.
To enter into the parameter menu, press at the same time keys “UP” and “DOWN”. It is now possible to move from one
parameter to the other using the keys “UP” and “DOWN”.
For the setting of the specific parameters follow this procedure:
1. with the actuator turned on (the display shows “ _ _”) press both keys “UP” and “DOWN” and the first parameter will
appear on the display the message “A0”
2. pressing either “UP” or “DOWN” it is now possible to scroll the parameter’s list
3. pressing the key “ENTER”, the parameter’s value will be shown on the display. The display is now blinking and it is
possible to modify the parameter’s value, using the keys “UP” and “DOWN”
4. press the key “ENTER” to store the parameter’s value and immediately the display stops blinking
5. to set the other parameters, scroll the menu with the keys “UP” and “DOWN” and when you have pointed the param-
eter that you want to change, repeat this procedure from point 3.
vetus® Electronic engine remote control
030624.1349
Page 50
9.3 Actuator parameters
Parameters are different in relation of the type of actuator and application. The detailed parameter list for each application is described in the specific section reported in the following pages. Here below are listed the parameters common
for any type of actuator.
Code
display
A0Push-pull cable movement direction1 .. 4404
dI
dADelay on the throttle0 .. 9.9 s0.0 s00
CCTo be used for the check-up of the internal CANBus communication
A0 is described in section 11.2
With parameters dI and dA it is possible to set a delay time measured in tens of seconds:
• dI is the delay that occurs when you move the lever from forward (or reverse) to neutral. The actuator goes to neutral
only after the time set into dI expires.
• dA is the delay that occurs when you move the lever from neutral to forward (or reverse). The actuator starts to accelerate only after the time set into dA expires.
With parameter CC you can check if the communication between the command station and the actuator is correct. The
value of the parameter corresponds to a precise physical position of the lever and it is described in the following table:
Delay before disengaging the gearbox
DescriptionRangeFactory
value
0 .. 9.9 s0.0 s00
Value shown on dis-
play (factory value)
Note
Value shown on displayDescription
Nindicates that the command station is in neutral position
Findicates that the command station is in forward position
Rindicates that the command station is in rear position
1-2-3-4-…..-9-A
Looking at the display like in the picture here below, the left digit of the display shows the position of the left command
station and the right digit of the display shows the position of the right command station.
It is shown left lever position
according to the table above
indicates that the command station is in throttle condition: “1” is the position of
minimum gas and “A” is the position of maximum gas
It is shown right lever position
according to the table above
50030624.13
vetus® Electronic engine remote control
Page 51
10 Installation of the push-pull cable and stroke’s programming on
In this chapter will be presented the different types of push-pull cables and how to mount them.
10.1 Push-pull cables choice
It can be used 3 different types of push-pull cables. For the connection of the push-pull cable to the actuator, it is necessary to use its proper connection kit. The available kits are for Volvo® cable (E2, E3, C0, C3, C33…), Johnson® cable and
Mercruiser® stern drive cable.
10.1.1 Connection kit
Connection kit for Volvo® cable, or
cable type E2, E3, C0, C3, C33…
2x
2x
Each kit is enough to connect two push-pull cables.
Connection kit for Johnson® cableConnection kit for Mercruiser® cable
10.1.2 Standard push-pull cable
2x
2x
2x
vetus® Electronic engine remote control
030624.1351
Page 52
10.1.3 Mercruiser® stern drive push-pull cable
In case it is used the push-pull cable to connect directly the actuator to the Mercruiser® sterndrive, the plastic Mercruiser®
bracket is not necessary.
10.1.4 Johnson® push-pull cable
52030624.13
vetus® Electronic engine remote control
Page 53
10.2 Mounting of the push-pull cables between engine and actuator
This example is referring to the mounting of a standard push-pull cable. To mount the other types of cables, refer to the
drawings at sections 10.1.3. and 10.1.4. For the assembly, the throttle must be in minimum position and the actuator
must be turned off.
10.2.1 Connection of the push-pull cable to the engine
In this example it is assumed that if you pull the cable, the throttle speed increases.
1. Adjust the fixing of the push-pull cable in such a way that when the lever is at the minimum position (engine idle),
the rod of the cable is completely out (minimum engine speed).
2. Connect the push-pull cable to the engine throttle lever with the fork or the ball joint.
1.2.
10.2.2 Connection of the push-pull cable to the actuator
c
d
h
e
f
g
b
a
Elements to be used for the connection
a Screw + elastic washer to connect the eyelete Black aluminium cube
b Hole where to x the eyeletfPush-pull cable
cFixing screw (screw and washers)g Blade
d Bracket sloth Eyelet
vetus® Electronic engine remote control
030624.1353
Page 54
Follow the steps from 1 to 8 as reported here below:
1. Verify that the actuator’s throttle lever is at minimum position, as depicted in the picture here below (1). The lever
should be at 10 mm from the eyelet, otherwise enter into the jog programming mode and move the actuator’s lever to this position. For this operation follow steps from 1 to 7 section 11.1. The minimum speed throttle position is
parameter “UL”.
2. Verify that the position of the throttle lever is in idle position on the motor side as described at section 8.2.1.If this is
the case, at the actuator side the rod should be inside the push-pull cable (minimum stroke cable condition). Then
screw the eyelet (h) onto the cable’s rod (2).
5 (3/16”)
1.
2.
3. Align the eyelet on the push-pull cable (H1) with the hole of the plastic slider (H2). Insert the screw (+ elastic washer)
and fasten it.
3.
54030624.13
H1
H2a
vetus® Electronic engine remote control
Page 55
4. Insert the groove of the push-pull cable fitting between the blade (g) and the black aluminium cube (e).
4A
4B
5. Insert the push-pull cable into the slot of the bracket (d). Check that the fixing cube is centred with respect to the
slot on the bracket.
5A
6. Fix the black aluminium cube (e) against the bracket (d) using the fixing screw (c).
6A
6B
7. If the fixing position is not correct, tune the push-pull cable in such a way that when the cable is at its minimum, the
fixing screw is aligned with the notch on the slot.
8. Verify and eventually tune again minimum speed position (UL) and set maximum speed position (UH). For these
operations look at section 11.1
vetus® Electronic engine remote control
030624.1355
Page 56
10.3 Mounting of the push-pull cable between gearbox and actuator
This example is referring to the mounting of a standard Volvo Penta push-pull cable. To mount the other types of cables,
refer to the drawings at sections 10.1.3. and 10.1.4. For the assembly, the gearbox must be in neutral position and the
actuator must be turned off.
10.3.1 Connection of the push-pull cable to the gearbox side
Position the gearbox lever in neutral (the lever must be vertical).
1. Adjust the fixing of the push-pull cable in such a way that when the lever is in vertical position, the cable must be at
its half stroke
2. Connect the push-pull cable to the throttle lever using the fork.
1.2.
10.3.2 Connection of the push-pull cable to the actuator
d
h
e
f
g
c
a
b
Elements to be used for the connection
a Screw + elastic washer to connect the eyelete Black aluminium cube
b Hole where to x the eyeletfPush-pull cable
cFixing screw (screw and washers)g Blade
d Bracket sloth Eyelet
56030624.13
vetus® Electronic engine remote control
Page 57
Follow the steps from 1 to 8 as reported here below:
1. Verify that the actuator’s gear lever is in neutral position, as depicted in the picture here below (1). The lever should
be vertical, otherwise enter into the JOG MODE and move the actuator’s lever to central position. For this operation
follow steps from 1 to 7 of section 12.1. The neutral position is parameter “0F”.
2. Verify that the position of the gearbox lever is in neutral on the gearbox side as described previously. The push-pull
cable must be at its half stroke also on the actuator’s side. Then screw the eyelet (h) onto the cable’s rod (2).
1.
2.
3. Position the push-pull cable with the hole on the eyelet (H1) aligned with the hole of the plastic slider (H2). Insert the
screw (+ elastic washer) and fasten it.
3.
vetus® Electronic engine remote control
H1
H2a
030624.1357
Page 58
4. Connect the blade (g) and the black aluminium cube (e) onto the push-pull cable’s hub.
4A
4B
5. Then insert the push-pull cable into the bracket slot (d), picture 5. Verify that the fixing element is centred into the
bracket slot.
5A
6. Fix the black aluminium cube (e) against the bracket (d) using the fixing screw (c).
6A
6B
7. If the fixing position is not correct, tune the push-pull cable in such a way that when the gearbox’s lever is in neutral,
the push-pull cable is at its half stroke and the fixing screw is aligned with the notch.
8. Verify and eventually tune again the neutral position, set reverse (0L) and forward (0H) positions. For these operations look at section 12.1
58030624.13
vetus® Electronic engine remote control
Page 59
11 Programming of the strokes on actuator with mechanical inter-
In this chapter it will be presented how to program the actuator, in order to obtain the correct strokes for engine and
gearbox. The actuator looks according to the picture here below.
UL0L
0F
PushPull
0HUH
Throttle
You must program 5 positions and therefore 5 parameters: 2 for the throttle and 3 for the gearbox. Gearbox and throttle
positions have to be set according to the parameters of the here below table.
Parameters
to set
Throttle
Gearbox
Value on
display
ULMinimum speed position
UHMaximum speed position
0LGearbox Reverse
0FGearbox Neutral
0HGearbox Forward
Gearbox
Function
PushPull
Actuators are delivered from factory with:
• No throttle stroke,
• Forward, Reverse and Neutral positions coincident with the Neutral position
In order to start-up correctly the system you must do the correct setting the cable strokes.
vetus® Electronic engine remote control
030624.1359
Page 60
11.1 Programming of the push-pull cable strokes
1Switch-off the power supply, either from the mains or unplug and plug-in again the supply connector
Open the Actuator box and identify the programming keypad (3 push buttons) and the display (2 digits)
2
Press at the same time key “UP” and “DOWN” and, keeping pressed both keys “UP” and “DOWN”, turn on the
3
actuator’s voltage supply
On the 2-digit display shows up, with a steady light “UL”, which
4
corresponds to parameter Minimum Throttle. If you don’t need to modify
the minimum stroke, jump to step 8 of this procedure
5Press the “Enter” push button and the display will start flashing
When the display is flashing you have entered into the jog mode and
if you press either the “Up” or the “Down” push button, the left push-
6
pull cable will move according to the picture here beside. Press “Up” or
“Down” to adjust the position of Minimum Throttle
To store the position of Minimum Throttle, press “Enter” again. When the
7
display stops flashing it means that you have stored the position
Press the “Down” push button and the display will move to “UH”
8
(parameter
of Maximum Throttle)
Press the “Enter” push button and the display will start flashing. Press “Up”
9
until the cable reaches the position of Maximum Throttle
DOWNUHUP
UL
To store the position of Maximum Throttle, press “Enter” again. When the
10
display stops flashing it means that you have stored the position
Press the “Down” push button and the display will move to “0L”
11
(parameter of Gearbox Reverse)
60030624.13
vetus® Electronic engine remote control
Page 61
Press the “Enter” push button and the display will start to flash. Press “Up”
12
until the cable reaches the position of Gearbox Reverse
To store the position of Gearbox Reverse, press “Enter” again. When the
13
display stops flashing it means that you have stored the position
Press the “Down” push button and the display will move to “0F”
14
parameter of Gearbox Neutral)
Press the “Enter” push button and the display will start flashing. Press “Up”
15
until the cable reaches the position of Gearbox Neutral
To store the position of Gearbox Neutral, press “Enter” again. When the
16
display stops flashing it means that you have stored the position
Press the “Down” push button and the display will move to “0H”
17
parameter of Gearbox Forward)
Press the “Enter” push button and the display will start flashing. Press “Up”
18
until the cable reaches the position of Gearbox Forward
To store the position of Gearbox Forward, press “Enter” again. When the
19
display stops flashing it means that you have stored the position
Important:
• a not precise setting of the strokes may generate malfunctioning of the gearbox (delays in clutch-in and clutch-out) or
an excessive current absorption on the actuator.
• in case of stern drive and outboard engines, if the engine isn’t running, it isn’t possible to set the strokes, because the
clutch-in operation becomes very hard. In this is the case, actuate the rotation of the propeller manually, this will make
easier the clutch-in of the gearbox.
vetus® Electronic engine remote control
030624.1361
Page 62
11.2 Sea trials
Now your programming is finished!
In order to verify the settings you need to activate your electronic control system.
Switch-of the power supply and then switch on again.
If all the settings have been done correctly, the command station will look as follow:
Command station series 4500
To learn about how to command the boat go to chapter 3 (Pilot Instructions).
Engine
Warm/Sync
Engine
Command
You must test now the correct functioning of the gearbox and the throttle in relation to the command lever. After having
set the stroke positions, it might happen that there is not the right correspondence between the direction of the lever
and the movement executed by the actuator (e.g.: you move the lever forward and the gearbox cable is pushing instead
of pulling).
Changing the value of parameter A0 you can modify the correlation between the direction on the lever and the direction
on the actuator. The table here below defines the directions of throttle and gearbox in relation to the 4 possible values
of parameter A0, with the assumption to move the command station lever in forward direction (gearbox forward and
engine accelerated).
Value A0ThrottleGearbox
1
2
3
4
Factory setting A0 = 4
62030624.13
Push
(direction UL)
Push
(direction UL)
Pull
(direction UH)
Pull
(direction UH)
(direction 0H)
Push
(direction 0L)
Push
(direction 0L)
(direction 0H)
Pull
Pull
vetus® Electronic engine remote control
Page 63
The following examples show how to operate in case there is not the exact correspondence between the command lever
and the actuator.
System with mechanical throttle and mechanical gearbox
ProblemSolution
The gearbox push-pull cable positions
PushPull
UL0L
0F
are inverted (forward and backward positions are inverted) while the throttle
push-pull cable works correctly
The gearbox is working correctly while
the throttle push-pull cable positions
are inverted (min and max throttle positions are inverted)
PushPull
Set A0=3
Set A0=1
0HUH
Both gear or throttle push-pull cables
positions are inverted
Throttle
Gearbox
11.3 Specific parameters
Display
code
A0
dI
dADelay on the throttle0 .. 9.9 s0.0 s00
PPProportional coefficient0 .. 994040These para-
PIIntegral coefficient0 .. 99000
CCTo be used for the check-up of the internal CANBus communication
Push-pull cable movement direction
Delay before disengaging the
gearbox
DescriptionValues
1 .. 4404
0 .. 9.9 s0.0 s00
Factory
value
Value shown on dis-
play (factory value)
meters must not
be modified
Set A0=2
Note
vetus® Electronic engine remote control
030624.1363
Page 64
12 Programming of actuators for installations with electronic engine
In this chapter it will be presented how to program the actuator, in order to obtain the correct strokes of gearboxes. Depending if the boat is with 1 or 2 propulsion systems, the actuator looks according one of the pictures here below:
0L
0F
0H
Gearbox
PushPull
1L
1F
PushPull
Left gearboxRight gearbox
0L
0F
PushPull
0H1H
You must program either 3 or 6 positions and consequently 3 or 6 parameters: 3 for per each gearbox, according to the
parameters of the above table.
Parameter
Value on
display
Function
0LGearbox Reverse
Gearbox 1
(right)
0FGearbox Neutral
0HGearbox Forward
1LGearbox Reverse
Gearbox 2
(left)
1FGearbox Neutral
1HGearbox Forward
Actuators are delivered from factory with Forward, Reverse and Neutral positions coincident in the Neutral position.
Therefore the installer must do the correct setting the stroke, in order to start-up correctly the system.
64030624.13
vetus® Electronic engine remote control
Page 65
12.1 Programming of the gearbox strokes
1Switch-off the power supply, either from the mains or unplug and plug-in again the supply connector
Open the Actuator box and identify the programming keypad (3 push buttons) and the display (2 digits)
2
Press at the same time key “UP” and “DOWN” and, keeping pressed both keys “UP” and “DOWN”, turn on the
3
actuator’s voltage supply
On the 2-digit display shows up, with a steady light “0L”, which
4
corresponds to parameter (right) Gearbox Reverse
Press the “Enter” push button and the display will start flashing.
5
Press “Up” until the cable reaches the position of Gearbox Reverse
To store the position of Gearbox Reverse, press “Enter” again. When the
6
display stops flashing it means that you have stored the position
Press the “Down” push button and the display will move to “0F”
7
(parameter of Gearbox Neutral)
Press the “Enter” push button and the display will start flashing. Press
8
“Up” until the cable reaches the position of Gearbox Neutral
To store the position of Gearbox Neutral, press “Enter” again. When the
9
display stops flashing it means that you have stored the position
Press the “Down” push button and the display will move to “0H”
10
(parameter of Gearbox Forward)
Press the “Enter” push button and the display will start flashing.
11
Press “Up” until the cable reaches the position of Gearbox Forward
vetus® Electronic engine remote control
030624.1365
Page 66
To store the position of Gearbox Forward, press “Enter” again. When the
12
display stops flashing it means that you have stored the position
Press the “Down” push button and the display will move to “1L”
13
(parameter of left Gearbox Reverse)
Press the “Enter” push button and the display will start flashing.
14
Press “Up” until the cable reaches the position of Gearbox Reverse
To store the position of Gearbox Reverse, press “Enter” again. When
15
the display stops flashing it means that you have stored the position
Press the “Down” push button and the display will move to “1F”
16
(parameter of Gearbox Neutral)
Press the “Enter” push button and the display will start flashing. Press
17
“Up” until the cable reaches the position of Gearbox Neutral
To store the position of Gearbox Neutral, press “Enter” again. When the
18
display stops flashing it means that you have stored the position
Press the “Down” push button and the display will move to “1H”
19
(parameter of Gearbox Forward)
Press the “Enter” push button and the display will start flashing.
20
Press “Up” until the cable reaches the position of Gearbox Forward
To store the position of Gearbox Forward, press “Enter” again. When the
21
display stops flashing it means that you have stored the position
Important:
• a not precise setting of the strokes may generate malfunctioning of the gearbox (delays in clutch-in, clutch-out) or an
excessive current absorption on the actuator.
• in case of stern drive and outboard engines, if the engine isn’t running, it isn’t possible to set the strokes, because the
clutch-in operation becomes very hard. In this is the case, actuate the rotation of the propeller manually, this will make
easier the clutch-in of the gearbox.
66030624.13
vetus® Electronic engine remote control
Page 67
12.2 Sea trials
Now your programming is finished!
In order to verify the settings you need to activate your electronic control system.
Switch-of the power supply and then switch on again.
If all the settings have been done correctly, the command station will look as follow:
Command station series 4500
To learn about how to command the boat go to chapter 3 (Pilot Instructions).
Engine
Warm/Sync
Engine
Command
You must test now the correct functioning of the gearbox in relation to the command lever. After having set the stroke
positions, it might happen that there is not the right correspondence between the direction of the lever and the movement executed by the actuator (e.g.: you move the lever forward and the gearbox cable is pushing instead of pulling).
Changing the value of parameter A0 you can modify the correlation between the direction on the lever and the direction
on the actuator. The table here below defines the directions of throttle and gearbox in relation to the 4 possible values
of parameter A0, with the assumption to move the command station lever in forward direction (gearbox forward and
engine accelerated). With the assumption that you have done all the stroke setting with A0 = 4 (factory setting), modify
the correlation between lever and actuator as described in the schemes of the next page.
vetus® Electronic engine remote control
030624.1367
Page 68
System with one electronic motor and one gearbox mechanically driven
ProblemSolution
0L
0F
The gearbox push-pull cable positions
are inverted
PushPull
0H
Set A0=3
PushPull
Gearbox
System with two electronic motors and two gearboxes mechanically driven
ProblemSolution
1L0L
1F
0F
PushPull
0H1H
Positions of the right gearbox are
inverted while the positions of the left
gearbox are correct
Positions of the left gearbox are inverted while the positions of the right
gearbox are correct
Set A0=3
Set A0=2
68030624.13
Positions of both gearboxes are invert-
Right gearboxLeft gearbox
ed
vetus® Electronic engine remote control
Set A0=1
Page 69
12.3 Specific parameters
Display
code
A0Push-pull cable movement direction1 .. 4404
dIDelay before disengaging the gearbox0 .. 9,9 s0,0 s00
CCTo be used for the check-up of the internal CANBus communication
These parameters are present only in systems with electronic engine (ECU) and/or
electrical engine inverter driven. Parameters to define the voltage output interface will
be detailed at section 12.3.2.
DescriptionValues
Factory
value
Value shown on dis-
play (factory value)
Note
ters must not be
changed
12.3.1 Parameters to configure the voltage output signal for electronic engines
For installations with electronic engines or hybrid propulsion systems (engine driven by a frequency converter), it is necessary to set
the minimum and maximum voltage output. Voltage signal profile
is defined through parameters L*, and H*, where “*” means 1,2,3,4.
Important: the graphic on the right represents the voltage profile
defined by parameters L, H. Changes of factory values could cause
a system malfunctioning. Before making any changes, contact our
technicians.
V
L*
H*
Control lever stroke
vetus® Electronic engine remote control
030624.1369
Page 70
12.3.2 Parameters to configure the voltage output signals
Nanni
Diesiel
SteyrMercury
(Toyota)
Hyndai
Parameters
L1
H1433840424337484445424528
P1NANANANA10NANANANANANANA
L250 *0 *404344NANANANA
H22150 *50 *2150132422NANANANA
Motor DX
T4.270OthersIVS2 ChOthers
FNM Vetus
91013857886855
QSD 2.8
VM
John Deere
Cummins
FPT
Scania
L3
H3433840424337484445424528
P3NANANANA10NANANANANANANA
L450 *0 *404344NANANANA
H42150 *50 *2150132422NANANANA
* For Nanni Diesel / Toyota, L2, H2, L4, H4 must be programmed only if the diesel motor is combined with the electrical
motor. For further information see section 19.4, Programming of actuators with Hybrid engine option.
91013857886855
Motor SX
70030624.13
vetus® Electronic engine remote control
Page 71
13 Programming of actuators for mechanical engines and electronic
gearbox
13.1 Mounting of the engine the push-pull cable and programming of throttle mechanical
strokes
For the connection of the push-pull cables please refer
to chapter 10. To set strokes refer to chapter 11. In case
of actuators for 2 mechanical accelerators and 2 electronic gearboxes, the following parameters must be programmed.
UL
PL
Parameter
Left throttle
Right throttle
Value on
display
UL
UH
PL
PH
PushPull
UH
Left throttleRight throttle
PH
PushPull
13.2 Programming of the push-pull cable strokes
With this kind of actuator you must program 2 positions for each engine (minimum throttle and maximum throttle).
For the general programming instructions please refer to chapters 10 and 11.
13.3 Electrical cabling of the gearbox
For each gearbox are available 2 output relays. For proper wiring please refer to sections 5.4.2, 5.4.3, 8.2.5 and 8.2.6. of
this manual.
13.4 Specific parameters
Installations with electronic gearbox might require a delay time when you pass the lever directly from reverse to forward
or from forward to reverse. Factory setting is 0,5 seconds.
Display
code
dIDelay in switching off the gearbox0 .. 9,9 s0,0 s00
dADelay in start of throttle0 .. 9,9 s0,0 s00
Delay in neutral: it occurs any time you move
dF
vetus® Electronic engine remote control
directly from forward to reverse or from reverse
to forward. This delay does not occur when
from neutral you move to forward or reverse.
DescriptionValues
0 .. 9,9 s0,5 s05
Factory
value
Value shown on display
(factory value)
030624.1371
Page 72
14 Programming of actuators with electronic engine and electronic
gearbox
14.1 Electrical wiring
For electrical wiring please refer to chapter 8.
14.2 Specific parameters
Installations with electronic gearbox might require a delay time when you pass the lever directly from reverse to
forward or from forward to reverse. Factory setting is 0,5 seconds.
Display
code
dIDelay in switching off the gearbox0 .. 9,9 s0,0 s00
dADelay in start of throttle0 .. 9,9 s0,0 s00
Delay in neutral; it occurs any time you
move directly from forward to reverse or
dF
L1
H1
C1
L2
H2
C2
L3
H3
C3
L4
H4
C4
CCTo be used for the check-up of the internal CANBus communication
from reverse to forward. This delay does
not occur when from neutral you move
to forward or reverse.
These parameters are present only in system with electronic engine with ECU and/
or electric engine inverter driven. Parameters for the voltage outputs are described at
section 12.3.2.
DescriptionValues
0 .. 9,9 s0,5 s05
Factory
value
Value shown on dis-
play (factory value)
Note
72030624.13
vetus® Electronic engine remote control
Page 73
15 System configuration in case of options
15.1 Commissioning of actuators for installations with Trim or Flap command option
Trim or flap options don’t require any programming on the actuator.
Trim and flap cables are reported from section 6.4 to section to 6.5 included.
Sections 5.3.2 and 5.3.3 depict the pin-out of the electronic PCBs which perform the trim/flap commands. Electrical installation schemes are at sections 8.2.7 and 8.2.8.
15.2 Commissioning of actuators for installations with Trolling option
The command station must be configured by setting dip-switch 2 to ON (see section 4.5 of this manual). The actuator
is specific for this type of system. For its programming, refer to the document “Trolling_Flap option for lever EC3 & EC4”.
15.3 Commissioning of the actuators with Neutral Relay option
The mechanical actuator can provide a no contact signal when the gearbox is in neutral. This signal, if properly used in
the engine starter safety chain, allows the start of the propulsion engine only in case the gearbox is in neutral position.
The neutral signal is given through a two pole wire, as depicted here below. The neutral relay is normally open and it closes only in case the gearbox is in neutral and the actuator is properly supplied (if the actuator doesn’t receive the power
supply the relay is switched off and its contact is open).
The block diagram here below shows the safety chain:
FunctionWire number
Forward (FWD) - Signal1
Reverse (REV) - Signal2
Neutral relay3
Forward (FWD) - GND4
Neutral relay5
Reverse (REV) - GND6
Specific neutral cable is described at section 6.3
starter activation circuit
Engine ignition key
Electrical engine
R
+
-
Battery
+
-
Starter
vetus® Electronic engine remote control
030624.1373
Page 74
Black 1
Neutral relay
Black 2
Common
LengthCode
L=3 mEC3T2
To be noticed:
• the cable has 3 wires: black 1, black 2 and yellow/green. For this application do not use the yellow/green wire.
• maximum current which can be commutated by the neutral relay is 10 A.
• in case the actuator is not supplied, you cannot start the engine unless you provide a by-pass electrical circuit for
emergency situations.
• actuator with mechanical interface is just giving the information that itself is in neutral position. The neutral position
on the gearbox is to be considered valid only if the push-pull cable is mounted correctly.
Neutral relay option cables are depicted in sections 6.3.3 and 6.3.4. Installation schemes are at sections 8.2.5 and 8.2.6.
74030624.13
vetus® Electronic engine remote control
Page 75
16 Trouble shooting
16.1 What to do in case of system failure
Here below are described standard procedures to follow in case of faults. In case of vessel with 2 engines or of vessel
with two or more command stations, the redundancy of the system can overcome the situation of a first failure and the
electronic control system could continue to operate, but it is advisable to recover the boat and immediately find and
solve the problem.
16.1.1 Behaviour of the system in case of unforeseen shutdown
In case the engine switches off during navigation, the normal procedure requires to turn off the ignition key and then to
turn it on again. At power-up, independently on the position of the command station, the actuator behaves as follows:
• Gearbox is moved to a the safety position (neutral)
• Engine throttle is moved to minimum
The command station that had the control of the vessel, has now lost the command. To take the command
again, you must start again the following procedure:
• move the lever to neutral
• press “Command” and then “Warm-up”.
This procedure is described in section 3 of this manual.
16.1.2 Emergency lever and how to overcome faults during navigation in case of system with mechanical interface
In case of system’s fault due to:
• missing power supply
• data transmission cables broken
• broken push-pull cables
the electronic system can be switched off quickly
and the engines and gearboxes can be operated directly by the mechanical emergency levers.
If you have the connector panel in front of you,
the right emergency lever is for gearbox, the left
emergency lever is for engine.
Emergency levers are fitted on the control box.
During the normal functioning, the indexing
plunger device “A” is positioned as shown in the picture on the left. In emergency situation, to unlock the mechanism it is
enough to rotate of 180° the plunger “A” from its working position. After this operation, the mechanism (and the related
push-pull cable) can be operated manually using lever (B).
In order to engage again the system you must:
1. Rotate or assure that the mechanical indexing plunger device “A” is in lock position (like in the picture)
2. Move the emergency lever “B” towards the centre of stroke and move it back and forward until you hear a “click”.
3. Verify that after the “click” the lever is engaged (you cannot move it freely by hand). In case the emergency lever is
still free, repeat operations from point 1 to 3.
vetus® Electronic engine remote control
030624.1375
Page 76
16.1.3 Self-protection in case of overload or breakage of the push-pull cables
The 2 digit display on the actuator is a helpful instrument during trouble shooting. The actuator has a built-in control that
generates an alarm signal in case the push-pull cable becomes “too hard” or in case the cable’s stroke is not set correctly
(beyond the maximum stroke allowed by the actuator).
If one of the above mentioned cases occurs:
• the systems stops (no movements on the push-pull cables)
• on the display of the actuator appears an “E” or a “P” on the side of the overloaded cable
• all the LEDs of the command stations start to blink.
An “E” or “P” will be shown on
the side of the actuator with
the cable overload error or the
cable positioning error
“E” stands for overload failure.
“P” stands for position failure (missed position target).
In case one of the two alarms occurs, turn off the system and verify the causes that might have generated the alarm:
• errors in stroke setting, bending radius of the push-pull cables too small or push-pull cable “squeezes”
• performance of the push-pull cable too low or control cable degenerated over time: if push pull cables are not performing correctly, they must be replaced.
Restart the electronic control system only if you have removed the causes of the not correct functioning.
An “E” or “P” will be shown on
the side of the actuator with the
cable overload error or the cable
positioning error
76030624.13
vetus® Electronic engine remote control
Page 77
16.2 Analysis of the electronic system behaviour
It follows a list of behaviours, error messages and their possible remedies.
SymptomWhat to checkWhat to do
Power supply is missing, check
the causes:
Where to look
on the product
manual
After power up, there is no
light on command station or
on actuators
The 4 LEDS blink twice at
power on but then the
green LEDS are off and the
command station doesn’t take
the command
LEDs on command station are
never enlightened while the
display on the actuator is
enlightene
Without moving any lever
of the command station, the
actuator generates changes of
speed or unpredictable
engagement of the gear
Circuit breaker not correctly
connected
Electrical cables from the
battery to the actuator
The fuse on the actuator is
blown-up
Check that end of line
resistance terminations have
been correctly activated both
on actuators and on
command stations
CANBus data transmission
cable doesn’t transmit power
from actuator to command
station
2 command stations have the
same CAN address
Check and eventually
replace the circuit breaker
Check and fix supply cables
Verify that the power supply
connector of the actuator is
wired with the correct polarity.
Program dip-switches
according to your installation
scheme.
Check if the CANBus data
transmission cable is correctly
connected on the command
station (connector nut
requires 5.5 turns to be fully
seated). If power supply is still
missing, replace the CANBus
data transmission cable
Re-assign the CAN addresses
on the command station,
set correctly the dipswitches
positioned below the
command station
Chapters 5 and
8
Section 4.4.
and chapters 7
and 8
Chapter 6
Section 4.4.
and chapters 7
and 8
Only one lever commands
both the actuators, while the
second lever is not active
vetus® Electronic engine remote control
Command station is in
Synchro mode
The two actuators might have
the same CAN address and
receive the command from
the same lever
De-activate the Synchro
mode with the push-buttons
on the command station
Program dip-switch JP14
according to the following:
JP14 = OFF for the left
actuator
JP14 = ON for the right
actuator
Verify also that JP19 is
programmed according to
the installation scheme that
you have chosen (see from
section 7.1 to section 7.5)
Chapter 3
Section 4.4.
and chapters 7
and 8
030624.1377
Page 78
SymptomWhat to checkWhat to do
LEDs have faint light or the
reaction time to the command
is very slow
Where to look
on the product
manual
Check battery voltage
The motor doesn’t reach the
correct minimum or maximum
speed (installations with
mechanical actuators)
The setting of the strokes
has been done successfully
(chapter 13) but the actuator
doesn’t respond to the
commands during normal
operation
The engine doesn’t accelerate
but it is possible to engage
the gear (installations with
mechanical actuators)
With the control station lever
at minimum, the engine is
fully accelerated (installations
with mechanical actuators)
Check if the stroke of the
push-pull cable is correct,
both on the engine and on
the actuator
Verify that parameter PP = 40Set PP = 40
Check the stroke of the
gearbox. If you set a stroke
longer than necessary, the
gear can be engaged, the
actuator doesn’t manage to
reach the target position and
therefore it doesn’t activate
the throttle
There isn’t the right correlation
between the position of the
lever of the command station
and the movement generated
by the actuator
Tune the push-pull cable on
the engine and make a
precise setting of the stroke
on the actuator
Reprogram the gearbox
stroke
Modify the setting of
parameter A0
Chapter 10
Chapters 9
and section
11.3
Chapter 11
Schemes at
sections 11.2
and 12.2
Lever is in forward or reverse
position but the gear is not
engaged (installations with
pushpull cables)
The lever of the command
station is forward but it is
activated the reverse gear
instead of the forward gear
(installations with mechanical
actuators)
Check the stroke of the push
pull cable is correct, both on
the gearbox and on the
actuator
There isn’t the right
correlation between the
position of the lever of the
command station the
movement generated by the
actuator
Tune again the push-pull
cable both on the gearbox
and on the actuator
Modify parameter A0
Chapter 11
Sections 11.2
and 12.2
78030624.13
vetus® Electronic engine remote control
Page 79
16.3 Diagnosis through the command station
LEDs of the command station produce flashes to show operating conditions, warning and failure conditions.
LED indications
All LEDs are blinking with 1°
flash long and 2° flash long
All LEDs are blinking with
1° flash short and 2° flash long
All LEDs are blinking with
1° flash short and 2° flash short
The 2 green LEDs show a
steady light when the levers are
in neutral
The 2 green LEDs are switched
off, even if the levers are in
neutral
When it
happens
At power
up
Meaning/problemWhat to do
Command station configured for
installations with 1 engine
Command station configured for
installations with 2 engines and
1 actuator
Command station configured for
installations with 2 engines and
2 actuators
Gearboxes are in neutral and
the installation works correctly
Power supply is missing
If you need to reconfigure the
command station, see section
4.3
Check if the display on the
actuator is enlightened:
• if YES, verify the
connection of CANBus data
transmission cable;
• if NO, check the electrical
installation (chapter 8)
One of the green LEDs is
switched off, even if its
corresponding lever is in neutral
Green LED is blinking with duty
cycle: 90% On and 10% Off
The green LED is slowly blinking
(2 s period) with duty cycle: 50%
On and 50% Off
LEDs are blinking according to
the following combinations:
• Engine_left (green) + Wrm/
Sync(yellow)
• Cmd (red) + Engine_right
(green)
• All the 4 LEDs together
After
power up
The push-pull cable of the gearbox hasn’t come to the assigned
neutral position (actuators with
mechanical interface)
Command station is not
configured correctly with
respect to the type of
installation; command station
has been configured for
installations with 1 actuator and
it must be configured for
installations with 2 actuators
There might be a problem on
the position measuring device
of the command station
There is a failure on mechanical
actuators, probably due to:
• an extra load on push-pull
cables
• wrong setting of the
pushpull cable strokes
Check and remove the obstacle
which doesn’t permit the actuator to go to neutral position (see
chapters 10 and 11)
Reconfigure command station
as described at section 4.3
Contact VETUS
Go to the actuator’s display and
check which is the cable that has
generated the failure. On the
display is shown the message “E”
or “P” on the side where it has
occurred the failure (see section
16.1.3), then:
• replace the defective pushpull cable
• re-program the strokes of
the push-pull cables (see
chapters 10 and 11)
vetus® Electronic engine remote control
030624.1379
Page 80
17 Drilling mask for command stations
17.1 Command station series EC3
65 (2 9/16”)
”)
4
/
3
95 (3
22 (7/8”)
ø 25 (1”)
”)
2
/
1
12 (
”) 4 x
4
/
1
ø 6 (
80030624.13
vetus® Electronic engine remote control
Page 81
17.2 Command station series EC4
15
75 (2
/16”
68 (2 11/16”)
)
”)
16
/
9
14 (
”)
2
/
1
(4
”)
16
/
15
(2
134
ø 5,5 (3/16”) 4 x
114
Attention: drawings here depicted are not corresponding to the object’s real physical size
vetus® Electronic engine remote control
030624.1381
Page 82
18 Drilling mask for actuator
”)
16
/
13
(11
300
170 (6
11
/16”)
Attention: drawings here depicted are not corresponding to the object’s real physical size