Vessel Stat Clean F120S-E Instructions Manual

Instruction Manual
Quality does it
Thank you for purchasing our Stat Clean No. F120S-E.
Read this instruction manual before use. Keep it in a safe handy place for future reference.
For Your Safety·······························P.2
Product Features ····························P.3
Production Specifications ···············P.4
External View··································P.5
Performance ···································P.6
Installation·······································P.7
Before Use······································P.8
Operation········································P.9
Maintenance ···································P.12
Troubleshooting······························P.16
Storage ···········································P.17
Warranty ·········································P.18
2
For Your Safety
Safety Precautions
Carefully read these Safety Precautions before use. Observe the precautions indicated herein to
ensure safety.
Safety precautions in this instruction manual are categorized into two types by the degree of danger
associated with each of the followings. Based on danger analyses performed by Vessel, all
precautions in this instruction manual are of the CAUTION level.
If the equipment is used in a manner not specified by the manufacturer, the protection provided by
the equipment may be impaired.
This symbol indicates a WARNING or CAUTION.
This symbol indicates a prohibited action.
This symbol indicates a mandatory required action
CAUTIONS
PROHIBITED
Do not use the F120S-E in environments that require explosion-proofing. The F120S-E is not of explosion-proof construction, therefore explosion or fire may occur.
PROHIBITED
Do not use the F120S-E in flammable atmospheres. The corona discharge can act as an ignition source and cause an explosion or fire.
PROHIBITED
Do not use the F120S-E in environments subjected to sharp temperature fluctuations or dewing. This kind of environment can lead to breakdown.
.
DO NOT WET
Do not use the F120S-E in highly damp places or anywhere it may be wet by water, oil, solvent or other liquid. Contact with moisture can result in electric shock or breakdown.
PROHIBITED
Do not use the F120S-E for any other purpose than static erasing or dust removal.
PROHIBITED
Do not use the F120S-E with power supplies of ratings not specified in the specifications. Inappropriate power supplies can result in fire and electric shock.
PROHIBITED
Do not install, use or service the F120S-E until having understood the information in this instruction manual.
REMEMBER
Keep this instruction manual in a safe handy place for future reference.
CAUTION
VESSEL assumes no responsibility whatsoever for consequences arising from the use of this product.
WARNING
Indicates that improper handling can lead to serious injury or even death.
CAUTION
Indicates that improper handling can lead to minor injury and property damage.
3
Product Features
AC type corona discharge
• This is an AC corona discharge type ionizer. The ion balance is not disturbed by needle contamination.
• A high-frequency piezoelectric transformer is incorporated. Losses caused by recombination of ions are reduced, and ions are generated efficiently.
Fan type ionizer
• The light wind 120 mm square DC fan feeds ionized air softly.
• The fan’s airflow volume can be adjusted in three steps.
• The airflow direction can be changed vertically by adjusting the stand’s screw.
• Components are assembled into the compact body to create a small and lightweight product.
• The input power is 24 VDC. Power is supplied to the product from the enclosed dedicated AC adaptor.
Capacitive-coupled discharge
• The capacitive-coupled method applies a high voltage onto the discharge needle, thus providing outstanding ion balance stability.
Variable louver function
• The airflow direction angle on the front cover can be changed to straight or wide to set the static erasing range.
Safe design
• When the front cover is removed, the circuit is shut off and the power is turned OFF to prevent electric shocks.
• Fan -lock alarm function and high voltage output stop alarm function are available as a standard. The status is indicated with LED lamps.
• The alarm signals can be output externally to operate an external device such as lights.
• The high-frequency piezoelectric transformer has an output shutdown function which instantly lowers the output in the event of a short circuit or overload.
Maintenance
• The front cover can be opened and closed with a single touch. Easy access to the internal components simplifies maintenance.
• The “needle electrode”, which must be cleaned or replaced, is unit-type module which can be replaced easily without tools.
Environment measures
• RoHS compatible product
CE compliance product (EMC Directive)
• Various tests have been performed based on EN61000-6-4 and 6-2, and the basic requirements of CE have been satisfied.
Applications
Use to prevent trouble and dust adhesion caused by static electricity.
4
Product Specifications
Ionizer
Model : No.F120S-E
Ion generation method : High voltage AC corona discharge
Output voltage : AC10kV(p-p)
Input voltage : DC24V±5% 500mA(max)
Dimensions : H198×W162×D69.5mm (including stand)
Weight : 0.9 kg
Fan speed : 2.21m
3
/min(Max. fan speed)
Noise emission : 50.7dB (max. and straight airflow, without filter, characteristic A
measured at 1m) (actually measured value)
Ozone generation : 0.05ppm or less (Measured at 50mm)
Warning output : High voltage alarm (Red LED), stop due to fan lock(Red LED)
Protective function
: Fan motor rotation monitoring function (Detecting rotation lock)
: High-voltage output shut down function(overload detection)
: Front cover safety device (circuit cut off when open)
Working
temperature / humidity
: 5~40/ 35~65%RH(No dewing)
Storage
temperature / humidity
: 0~60/ 35~85%RH(No dewing)
Distance from
target area
: 150~900mm (Installation location: Non-hazardrous indoor location)
Static electricity
removal time
: Refer to the items in the capabilities chart.
Ion balance : Within ±10V (max. and straight airflow, without filter)
(at the time of shipment from the manufacture’s warehouse)
Material
: Casing ... Flame-retardant ABS, :Stand ... Stainless
: Front Cover... Flame-retardant ABS, :Electrode ... Stainless
Accessories
Adapter No.AD24-IT-EX
Rated input voltage :AC100V-240V(50/60Hz) 0.4A
Rated output voltage :DC24V 0.75A
Working
temperature /humidity
:0~40/10~85%RH(No dewing or freezing)
Cable length :DC output cable:approx.1.8 m , AC input cable:approx.1.8m
Weight :135g
Consumables
Electrode Needle Unit :F-120H
*The measurement values were obtained using the VESSEL measurement environment, so errors
could be induced depending on the operation environment.
5
External View
No.F120S-E
No.AD-24-IT-EX