Thank you for purchasing our Stat Clean No.CF300-E.
Table of Contents
■For Your Safety
■Product Features
■Product Specifications
■External View
■Performance
■Installation
■Before Use
■Names and Functions
■Operation
■Maintenance
■
.
P.18
P.19
············ P.20
P.21
P.22
P.22
P.23
P.25
P.26
P.28
······ P.31
For Your Safely
■
Safety Precautions
●Carefully read these Safety Precautions before use. Observe the precautions indicated herein to
ensure safety.
●Safety precautions in this instruction manual are categorized into two types by the degree of danger
associated with each of the followings. Based on danger analyses performed by VESSEL, all
precautions in this instruction manual are of the CAUTION level.
●If the equipment is used in a manner not specified by the manufacturer, the protection provided by
the equipment may be impaired.
WARNING
CAUTION
Indicates that improper handling can lead to serious injury or even death.
Indicates that improper handling can lead to minor injury and property damage.
This symbol indicates a WARNING or CAUTION.
This symbol indicates a prohibited action.
This symbol indicates a mandatory required action
WARNING
Do not use CF300-E in environments that require explosion-proofing.
PROHIBITED
CF300-E is not of explosion-proof construction, therefore explosion or fire
may occur.
PROHIBITED
PROHIBITED
DO NOT WET
PROHIBITED
PROHIBITED
PROHIBITED
REMEMBER
CAUTIONS
Do not use CF300-E in flammable atmospheres. The corona discharge
can act as an ignition source and cause an explosion or fire.
Do not use CF300-E in environments subjected to sharp temperature
fluctuations or dewing. This kind of environment can lead to breakdown.
Do not use CF300-E in highly damp places or anywhere it may be wet by
water, oil, solvent or other liquid. Contact with moisture can result in electric
shock or breakdown.
Do not use CF300-E for anything other than static erasure or dust removal.
Do not use CF300-E with power supplies of ratings not specified in the
specifications. Inappropriate power supplies can result in fire and electric
shock.
Handle CF300-E with care to avoid giving it an impact: e.g. by dropping it.
Keep this instruction manual in a safe handy place for future reference.
Product Features
■
Product Features
●AC-TYPE CORONA DISCHARGE
The small-sized 20KHz coil transformer is installed for efficient ion generation.
● CROSS-FLOW FAN INSTALLED
The cross flow fan that generates wide and uniform air blow and the front cover that is designed
considering the ion flow can help achieve excellent antistatic performance.
This is quieter than an axial fan type and creates a better working environment.
In addition, non-step airflow adjustment can be made, using the rotary control located on the front
side.
● SAFE DESIGN
A slide-type cleaning brush is installed on the front cover, which is used for maintenance of the needle
electrode at any time.
An easily-cleanable/-replaceable rough filter is installed on the bottom of the body.
● DESIGNED FOR SAFETY
The monitoring function for the abnormal stop of the fan motor and the stop caused by high voltage
output is equipped.
The high voltage transformer unit has the output shutdown function that reduces output instantly if
short circuit or overload occurs.
When an external notification device is connected to the alarm signal output terminal for fan lock (FAN
ALARM) or high voltage malfunction (HV ALARM), it notifies the user if a malfunction occurs.
● LOW VOLTAGE INPUT
Safe and low voltage input of 24V DC is used. An internal DC power supply of automatic machines,
etc. can be used.
● APPLICATIONS
For preventing troubles and dust adhesion caused by static electricity.
Product Specifications
■
Eraser
Model : No.CF300-E
Ion generation method : High voltage AC(20KHz) corona discharge
Input voltage : 24VDC±10%
Consumption current : 500 mA (max)
Dimensions : H157×W348×D165(including stand)mm
Weight : 2.9 ㎏
Fan speed : 2.5 ㎥/min(Max. fan speed)
Noise emission : 48 dB(A) Max. fan speed(Measured at 1m)
Ozone generation : 0.05ppm or less
Warning output : High voltage alarm (Red LED),
Fan lock alarm(LED Light blinks)
Protective function
Working ambient
temperature / humidity
Ambient storage
temperature / humidity
Distance from
target area
Static electricity
removal time
Ion balance : Within ±10V (At 300mm ,at the time of shipment)
Air filter :
Material
: Fan motor rotation monitoring function (Detecting rotation lock)
High-voltage output shut down function(overload detection)
Power fuse 3.15A
:5~40℃ / 35~65%RH (No dewing or freezing)
:0~60℃ 35~85%RH(No dewing or freezing)
:150~900mm (Installation location: Non-hazardous indoor location)
: Refer to the items in the performance chart.
Rough filter
:Casing and stand ... SPCC,
:Front cover ... ABS, :Electrode ... Inconel
Accessories
Adapter No.AD24-ITE
Rated input voltage :100-240V AC (50/60Hz) 0.4A
Rated output voltage :24V DC 0.75A
Working
temperature /humidity
Cable length :DC input cable:1.8 m , AC output cable:1.8m
*The measurement values were obtained under the VESSEL measurement environment, so error
could be induced depending on the operation environment.
:0~40℃ 10~85%RH(No dewing or freezing)