Vertiv VP9571A, VP7553, VP7541 User Manual

Page 1
Instruction
Manual
Basic Rack PDU
VP7541, VP9571A
and VP7553
VertivCo.com/geist
Page 2
Table of Contents
Specifications .............................................................................................................. 3
Overview .........................................................................................................................................................3
Environmental.................................................................................................................................................3
Temperature ...................................................................................................................................................3
Humidity..........................................................................................................................................................3
Elevation .........................................................................................................................................................3
Electrical..........................................................................................................................................................3
Receptacle Ratings .......................................................................................................................................... 3
EMC Verification ............................................................................................................................................. 3
Installation .................................................................................................................. 4
Instructions .....................................................................................................................................................4
Guidelines .......................................................................................................................................................4
Mounting .................................................................................................................... 5
Optional Local Monitoring ........................................................................................ 12
Power Meter .................................................................................................................................................12
Current Meter ...............................................................................................................................................12
Service/Tech Support................................................................................................ 13
Service and Maintenance..............................................................................................................................13
More Technical Support................................................................................................................................13
Page 3
BASIC RACK PDU
3
Specifications
Overview
The Vertiv Basic Rack PDU products are Power Distribution units (PDU) intended for connection to a 30 Amp AC Mains circuit. The PDUs are designed to be powered by a single phase AC input circuit. The Vertiv Basic Rack PDUs covered by this manual are available in vertical or horizontal configurations rated 208-240V and can be optionally configured with a Vertiv Power Meter that provides local monitoring and display of Current, Voltage, Wattage, and Power Factor.
Environmental Temperature
Operating:
10°C (50°F) min
45°C (113°F) max
Storage:
-25°C (-13°F) min
65°C (149°F) max
Humidity
Operating:
5% min 95% max
(non-condensing)
Storage:
5% min 95% max
(non-condensing)
Elevation
Operating:
0 m (0 ft) min
2000 m (6561 ft) max
Storage:
0 m (0 ft) min
15240 m (50000 ft) max
Electrical
See nameplate for unit ratings.
Receptacle Ratings
NEMA 5-15R or L5-15R
125 Volts, 12 Amp
NEMA 5-20R or L5-20R
125
Volts, 16
Amp
NEMA 6-20R or L6-20R
250
Volts,
16
Amp
IEC-320 C13
125/250 Volt,
12
Amp
(per
Receptacle
Bank)
IEC-320 C19
125/250 Volt, 16
Amp
EMC Verification
This Class A device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
Page 4
BASIC RACK PDU
4
Installation
Instructions
1. Using appropriate hardware, mount PDU to rack (see Mounting section for additional instructions.
2. Plug PDU into de-energized 30 Amp branch circuit receptacle.**
3. Connect devices into PDUs output receptacles. It is recommended that the devices are turned off until all devices are connected to PDU
4. Turn on branch circuit to energize PDU.
5. Power on devices. Sequential power up is recommended to avoid high inrush current.
**Branch Circuit should be sized based on the PDU’s nameplate electrical rating. A 24 Amp
rated PDU is intended for use on a 30 Amp Branch Circuit. For Global Units a 32 Amp rated PDU is intended for use on a 32 Amp Branch Circuit.
Guidelines
If the PDU is installed in a cabinet the ambient temperature of the rack should be no greater
than 45C.
Install the PDU such that the amount of airflow required for safe operation of equipment is not
compromised.
Mount the PDU so that a hazardous condition is not achieved due to uneven mechanical
loading.
Follow nameplate ratings when connecting equipment to the branch circuit. Take into
consideration the effect that overloading of the circuits might have on over-current protection
and supply wiring.
The PDU relies on the building installation for protection from over-current conditions. A
certified overcurrent protection device is required in the building installation. The overcurrent protection device should be sized according to the PDUs nameplate ratings and local/national
electrical codes.
Reliable earthing of rack-mount equipment should be maintained. Particular attention should
be given to supply connections other than direct connections to the branch circuit. The PDU
must be connected to an earthed socket-outlet.***
The PDU is intended for Restricted Access Locations only and only qualified service
personnel should install and access the PDU.
For pluggable equipment, install the PDU so that the input plug or appliance coupler may be
disconnected for service.
Sequential power-up of devices powered by the PDU is recommended to avoid high inrush
current.
Caution: Disconnect all power cords before servicing.
The PDU is intended for use with TN, TT, or IT power supply systems
***XP Series PDUs may optionally be configured as Isolated Ground units. All Isolated
Ground units will be shipped with an enclosure grounding cable. This cable must be connected between the enclosure and a reliable safety ground.
Page 5
BASIC RACK PDU
5
Mounting
Full Length Bracket
Using the full length bracket, mount PDU to rack as shown
Mini "L" Brackets (SLB-4)
Page 6
BASIC RACK PDU
6
Using the mini “L” brackets, attach PDU to rack as shown
Vertical Extension Brackets (VCB-1)
Using the vertical extension brackets, attach PDU to rack as shown
Toolless Mounting Hardware (11621)
Secure toolless mounting buttons to PDU as shown. Use toolless buttons with key-holed slots built into cabinet or with optional Vertiv key-holed brackets.
Page 7
BASIC RACK PDU
7
Toolless Full Length Bracket (TLFL)
Using full length toolless bracket and toolless mounting buttons, attach PDU to rack as shown
Single Side Mount 2 Unit Brackets (TSMX2)
Using single side mount 2 unit brackets and toolless mounting buttons, attach PDU to rack as shown
Page 8
BASIC RACK PDU
8
Offset/Side Mount Brackets (EZB-1)
Using the offset/side mount brackets, attach PDU to rack as shown.
7" Extension Brackets (XB-7)
Using the 7” extension brackets, attach PDU to rack as shown
Page 9
BASIC RACK PDU
9
Flush Mount Brackets (FM)
Using flush mount brackets, attach PDU to rack as shown
Adjustable Mount Brackets (AM)
Using adjustable mount brackets, attach PDU to rack as shown
Page 10
BASIC RACK PDU
10
Panel Mount Brackets (PM)
Using panel mount brackets, attach PDU to rack as shown
23" Conversion Mounting Brackets (23-RM)
Using conversion mounting brackets, attach 19” PDU to 23 rack as shown
Page 11
BASIC RACK PDU
11
Cable Mount Bracket (CMB-1)
Attach cable mount bracket to PDU as shown; use tie-wraps to secure cords to bracket
19" Horizontal/Panel Mount Brackets (7938)
Using the 19 horizontal/panel mount brackets, attach PDU to rack as shown
Page 12
BASIC RACK PDU
12
Optional Local Monitoring
Power Meter
The Vertiv PM-1 power meter is a low-power, high accuracy meter capable of measuring true RMS Current, Voltage, Power, and Power Factor. These values are individually shown on an easy to read, 4-digit LED Display, which continuously scrolls through the four different measured values. Each one of these displayed parameters is defined below. The Power Meter will automatically begin cycling through the displayed values when the PDU is connected to AC Mains power.
Current: PDU output current draw measured in true RMS Amps
Voltage: PDU output voltage measured in true RMS Voltage
Power: PDU output power measured in Watts – referred to as real or active
power
Power Factor: Ratio of real PDU output power to apparent PDU output
power****
Power Meter
Display
****Real power is the power in a circuit that is transformed from electric to non-electric
energy, while apparent power is the total power supplied to the circuit.
Current Meter
The Vertiv CM-1 current meter is a low-power, high accuracy meter capable of measuring true RMS Current. The value of current is continuously shown on an easy to read, 4-digit LED Display. The Current Meter will automatically begin to display value of output current when the PDU is connected to AC Mains power.
Current Meter
Display
Page 13
BASIC RACK PDU
13
Service/Tech Support
Service and Maintenance
No service or maintenance is required. Do not attempt to open the PDU or you may void the warranty. No serviceable parts inside. It is recommended that power be removed from the unit before installing or removing any equipment.
More Technical Support
VertivCo.com/geist Phone Support
1 800 432 3219
Email: support@VertivCo.com or contact your distributor Technical Support Form: vertivco.com/Tech-Support