Vertiv MPX PRC Quick Installation Manual

Page 1
SL-20839_REV1
590-1625-501A
1
MPX™ PRC
Quick Installation Guide
Before assembling and installing a Liebert® MPX™, read and understand all warnings and cautions in the Liebert® MPX™ User Manual - Global Applications which can be downloaded at www. VertivCo.com.
Vertiv strongly recommends that the MPX power entry module (PEM) be installed by an individual who is properly trained and qualified to perform electrical work.
WARNING: The Liebert MPX contains high voltage that can cause serious personal injury or death. The unit must be installed in a restricted-access location.
NOTE: If you need support for your MPX power rail chassis (PRC), contact a Vertiv representative. The MPX PRC contains no user-serviceable parts. Never work alone. De-energize the input power and discon-
nect power connections to all equipment in the rack before installing a Liebert MPX or connecting input power to the unit.
ASSEMBLY
Tools Required
• Phillips® (Tip Size 2) screwdriver
• 5 mm Allen wrench
To assemble and install the MPX PRC:
1. Attaching an MPX PRC to the cabinet
For 78.84 in (2000 mm) racks, attach two mounting brackets to the side horizontal sections A1 for each MPX PRC using an Allen wrench. For
86.61 in (2200 mm) racks, attach two mounting brackets to a vertical section A2.
NOTE: L-shaped brackets are used exclusively with Knurr® Miracel™ racks. L- or Z-shaped brackets can be used for racks from other manufacturers.
2. Placing the mounting buttons
Insert spring nuts into the rear of the MPX PRC. Tighten the screws through the mounting buttons and into the spring nuts using a Phillips® (
Tip Size 2
) screwdriver.
Z-shaped bracket L-shaped bracket
MPX PRC Bracket Vertical Install (L-shaped Bracket Shown)
Typical rack upright
1
2
Page 2
VertivCo.com | Vertiv Headquarters, 1050 Dearborn Drive, Columbus, OH, 43085, USA
© 2016 Verti v Co. All rights res erved. Vertiv an d the Vertiv logo are tra demarks or regis tered trademar ks of Vertiv Co. All othe r names and logo s referred to are trad e names, tradem arks or registe red trademarks of t heir respecti ve owners. While e very precauti on has been taken to en sure accuracy an d completenes s herein, Vertiv C o. assumes no re sponsibilit y, and discl aims all liabilit y, for damages resu lting from use of thi s information or for a ny errors or omiss ions. Specif ications are su bject to change wi thout notice.
2
MPX™ PRC
Quick Installation Guide
SL-20839_REV1 590-1625-501A
3. Securing the MPX™ PRC
Insert mounting buttons through the bracket cutout and slide it down into the slot to secure it.
4. Connecting the grounding cable (optional)
WARNING: Do not connect input
power to the MPX PEM until the Liebert MPX is fully assembled and mounted in place. As soon as input power is connected to the MPX PEM, the contacts on the underside are live with hazardous voltage and the MPX PRC carries live hazardous voltage.
Insert a spring nut into the rack frame near the grounding point. Attach a ground wire to the rack with a screw, washer and lock washer, securing the screw to the rack’s frame with the spring nut. Use a second field­supplied screw, washer and lock washer to secure the ground wire to the MPX PRC at the connection point marked with an earth-ground symbol.
NOTE: For instructions on how to install an MPX PEM and an MPX branch receptacle module (BRM) onto the MPX PRC, see the MPX™ PEM Quick Installation Guide and the MPX BRM™ Quick Installation Guide. For product details, see the
Liebert® MPX™ User Manual -
Global Applications
which can be
downloaded at www.VertivCo.com.
4
Typical rack upright
3