Vertex Standard VX-600, VX-600U Operating Manual

Page 1
VX-600
U
Operating Manual
VERTEX STANDARD CO., LTD.
4-8-8 Nakameguro, Meguro-Ku, Tokyo 153-8644, Japan
VERTEX STANDARD
US Headquarters
17210 Edwards Rd., Cerritos, CA 90703, U.S.A.
8350 N.W. 52nd Terrace, Suite 201, Miami, FL 33166, U.S.A.
YAESU EUROPE B.V.
P.O. Box 75525, 1118 ZN Schiphol, The Netherlands
YAESU UK LTD.
Unit 12, Sun Valley Business Park, Winnall Close Winchester, Hampshire, SO23 0LB, U.K.
YAESU GERMANY GmbH
Am Kronberger Hang 2, D-65824 Schwalbach, Germany
VERTEX STANDARD HK LTD.
Unit 5, 20/F., Seaview Centre, 139-141 Hoi Bun Road, Kwun Tong, Kowloon, Hong Kong
Page 2
Contents
Warning! FCC RF Exposure Compliance.................................................................................................... 1
Controls & Connectors................................................................................................................................... 2
Before You Begin ............................................................................................................................................ 3
Battery Pack Installation and Removal........................................................................................................ 3
Low Battery Indication ................................................................................................................................ 3
Operation......................................................................................................................................................... 4
Preliminary Steps......................................................................................................................................... 4
Operation Quick Start.................................................................................................................................. 4
Advanced Operation....................................................................................................................................... 7
Soft key and TOGGLE switch Functions .................................................................................................... 7
ARTS (Auto Range Transpond System).................................................................................................... 13
DTMF Paging System ............................................................................................................................... 13
Understanding Radio Waves ....................................................................................................................... 14
Accessories & Options .................................................................................................................................. 15
Congratulations!
You now have at your fingertips a valuable communications tool-a VERTEX STANDARD two-way radio! Rugged, reliable and easy to use, your VERTEX STANDARD radio will keep you in constant touch with your colleagues for years to come, with negligible maintenance down-time.
Please take a few minutes to read this manual carefully. The information presented here will allow you to derive maximum performance from your radio, in case questions arise later on.
We're glad you joined the VERTEX STANDARD team. Call on us anytime, because communications is our business. Let us help you get your message across.
Notice!: There are no owner-serviceable parts inside the transceiver. All service jobs must be referred to an authorized VERTEX STANDARD Service Representative. Consult your Authorized VERTEX STAN-
DARD Dealer for installation of optional accessories.
Page 3
WARNING! FCC RF EXPOSURE COMPLIANCE
FCC RF Exposure Compliance Requirements for Occupational Use Only:
This Radio has been tested and complies with the Federal Communications Commission (FCC) RF exposure limits for Occupational Use/Controlled exposure environment. In addition, it complies with the following Stan­dards and Guidelines:
FCC 96-326, Guidelines for Evaluating the Environmental Effects of Radio-Frequency Radiation.
r
FCC OET Bulletin 65 Edition 97-01 (1997) Supplement C, Evaluating Compliance with FCC Guidelines
r
for Human Exposure to Radio Frequency Electromagnetic Fields. ANSI/IEEE C95.1-1992, IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Fre-
r
quency Electromagnetic Fields, 3 kHz to 300 GHz. ANSI/IEEE C95.3-1992, IEEE Recommended Practice for the Measurement of Potentially Hazardous Elec-
r
tromagnetic Fields - RF and Microwave.
This radio is NOT approved for use by the general population in an uncontrolled exposure environ-
¦
ment. This radio is restricted to occupational use, work related operations only where the radio op­erator must have the knowledge to control his or her RF exposure conditions. The radio is transmitting when the red LED on the top of the radio is illuminated. You can cause the
¦
radio to transmit by pressing the P-T-T button. When transmitting, hold the radio in a vertical position with its microphone 2 inches (5 cm) away
¦
from your mouth and keep the antenna at least 2 inches (5 cm) away from your head and body. Always use Vertex Standard authorized accessories.
¦
VX-600U OPERATING MANUAL
1
Page 4
TOP SEL (Selector) Key
SIDE SEL
(Selector) Key
PTT (
Push To Talk
Switch
MONITOR Button
LAMP Button
CH (Channel) Selector
Antenna Jack
)
CONTROLS & CONNECTORS
Speaker
LED Indicator
Steady Green: Signaling off Blinking Green: Busy Channel (or Squelch off) Steady Red: Transmission in Progress Blinking Red: Battery voltage is low Blinking Yellow: Receiving a Selective Call
VOL/PWR (Volume/Power) Knob TOGGLE Switch
MIC/SP Jack
(
External Microphone/
)
Speaker
Sub Microphone
(
Noise Canceling Microphone
)
16-Button DTMF Keypad
(
16-key version only
)
Battery Pack Latch
2
Main Microphone
VX-600U OPERATING MANUAL
Page 5
BEFORE YOU BEGIN
Battery Pack Installation and Removal
To install the battery, hold the transceiver with
r
your left hand, so your palm is over the speaker and your thumb is on the top of the belt clip. Care­fully mate the battery’s four insertion slots with their corresponding alignment tabs on the trans­ceiver case, while tilting the Belt Clip outward. Proper alignment occurs with the battery pack offset about 1/2 inch from the top edge of the battery compartment. Guide the pack on to the tabs with a slight inward
r
pressure, then slide the battery pack upward, un­til it locks in place with a “Click.”
Tilt the Belt Clip
Insert the Battery Pack
To remove the battery, turn the radio off and re-
r
move any protective case. Slide the Battery Pack Latch on the bottom of the radio toward
the front panel while sliding the battery down about 1/2 inch. Then lift the battery out from the radio while unfolding the Belt Clip.
Do not attempt to open any of the recharge­able Lithium-Ion packs, as they could ex­plode if accidentally short-circuited.
Low Battery Indication
As the battery discharges during use, the voltage gradually becomes lower. When the battery voltage reaches 6.0 volts, it is time to substitute a freshly charged battery and recharge the depleted pack. The LED indicator on the top of the radio will blink red when the battery voltage is low (6 Volts or lower).
Caution
Danger of explosion if battery is replaced with an incorrect battery. Replace only with the same or equivalent type.
VX-600U OPERATING MANUAL
3
Page 6
Preliminary Steps
Install a charged battery
r
pack onto the transceiver, as described previously.
Screw the supplied an-
r
tenna onto the Antenna jack. Never attempt to operate this transceiver without an antenna con­nected.
If you have a Speaker/
r
Microphone, we recommend that it not be con­nected until you are familiar with the basic op­eration of the VX-600.
OPERATION
Quick Start
r
r
Turn the top panel’s VOL/PWR knob clockwise to turn on the radio on.
Turn the top panel’s CH selector knob to choose the desired op­erating channel. If you want to select an oper­ating channel from a different Memory Channel Group, press the Soft key (assigned to the Memory Group Up or Down function) to se­lect the Memory Channel Group you want before selecting the operating channel.
Note: Some models are programmed so that the operating channels are selected by the Soft key and the memory channel group is selected by the
CH selector knob. For further details, contact your VERTEX STANDARD dealer.
4
VX-600U OPERATING MANUAL
Page 7
Rotate the VOL/PWR
r
knob to set the volume level. If no signal is present, press and hold in the MONITOR but­ton (under the PTT switch) more than 2 seconds; background noise will now be heard, and you may use this to set the VOL/PWR knob for the desired audio level. Press and hold in the MONITOR button more than 2 seconds (or press the MONITOR button twice) to quiet the noise and resume normal (quiet) monitoring.
To transmit, press and
r
hold in the PTT switch. Speak into the microphone area of the front panel grille (above the [D] key) in a normal voice level. To return to the Receive mode, release the PTT switch.
VX-600U OPERATING MANUAL
OPERATION
r
r
Press the Soft key (if assigned to the Scan func­tion) or switch the TOGGLE Switch to the as­signed “Scan” position (when so programmed by your dealer) to start the scanner. The scanner rap­idly steps through each of the dealer-programmed channels, looking for incoming calls.
Press the TOP SEL key (on the top panel) or SIDE SEL key (the top button on the left side) to activate one of the preprogrammed functions which may have been enabled at the time of program­ming by the dealer. Similarly, when using the 16-key version, the [A], [B], [C] function keys may ac­tivate one of these features, if programmed by the dealer. See the next section for details regard­ing the available features.
, and [D
]
5
Page 8
OPERATION
r Switch the top panel’s
TOGGLE switch to the [A], [B], or [Cen­ter] position to activate one of the pre-pro­grammed functions which may have been enabled at the time of programming by the dealer. When this switch is in the [A (left)], [B (right)], or [Center] position, the feature programmed (by your dealer) to that switch position will be acti­vated. See the next section for details regarding the available features.
r Press the DTMF keys on the telephone keypad
while pressing the PTT switch to send DTMF tones (16-key version only).
r If a Speaker/Microphone is available, remove the
plastic cap and its two mounting screws from the right side of the transceiver, then align the con­nector of the Speaker/Microphone on the trans­ceiver body; secure the connector pin using the screws supplied with the Speaker/Microphone. Hold the speaker grille up next to your ear while receiving. To transmit, press the PTT switch on the Speaker/Microphone, just as you would on the main transceiver’s body, and speak into the microphone on a normal voice level.
Note: Save the original plastic cap and its mounting screws. They should be reinstalled when not using the Speaker/Microphone.
6
VX-600U OPERATING MANUAL
Page 9
ADVANCED OPERATION
Soft Key and TOGGLE Switch Functions
The VX-600 includes the [TOP SEL], [SIDE SEL], [
MONITOR], and [LAMP] keys, and the TOGGLE
switch, while the 16-key version additionally pro­vides [A], [B], [C], [D] function keys. The Soft key and TOGGLE switch functions can be customized, via programming by your VERTEX STANDARD dealer, to meet your communications/network re­quirements. Some features may require the purchase and installation of optional internal accessories. The possible Soft key and TOGGLE switch program­ming features are illustrated at the right, and their functions are explained on page 9. For further de­tails, contact your VERTEX STANDARD dealer.
For future reference, check the box next to each func­tion that has been assigned to the Soft key and TOGGLE switch on your particular radio, and keep it handy.
Functions
None Channel Scan Dual Watch High/Low Power Talk Around TX Save Disable Encryption Disable Lock Follow-Me Scan Group Recall Shortcut
:
Requires FVP-25 DTMF/Encryption Unit
ø
ø
TOGGLE switch (Position
A B
center
£ Group 1 £ Group 2 £ Group 3
£ Group 1 £ Group 2 £ Group 3
£ Group 1 £ Group 2 £ Group 3
)
VX-600U OPERATING MANUAL
7
Page 10
ADVANCED OPERATION
Functions
None Channel Scan Dual Watch High/Low Power Talk Around TX Save Disable Encryption Disable Follow-Me DW Call/Reset Speed Dial Emergency Group Up Group Down Channel Up Channel Down Monitor Lamp
ø
ø
TOP SEL
Soft key
SIDE SEL MONITOR LAMP
[A] [B] [C] [D]
:
Requires FVP-25 DTMF/Encryption Unit
ø
8
VX-600U OPERATING MANUAL
Page 11
ADVANCED OPERATION
Description of Operating Functions
Channel Scan
The Scanning feature is used to monitor multiple channels programmed into the transceiver. While scanning, the transceiver will check each chan­nel for the presence of a signal, and will stop on a channel if a signal is present.
One key or switch may be assigned to the Scan function, as follows:
One of the Soft keys may be assigned for
r
Scan operation; or The TOGGLE switch may have one position
r
assigned to the Scan function.
To activate scanning:
Press the assigned Soft key, or set the
¦
TOGGLE switch to the assigned position. The scanner will search the channels, looking
¦
for active ones; it will pause each time it finds a channel on which someone is speaking.
To stop scanning:
Press the assigned Soft key, or set the
¦
TOGGLE switch to a different position. Operation will revert to the channel to which
¦
the CH knob is set.
Note: Your dealer may have programmed your radio to stay on one of the following channels if you press the PTT switch during scanning pause:
Current channel (“Talk Back”)
£
“Last Busy” channel
£
“Priority” channel
£
“Home” channel
£
“Scan Start” channel
£
Dual Watch
The Dual Watch feature is similar to the Scan fea­ture, except that only two channels are monitored:
r The current operating channel; and r The “Priority” channel.
To activate Dual Watch:
Press the assigned Soft key, or set the
¦
TOGGLE switch to the assigned position.
The scanner will search the two channels; it
¦
will pause each time it finds a channel on which someone is speaking.
To stop Dual Watch:
Press the assigned Soft key, or set the
¦
TOGGLE switch to a different position.
Operation will revert to the channel to which
¦
the CH knob is set.
VX-600U OPERATING MANUAL
9
Page 12
Low Power
Talk Around
10
ADVANCED OPERATION
Press the assigned Soft key or switch the TOGGLE switch to the assigned position to set
the radio’s transmitter to the “Low Power” mode, thus extending battery life. Press the assigned Soft key again or switch the TOGGLE switch to the other position to return to “High Power” operation when in difficult terrain.
Press the assigned Soft key or switch the TOGGLE switch to the assigned position to ac­tivate the Talk Around feature when you are op­erating on duplex channel systems (separate re­ceive and transmit frequencies, utilizing a “re­peater” station). The Talk Around feature allows you to bypass the repeater station and talk directly to a station that is nearby. This feature has no ef­fect when you are operating on “simplex” chan­nels, where the receive and transmit frequencies are already the same.
Note that your dealer may have made provision for “Talk Around” channels by programming “re­peater” and “Talk Around” frequencies on two adjacent channels. If so, the key may be used for one of the other Pre-Programmed Functions.
TX Save Disable
Press the assigned Soft key or switch the TOGGLE switch to the assigned position to dis-
able the Transmit Battery Saver, if you are operat­ing in a location where high power is almost al­ways needed.
The Transmit Battery Saver helps extend battery life by reducing transmit power when a very strong signal from an apparently nearby station is being received. Under some circumstances, though, your hand-held radio may not be heard well at the other end of the communication path, and high power may be necessary at all times.
Encryption Disable
Press the assigned Soft key or switch the TOGGLE switch to the assigned position to turn off the op­tional voice encryption unit temporarily, for use when an incorrect setting of (or failure in) the encryption system at one end of the communication path has made it impossible to talk to the other station.
Remember that disabling the encryption will mean that your transmissions are no longer secure. Re­turn to the encrypted mode as soon as possible, and do not discuss any critical or confidential informa­tion while in the non-encrypted mode of operation.
VX-600U OPERATING MANUAL
Page 13
ADVANCED OPERATION
Lock
Switch the TOGGLE switch to lock the top-panel keys; this can be enabled to prevent radio settings from being disturbed.
Follow-Me Scan
“Follow-Me” Scan feature checks a User-assigned Priority Channel regularly as you scan the other channels. Thus, if only Channels 1, 3, and 5 (of the 8 available channels) are designated for “Scan­ning,” the user may nonetheless assign Channel 2 as the “User-assigned” Priority Channel via the “Follow-Me” feature.
To activate “Follow-Me” scanning, first select the channel you want to designate as the “User-As­signed Priority Channel” and switch the TOGGLE switch to the assigned position. Then turn the CH selector knob to the “Scanning Start” channel which has been programmed by your dealer to activate the scanner. When the scanner stops on an “Active” channel, the User-assigned Priority Channel will automatically be checked every few seconds; if activity is found on the User­assigned Priority Channel, the radio will switch between it and the Dealer-Assigned Priority Channel, if any.
VX-600U OPERATING MANUAL
Follow-Me DW
To set up a “Dual Watch” frequency pair using the “Follow-Me” feature, select a channel using the CH selector knob. Now press the assigned Soft key; pressing the assigned Soft key locks the current channel as the User-assigned Priority Channel. Now rotate the CH selector knob to another channel (not the “Scanning Start” channel). Your radio will now switch back-and-forth between the currently-se­lected channel (shown on the CH selector knob) and the User-assigned Priority Channel.
During “Follow-Me” scanning (after you have pressed the key), you can set up the “Dual Watch” feature by rotating the CH selector knob to an­other channel. The radio will then scan back and forth between the original User-assigned Priority Channel and the newly-selected channel.
The Priority Channel you have assigned (before pressing the key) will be retained in memory un­til you change it.
Channel Group Selection
The VX-600 is capable of separating its 48 memory channels into any of 3 Groups. There is no limit as to the number of channels which may be assigned to each Group. The Dealer will have
11
Page 14
made the Group assignment at the time of chan­nel programming. At the same time, one of the Soft keys will be assigned as the Channel Group Selection key.
To change Channel Groups, press the as­signed Soft key to step through the available Groups. Once the desired Group is reached, ro­tate the CH selector knob to select the desired channel within the selected Group.
You may wish to have the Scanner (described previously) pass through more than one Group during the scanning process (normally, scanning is performed within the current group only). To include the current Group in the scanning loop, press and hold in the assigned Soft key for one second.
To remove a Group from Group Scan, press and hold in the assigned Soft key again for one second.
Call/Reset (16-key version only)
This feature, if enabled, allows the user to change the 3-digit Page Call code, used to call other simi­larly-equipped stations. Press the Dealer-assigned Soft key, followed by the three digits represent­ing the Page Call code of the station you wish to
12
ADVANCED OPERATION
call. Three tones will be heard after the last key is pressed (the new code will now be transmit­ted).
The receiver squelch of the other station will be opened, and you can begin communication.
Speed Dial (16-key version only)
Your Dealer may have pre-programmed Auto-Dial telephone number memories into your radio.
To dial a number, press the Dealer-assigned Soft key for Speed Dialing, then press the numbered key corresponding to the Auto-Dial memory num­ber list provided by your Dealer. The DTMF tones sent during the dialing sequence will be heard in the speaker.
Emergency
The VX-600 includes an “Emergency” feature which may be useful if you have someone moni­toring on the same frequency as your transceiver’s channel. For further details contact your VER- TEX STANDARD dealer.
VX-600U OPERATING MANUAL
Page 15
ADVANCED OPERATION
ARTS (Auto Range Transponder System)
This system is designed to inform you when you and another ARTS-equipped station are within commu­nication range.
During ARTS operation, your radio automatically transmits for about 1 second every 25 seconds (the interval is programmed by the Dealer) in an attempt to shake hands with the other station.
If you move out of range for more than two minutes, your radio senses that no signal has been received, three beeps from the beeper will sound. If you sub­sequently move back into range, a single beep will be heard whenever your radio shakes hands with the other station.
DTMF Paging System
This system allows paging and selective calling, us­ing DTMF tone sequences.
When your radio is paged by a station bearing a tone sequence which matches yours, your radio’s squelch will open and the alert ringer will sound.
VX-600U OPERATING MANUAL
13
Page 16
UNDERSTANDING RADIO WAVES
Radio waves travel from one point to another by sev­eral different means. The general term for these meth­ods of wave travel is “propagation.” You may know that “shortwave” signals can be propagated over dis­tances of several thousand miles by reflection off of the upper regions of the atmosphere.
Your hand-held transceiver, on the other hand, oper­ates on the so-called UHF (Ultra-High Frequency) band. On this band, radio waves usually do not reflect off of the atmosphere. Instead, the radio waves behave almost as light: they travel in a straight line, and when they meet a building or obstruction, they go no further in that direction.
Therefore, it is important that you be as high and free from obstructions as possible to cover the greatest dis­tance when using your radio. If you operate from in­side a car or building, any metal around you can absorb much of the signal, both transmitted and received. Cov­erage may therefore be very poor under those condi­tions. However, if you must operate from indoors, mov­ing next to a window will improve communications.
In view of the factors just discussed, you can easily see the potential benefit of holding the radio up high near your mouth while transmitting. In this way the antenna is high and clear, and coverage is best.
14
On final note regarding propagation is useful in im­proving coverage. Because radio waves at UHF are similar to light waves, they do reflect, to varying de­grees, off of hills, buildings, and the like. In a crowded urban area, with many close buildings close together, many reflections may occur, and interfere with one another, causing variations in signal strength at dif­ferent locations.
Therefore, if a signal is weak and you walk a few feet in any direction, reception may suddenly become clear, because a particular reflection path may be­come dominant. Reflections are frequently useful, as they can allow for communications between two stations over a highly obstructed path.
VX-600U OPERATING MANUAL
Page 17
ACCESSORIES & OPTIONS
FVP-25 Encryption/DTMF Pager Unit F2D-8 2-Tone Decode Unit F5D-14 5-Tone ENC/DEC Unit FNB-V68LI 7.4 V 1800 mAh Lithium-Ion Battery FNB-V69LI 7.4 V 2400 mAh Lithium-Ion Battery FBA-27 Alkaline Battery Case (6 x AA) VAC-900 Rapid Desktop Charger VAC-6900 6-Unit Multi Charger VCM-1 Mobile Mounting Bracket VTP-50 VX-Trunk Unit MH-50
VH-110 Over the Head, Heavy Duty Headset VH-120 3-Wire Earpiece, Mic, Palm PTT Switch VH-130 2-Wire Earpiece, Palm Mic/PTT Combo VH-140 DSP VOX Earpiece Microphone VH-150 DSP VOX Bone-vibration Headset VH-160 Earpiece, Mic, Body PTT System VH-170 Bone-vibration Headset
Speaker/Microphone
A7A
(Noise Canceling)
CE39 Programming Software CT-70 Radio Programming Cable
(Requires VPL-1)
CT-71 PC Programming Cable CT-72 Radio to Radio Programming Cable ATU-6A UHF Antenna, 400 ~ 430 MHz ATU-6C UHF Antenna, 440 ~ 470 MHz ATU-6D UHF Antenna, 450 ~ 485 MHz
Availability of accessories may vary; some ac­cessories are supplied standard per local require­ments, others may be unavailable in some re­gions. Check with your VERTEX STANDARD Dealer for changes to this list.
VX-600U OPERATING MANUAL
15
Page 18
NOTE
16
VX-600U OPERATING MANUAL
Page 19
This device complies with Part 15 of the FCC rules. Operation is subject to the condition that this device does not cause harmful interference.
Page 20
Copyright 2001 VERTEX STANDARD CO., LTD. All rights reserved.
No portion of this manual may be reproduced without the permission of VERTEX STANDARD CO., LTD.
Printed in Japan
0104X-0E
E C 0 1 4 U 1 5 0
Loading...