Versitron SF71060M, SF71060MP Installation Manual

i
VERSITRON SF71060M & SF71060MP
Revision A3
Industrial 10-Port 10/100/1000Base
Managed PoE/PoE+ Switch
with 100/1000Base SFP Slots
IInnssttaallllaattiioonn GGuuiidde
e
vv11..000
0
© November 2017
VERSITRON, Inc.
83 Albe Drive / Suite C
Newark, DE 19702
www.versitron.com
ii
VERSITRON SF71060M & SF71060MP
Revision A3
Copyright VERSITRON, Inc. All rights reserved. All brand and product names are trademarks or registered trademarks of their respective companies.
PROPRIETARY DATA
All data in this manual is proprietary and may not be disclosed,
used or duplicated, for procurement or manufacturing purposes,
without prior written permission by VERSITRON.
VERSITRON LIFETIME WARRANTY
All VERSITRON products are covered by a Lifetime Warranty against defects in materials and workmanship. This coverage is applicable to the original purchaser and is not transferable.
We repair, or at our option, replace parts/products that, during normal usage and operation, are proven to be defective during the time you own the products, provided that said products and parts are still manufactured and/or available. Such repair/replacement is subsequent to receipt of your product at our facility and our diagnostic evaluation and review of the unit. Advance replacements are not provided as part of the warranty coverage.
This warranty does not cover damage to products caused by misuse, mishandling, power surges, accident, improper installation, neglect, alteration, improper maintenance, or other causes which are not normal and customary applications of the products and for which they were not intended. No other warranty is expressed or implied, and VERSITRON is not liable for direct, indirect, incidental or consequential damages or losses.
In the unlikely event a warranty issue should arise, simply contact us at 302-894-0699 or 1-800-537-2296 or via email at fiberlink@versitron.com to obtain a Return Material Authorization (RMA) number, along with instructions for returning your product.
iii
VERSITRON SF71060M & SF71060MP
Revision A3
About This Manual
Copyright
Copyright © 2017 VERSITRON, Inc. All rights reserved. The products and programs described in this manual are licensed products of VERSITRON, Inc. This manual contains proprietary information protected by copyright, and this manual and all accompanying hardware, software and documentation are copyrighted. No parts of this manual may be copied, photocopied, reproduced, translated or reduced to any electronic medium or machine-readable from by any means by electronic or mechanical. Including photocopying, recording, or information
storage and retrieval systems, for any purpose other than the purchaser’s personal use,
and without the prior express written permission of VERSITRON, Inc.
Purpose
This manual gives specific information on how to operate and use the management functions of the SF71060M & SF71060MP.
Audience
The Manual is intended for use by network administrators who are responsible for operating and maintaining network equipment; consequently, it assumes a basic working knowledge of general switch functions, the Internet Protocol (IP), and Simple Network Management Protocol (SNMP).
Conventions
The following conventions are used throughout this manual to show information.
NOTE: Emphasizes important information or calls your
attention to related features or instructions.
W
ARNING
:
Alerts you to potential hazard that could cause
personal injury.
C
AUTION
:
Alerts you to a potential hazard that could cause
loss of data, or damage the system or equipment.
Warranty
See the VERSITRON, Inc. warranty statement.
Disclaimer
VERSITRON, Inc. does not warrant that the hardware will work properly in all environments and applications, and marks no warranty and representation, either implied or expressed, with respect to the quality, performance, merchantability, or fitness for a particular purpose. VERSITRON, Inc. disclaims liability for any inaccuracies or omissions that may have occurred. Information in this User’s Manual is subject to change without notice and does not represent a commitment on the part of VERSITRON, Inc.. VERSITRON, Inc. assumes no responsibility for any inaccuracies that may be contained in this User’s Manual. VERSITRON, Inc. makes no commitment to
update or keep current the information in this User’s Manual, and reserves the righter to make improvements to this User’s Manual and /or to the products described in this User’s Manual, at any time without notice.
TRADEMARKS
Ethernet is a registered trademark of Xerox Corp.
FCC NOTICE
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) This device must accept any interference received, including the interference that
may cause undesired operation.
CE NOTICE
Marking by the symbol indicates compliance of this equipment to the EMC directive of the European Community. Such
marking is indicative that this equipment meets or exceeds the following technical standards:
EMC Class A
EN 61000-6-4:2007/A1:2011
EN 61000-3-2:2006/A1:2009/A2:2009
EN 61000-3-3:2008
EN 61000-6-2:2005
IEC 61000-4-2:2008
IEC 61000-4-3:2010
IEC 61000-4-4:2012
IEC 61000-4-5:2005
IEC 61000-4-6:2008
IEC 61000-4-8:2009
IEC 61000-4-11:2004
VERSITRON SF71060M & SF71060MP
-2-
Revision A3
Table of Contents
0B1. Introduction ...................................................................................................................................................... 4
1.1 Features ............................................................................................................................... 5
1.2 Product Panels ..................................................................................................................... 6
1.3 LED Indicators ...................................................................................................................... 7
1.4 Specifications ....................................................................................................................... 7
1B2. Installation ...................................................................................................................................................... 10
10B2.1 Unpacking .......................................................................................................................... 10
2.2 Safety Cautions .................................................................................................................. 10
12B2.3 DIN-Rail Mounting .............................................................................................................. 11
13B2.4 Panel Mounting ................................ ................................................................ .................. 13
14B2.5 Applying Power ................................ ................................................................ .................. 15
15B2.6 Alarm Relay Output ............................................................................................................ 17
2.7 Powered via PoE over Cat.5 (Standard Model) .................................................................. 18
2.8 Reset Button ...................................................................................................................... 18
2.9 Making UTP Connections ................................................................................................... 19
2.10 Making Fiber Connection .................................................................................................. 20
2.11 Making PoE PSE Connections (PoE Model) ..................................................................... 22
1306B2.12 LED Indication .................................................................................................................. 23
2.13 Making Console Connection ............................................................................................. 24
3. Manage the Switch ........................................................................................................................................ 25
3.1 IP Address & Password ...................................................................................................... 25
3.2 Configuring IP Address & Password via console and telnet ................................................ 25
3.3 Configuring IP Address via Web Interface .......................................................................... 26
3.4 Reference Manuals for Web, Console, Telnet Management ............................................... 28
3.5 Configuration for SNMP Management ................................................................................ 29
3.6 SNMP MIBs........................................................................................................................ 30
VERSITRON SF71060M & SF71060MP
-3-
Revision A3
0B1. Introduction
Model
Copper
ports
SFP slots
PoE PSE
function
Power via
DC input
Powered via PoE capable
Software managed
SF71060M
8
2 dual-speed
-  
SF71060MP
8
2 dual-speed
4 PSE ports
- 
The SF71060M & SF71060MP switches are Industrial 10/100/1000Base managed switches featuring:
Eight 10/100/1000Mbps copper ports Two dual-speed SFP slots for 100Base-FX or 1000Base-X
Model Definitions
VERSITRON SF71060M & SF71060MP
-4-
Revision A3
1.1 Features
Eight 10/100/1000Mbps RJ-45 and two dual-speed SFP slots All copper ports support auto-negotiation and auto-MDI/MDI-X detection. Two SFP slots support dual speed for 100BASE-FX and 1000BASE-X SFP modules. Full wire speed forwarding Supports 802.3x flow control for full-duplex and backpressure for half-duplex Port link aggregation function with LACP support Supports SFP with Digital Diagnostic Monitoring (DDM) Alternatively powered via PoE if direct DC power not available Optional four 802.3at-compliant PoE+ PSE ports SNMP private MIB for DDM status, reboot, TFTP firmware update (MIB file Rev1.05 or up) Optical Power Alarm (OPA) function Auto Laser Shutdown (ALS) function (supported in H/W Ver.E up)
Management:
- HTTP/HTTPS/SSHv2/CLI telnet/CLI console/SNMP v1/v2c/v3/RMON
- DHCP/DHCPv6 client, DHCP relay, DNS client, NTPv4
- IPv6 support, System Syslog, Configuration down/upload, Software upload
Security:
- NAS, 802.1X, MAC-based/Web/CLI authentication
- IP MAC binding, TACACS+, IP source guard
Layer 2:
- QoS, 802.1Q/MAC-based/Protocol-based/Private/IP subnet VLAN, Port Isolation
- Storm control for UC/MC/BC packets, Static MAC configuration
- IGMP v2/v3 snooping, MLD v1/v2 snooping, DHCP snooping
- Multiple Spanning Tree - MSTP. RSTP, STP
Auto Multi-Ring (KAMR) Technology:
- Fast failover response time, Auto recovery when failure is repaired
- Supports up to five redundant rings, Works with RSTP network
VERSITRON SF71060M & SF71060MP
-5-
Revision A3
1.2 Product Panels
The following figure illustrates the front panel and rear panel of the switch:
SF71060M Front panel
VERSITRON SF71060M & SF71060MP
SF71060MP Front panel
-6-
Revision A3
154BUpper panel
1.3 LED Indicators
LED Function
PWR Power status Mgt. Management status Port 1~ 8 SPEED LEDs Speed & PoE status Port 1~ 8 LINK LEDs Link & activity status SFP 9, 10 LED Speed & link & activity status of SFP port
1.4 Specifications
10/100/1000 Copper Ports (Port 1 ~ Port 8)
Compliance IEEE 802.3 10Base-T, IEEE 802.3u 100Base-TX, IEEE 802.3u 1000Base-T Connectors Shielded RJ-45 jacks Pin assignments Auto MDI/MDI-X detection Configuration Auto-negotiation or software control Transmission rate 10Mbps, 100Mbps, 1000Mbps Duplex support Full/Half duplex Network cable Cat.5 UTP
Dual-speed SFP Slots (Port 9, Port 10)
Compliance IEEE 802.3u 100Base-FX
IEEE 802.3z 1000Base-SX/LX (mini-GBIC)
Connectors SFP slots for optional SFP fiber modules
VERSITRON SF71060M & SF71060MP
-7-
Revision A3
Configuration Auto 1000Mbps, Full duplex
Forced 100Mbps, Full duplex Transmission rate 100Mbps and 1000Mbps Network cables MMF 50/125 60/125, SMF 9/125 Eye safety IEC 825 compliant
Console Port
Interface RS-232, DTE type
Connector Shielded RJ-45
Switch Functions
MAC Addresses Table 8K entries Forwarding & filtering Non-blocking, full wire speed Switching technology Store and forward Maximum packet length 9.6K bytes IP Multicast groups 8192 supported Flow control IEEE 802.3x pause frame base for full duplex operation
Back pressure for half duplex operation
Power over Ethernet PSE Function (SF71060MP)
PSE Ports Port 1 ~ Port 4 Power output pins Positive of power voltage: pin 1,2 Negative of power voltage: pin 3,6 Standard IEEE 802.3at Classification PD Class 0 ~ 4 detection Power Delivery 30W max. (per port) at port output for Cat.5 distance up to 100 meters Protection Under voltage protection Over voltage protection Over current detection
Powered via Power over Ethernet (SF71060M)
PD Port Port 2 PoE Standard IEEE 802.3af PoE PD (Powered Device) PSE Support IEEE 802.3af & 802.3at PSE Power Classification Class 3 Input Voltage (V
VERSITRON SF71060M & SF71060MP
) 36 ~ 57VDC via Cat.5
poe
-8-
Revision A3
Loading...
+ 23 hidden pages