Versa-Matic 1 1/2 Elima-Matic Bolted Metallic User Manual

Page 1
THIS IS A PROPRIETARY DOCUMENT. DO NOT REPRODUCE OR DISCLOSE
WITHOUT THE EXPRESS WRITTEN PERMISSION OF WARREN RUPP INC.
DESCRIPTION
WARREN RUPP INC.
E40 BOLTED PUMP
1 1/2" Elima-Matic Bolted Metallic
with Metallic Center Section
E40 Metallic Pumps
• Aluminum
• Cast Iron
• Stainless Steel
Original Instructions
E40
1: PUMP SPECS2: INSTAL & OP3: EXP VIEW4: WARRANTY
Service & Operating Manual
Versa-Matic
800 North Main Street, Mansfield, OH 44902 USA • Phone: (419) 526-7296 • www.versamatic.com
VERSA-MATIC
®
• Warren Rupp, Inc. • A Unit of IDEX Corporation
© Copyright 2014 Warren Rupp, Inc. All rights reserved
Page 2
Safety Information
IMPORTANT
Read the safety warnings and instructions in this manual before pump installation and start-up. Failure to comply with the recommendations stated in this manual could damage the pump and void factory warranty.
When the pump is used for materials that tend to settle out
or solidify, the pump should be ushed after each use to
prevent damage. In freezing temperatures the pump should be completely drained between uses.
CAUTION
Before pump operation, inspect all fasteners for loosening
caused by gasket creep. Retighten loose fasteners to prevent leakage. Follow recommended torques stated in this manual.
Nonmetallic pumps and plastic components are not UV stabilized. Ultraviolet radiation can damage these parts and negatively affect material properties. Do not expose to UV light for extended periods of time.
WARNING Pump not designed, tested or certied to be powered by compressed natural gas. Powering the pump with natural gas will void the warranty.
WARNING
When used for toxic or aggressive uids, the pump should always be ushed clean prior to disassembly.
Before maintenance or repair, shut off the compressed air line, bleed the pressure, and disconnect the air line from the pump.
Be certain that approved eye protection and protective clothing are worn at all times. Failure to follow these recommendations may result in serious injury or death.
Airborne particles and loud noise hazards. Wear eye and ear protection.
In the event of diaphragm rupture, pumped material may enter the air end of the pump, and be discharged into the atmosphere. If pumping a product that is hazardous or toxic, the air exhaust
must be piped to an appropriate area for safe containment.
Take action to prevent static sparking. Fire or explosion can
result, especially when handling ammable liquids. The pump, piping, valves, containers and other miscellaneous equipment
must be properly grounded.
This pump is pressurized internally with air pressure during operation. Make certain that all fasteners are in good condition and are reinstalled properly during reassembly.
kg
Use safe practices when lifting
Grounding the Pump
To be fully groundable, the pumps must be ATEX Compliant. Refer to the nomenclature page for ordering information.
Optional 8 foot long (244 centimeters) Ground Strap is available for easy ground connection.
To reduce the risk of static electrical sparking, this pump must be grounded. Check the local electrical code for detailed grounding instruction and the type of equipment required.
Refer to nomenclature page for ordering information.
WARNING
Take action to prevent static sparking.
Fire or explosion can result, especially when handling ammable liquids. The pump, piping, valves, containers or
other miscellaneous equipment must be grounded.
ww w. ve rs am ati c. co m
e40mdlCsmATEX-rev0514
Page 3
Table of Contents
SECTION 1: PUMP SPECIFICATIONS ................1
• Nomenclature
• Performance
• Materials
• Dimensional Drawings
SECTION 2: INSTALLATION & OPERATION ......5
• Principle of Pump Operation
• Typical Installation Guide
• Troubleshooting
SECTION 3: EXPLODED VIEW ...........................8
• Composite Drawings
• Parts List
• Materials Code
1: PUMP SPECS2: INSTAL & OP3: EXP VIEW4: WARRANTY
SECTION 4: WARRANTY & CERTIFICATES ....12
• Warranty
• CE Declaration of Conformity - Machinery
• CE Declaration of Conformity - ATEX
e40mdlCsmATEX-rev0514
ww w. ve rs am ati c. co m
Page 4
Explanation of Pump Nomenclature
Your Serial #: (ll in from pump nameplate) _____________________________________
1: PUMP SPECS
Your Model #:
(ll in from pump nameplate)
__ __ __ __ __ __ __ __ __ __ __ __ __
Model #:
Options (if applicable)
Design Level
Construction Design
Valve Seat Material/Valve Seat O-Ring Material
Valve Ball Material
Diaphragm Series
Diaphragm Material
Non-Wetted Parts
Wetted Parts
Pump Size
Model
Model Pump Size Wetted Parts Non-Wetted Parts Diaphragm Material E Elima-Matic 6 1/4" A Aluminum A Aluminum 1 Neoprene U Ultra-Matic 8 3/8" C Cast Iron S Stainless Steel 2 Nitrile (Nitrile) V V-Series 5 1/2" S Stainless Steel P Polypropylene 3 FKM (Fluorocarbon) RE AirVantage 7 3/4" H Alloy C G Groundable Acetal 4 EPDM
1 1" P Polypropylene Z PTFE-coated Aluminum 5 PTFE 4 1-1/4" or 1-1/2" K Kynar J Nickel-plated Aluminum 6 Santoprene XL 2 2" G Groundable Acetal C Cast Iron 7 Hytrel 3 3" B Aluminum (screen mount) Q Epoxy-Coated Aluminum 9 Geolast Y FDA Santoprene
Diaphragm Series Valve Ball Material Valve Seat/Valve Seat O-Ring Material Construction Design Miscellaneous Options R Rugged 1 Neoprene 1 Neoprene 9 Bolted B BSP Tapered Thread D Dome 2 Nitrile 2 Nitrile 0 Clamped CP Center Port X Thermo-Matic 3 (FKM) Fluorocarbon 3 (FKM) Fluorocarbon ATEX ATEX Compliant T Tef-Matic (2-piece) 4 EPDM 4 EPDM Design Level FP Food Processing B Versa-Tuff (1-piece) 5 PTFE 5 PTFE A SP Sanitary Pump F FUSION (one-piece 6 Santoprene XL 6 Santoprene XL C HP High Pressure
integrated plate) 7 Hytrel 7 Hytrel OE Original Elima-Matic 8 Polyurethane 8 Polyurethane F Flap Valve 9 Geolast 9 Geolast HD Horizontal Discharge A Acetal A Aluminum w/ PTFE O-Rings 3A 3-A Certied S Stainless Steel S Stainless Steel w/ PTFE O-Rings UL UL Listed Y FDA Santoprene C Carbon Steel w/ PTFE O-Rings OB Oil Bottle H Alloy C w/ PTFE O-Rings T PTFE Encapsulated Silicone O-Rings Y FDA Santoprene
*More than one option may be specied for a particular pump model.
1 • Model E40 Metallic
ww w. ve rs am ati c. co m
e40mdlCsmATEX-rev0514
Page 5
Materials
Material Prole:
CAUTION! Operating temperature limitations are as follows:
Conductive Acetal: Tough, impact resistant, ductile. Good abrasion resistance and low friction surface. Generally inert, with good chemical resistance except for strong acids and oxidizing agents.
EPDM: Shows very good water and chemical resistance. Has poor resistance to oils and solvents, but is fair in ketones and alcohols.
FKM: (Fluorocarbon) Shows good resistance to a wide range of oils and sovents; especially all aliphatic, aromatic and halogenated hydrocarbons, acids, animal and vegetable oils. Hot water or hot aqueous solutions (over 70°F) will attack FKM.
Hytrel®: Good on acids, bases, amines and glycols at room temperatures only.
Neoprene: All purpose. Resistance to vegetable oils. Generally not affected by moderate chemicals, fats, greases and many oils and solvents. Generally attacked by strong oxidizing acids, ketones, esters and nitro hydrocarbons and chlorinated aromatic hydrocarbons.
Nitrile: General purpose, oil-resistant. Shows good solvent, oil,
water and hydraulic uid resistance. Should not be used with
highly polar solvents like acetone and MEK, ozone, chlorinated hydrocarbons and nitro hydrocarbons.
Nylon: 6/6 High strength and toughness over a wide temperature range. Moderate to good resistance to fuels, oils and chemicals.
Operating
Temperatures:
Max. Min.
190°F
88°C
280°F 138°C
350°F 177°C
220°F 104°C
200°F
93°C
190°F
88°C
180°F
82°C
-20°F
-29°C
-40°F
-40°C
-40°F
-40°C
-20°F
-29°C
-10°F
-23°C
-10°F
-23°C
32°F
0°C
Polypropylene: A thermoplastic polymer. Moderate tensile
and ex strength. Resists stong acids and alkali. Attacked by
chlorine, fuming nitric acid and other strong oxidizing agents.
PVDF: (Polyvinylidene Fluoride) A durable uoroplastic with
excellent chemical resistance. Excellent for UV applications. High tensile strength and impact resistance.
Santoprene®: Injection molded thermoplastic elastomer with
no fabric layer. Long mechanical ex life. Excellent abrasion
resistance.
UHMW PE: A thermoplastic that is highly resistant to a broad range of chemicals. Exhibits outstanding abrasion and impact resistance, along with environmental stress-cracking resistance.
Urethane: Shows good resistance to abrasives. Has poor resistance to most solvents and oils.
Virgin PTFE: (PFA/TFE) Chemically inert, virtually impervious. Very few chemicals are known to chemically react with PTFE;
molten alkali metals, turbulent liquid or gaseous uorine and a few uoro-chemicals such as chlorine triuoride or oxygen diuoride which readily liberate free uorine at elevated
temperatures.
Maximum and Minimum Temperatures are the limits for which these materials can be operated. Temperatures coupled with pressure affect the longevity of diaphragm pump components. Maximum life should not be expected at the extreme limits of the temperature ranges.
180°F
82°C
250°F 121°C
275°F 135°C
180°F
82°C
150°F
66°C
220°F 104°C
32°F
0°C
0°F
-18°C
-40°F
-40°C
-35°F
-37°C
32°F
0°C
-35°F
-37°C
Metals:
Alloy C: Equal to ASTM494 CW-12M-1 specication for nickel and nickel alloy.
Stainless Steel: Equal to or exceeding ASTM specication A743 CF-8M for corrosion
resistant iron chromium, iron chromium nickel and nickel based alloy castings for general applicaitons. Commonly referred to as 316 Stainless Steel in the pump industry.
For specic applications, always consult the Chemical Resistance Chart.
1: PUMP SPECS
AFTERMARKET PARTS
RIGHT PART, RIGHT NOW
Pumper Parts is your single source for parts that
t Air-Operated Double Diaphragm (AODD) pumps
• Wilden
• ARO
• Yamada
Designed to perform equal to or greater than original equipment manufacture.
Pumper Parts and its products are not affiliated with any of the original equipment manufacturers referenced herein. All original equipment manufacturers’ names, colors, pictures, descriptions and part numbers are used for identification purposes only. Pumper Parts® is a registered trade name of IDEX Corporation. All other trademarks, registered trademarks and product names are the property of their respective owners. Yamada® is a registered trademark of Yamada Corporation. ARO® is a registered trade name of Ingersoll-Rand Company. Wilden® is a registered trade name of Wilden Pump and Engineering Company, a Dover Resources Company.
®
®
®
Phone: (419) 526-7296
info@pum perparts.com
www.pumperparts.com
e40mdlCsmATEX-rev0514
ww w. ve rs am ati c. co m
Model E40 Metallic • 2
Page 6
Performance
85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10
Displacement Per Stroke: 0.44 Gal (1.67 L)
10
Capacity Per Stroke: 0.30 Gal (1.14 L)
E40 1 1/2" Bolted Pump- Metallic Center ELASTOMERIC AND TPE FITTED
Flow Rate
Adjustable to ....... 0-123 gpm (465 lpm)
Port Size
Suction .................... 1 1/2" NPT
Discharge..................1 1/2" NPT
Air Inlet ......................1/2" NPT
Air Exhaust ................... 1" NPT
Suction Lift
Dry ........................19' (5.8 m)
Wet........................31' (9.4 m)
Max Solid Size (Diameter)
1: PUMP SPECS
..........................1/4" (6 mm)
Max Noise Level ............101 dB(A)
Shipping Weights
Aluminum ................55 lbs (25 kg)
Cast Iron.................95 lbs (43 kg)
Stainless Steel ............92 lbs (42 kg)
**w/ Stainless Center add 21 lbs (9.5 kg)
280
5 0
s Feet
300
260 240 220 200 180 160 140 120 100
80 60 40 20
140
9
8
7
6
5
4
3
2
1
0
0
BAR
10
120
100
20
30
40
50
60
80
60
40
AIR CONSUMPTION IN SCFM AIR PRESSURE IN PSI
SCFM M3/HR
10 17 20 34 30 51 40 68 50 85 60 101.9
Discharge Head in PSI
20
0
0 20 40 60 80 100 120
140
Capacity in U.S. Gallons Per Minute
E40 1 1/2" Bolted Pump - Metallic Center PTFE Fitted
Flow Rate
Adjustable to ......0-103 gpm (389.9 lpm)
Port Size
Suction .................... 1 1/2" NPT
Discharge..................1 1/2" NPT
Air Inlet ......................1/2" NPT
Air Exhaust ................... 1" NPT
Suction Lift
Dry ........................12' (3.7 m)
Wet........................29' (8.8 m)
Max Solid Size (Diameter)
..........................1/4" (6 mm)
Max Noise Level .............98 dB(A)
Shipping Weights
Aluminum ................55 lbs (25 kg)
Cast Iron.................95 lbs (43 kg)
Stainless Steel ............92 lbs (42 kg)
**w/ Stainless Center add 21 lbs (9.5 kg)
NOTE: Performance based on the following: elastomeric tted pump, ooded suction, water at ambi­ent conditions. The use of other materials and varying hydraulic conditions may result in deviations in excess of 5%.
10
320
140
9
280
120
8
240
200
160
120
80
40
0
s Feet
BAR
100
7
6
80
5
60
4
3
40
Discharge Head in PSI
2
20
1
0
0
NOTE: Performance based on the following: PTFE tted pump, ooded suction, water at ambient conditions. The use of other materials and varying hydraulic conditions may result in deviations in excess of 5%.
0 20 60 100 140
180
300220 260 340 460 500
380
420
Capacity in Liters Per Minute
10
20
30
40
50
60
0 20 40 60 80 100 120
AIR CONSUMPTION IN SCFM AIR PRESSURE IN PSI
SCFM M3/HR 10 17 20 34 30 51 40 68 50 85 60 101.9
Capacity in U.S. Gallons Per Minute
20 60 100 140 180 220 380 420300260 340
0
Capacity in Liters Per Minute
3 • Model E40 Metallic
ww w. ve rs am ati c. co m
e40mdlCsmATEX-rev0514
Page 7
Dimensional Drawings
4X
R.20
5.08
E40 Metallic Center
Dimensions in inches (metric dimensions in brackets)
The dimensions on this drawing are for reference only. A certied drawing can be requested if physical dimensions are needed.
18.55
471.17
1.5" NPT / BSP TAPERED
DISCHARGE PORT
20.90
530.86
18.32
465.23
1/2" NPT
AIR INLET
2.25
57.15
12.22
310.29
1: PUMP SPECS
22.20
563.75
4X
3.13
79.46
1.5" NPT / BSP TAPERED
SUCTION PORT
R.20
5.08
8.13
206.38
244.48
9.63
8.30
210.69
1" NPT
EXHAUST PORT
6.00
12.70
.50
2.25
57.15
152.40
1.50
38.10
e40mdlCsmATEX-rev0514
BOTTOM VIEW
ww w. ve rs am ati c. co m
Model E40 Metallic • 4
Page 8
Principle of Pump Operation
SAFE AIR EXHAUST DISPOSAL AREA
MUFFLER
Air-Operated Double Diaphragm (AODD) pumps are powered by compressed air or nitrogen.
Discharged Stroke
2: INSTAL & OP
Air Line
Discharged Fluid
Suction Stroke
The main directional (air) control valve compressed air to an air chamber, exerting uniform pressure over the inner surface of the diaphragm the exhausting air is directed through the air valve assembly(s) to an exhaust port
.
As inner chamber pressure pressure together creating discharge on one side and suction on the opposite side. The discharged and primed liquid’s directions
are controlled by the check valves (ball or ap)
The pump primes as a result of the suction stroke. The suction stroke lowers the chamber pressure the chamber volume. This results in a pressure differential necessary for atmospheric pressure through the suction piping and across the suction side check
valve and into the outer uid chamber
Suction (side) stroking also initiates the reciprocating (shifting, stroking or cycling) action of the pump. The suction diaphragm’s movement is mechanically pulled through its stroke. The diaphragm’s inner plate makes contact with an actuator plunger aligned to shift the pilot signaling valve. Once actuated, the pilot valve sends a pressure signal to the opposite end of the main directional air valve, redirecting the compressed air to the opposite inner chamber.
(P2), the rod
from behind the opposite diaphragm
(P1) exceeds liquid chamber
connected diaphragms shift
distributes
. At the same time,
orientation.
(P3) increasing
(P4) to push the uid
.
5 • Model E40 Metallic
Primed Fluid
SUBMERGED ILLUSTRATION
MUFFLER
LIQUID LEVEL
SUCTION
LINE
Pump can be submerged if the pump materials of construction are compatible with the liquid being pumped. The air exhaust must be piped above the liquid level. When the pumped product
source is at a higher level than the pump (ooded suction
condition), pipe the exhaust higher than the product source to prevent siphoning spills.
ww w. ve rs am ati c. co m
1" DIAMETER AIR EXHAUST PIPING
e40mdlCsmATEX-rev0514
Page 9
Recommended Installation Guide
Available Accessories:
1. Surge Suppressor
2. Filter/Regulator
3. Air Dryer
Unregulated Air
Supply to Surge
Suppressor
1
Surge Suppressor
Pressure Gauge
Shut-Off Valve
Note: Surge Suppressor and Piping must be supported after
the exible connection.
(Optional Piped Exhaust)
Flexible Connector
Vacuum
Gauge
Suction
Shut-Off Valve
Drain Port
Muffler
Pipe Connection
(Style Optional)
Flexible Connector
Pipe Connection (Style Optional)
Drain Port
Flexible Connector
Discharge
2
3
Filter Regulator P/N: 020.V107.000
Air Dryer
Note: Pipe weight should not be supported by pump connections.
CAUTION
Check Valve
Shut-Off Valve
Air Inlet
2: INSTAL & OP
The air exhaust should be piped to an area for safe disposition of the product being
pumped, in the event of
a diaphragm failure.
Installation And Start-Up
Locate the pump as close to the product being pumped as possible. Keep the suction line length and number of ttings to a minimum. Do not reduce the suction line
diameter.
Air Supply
Connect the pump air inlet to an air supply with sufcient capacity and pressure to achieve desired performance. A pressure regulating valve should be installed to
insure air supply pressure does not exceed recommended limits.
Air Valve Lubrication The air distribution system is designed to operate WITHOUT lubrication. This is the standard mode of operation. If lubrication is desired, install an air line lubricator set to deliver one drop of SAE 10 non-detergent oil for every 20 SCFM (9.4 liters/sec.) of air the pump consumes. Consult the Performance Curve to determine air consumption.
Air Line Moisture Water in the compressed air supply may cause icing or freezing of the exhaust air, causing the pump to cycle erratically or stop operating. Water in the air supply can be reduced by using a point-of-use air dryer.
Air Inlet And Priming
To start the pump, slightly open the air shut-off valve. After the pump primes, the air valve can be opened to increase air ow as desired. If opening the valve increases cycling rate, but does not increase the rate of ow, cavitation has occurred. The valve should be closed slightly to obtain the most efcient air ow to pump ow ratio.
e40mdlCsmATEX-rev0514
ww w. ve rs am ati c. co m
Model E40 Metallic • 6
Page 10
Troubleshooting Guide
Symptom: Potential Cause(s): Recommendation(s):
Pump Cycles Once
Pump Will Not Operate / Cycle
Pump Cycles and Will Not Prime or No Flow
Pump Cycles Running
2: INSTAL & OP
Sluggish/Stalling, Flow Unsatisfactory
Product Leaking Through Exhaust
Premature Diaphragm Failure
Unbalanced Cycling
Deadhead (system pressure meets or exceeds air supply pressure).
Air valve or intermediate gaskets installed incorrectly. Install gaskets with holes properly aligned.
Bent or missing actuator plunger. Remove pilot valve and inspect actuator plungers.
Pump is over lubricated. Set lubricator on lowest possible setting or remove. Units are designed for lube free operation.
Lack of air (line size, PSI, CFM). Check the air line size and length, compressor capacity (HP vs. cfm required).
Check air distribution system. Disassemble and inspect main air distribution valve, pilot valve and pilot valve actuators.
Discharge line is blocked or clogged manifolds. Check for inadvertently closed discharge line valves. Clean discharge manifolds/piping.
Deadhead (system pressure meets or exceeds air supply pressure).
Blocked air exhaust mufer. Remove mufer screen, clean or de-ice, and re-install.
Pumped uid in air exhaust mufer. Disassemble pump chambers. Inspect for diaphragm rupture or loose diaphragm plate assembly.
Pump chamber is blocked. Disassemble and inspect wetted chambers. Remove or ush any obstructions.
Cavitation on suction side. Check suction condition (move pump closer to product).
Check valve obstructed. Valve ball(s) not seating properly or sticking.
Valve ball(s) missing (pushed into chamber or manifold).
Valve ball(s)/seat(s) damaged or attacked by product. Check Chemical Resistance Guide for compatibility.
Check valve and/or seat is worn or needs adjusting. Inspect check valves and seats for wear and proper setting. Replace if necessary.
Suction line is blocked. Remove or ush obstruction. Check and clear all suction screens or strainers.
Excessive suction lift. For lifts exceeding 20’ of liquid, lling the chambers with liquid will prime the pump in most cases.
Suction side air leakage or air in product. Visually inspect all suction-side gaskets and pipe connections.
Pumped uid in air exhaust mufer. Disassemble pump chambers. Inspect for diaphragm rupture or loose diaphragm plate assembly.
Over lubrication. Set lubricator on lowest possible setting or remove. Units are designed for lube free operation.
Icing. Remove mufer screen, de-ice, and re-install. Install a point of use air drier.
Clogged manifolds. Clean manifolds to allow proper air ow
Deadhead (system pressure meets or exceeds air supply pressure).
Cavitation on suction side. Check suction (move pump closer to product).
Lack of air (line size, PSI, CFM). Check the air line size, length, compressor capacity.
Excessive suction lift. For lifts exceeding 20’ of liquid, lling the chambers with liquid will prime the pump in most cases.
Air supply pressure or volume exceeds system hd. Decrease inlet air (press. and vol.) to the pump. Pump is cavitating the uid by fast cycling.
Undersized suction line. Meet or exceed pump connections.
Restrictive or undersized air line. Install a larger air line and connection.
Suction side air leakage or air in product. Visually inspect all suction-side gaskets and pipe connections.
Suction line is blocked. Remove or ush obstruction. Check and clear all suction screens or strainers.
Pumped uid in air exhaust mufer. Disassemble pump chambers. Inspect for diaphragm rupture or loose diaphragm plate assembly.
Check valve obstructed. Disassemble the wet end of the pump and manually dislodge obstruction in the check valve pocket.
Check valve and/or seat is worn or needs adjusting. Inspect check valves and seats for wear and proper setting. Replace if necessary.
Entrained air or vapor lock in chamber(s). Purge chambers through tapped chamber vent plugs. Purging the chambers of air can be dangerous.
Diaphragm failure, or diaphragm plates loose. Replace diaphragms, check for damage and ensure diaphragm plates are tight.
Diaphragm stretched around center hole or bolt holes. Check for excessive inlet pressure or air pressure. Consult Chemical Resistance Chart for compatibility
Cavitation. Enlarge pipe diameter on suction side of pump.
Excessive ooded suction pressure. Move pump closer to product. Raise pump/place pump on top of tank to reduce inlet pressure.
Misapplication (chemical/physical incompatibility). Consult Chemical Resistance Chart for compatibility with products, cleaners, temperature limitations
Incorrect diaphragm plates or plates on backwards, installed incorrectly or worn.
Excessive suction lift. For lifts exceeding 20’ of liquid, lling the chambers with liquid will prime the pump in most cases.
Undersized suction line. Meet or exceed pump connections.
Pumped uid in air exhaust mufer. Disassemble pump chambers. Inspect for diaphragm rupture or loose diaphragm plate assembly.
Suction side air leakage or air in product. Visually inspect all suction-side gaskets and pipe connections.
Check valve obstructed. Disassemble the wet end of the pump and manually dislodge obstruction in the check valve pocket.
Check valve and/or seat is worn or needs adjusting. Inspect check valves and seats for wear and proper setting. Replace if necessary.
Entrained air or vapor lock in chamber(s). Purge chambers through tapped chamber vent plugs.
Increase the inlet air pressure to the pump. Pump is designed for 1:1 pressure ratio at zero ow. (Does not apply to high pressure 2:1 units).
Increase the inlet air pressure to the pump. Pump is designed for 1:1 pressure ratio at zero ow. (Does not apply to high pressure 2:1 units).
Disassemble the wet end of the pump and manually dislodge obstruction in the check valve pocket. Clean out around valve ball cage and valve seat area. Replace valve ball or valve seat if damaged. Use heavier valve ball material.
Worn valve ball or valve seat. Worn ngers in valve ball cage (replace part). Check Chemical Resistance Guide for compatibility.
Increase the inlet air pressure to the pump. Pump is designed for 1:1 pressure ratio at zero ow. (Does not apply to high pressure 2:1 units).
with products, cleaners, temperature limitations and lubrication.
Install Back pressure device (Tech bulletin 41r). Add accumulation tank or pulsation dampener.
and lubrication.
Check Operating Manual to check for correct part and installation. Ensure outer plates have not been worn to a sharp edge.
For additional troubleshooting tips contact After Sales Support at service.warrenrupp@idexcorp.com or 419-524-8388
7 • Model E40 Metallic
ww w. ve rs am ati c. co m
e40mdlCsmATEX-rev0514
Page 11
Composite Repair Parts Drawing
2
5
8
11
35
36
38
35
36
11
30
METALLIC SEAT OPTION
32
33
31
31
21
15 14
16
30
29
26
27
18
20
22
28
2
3
12
13
19
25
23
24
38
8
5
4
7
6
9
10
11
37
37
3: EXP VIEW
17
39
34
36
37
32
35
36
e40mdlCsmATEX-rev0514
30
ww w. ve rs am ati c. co m
Model E40 Metallic • 8
Page 12
Composite Repair Parts List
Air Valve Assembly
Item # Qty. Description
1 1 Valve Body Assembly (includes items 2-11) 031.V001.156 031.V001.110 031.V001.332 031.V002.309 2 1 Valve Body 095.V001.156 095.V001.110 095.V001.332 095.V001.309 3 1 Valve Body Gasket P24-202 4 1 Valve Sleeve 755.V001.148 5 6 O-ring 560.206.360 6 1 Valve Spool Assembly (Includes items 7) 775.V001.000 7 6 Glyde Ring Assembly P34-204F 8 1 Air Valve Screen P24-210 P34-210 P24-210 P24-210
9 2 End Cap Gasket P24-205 10 2 End Cap P34-300 SP34-300 P34-300TC 11 13 Mounting Screws S1001
Item # Qty. Description
12 1 Center Block Assembly (Includes item 13 & 14) P24-400DC ASY SP24-400 P24-401NP 13 2 Bearing Sleeve P31-403 14 2 Main Shaft O-Ring P24-403 15 2 Air Chamber 196.V003.156 196.V003.110 196.V003.332 16 2 Air Chamber Gasket 360.V001.465 17 8 Bolt P24-110 SP24-110 18 1 Pilot Sleeve Assembly (include items 19 & 20) 755.V002.000 19 6 O-ring 560.101.358 20 1 Retaining Ring 675.037.080 21 1 Pilot Spool Assembly (Includes item 22) 775.V002.000 22 8 O-ring 560.023.358 23 1 Mufer Elbow P126-0072 24 1 Mufer 530.033.000
Item # Qty. Description
25 1 Main Shaft P24-103 26 2 Diaphragm (See Below Material Chart) V227xx 27 2 Inner Diaphragm Plate (See Note 3) V226B, V226BNP, V226BTC, SV226B 28 2 Bumper Washer P24-501 29 2 Outer Diaphragm Plate VB226 SVB226 30 4 Valve Seat (See Below Material Chart) 722.091.xxx 31 8 Valve Seat O-Ring (See Below Material Chart) (See Note 2) 32 4 Valve Ball (See Below Material Chart) 050.005.xxx
Item # Qty. Description
33 2 Water Chamber 196.V001.156 196.V001.010 196.V001.110 34 20 Water Chamber Bolt 170.069.330 170.069.115
3: EXP VIEW
35 16 Manifold Bolt 170.085.330 170.085.115 36 36 Washer 901.038.330 901.038.115 37 36 Nut V185B SV185B 38 1 Discharge Manifold 518.V008.156 518.V008.010 518.V008.110 39 1 Suction Manifold 518.V009.156 518.V009.010 518.V009.110
Material "Versa-Dome Diaphragm P/N" "Ball P/N" Seat P/N
Neoprene V227N 050.005.365 722.091.365 560.084.365
Nitrile V227BN 050.005.360 722.091.360 560.084.360
FKM V227VT 050.005.363 722.091.363 560.084.363
EPDM V227ND 050.005.364 722.091.364 560.084.364
PTFE N/A (see PTFE tted manual) 050.010.600 722.091.600 720.061.608
Santoprene V227TPEXL 050.005.354 N/A 560.084.354
Hytrel V227TPEFG N/A N/A 720.061.608
Aluminum N/A N/A 722.091.150 (See Note 1 Below) 720.061.608
Carbon Steel N/A N/A 722.091.080 (See Note 1 Below) 720.061.608
Stainless Steel N/A 050.026.110 722.091.110 (See Note 1 Below) 720.061.608
Notes:
1.) The metallic seat material is to match the water chamber material. In addition to this seat, (8) O-Rings are needed.(Ref Note 2)
2.) These (8) O-Rings are only used with metallic tted seats. The O-Ring material is to match the diaphragm material.
3.) The inner diaphragm plate is to match the inner chamber material (Ref. Note 4)
4.) V = Aluminum, TC = PTFE Coated, NP = Nickel Plated, SV = Stainless Steel
Diaphragm Assembly / Elastomers
Elastomer Material Specications
Aluminum Stainless Steel Nickle Plated PTFE Coated
Center Section Assembly
Aluminum Stainless Steel Nickle Plated
Aluminum Cast Iron Stainless
Wet End Assembly
Aluminum Cast Iron Stainless
Part Number
Part Number
Part Number
Part Number
(See Note 2 Below)"
"Seat O-ring
9 • Model E40 Metallic
ww w. ve rs am ati c. co m
e40mdlCsmATEX-rev0514
Page 13
Composite Repair Parts Drawing - PTFE Fitted
2
3
4
5
6
7
9
10
11
11
12
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
31
33
33
35
34
36
36
37
37
37
38
38
38
39
40
13
36
8
29
2
4
5
11
36
37
39
8
2
3
4
5
10
11
12
15
16
18
19
20
21
22
33
36
37
39
13
8
26
25
29
FUSION DIAPHRAGM ASSEMBLY
29
25
FUSION DIAPHRAGM ASSEMBLY
26
METALLIC SEAT OPTION
31
32
32
3: EXP VIEW
e40mdlCsmATEX-rev0514
ww w. ve rs am ati c. co m
Model E40 Metallic • 10
Page 14
Composite Repair Parts List - PTFE Fitted
Air Valve Assembly
Item # Qty. Description
1 1 Valve Body (includes items 2-11) 031.V001.156 031.V001.110 031.V001.332 031.V001.309
2 1 Valve Body 095.V001.156 095.V001.110 095.V001.332 095.V001.309
3 1 Valve Body Gasket P24-202
4 1 Valve Sleeve 755.V001.148
5 6 O-ring 560.206.360
6 1 Valve Spool Assembly (Includes items 7) 775.V001.000
7 6 Glyde Ring Assembly P34-204F
8 1 Air Valve Screen P24-210 P34-210 P24-210
9 2 End Cap Gasket P24-205 10 2 End Cap P34-300 SP34-300 P34-300TC 11 13 Mounting Screws S1001
Item # Qty. Description Part Number
12 1 Center Block Assembly (Includes item 13 & 14) P24-400DC ASY SP24-400 P24-401NP P24-401TC 13 2 Bearing Sleeve P31-403 14 2 Main Shaft O-Ring P24-403 15 2 Air Chamber 196.V003.156 196.V003.110 196.V003.332 196.V003.309 16 2 Air Chamber Gasket 360.V001.465 17 8 Bolt P24-110 SP24-110 18 1 Pilot Sleeve Assembly (include items 19 & 20) 755.V002.000 19 6 O-ring 560.101.358 20 1 Retaining Ring 675.037.080 21 1 Pilot Spool Assembly (Includes item 22) 775.V002.000 22 8 O-ring 560.023.358 23 1 Mufer Elbow P126-0072 24 1 Mufer 530.033.000
Item # Qty. Description
25 1 Main Shaft P24-102 P24-103F 26 2 Diaphragm V227TF V227F 27 2 Back Up Diaphragm V227TFB N/A 28 2 Inner Diaphragm Plate (See Note 3) 29 2* Bumper Washer P24-501* (See note 5) 30 2 Outer Diaphragm Plate SVB226 N/A 31 4 Valve Seat (See Below Material Chart) 722.091.xxx 32 8 Valve Seat O-Ring (See Below Material Chart) (See Note 2) 33 4 Valve Ball (See Below Material Chart) 050.005.xxx
Item # Qty. Description Part Number
3: EXP VIEW
34 2 Water Chamber 196.V001.156 196.V001.010 196.V001.110 35 20 Water Chamber Bolt 170.069.330 170.069.115 36 16 Manifold Bolt 170.085.330 170.085.115 37 36 Washer 901.038.330 901.038.115 38 36 Nut V185B SV185B 39 1 Discharge Manifold 518.V008.156 518.V008.010 518.V008.110 40 1 Suction Manifold 518.V009.156 518.V009.010 518.V009.110
Material "Versa-Dome Diaphragm P/N" "Ball P/N" Seat P/N
PTFE N/A (see PTFE tted manual) 050.010.600 722.091.600 N/A
Aluminum N/A N/A
Carbon Steel N/A N/A
Stainless Steel N/A V241SS
Aluminum Stainless Steel Nickle Plated PTFE Coated
Center Section Assembly
Aluminum Stainless Steel Nickle Plated PTFE Coated
Diaphragm Assembly / Elastomers
PTFE 2 Piece Fusion
Aluminum Cast Iron Stainless Aluminum Cast Iron Stainless
V221TI, V221TINP, V221TINP, SV221TI* (See note 5)
Wet End Assembly
Aluminum Cast Iron Stainless
Elastomer Material Specications
Part Number
Part Number
N/A
(See Note 2 Below)"
722.091.150
(See Note 1 Below)
722.091.080
(See Note 1 Below)
722.091.110
(See Note 1 Below)
"Seat O-ring
720.061.608
720.061.608
720.061.608
Notes:
1.) The metallic seat material is to match the water chamber material. In addition to this seat, (8) O-Rings are needed.(Ref Note 2)
2.) These (8) O-Rings are only used with metallic tted seats. The O-Ring material is to match the diaphragm material.
3.) The inner diaphragm plate is to match the inner chamber material (Ref. Note 4)
4.) V = Aluminum, TC = PTFE Coated, NP = Nickel Plated, SV = Stainless Steel
5.) For Pumps with Stainless center pumps, increase quantity to 4
11 • Model E40 Metallic
ww w. ve rs am ati c. co m
e40mdlCsmATEX-rev0514
Page 15
Written Warranty
5 - YEAR Limited Product Warranty
Quality System ISO9001 Certied • Environmental Management Systems ISO14001 Certied
Versa-Matic warrants to the original end-use purchaser that no product sold by
Versa-Matic that bears a Versa-Matic brand shall fail under normal use and service due to a defect in material
or workmanship within ve years from the date of shipment from Versa-Matic’s factory.
~ See complete warranty at http://www.versamatic.com/pdfs/VM%20Product%20Warranty.pdf ~
DECLARATION OF CONFORMITY
DECLARATION DE CONFORMITEDECLARACION DE CONFORMIDADERKLÄRUNG BEZÜGLICH EINHALTUNG DER VORSCHRIFTEN
MANUFACTURED BY:
FABRIQUE PAR: FABRICADA POR: HERGESTELLT VON: FABBRICATO DA: VERVAARDIGD DOOR: TILLVERKAD AV: FABRIKANT: VALMISTAJA: PRODUSENT: FABRICANTE:
DICHIARAZIONE DI CONFORMITÀ • CONFORMITEITSVERKLARING DEKLARATION OM ÖVERENSSTÄMMELSE
EF-OVERENSSTEMMELSESERKLÆRINGVAATIMUSTENMUKAISUUSVAKUUTUS • SAMSVARSERKLÄRING
DECLARAÇAO DE CONFORMIDADE
VERSA-MATIC
Warren Rupp, Inc. A Unit of IDEX Corporation 800 North Main Street P.O. Box 1568 Mansfield, OH 44901-1568 USA
Tel: 419-526-7296 Fax: 419-526-7289
®
PUMP MODEL SERIES: E SERIES, V SERIES, VT SERIES, VSMA3, SPA15, RE SERIES AND U2 SERIES
This product complies with the following European Community Directives:
Ce produit est conforme aux directives de la Communauté européenne suivantes: Este producto cumple con las siguientes Directrices de la Comunidad Europea: Dieses produkt erfüllt die folgenden Vorschriften der Europäischen Gemeinschaft: Questo prodotto è conforme alle seguenti direttive CEE: Dir produkt voldoet aan de volgende EG-richtlijnen: Denna produkt överensstämmer med följande EU direktiv: Versa-Matic, Inc., erklærer herved som fabrikant, at ovennævnte produkt er i overensstemmelse med bestemmelserne i Direkktive: Tämä tuote täyttää seuraavien EC Direktiivien vaatimukstet: Dette produkt oppfyller kravene til følgende EC Direktiver: Este produto está de acordo com as seguintes Directivas comunitárias:
2006/42/EC
on Machinery, according
to Annex VIII
This product has used the following harmonized standards to verify conformance: EN809:1998+
Ce materiel est fabriqué selon les normes harmonisées suivantes, afin d’ en garantir la conformité: Este producto cumple con las siquientes directrices de la comunidad europa: Dieses produkt ist nach folgenden harmonisierten standards gefertigtworden, die übereinstimmung wird bestätigt: Questo prodotto ha utilizzato i seguenti standards per verificare la conformita´: De volgende geharmoniseerde normen werden gehanteerd om de conformiteit van dit produkt te garanderen: För denna produkt har följande harmoniserande standarder använts för att bekräfta överensstämmelse: Harmoniserede standarder, der er benyttet: Tässä tuotteessa on sovellettu seuraavia yhdenmukaistettuja standardeja: Dette produkt er produsert i overenstemmelse med fløgende harmoniserte standarder: Este produto utilizou os seguintes padrões harmonizados para varificar conformidade:
AUTHORIZED / APPROVED BY:
Approuve par: Aprobado por: Genehmigt von: approvato da: Goedgekeurd door: Underskrift: Valtuutettuna: Bemyndiget av: Autorizado Por:
04/19/2012 REV 07 VMQR 044FM
e40mdlCsmATEX-rev0514
ww w. ve rs am ati c. co m
Dave Roseberry Engineering Manager
A1:2009
DATE: August 10, 2011
FECHA: DATUM: DATA: DATO: PÄIVÄYS:
Model E40 Metallic • 12
Page 16
EC DECLARATION OF CONFORMITY
in accordance with ANNEX VIII of Directive 94/9/EC - Equipment for use in Potentially Explosive Atmospheres
Date of Issue: 10 May 2014
Technical File No.: 203104000-1410/MER
Quality System Registration No: ISO 9001-2000
Directive: 94/9/EC 23 March 1994 Annex VIII
Conforming Apparatus: Air-Operated Metal Double Diaphragm Pumps for Use In Potentially Explosive Atmospheres
Hazardous Location Applied: 1. II 3/2GD c T5*
T5 fl uids up to 95° C
* When pumping non-conductive fl uids the internal surfaces that contact the fl uid are restricted to Ex II 3GD c T5. The external
surfaces of the pump are still Ex II 2GD c T5.
2. I M2 c
fl uids up to 95° C
Pumps marked with equipment Category II 3/2 G (internal 3 G / external 2 G), 2D, when used with
non-conductive fl uids. The pumps are Category II 2 G when used for conductive fl uids.
Manufacture: Warren Rupp, Inc., A Unit of IDEX Corporation 800 North Main Street, P.O. Box 1568
Mans eld, OH 44901-1568
USA.
On File With: DEKRA Certi cation B.V. (0344)
Meander 1051 6825 MJ Arnhem The Netherlands
Harmonized Standards Applied: EN 13463-1:2009 Non-Electrical Equipment Potentially Explosive Atmospheres-Part 1 Basic Methods and Requirements EN 13463-5:2011 Non-Electrical Equipment for Potentially Explosive Atmospheres-Part 5 Protection by Constructional Safety
Equipments: 1. Elima-Matic Series metal pumps for II 3/2GD c T5
2. Elima-Matic Series Cast Iron or Stainless Steel pumps with Stainless Steel air center sections for I M2 c
We hereby certify that the equipment described above conforms with the protection requirements of Council Directive 94/9/EC of 23 March 1994 Annex VIII on the approximation of the laws of the Member States Concerning Equipment and Protective Systems Intended for use in Potentially Explosive Atmospheres
DATE/OF REVISION/TITLE: Dave Roseberry 29 May 2014 Engineering Manager
VM_DofC_ATEX_Metallic_V_rev0514
Loading...