Read the safety warnings and instructions in this manual
before pump installation and start-up. Failure to comply with
the recommendations stated in this manual could damage the
pump and void factory warranty.
When the pump is used for materials that tend to settle out
or solidify, the pump should be ushed after each use to
prevent damage. In freezing temperatures the pump should be
completely drained between uses.
CAUTION
Before pump operation, inspect all fasteners for loosening
caused by gasket creep. Retighten loose fasteners to prevent
leakage. Follow recommended torques stated in this manual.
Nonmetallic pumps and plastic components are not UV
stabilized. Ultraviolet radiation can damage these parts and
negatively affect material properties. Do not expose to UV light
for extended periods of time.
WARNING
Pump not designed, tested or certied to be powered by
compressed natural gas. Powering the pump with natural
gas will void the warranty.
WARNING
When used for toxic or aggressive uids, the pump should
always be ushed clean prior to disassembly.
Before maintenance or repair, shut off the compressed air line,
bleed the pressure, and disconnect the air line from the pump.
Be certain that approved eye protection and protective clothing
are worn at all times. Failure to follow these recommendations
may result in serious injury or death.
Airborne particles and loud noise hazards. Wear eye and ear
protection.
In the event of diaphragm rupture, pumped material may enter
the air end of the pump, and be discharged into the atmosphere.
If pumping a product that is hazardous or toxic, the air exhaust
must be piped to an appropriate area for safe containment.
Take action to prevent static sparking. Fire or explosion can
result, especially when handling ammable liquids. The pump,
piping, valves, containers and other miscellaneous equipment
must be properly grounded.
This pump is pressurized internally with air pressure during
operation. Make certain that all fasteners are in good condition
and are reinstalled properly during reassembly.
kg
Use safe practices when lifting
Grounding the Pump
To be fully groundable, the pumps must be ATEX Compliant. Refer to the nomenclature page for ordering information.
Optional 8 foot long (244 centimeters) Ground Strap is available for easy ground connection.
To reduce the risk of static electrical sparking, this pump must be grounded. Check the local
electrical code for detailed grounding instruction and the type of equipment required.
Refer to nomenclature page for ordering information.
WARNING
Take action to prevent static sparking.
Fire or explosion can result, especially
when handling ammable liquids. The
pump, piping, valves, containers or
Your Serial #: (ll in from pump nameplate) _____________________________________
1: PUMP SPECS
Your Model #:
(ll in from pump
nameplate)
__ __ __ __ __ __ __ __ __ __ __ __ __
Model #:
Options (if applicable)
Design Level
Construction Design
Valve Seat Material/Valve Seat O-Ring Material
Valve Ball Material
Diaphragm Series
Diaphragm Material
Non-Wetted Parts
Wetted Parts
Pump Size
Model
Model Pump Size Wetted Parts Non-Wetted Parts Diaphragm Material
E Elima-Matic 6 1/4" A Aluminum A Aluminum 1 Neoprene
U Ultra-Matic 8 3/8" C Cast Iron S Stainless Steel 2 Nitrile (Nitrile)
V V-Series 5 1/2" S Stainless Steel P Polypropylene 3 FKM (Fluorocarbon)
RE AirVantage 7 3/4" H Alloy C G Groundable Acetal 4 EPDM
1 1" P Polypropylene Z PTFE-coated Aluminum 5 PTFE
4 1-1/4" or 1-1/2" K Kynar J Nickel-plated Aluminum 6 Santoprene XL
2 2" G Groundable Acetal C Cast Iron 7 Hytrel
3 3" B Aluminum (screen mount) Q Epoxy-Coated Aluminum 9 Geolast
Y FDA Santoprene
Diaphragm Series Valve Ball Material Valve Seat/Valve Seat O-Ring Material Construction Design Miscellaneous Options
R Rugged 1 Neoprene 1 Neoprene 9 Bolted B BSP Tapered Thread
D Dome 2 Nitrile 2 Nitrile 0 Clamped CP Center Port
X Thermo-Matic 3 (FKM) Fluorocarbon 3 (FKM) Fluorocarbon ATEX ATEX Compliant
T Tef-Matic (2-piece) 4 EPDM 4 EPDM Design Level FP Food Processing
B Versa-Tuff (1-piece) 5 PTFE 5 PTFE A SP Sanitary Pump
F FUSION (one-piece 6 Santoprene XL 6 Santoprene XL C HP High Pressure
integrated plate) 7 Hytrel 7 Hytrel OE Original Elima-Matic
8 Polyurethane 8 Polyurethane F Flap Valve
9 Geolast 9 Geolast HD Horizontal Discharge
A Acetal A Aluminum w/ PTFE O-Rings 3A 3-A CertiedS Stainless Steel S Stainless Steel w/ PTFE O-Rings UL UL Listed
Y FDA Santoprene C Carbon Steel w/ PTFE O-Rings OB Oil Bottle
H Alloy C w/ PTFE O-RingsT PTFE Encapsulated Silicone O-RingsY FDA Santoprene
*More than one option may be specied for a particular pump model.
1 • Model E40 Metallic
ww w. ve rs am ati c. co m
e40mdlCsmATEX-rev0514
Materials
Material Prole:
CAUTION! Operating temperature limitations are as follows:
Conductive Acetal: Tough, impact resistant, ductile. Good
abrasion resistance and low friction surface. Generally inert, with
good chemical resistance except for strong acids and oxidizing
agents.
EPDM: Shows very good water and chemical resistance. Has
poor resistance to oils and solvents, but is fair in ketones and
alcohols.
FKM: (Fluorocarbon) Shows good resistance to a wide range
of oils and sovents; especially all aliphatic, aromatic and
halogenated hydrocarbons, acids, animal and vegetable oils.
Hot water or hot aqueous solutions (over 70°F) will attack FKM.
Hytrel®: Good on acids, bases, amines and glycols at room
temperatures only.
Neoprene: All purpose. Resistance to vegetable oils. Generally
not affected by moderate chemicals, fats, greases and many
oils and solvents. Generally attacked by strong oxidizing acids,
ketones, esters and nitro hydrocarbons and chlorinated aromatic
hydrocarbons.
Nitrile: General purpose, oil-resistant. Shows good solvent, oil,
water and hydraulic uid resistance. Should not be used with
highly polar solvents like acetone and MEK, ozone, chlorinated
hydrocarbons and nitro hydrocarbons.
Nylon: 6/6 High strength and toughness over a wide
temperature range. Moderate to good resistance to fuels, oils
and chemicals.
Operating
Temperatures:
Max.Min.
190°F
88°C
280°F
138°C
350°F
177°C
220°F
104°C
200°F
93°C
190°F
88°C
180°F
82°C
-20°F
-29°C
-40°F
-40°C
-40°F
-40°C
-20°F
-29°C
-10°F
-23°C
-10°F
-23°C
32°F
0°C
Polypropylene: A thermoplastic polymer. Moderate tensile
and ex strength. Resists stong acids and alkali. Attacked by
chlorine, fuming nitric acid and other strong oxidizing agents.
PVDF: (Polyvinylidene Fluoride) A durable uoroplastic with
excellent chemical resistance. Excellent for UV applications.
High tensile strength and impact resistance.
Santoprene®: Injection molded thermoplastic elastomer with
no fabric layer. Long mechanical ex life. Excellent abrasion
resistance.
UHMW PE: A thermoplastic that is highly resistant to a broad
range of chemicals. Exhibits outstanding abrasion and impact
resistance, along with environmental stress-cracking resistance.
Urethane: Shows good resistance to abrasives. Has poor
resistance to most solvents and oils.
Virgin PTFE: (PFA/TFE) Chemically inert, virtually impervious.
Very few chemicals are known to chemically react with PTFE;
molten alkali metals, turbulent liquid or gaseous uorine and
a few uoro-chemicals such as chlorine triuoride or oxygen
diuoride which readily liberate free uorine at elevated
temperatures.
Maximum and Minimum Temperatures are the limits for which these materials can be operated.
Temperatures coupled with pressure affect the longevity of diaphragm pump components.
Maximum life should not be expected at the extreme limits of the temperature ranges.
180°F
82°C
250°F
121°C
275°F
135°C
180°F
82°C
150°F
66°C
220°F
104°C
32°F
0°C
0°F
-18°C
-40°F
-40°C
-35°F
-37°C
32°F
0°C
-35°F
-37°C
Metals:
Alloy C: Equal to ASTM494 CW-12M-1 specication for nickel and nickel alloy.
Stainless Steel: Equal to or exceeding ASTM specication A743 CF-8M for corrosion
resistant iron chromium, iron chromium nickel and nickel based alloy castings for
general applicaitons. Commonly referred to as 316 Stainless Steel in the pump industry.
For specic applications, always consult the Chemical Resistance Chart.
1: PUMP SPECS
AFTERMARKET PARTS
RIGHT PART, RIGHT NOW
Pumper Parts is your single source for parts that
t Air-Operated Double Diaphragm (AODD) pumps
• Wilden
• ARO
• Yamada
Designed to perform equal to or greater
than original equipment manufacture.
Pumper Parts and its products are not affiliated with any of the original equipment manufacturers referenced herein. All original equipment manufacturers’ names, colors, pictures, descriptions and part numbers are used for identification
purposes only. Pumper Parts® is a registered trade name of IDEX Corporation. All other trademarks, registered trademarks and product names are the property of their respective owners. Yamada® is a registered trademark of
Yamada Corporation. ARO® is a registered trade name of Ingersoll-Rand Company. Wilden® is a registered trade name of Wilden Pump and Engineering Company, a Dover Resources Company.
®
®
®
Phone: (419) 526-7296
info@pum perparts.com
www.pumperparts.com
e40mdlCsmATEX-rev0514
ww w. ve rs am ati c. co m
Model E40 Metallic • 2