Versaclean 200H-230V, 200-230V, 1200-230V, 500H-230V, 500-230V User Manual

User Manual
A
D
B
C
FIG. 1: Front View
A
Recovery tank cover
B
Vacuum hose attachment
C
Recovery tank gravity drain and gate-type valve
D
Solution hose quick-connect
Portable Extractors
Models 200-230V, 200H-230V, 500-230V, 500H -230V, 1200-230V
VersaClean Portable Extractors provide deep, rapid cleaning of carpets, upholstery and hard surfaces. Heated models provide additional cleaning power. Lightweight, easy to use, and adjustable for a wide range of carpet types and soiling conditions, the VersaClean Extractors produce cleaner, drier carpets and surfaces. Patents: http://www.LBpatents.com
READ AND SAVE THESE INSTRUCTIONS
WARNING! Do not alter or modify your unit in any way. Use only replacement parts authorized by VersaClean. Modifications or use of unapproved parts could create a hazard and will void your warranty. Contact your authorized VersaClean distributor for assistance.
WARNING! Electric shock hazard, rotating fan hazard and hot surface hazards.
Inspect the power cord before use. If cord is
damaged, do not use. Always grasp the plug (not the cord) to unplug.
Insert three-prong plug on power cord into a
matching electrically grounded outlet. Do not use adapter. Never cut off third prong. Do not use an extension cord.
The unit must be operated on two separate
230V/50 Hz circuit protected by a Residual Current Device (RCD).
Keep motor and wiring dry.
Always unplug unit before cleaning or
servicing.
Do not attempt to repair the unit. For service,
contact your local VersaClean distributor.
for assistance with obtaining a return material authorization (RMA).
BEFORE YOU BEGIN
Warranty registration
Warranty registration procedures vary by country/market. Contact VersaClean for assistance. Registration allows us to better assist you with using, maintaining or servicing your equipment and to contact you in case we have important safety information concerning your VersaClean product. If you determine service is required, have your equipment model, serial number and original proof of purchase available and ask
07-02083A 200-230V, 200H-230V, 500-230V, 500H-230V, 1200-230V 1 VersaClean
A
D
B
G
C
F
H
E
FIG. 2: Rear View
(Detail)
A
I
J
A
Solution tank with clear hinged cover
F
Exhaust outlet – keep clear
B
Wand retention clip
G
Pressure gauge (select models)
C
Vacuum exhaust. Keep clear.
H
Pressure regulator (select models)
D
Product label and serial number
I
Pumpout coupling (select models). Keep capped when not in use.
E
Dual cords (select models)
J
Auto-Fill coupling (select models)
GROUNDING INSTRUCTIONS
This unit’s plug must be inserted into an appropri ate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
WARNING! Improper connection of the equipme n t­grounding conductor can result i n a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the outlets are properly grounded. Do not modify the plu g provided with the appliance – if the plug does no t fit the outlets, have proper outlets insta lled by a qualified electrician.
This equipment is for use on circuits with a nominal rating of no more than 230V.
Handle the unit carefully
Always operate the unit on a stable, level surface. Do not drop, throw, or place where it could fall. Rough treatment can damage the unit, and may create a hazardous condition or void the warranty.
This unit intended for household and commercial use.
CONTROLS
ON THE CONTROL PANEL (see Fig. 3)
Includes rocker-type switches control blower, solution pump, and heat (on sel ec t models). Heated units are equipped with a second power cord. The second power cord must be plugged in to a separate electric power source.
Pressure regulator (Fig. 2, F). Select models. Turn clockwise to increase solution pressure; turn counterclockwise to decrease solution pressure.
Pumpout switch (Fig. 2, E) Select models. Switch to on position to activate pumpou t.
OPERATING INSTRUCTIONS
1. Pre-mix cleaning solution with hot water in a separate container. Pour mixed solution into the solution tank of the machine.
07-02083A 200-230V, 200H-230V, 500-230V, 500H-230V, 1200-230V 2 VersaClean
FIG. 4: Solution inlet filter cleaning
Remove Unscrew
A
D
B
G
C
F
FIG. 3: Control Panel
E
Power ON/OFF
Solution pressure pump ON/OFF
Solution heater ON/OFF (select models)
Pumpout ON/OFF (select models)
IMPORTANT: Take care to control foaming in the vacuum system. Excessive foam can allow moisture, carpet fiber and other debris to be drawn through the vacuum cutoff valve and cause damage to the vacuum motors. Damage caused by moisture or debris will void the product warranty. To help reduce foaming, use a low-foam detergent. Foaming may also occur because of residues left from previous cleanings . If this happens, use a defoamer additive. Follow defoamer manufacturer instructions for proper application.
2. Connect vacuum and solution hoses to machine and attach to extraction wand or hand tool.
3. Plug power cord into a 3-pin grounded circuit. Keep cords clear of your cleaning path. IMPORTANT: Heated units have two cords and should be plugged into separate 3-p in grou nde d circuits.
4. Switch on vacuum.
5. Switch on solution pump.
6. For heated solution (Heated units only).
7. Begin cleaning. Refer to industry-approved procedures.
8. If equipped, solution pressure may be adjusted with the pressure regulator knob (Fig. 2, G). Monitor the pressure gauge to ensure pressure is adequate.
CAUTION: When the recovery tank rea ches cap a city, an automatic float valve blocks vacuum intake (see Fig. 7) and the vacuum motors will make a high pitched noise. When this occurs, switch the machine off immediately to prevent damage to the vacuum motors.
9. When cleaning is completed, rinse solution tank with clear water to ensure no detergents or rinse age nts remain in the tank.
10. Empty and rinse the waste tank thoroughly. This will help to prevent the formation of damaging deposits and reduce the growth of odor-causing bacteria.
11. Turn on vacuum motor and allow it to run for 15 minutes to help remove any moisture from the vacuum motors and assure long vacuum life.
For maintenance instructions, see “Maintenance,” p. 3.
MAINTENANCE (ALL UNITS)
WARNING: Unplug machine before servicing. Possibility of electrical shock.
WARNING: Interior components may be hot after operation. Let unit cool completely before servicing.
9/16 in. nut with wrench and lift open top.
07-02083A 200-230V, 200H-230V, 500-230V, 500H-230V, 1200-230V 3 VersaClean
filter cap and rinse
FIG. 5: Vacuum cutoff valve cleaning
FIG. 6: Solution tank strainer
Slide filter upward to remove. Rinse filter clean with water and reinstall.
DAILY OR AFTER EACH USE Clean the solution inlet filter (Fig. 4) Loosen tank
attachment screw (Fig. 1) and open unit. Remove filter cover and strainer screen (Fig. 5). Rinse strainer screen clean in warm water. Replace strainer and retighten filter cover.
Clean vacuum cutoff valve and strainer (Fig. 5).
Empty recovery tank, then open recovery tank lid. Grasp valve assembly and gently pull downward, taking care not to distort the strainer screen. Rinse assembly clean and make sure float ball moves freely inside assembly. Reinstall securely.
AS NEEDED Lubricate pressure regulator O-ring (if equipped).
Access O-ring by unscrewing and removing pressure regulator (Fig. 2, F). Lubricate w ith a suitable O-ring lubricant.
Lubricate the solution line quick-connect coupling (Fig. 1, D) with a small amount of rust-inhibiting oil such as LPS-3 or WD-40.
To maintain appearance, wipe interior and exterior surfaces with a damp cloth. For deep cleaning and a lasting, protective shine, use an aut omotive vinyl cleaner/protectant produc t.
(pumpout models only)
07-02083A 200-230V, 200H-230V, 500-230V, 500H-230V, 1200-230V 4 VersaClean
Remove oil fill cap on pressure pump
Insert suction tube of transfer pump into oil fill hole. Pump out oil to a suitable waste / recycling receptacle.
After placing approximately 8 oz. of oil into the pump, check
t.
CHANGING THE 1200-230V PRESSURE PUMP OIL
Tools required:
Manual transfer pump Clean cloths Suitable oil waste/recycling container
Verify both tanks are empty. Use a cloth to wipe out any residual moisture. Place clean cardboard or a pad behind unit to protect handle. Remove retaining nut, hinge open unit and rest on pad.
Insert suction tube of transfer pump into bottle of fresh oil and pump approximatel 8 oz. of oil into pressure pump.
the oil level with the dipstick. Level should be within the notched area on the dipstick. If necessary, add oil and recheck with the dipstick until oil is at the correct level.
When filling is complete, reinstall install oil cap, close unit and reinstall retaining nu The 1200-230V is now ready for use.
WARRANTY
Warranty information is available from your dealer or at www.VersaCleanSystems.com.
Dispose of used oil appropriately.
OPTIONS (PURCHASED SEPARATELY)
Wand and Vacuum Hose Kit (48-075): Wand, 25 ft. ¼ in. solution hose and 25 ft. 1½ in. vacuum hose
Upholstery Pro (67-019)
07-02083A 200-230V, 200H-230V, 500-230V, 500H-230V, 1200-230V 5 VersaClean
ALL MODEL S
Vacuum motor
6.6 Ametek Vac Motor
Solution / recovery tank 12 gal. | 45.4 l Recovery tank: 10 gal. | 37.9 l
Rotomolded polyethylene housing and handle; semi-pneumatic wheels.
Drain valve
Gate type
Float shut-off
Ball type
Accessories included
25 ft. of ¼ in. solution hose 25 ft. of 2 in. vacuum hose
Dimensions (H × L × W)
39.5 × 32 × 19.75 in.
100.3 × 81.2 × 50.2 cm
Model
Features
Current draw
200-230V
200 PSI
Circuit 1: 7.0 amps
200H-230V
200 PSI Heated
Circuit 1: 7.0 amps Circuit 2: 7.6 amps
500-230V
500 PSI. Adjustable high pressure pump with gauge.
Circuit 1: 8.5 amps
500H-230V
500 PSI Heated. Adjustable gauge.
Circuit 1: 8.5 amps
1200-230V
Adjustable high pressure Pumpout
Circuit 1: 6.7 am ps
FIG. 7: Gravity drain diverter
SPECIFICATIONS
Capacity
Construction
high pressure pump with
pump with gauge. Auto-fill.
Circuit 2: 7.6 amps
Circuit 2: 7.5 amps
CONTACT
VersaClean 15180 Josh Wilson Road Burlington, WA 98233 800-932-3030 www.VersaCleanSystems.com
07-02083A 200-230V, 200H-230V, 500-230V, 500H-230V, 1200-230V 6 VersaClean
Loading...