Veron Barissima User Manual

BARISSIMA
User Manual
V 1.00 / 02.2015 / English
VERON Austria
Seite 2 User Manual BARISSIMA, V 1.00, 02.2015, English
Table of Contents
1
General 4
1.1
Identification 4
1.2
Modification of Products 4
1.3
Important Information about the User Manual 4
1.4
Safety-related information 5
2
Product description 11
2.1
Important notes on the product 11
2.2
Product data (technical data) 14
2.3
Features 16
3
Initial Operation 17
3.1
Safety notes for first-time Operation 17
3.2
Positioning 17
3.3
Assembly / Installation 18
3.4
First Start-up 21
3.5
Acceptance 21
4
Operation 22
4.1
Safety - Operation 22
4.2
Setup / Settings 23
4.3
Filling of the Container 23
4.4
Switching on the milk foamer 23
4.5
Operating Menu / Display 24
4.6
Filling the milk lines 25
4.7
Obtaining milk of milk foam 25
4.8
Turning of the milk foamer 25
5
Adjustment 26
5.1
Manual Adjustment 26
5.2
Customer menu settings 26
6
Troubles, Messages and Notes 33
6.1
Troubleshooting 33
6.2
System messages 33
6.3
Error Messages 33
7
Cleaning / Care 34
7.1
Safety - Cleaning / Care 34
7.2
Detergents 34
7.3
Overview Cleaning Intervals 35
7.4
Care and Cleaning Work 35
7.5
HACCP Cleaning Concept 38
7.6
Clening Plan 39
8
Maintenence / Service 40
8.1
Introduction 40
8.2
Safety directions for Maintenance / Service 40
8.3
Maintenance Intervals 41
9
Detergents and Spare parts 41
9.1
Detergent 41
9.2
Spare parts catalog 41
9.3
Order Form 42
10
Decommissioning / Storage 43
10.1
Safety directions for Decommissioning / Storage 43
10.2
Storage Conditions 43
10.3
Decommissioning 43
Betriebsanleitung BARISSIMA, V 1.00, 02.2015, Deutsch Seite 3
10.4
Maintenance during storage 44
10.5
Commissioning after storage 44
11
Disposal 45
11.1
Safety information - Disposal 45
11.2
Packaging 45
11.3
Disassembly 45
11.4
Return to Manufacturer 45
12
Change Index 46
Seite 4 User Manual BARISSIMA, V 1.00, 02.2015, English
1 General
1.1 Identification
User Manual
BARISSIMA Language EN Edition 2015 Revision 02/2015
Product
This manual refers to the milk foamer BARISSIMA. The identification of the milk foamer can be found on the machines name plate.
You can find the exact description of the machine on the requirements, benefits and features in chapter "2 Product Description”
1.2 Modification of Products
All built-in milk foamer parts are preset and may only be changed by an authorized service technician.
There must be no modifications to the product carried out by the customer.
In case of non-compliance the warranty by the customer service or the
Manufacturer is not covered.
1.3 Important Information about the User Manual
The User Manual must always be available near the milk foamer.
All persons who work on the machine must read the User Manual
or be taught by trained staff.
The User Manual contain important information for safe operation.
The User Manual makes it easier for you to learn and use all applications of this
machine.
Compliance with the User Manual will help you to avoid dangers and unnecessary repairs and downtime.
The milk foamer will thank you for your care with increased reliability and durability.
Betriebsanleitung BARISSIMA, V 1.00, 02.2015, Deutsch Seite 5
1.4 Safety-related information
1.4.1 Symbols used in these User Manual
Warning! Safety-related information
Texts with this symbol or signal word indicate a hazard with a medium-risk, which, if not avoided, can result in death or serious injuries.
Electric Shock
Caution! Protection against personal injury
Texts with this symbol or signal word indicate a hazard with a low level of risk which, if not avoided, can result in minor or moderate injuries.
Hot Steam Hot Surface
Toxic or corrosive Substances
Crushing hazard
Important! Notes on property damage
For the milk foamer For the installation location
Always follow the user manual
Note!
Texts with this symbol or signal word contain additional important information on dealing with the milk foamer.
Seite 6 User Manual BARISSIMA, V 1.00, 02.2015, English
1.4.2 Safety
Note!
Read the instruction manual carefully. Keep the User Manual always at hand.
This manual must always be kept near the milk foamer.
All persons who work on the machine must read the user manual
or be taught by trained staff.
The installation and initial operation of the machine must be performed by an authorized service technician.
Use the machine only if it is in perfect condition.
The milk foamer may only be opened, maintained and repaired by authorized service
technicians. Otherwise, there is danger to life and equipment.
All parts in the milk foamer are calibrated and may only be changed by an authorized service technician.
The power supply and plug must be replaced by an authorized service technician only.
No changes, alterations or attempts at repair, especially using tools may be carried out on or in the appliance.
Use only replacement parts that are listed in the parts catalog.
The integrated component-tested safety devices prevent unwanted pressure and
temperature increase in the hot water boiler. If the safety valve opens, the machine must be switched off immediately at the main switch and the main shutoff valve to the drinking water supply must be closed. If there are troubles, switch off the machine and call an authorized service technician. Do not turn the machine on until the error is fixed.
The hot water and steam boiler went through a water pressure test
The operator is responsible for the regular overview of safety by an expert. Therefore,
perform an inspection and maintenance once a year by an authorized service technician.
The operator must ensure that the electrical systems and equipment are in a proper condition.
For trouble-free operation of the machine a room temperature of +10°C to +40°C and a maximum relative humidity of 80% is required.
This machine is not intended for use by persons (including Children) with reduced intellectual, sensory and physical abilities or lack of experience and knowledge, unless they are supervised by a person responsible for their safety.
Prevent access for children or contact with domestic animals, plants or insects. This also applies to the packaging material, small parts and detergents.
Keep in mind that after switching off the machine several outlet parts still may be hot.
NEVER spray into the machine with a spray. CFC and HFC free Propellants are often
highly flammable. EXPLOSION HAZARD!
During unattended shutdowns the machine must be turned off and the tap must be turned off. For water and electricity damage due to not following this instruction, any liability is rejected.
Use only original VERON cleaners and spare parts. For damages that are caused by the use of other cleaning products and spare parts any liability is rejected.
For accidents or damage caused due to non-observance of these Safety regulations neither the supplier nor the manufacturer is liable.
Betriebsanleitung BARISSIMA, V 1.00, 02.2015, Deutsch Seite 7
1.4.3 Warning Notes
Despite all precautions, every machine contains a potential safety risk when handled improper. For this reason, we have - for your own safety - summarized the hazards for you. Note these hints when operating your milk foamer to avoid injury and health hazards.
The milk foamer is state of the art and constructed under recognized safety regulations, still hazards may arise.
Operate the machine only in perfect condition and in compliance with the User Manual.
Warning!
Risk of death by electric shock!
Water or other liquids reaching the electronics of your milk foamer can lead to life­threatening electrical shocks.
Do not clean your milk foamer and the installation area with running water, steam cleaners or steam jet cleaners.
Protect the milk foamer from dampness or the influence of weather (frost, sunlight) and do not use the milk foamer outdoors.
Do not open the casing of your milk foamer.
Do not reach into the inside of your milk foamer and do not use any tools on the
machine.
Warning!
Risk of death by defects in the power cord!
Defects in the power cord can lead to life-threatening electrical shocks.
Protect the power cord from damage.
Do not rip, bend, clamp or squeeze the power cord.
Never lift or pull the machine by the power cord.
Never pull out the plug by pulling on the power cord.
Never touch cables and plugs with wet hands.
Protect the power cord from sharp edges, moisture, heat and oil.
Do not connect the machine if the power cord is damaged.
Do not attempt to repair a damaged power cable by yourself.
A damaged power cord must only be replaced by an authorized service technician.
Caution!
Possible burn or scalding hazard from hot components, steam and hot liquids!
The outlet head, as well as the outlets are very hot during operation and can cause burns at contact. Hot beverages and escaping steam can scald you.
Do not touch the outlet head, the outlets or directly adjacent Surfaces of your milk foamer.
Avoid contact with the hot steam and be careful with hot beverage.
Allow the machine to cool down before cleaning or removing or adding any
accessories.
Seite 8 User Manual BARISSIMA, V 1.00, 02.2015, English
Caution!
Possible health hazard!
If the milk unit is not cleaned properly or other food or materials that the ones intended for the machine are used, you can affect your health.
Clean the machine regularly according to the instructions in the chapter "7 Cleaning / Care ".
Use only milk in the milk system of your milk foamer.
Caution!
Possible health hazard by detergents!
Detergents are irritating and can get very hot during the cleaning process. Detergents can affect your health. Detergents can damage plastic parts and other materials such as textiles.
Avoid contact with cleaning agents.
Hold the detergents away from children.
Take in no detergents or mix them with other detergents, or other chemicals.
Wash your hands and face after cleaning your milk foamer, even if you interrupt the
cleaning.
Do not eat or drink during the cleaning process.
Make sure you have proper ventilation during the cleaning process.
Use only recommended VERON detergents.
Important!
Possible damage to sensitive mounting surfaces!
Due to leakage of hot steam or water sensitive surfaces can be damaged.
The installation and commissioning of the machine may only be carried out by an authorized service technician.
Place the milk foamer on an absolutely water-resistant and heat-resistant surface.
Make sure that the installation area is dry.
The installation surface must be level and able to bear the weight of the milk foamer.
Important!
Possible damage to property caused by damage to the water supply line!
Damage to the water supply may result in water damage to the entire working area.
Always make sure that the shut-off valve at the water supply line is closed and the main power is switched off or the power cord is unplugged at the end of work.
The milk foamer must not be left unattended when operational.
Betriebsanleitung BARISSIMA, V 1.00, 02.2015, Deutsch Seite 9
1.4.4 Obligation of the operator
The milk foamer VERON BARISSIMA is only suitable for heating and frothing milk. The milk foamer VERON BARISSIMA is designated for gastronomic use.
The intended use contains:
That you carefully read, understand and follow the User Manual.
That you pay particular attention to the safety instructions.
That you use the VERON BARISSIMA within the operating conditions that are
described in this manual.
That you are not using the milk foamer under any circumstances to heat up or put out
any other liquids than milk.
Improper use is when you use the VERON BARISSIMA differently than described in this manual.
Note!
The manufacturer or the customer service is not liable for damages if there are signs for improper use.
1.4.5 Obligations of the operator
The operator is responsible for the regular review of safety by an expert. Therefore,
perform at least an inspection and maintenance once a year by an authorized service technician.
The milk foamer must be installed so that the care and maintenance is easily
possible.
The operator must ensure that the electrical systems and equipment are in a proper
condition.
All persons who work on the machine must read the user manual or be taught by
trained staff.
Hygiene regulations must be followed.
Use only original VERON cleaners and spare parts.
The manufacturer's specifications regarding maintenance cycles and frequency of
maintenance must be followed.
1.4.6 Warranty
The buyer is entitled to the statutory warranty rights. First the vendor should always
be given the opportunity to amend within a reasonable time.
Any further claims, in particular claims for damages for consequential damages, are -
as far as legally permissible - excluded.
Defects must be reported in writing to the seller immediately.
Seite 10 User Manual BARISSIMA, V 1.00, 02.2015, English
1.4.7 No Warranty
The manufacturer accepts no liability in the cases listed below.
On any parts subject to natural wear and tear (e.g. seals, valves, motors etc.).
For defects caused by weathering, deposition of scale in the boiler, chemical,
physical, electrochemical or electrical influences, provided these are not the faults of VERON.
For faults resulting from not following the instructions on maintenance and cleaning according to the instruction manual.
For defects from the failure to use original spare parts from VERON or faulty installation by the purchaser or third parties.
For defects caused by faulty or negligent treatment.
For defects occurring due to improper or incorrect use.
For results by improper use and without consent of VERON carried out modifications or repairs undertaken by the purchaser or third parties
1.4.8 Disclaimer
VERON Austria GmbH reserves the right to change technical data, colors, Materials, and similar things or cancel the production of a particular model without prior notice and without giving any reason
The spare parts shown and described reflect in terms of Appearance, scope of delivery and dimensions the state of the art at the time of printing. Interim innovations taking place due to new technical regulations, statutory provisions and amendments in the sense of technical progress are reserved by VERON Austria GmbH.
We accept no liability for printing errors.
1.4.9 Service and Address
You have questions on how to operate your milk foamer or you need an appointment for maintenance or repair with our VERON customer service? VERON is constantly striving to provide good service!
VERON Customer Service
VERON Austria GmbH E-Mail: technik@veron-austria.com
Name and Address of the Warrantor
VERON Austria GmbH Untere Sparchen 25 6330 Kufstein, Austria
Tel.: +43 (0)5372 22496 Fax: +43 (0)5372 22496 -10 E-Mail: info@veron-austria.com
Betriebsanleitung BARISSIMA, V 1.00, 02.2015, Deutsch Seite 11
2 Product description
2.1 Important notes on the product
2.1.1 Overall view / Unit design
1
2
3
1 Touch screen 2 Product outlet 3 Drip tray
Seite 12 User Manual BARISSIMA, V 1.00, 02.2015, English
2.1.2 Intended use
This milk foamer is manufactured for commercial use.
This milk foamer is not suitable for home use.
This milk foamer is not intended for use by persons (including Children) with reduced
intellectual, sensory and physical abilities or lack of experience and knowledge, unless they are supervised by a person responsible for their safety
2.1.3 Precautions
Installation note
For trouble-free operation of the machine a room temperature of +10°C to +40°C and a maximum relative humidity of 80% is required.
The installation and initial operation of the machine must be performed by an authorized service technician.
The installation surface must be level and able to bear the weight of the milk foamer.
The milk foamer must be placed outside the direct movement of persons and
overseen by trained personnel.
The milk foamer must not be exposed to direct sunlight.
The milk foamer must not stand in the open.
When replacing the milk foamer the old hose sets may no longer be used.
The manufacturer is not liable for damages caused by improper installation.
Note!
Please refer to the detailed description in chapter "3 Initial operation".
Protection of the electronics
For maintenance or repair work a control plug under voltage must never be plugged in or out.
The manufacturer is not liable for damages caused by improper reparation.
All parts in the milk foamer are calibrated and may only be changed by an authorized
service technician.
The milk foamer must be volt-free before it is opened.
The power supply and plug must be replaced by an authorized service technician
only.
Warning!
Risk of death by defects in the power cord!
Defects in the power cord can lead to life-threatening electrical shocks.
Protect the power cord from damage.
Do not rip, bend, clamp or squeeze the power cord.
Protect the power cord from sharp edges, moisture, heat or oil.
Do not connect the machine if the power cord is damaged.
Do not attempt to repair a damaged power cable by yourself.
A damaged power cord must only be replaced by an authorized service technician.
Betriebsanleitung BARISSIMA, V 1.00, 02.2015, Deutsch Seite 13
2.1.4 EC Declaration of Conformity
Der Hersteller VERON Austria GmbH Untere Sparchen 25 6330 Kufstein, Austria Tel.: +43 (0)5372 22496
erklärt hiermit, dass folgendes Produkt
Produktbezeichnung: BARISSIMA Baujahr: 2015
allen einschlägigen Bestimmungen der Richtlinie Maschinen (2006/42/EG) entspricht. Folgende harmonisierte Normen wurden angewandt:
EN ISO 12100-1 Sicherheit von Maschinen - Grundbegriffe, allgemeine Gestaltungsleitsätze, Teil 1: Grundsätzliche
Terminologie, Methodik
EN ISO 12100-2 Sicherheit von Maschinen - Grundbegriffe, allgemeine Gestaltungsleitsätze, Teil 2: Technische
Leitsätze und Spezifikationen
Die Maschine entspricht weiterhin allen Bestimmungen der Richtlinien Elektrische Betriebsmittel
(2006/95/EG), Elektromagnetische Verträglichkeit (2004/108/EG) und Beschränkung gefährlicher Stoffe in Elektro- und Elektronikgeräten (2011/65/EU).
Folgende harmonisierte Normen wurden angewandt:
EN 60335-1 Sicherheit elektrischer Geräte für den Hausgebrauch und ähnliche Zwecke – Teil 1: Allgemeine
Anforderungen
EN 60335-2-75 Sicherheit elektrischer Geräte für den Hausgebrauch und ähnliche Zwecke – Teil 2-75: Besondere
Anforderungen für Ausgabegeräte und Warenautomaten für den gewerblichen Gebrauch
EN 55014-1 Elektromagnetische Verträglichkeit – Anforderungen an Haushaltgeräte, Elektrowerkzeuge und
ähnliche Elektrogeräte – Teil 1: Störaussendung
EN 55014-2 Elektromagnetische Verträglichkeit – Anforderungen an Haushaltgeräte, Elektrowerkzeuge und
ähnliche Elektrogeräte – Teil 2: Störfestigkeit - Produktfamiliennorm
EN 61000-3-2 Elektromagnetische Verträglichkeit (EMV) – Teil 3-2: Grenzwerte – Grenzwerte – Grenzwerte für
Oderschwingungsströme (Geräte-Eingangsstrom <= 16 A je Leiter)
EN 61000-3-3 Elektromagnetische Verträglichkeit (EMV) – Teil 3-3: Grenzwerte – Begrenzung von
Spannungsänderungen, Spannungsschwankungen und Klicker in öffentlichen Niederspannungs­Versorgungsnetzen für Geräte mit einem Bemessungsstrom <= 16 A je Leiter, die keiner Sonderanschlussbedingung unterliegen
Weitere angewandte Normen:
DIN 10531 Lebensmittelhygiene – Herstellung und Abgabe von Heißgetränken aus Heißgetränkebereitern –
Hygieneanforderungen, Migrationsprüfung
Name des Dokumentationsbevollmächtigten: Leonhard Embacher Adresse des Dokumentationsbevollmächtigten: siehe Adresse des Herstellers
Kufstein, am 04.02.2015
__________________________________ Leonhard Embacher Geschäftsführer
Seite 14 User Manual BARISSIMA, V 1.00, 02.2015, English
2.1.5 Labeling of the product
On your milk foamer a nameplate is attached. Transfer the data from your nameplate in the field below, so you have the data always ready at hand.
VERON Austria GmbH
Untere Sparchen 25 6330 Kufstein, Austria Tel.: +43 (0)5372 22496
---------------------------------------------------------------------
Typ Model BJ Serial Nr.
---------------------------------------------------------------------
Volt Hz Watt Fuse
2.2 Product data (technical data)
BARISSIMA Unit width 18 cm Unit height 55 cm Unit depth 50 cm Net weight 25 kg Boiler capacity 1,5 l Boiler input 2,6 kW
Electrical connection
220 – 240 V AC 13 A 50/60 Hz
Electrical connection
400 V AC 3x16 A 50/60 Hz
Loading...