Vernier VE10W User Manual

Page 1
Page 11 of 18
Serial Device Signal
VE10W Pin nos
Signal
D- 1 D-
D+ 2 D+
Serial Device Signal
VE10W Pin nos
Signal
R- 3 T-
R+ 4 T+
T- 1 R-
T+ 2 R+
User Manual of Serial to WiFi Converter, Model VE10W
Wiring Architecture
RS232 Wiring Diagram RS485 Wiring Diagram RS422 Wiring Diagram
Serial Device Pin nos
Signal
VE10W Pin nos
Signal
2
RX 3 TX
3
TX 2 RX
5
GND 5 GND 7 RTS 8 CTS
8
CTS 7 RTS
LED Indicators
SYS (Red)
: Power
When the Power is on, the LED in ON
LAN (Green)
: Network
When the LAN signal is detected, the LED will be ON.
TX (Red)
: Data sent
When data is sent out from the network, the LED will blink.
RX (Green)
: Data received
When data is received in the network, the LED will blink.
When you finish the steps mentioned above and the LED indicators are as shown, the converter is installed correctly. You can use the Software Setup CD to setup the IP Address. To proceed with the Advance parameter setup, you can also use a web browser (IE or Netscape) to continue the detailed settings.
Page 2
Page 22 of 18
DS Tool Software Setup DS Tool uses UDP broadcast packets to query and configure converters on the network. Insert the CD. Select “DSTool_ODM_Setup folder. Double click DSTool_ODM_Setup.exe”. When the Installing DSTool” screen pops up, double click the “Start” icon for installing.
After installation, Installation was completed successfully screen will pop up. Double click the OK” icon. Choose any of the 2 options in the next screen.
If you choose Launch DSTool Now then the Device Configuration manual screen will appear.
Page 3
Page 33 of 18
Serial to Wi-Fi Converter Configuration Broadcast
After finishing DSTool installation, launch DSTool, double click Broadcast” button. It will detect the existence converters in the network. Select the converters you wish to add and double click Add button. The table will depict the converter details such as IP address, MAC Address, Device Name and Status.
Device List
In the Device List icon, you will find all the added converters.
Double click on the device will allow you to configure other converter settings.
Page 4
Page 44 of 18
General After listing of device IP in “Device List” item, you can click the IP as shown in the table.
General information as
Model”, “IP Address”, and MAC Address”, “Firmware
Version” “Device Name / Location and device working status etc appear. You can configure some parameters and modify device name and location
Security Serial to Wi-Fi converter’s Security includes Access IP, Mask list and Administration security.
The Access IP Table specifies the IP address and Subnet that can access the device. The access is based on IP and Mask combination. If the access is open to all hosts, Do NOT enable this function. You can assign a password for Administrator’s Management & Security.
After modifying configuration, be sure to Save the changes by using Apply Only or Apply and Save”.
Page 5
Page 55 of 18
Networking
Wireless
Notification
Serial to Wi-Fi converter can support both type of IP such as Static IP or DHCP/BootP IP configuration. After modifying configuration click
the
icon
of Apply Only or Apply and Save”
for finishing IP configuration.
You can use the wireless item for configuring Serial to Wi-Fi Converters Wi-Fi parameters. SSID Scan is for searching the available wireless access point and to select your AP device. Wireless Encryption is for setup parameters as encryption type and key. Save the changes by using Apply Only or “Apply and Save”.
Serial to Wi-Fi converter can support 3 ways of event notification e.g “SNMP Trap”, Email Notification
and
Syslog Notification.
Page 6
Page 66 of 18
Management In addition to DSTool, Serial to Wi-Fi Converter can also be managed by Web and Telnet consoles as well as by SNMP.
The Web and Telnet functions are enabled as default. To enable or disable the management consoles, you can use the Configuration and Management” of DSTool for configuring. To enable SNMP trap support, you have to check the SNMP Management Enable device and
specify SNMP settings including Community, Location, Contact, and Trap Server IP. Upgrade Firmware
To update firmware of the device, save the firmware file in your host PC. Go to Configuration”, and Update Firmware”. Specify the file location by Browsing and continue operation by Update. The device will reboot after firmware updating.
Note: All parameters will restore to default after the firmware update, except for the device IP address.
Save/Load After finishing setup, click “Apply and Save” button. The changes are valid after rebooting the device.
Load default” is all parameters changes to factory’s default except network setting. Reboot Device” is for rebooting device and needs to broadcast again to search the device.
Import” is for retrieving saved configuration file in to the current device. Export” is saving the current parameters onto a file and export to a current host for saving.
Page 7
Page 77 of 18
Port
Port Configurations is for configuring Serial parameters.
delimiters are received the data will not be transmitted successfully.
Port Alias : Remarks for the port. Baud rate : From 110bps to 460.8kbps Parity : No, Even, Odd, Mark, Space Data Bits : 5, 6, 7, 8 Stop Bits: 1, 2 (1.5) Flow Control : None, XON/XOFF, RTS/CTS, DTR/DSR Interface : RS232 Performance : Throughput” : guarantees highest transmission speed or Latency : guarantees shortest response time.
Delimiter Settings For advanced data packing options, you can specify delimiters for Serial to Ethernet and / or Ethernet to Serial communications. You can define 4 delimiters (00~FF, HEX) for each way and until the
Flush Ethernet to Serial Data Buffer After is time for which data will be stored before getting transmitted between Ethernet and Serial. Force TX interval time” is for specifying the timeout when no data has been transmitted and the timeout is reached or TX buffer is full (4K Bytes), the queued data will be sent. If you want to disable and the parameter is setting 0”. (factory default)
Service Mode : UDP Mode When device is configured as TCP Server, it gives the connected serial device a unique IP : Port address on a TCP/IP network that it can be accessed by other host on the network. Device as TCP Server waits passively to be contacted by the host computer, allowing the host computer to establish a connection and get data from the serial device.
Page 8
Page 88 of 18
This operation mode supports up to 5 simultaneous connections, so that multiple hosts can collect data from the same serial device at the same time.
Service Mode : Virtual COM Mode This option enables the Serial Port in the Converter to act and be controlled as PCs COM port for Windows. One PC can have as many as COM ports on the network without the limitation of PC’s physical slots. The Virtual COM ports on the network can also be shared by multiple hosts.
Service Mode : TCP Client Mode When Serial to Wi-Fi converter is configured as TCP Client, it allows the connected serial device to initiate the TCP connection to remote host software when needed. When connected, the data is transmitted bi-directionally and till the data transmission is finished, the TCP connection will be closed by TCP Client. The connect-on­demand TCP Client operation helps the host computer to manage high number of remote devices that exceeds the maximum simultaneous TCP connections allowed. Serial to Wi-Fi converter supports up to 5 simultaneous TCP Client connections for redundant system considerations
Notification Port status can be notified to administrator by email, SNMP trap, or System Log. Several events of notification include : DCD changed: When DCD (Data Carrier Detect) signal changes, indicating the modem connection status has changed, the event will be triggered. RI changed: When RI (Ring Indicator) signal changes, indicating the incoming of a call, the event will be triggered. DSR changed: When DSR (Data Set Ready) signal changes, indicating that the data communication equipment is powered off, the event will be triggered. CTS changed: When CTS (Clear To Send) signal changes, indicating that the transmission between computer and DCE can proceed. Port connected: In TCP Server Mode, when the device accepts an incoming TCP connection, this event will be trigger. In TCP Client Mode, when the device has connected to the remote host, this event will be trigger. In Virtual COM Mode, when Virtual COM is ready to use, this event will be trigger. Port disconnected: In TCP Server/Client Mode, when the device looses the TCP link, this event will be trigger. In Virtual COM Mode, When Virtual COM is not available, this event will be trigger. To enable activate the notification, specify the event type and the notification methods. The details of SNMP trap Server, Email SMTP server, or Log server IP should be configured first properly in device Configuration Management”.
VCOM List You can monitor the COM port status from the VCOM function. The monitored items can also be defined by the Select Monitor Items icon. The COM ports must be configured first before monitoring the status.
DSTool offers 5 Setup Wizards to help you manage Serial Wi-Fi Converter devices as a group.
Page 9
Page 99 of 18
Virtual COM Wizard
Select the available ports of Serial Wi-Fi Converters on the network.
DSTool offers one of the easiest way to add serial COM ports over the network by the Virtual COM Wizard. Serial Wi-Fi Converter COM port driver is installed when you install DSTool. Select the Virtual COM Wizard from Setup Wizard. There are only 3 steps to follow up.
Continue by configuring the Serial settings of the Serial ports. In Performance mode, there are Throughput” mode and Latency mode. In Throughput mode, the throughput is high. In Latency mode, the response time is low.
Page 10
Page 1010 of
Specify the Virtual COM port range and continue the operation by checking the COM port table Serial Tunnel Wizard
The Serial Tunnel Wizard gives you the option to transparently pair two devices over the network.
Select the devices that should be paired and move the devices into IP1 and IP2.
After configuring the serial
setting
of
the ports, the serial tunnel will be built by assigning one port as the TCP Server mode and the other as the TCP Client mode.
Page 11
Page 1111 of
Group IP Wizard
When you have more than one device to configure, use Group IP wizard to configure all IP addresses of the devices remotely.
Select Group IP Wizard after opening DSTool, or use Broadcast and find more than one Converters on the network and double click the button of Click here” at right side lower corner.
Search the devices in local network (i.e. same subnet), or search by an IP range. Select the devices
Select the devices for group IP configuration and define the IP addresses range or by DHCP.
Page 12
Page 1212 of
Group Setup Wizard
Click NEXT to confirm the setup and the IP configuration is finished, you will see the IP addresses for the devices
Group Setup Wizard can help you to copy the configuration of one device to other converters. You can select the items to be copied. Go to Setup Wizard”, Group Setup Wizard”, and choose “Next” to continue.
Select device model as “Serial Server DS-11­W”.
Page 13
Page 1313 of
Select the Source device for the configuration and Destination devices.
Click NEXT to confirm and finish the wizard.
Page 14
Page 1414 of
Group Firmware Wizard
To update firmware for a group of devices can be as easy as 4 steps of Group Firmware Wizard
Select the device model as Serial to Wi-Fi Converter DS-11­W, and select available converters on the network for the upgrade
Specify the firmware image and select NEXT. Confirm the firmware upgrade and continue operation. DSTool will upgrade firmware of the converter and reboot again to finish
Page 15
Page 1515 of
IP Collection Dynamic DHCP IP settings find the changing IP addresses.
System Log
DSTool supports auto IP reporting function to report the current IP address of the Serial to Wi-Fi converter units to administrator. To enable the function, check Auto IP Report” in Configuration”, General”. Specify the host that the device should report IP to, or define current host as the report host. Be sure to define the Report Interval time. Zero means disabled Go to the IP Collection function of the main menu and find the converters auto IP report list
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
You can use a calendar at the button of System Log screen for searching the history data of log massages.
Page 16
Page 1616 of
Web Console Configuration Here you can verify the connections & settings. Connect a PC to the Converter. The operating system can be Windows 95, 98, ME, XP, 2000. The Hyper Terminal” utility should be installed on your PC (see Figure 4.1). Connect the RS232 port of the Converter to the PC COM port & the Ethernet ( RJ45 ) port of the Converter to the PC’s LAN port.
Hyper Terminal for TCP/IP WinSock Initiate a Hyper Terminal from the Start Menu in Windows (see Figure 4.1), give a terminal name, choose an icon, and press “OK” button (see Figure 4.2).
Figure 4.1 Figure 4.2
Select TCP/IP (Winsock) option at the Connect using:” field (see Figure 4.3)
Figure 4.3 Figure 4.4
After “OK” button is pressed, Figure 4.4 appears. Enter the converter’s IP address (e.g. 192.168.0.10) at the Host address:” field and the Socket port number set for the Serial Port 1 at the Port number:” field (e.g 4660). (The Socket type of the Serial Port 1 should be TCP Server.)
Page 17
Page 1717 of
After “OK” button is pressed, Figure 4.5 appears. If the Hyper Terminal connects with the converter successfully, the time clock at the left lower corner Connected hh:mm:ss will start counting.
Figure 4.5
Hyper Terminal for COM Port Initiate another Hyper Terminal as a COM Port Terminal (in Figure 4.3, select COM 1 or other COM port instead of TCP/IP (Winsock)). Set the COM port Properties to be the same as those set for the Serial Port of the converter.
Figure 4.6
Data Transmission When all steps described above are finished, type any characters on the COM Port Terminal and check if the typed characters are also displayed on the TCP/IP Winsock Terminal. Alternatively, check if the characters typed on the TCP/IP Winsock Terminal are also displayed on the COM Port Terminal. If yes, then all settings are correct and the converter can operate properly.
Page 18
Page 1818 of
Pin outs
RS-232 Pin Assignment
The pin assignment scheme for a 9-pin male connector on a DTE is given below.
PIN 1 : DCD PIN 2 : RXD PIN 3 : TXD PIN 4 : DTR PIN 5 : GND PIN 6 : DSR PIN 7 : RTS PIN 8 : CTS PIN 9 : DC 5V
RS-422 Pin Assignment The pin assignment scheme for a 4-pin RS-422 is given below.
PIN 1 : R­PIN 2 : R+
1 2 3 4
PIN 3 : T­PIN 4 : T+
Loading...