Installation and Operation Instructions for Vent-Free Gas Log Sets*
Models UVL18RN, UVL18MN, UVL24RN, UVL24MN, UVL30RN, UVL30MN (Natural Gas)
W A R N I N G
If the information in this manual is not followed exactly, a fire or explosion may result, causing property damage, injury, or loss of life.
Do not store or use gasoline or other
flammable vapors and liquids in the vicin­ity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Immediately call your gas supplier from
a neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier,
call the fire department.
INSTALLER PLEASE NOTE:
DO NOT begin installation of this gas logset until all instructions have been read and understood.
Models UVL18RP, UVL18MP, UVL24RP, UVL24MP, UVL30RP, UVL30MP (Propane)
ATTENTION
Installation and service must be per­formed by a qualified agency, individual, firm, corporation, or company, experi­enced in the installation, repair, and servicing of this type of gas appliance. Do not modify, alter or tamper with any part of this heater, control, or logs.
This appliance may be installed in an aftermarket, permanently located, manu­factured (mobile) home, where not prohib­ited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
CARBON MONOXIDE POISONING MAY LEAD TO DEATH.
When used without fresh air, vent-free log sets may give off carbon monoxide, an odorless, poisonous gas. Some people - pregnant women, people with heart or lung disease, anemia, or persons under the influence of
alcohol, and persons at high altitudes are more affected by carbon monoxide than others. Early signs of carbon monoxide poisoning resemble the flu - headache, dizziness, and/or nausea. If you have these
signs, the heater may not be installed or working properly. GET FRESH AIR AT ONCE! Have the heater serviced before using it again.
*These logsets are not for exterior use.
I
S
G
E
N
D
Unvented Heaters, and Z21.60a-2003; CSA 2.26a-2003
Decorative Gas Appliances for Installation in
C
E
D
R
E
I
T
I
F
SAVE THIS MANUAL FOR FUTURE REFERENCE.
W A R N I N G
Tested and listed to ANSI Z21.11.2a-2003,
Solid-Fuel Burning Fireplaces.
CERTIFIED
7412957 10/04 Rev. 11
Page 2
General Information
In order to assure a safe and effective installa­tion, only a qualified service person who is familiar with the building codes and installation techniques appropriate to your area may install and service this appliance.
The Logsets have been designed and tested to operate safely when installed according to the installation instructions contained in this manual. Read all instructions before starting the installation.
The vent-free gas logset must be installed only in a
fireplace constructed of noncombustible material.
These logsets are not for exterior use.
This appliance is for supplemental heating only. It should
not be used as the primary heat source for a dwelling.
The logset should be inspected before use and at least
annually thereafter. More frequent cleaning may be necessary due to excessive lint from carpeting or bedding material.
In the United States, the installation and operation must
conform to local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, latest edition, CSA-B149.1 Installation Code, and with the National Electrical Code, ANSI/NFPA70 (latest edition). State or local codes may only allow operation of this appliance in a vented configuratio. Check your state or local codes. In Canada, check local province for proper use or CSA-B149. Refer to pages 7 and 8 for installation details.
The gas logset and its individual shutoff valve must be
disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 p.s.i.g. (3.5 kPa.) The gas logset must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 p.s.i.g. (3.5 kPa.)
Do not, under any circumstances, burn solid fuel (wood,
paper, coal) in the fireplace where you have installed your logset. Do not use it for cooking. Put nothing on top of the logs.
The logset must be compatible with its fuel. Natural gas
requires different hardware than propane. Never attempt to use natural gas with a propane logset or vice versa.
For a propane burning logset, the supply tank must
include a high to low gas pressure regulator. The tank must be outdoors. Do not, under any circumstances, locate supply tanks inside any structure.
The fireplace must include a screen made of chain
mesh or a similar material. You must keep the screen closed at all times during the operation of the logset; it will protect you in the event of an explosion.
WARNING: If the fireplace contains glass doors, they
must remain open at all times during the operation of the logset, allowing combustion air to circulate.
In order to avoid any possible gas leaks, apply pipe joint
compound to all non-flared, threaded connections involved in this installation. For propane, the joint compound must be resistant to the corrosive action of propane.
To check for leaks, always use a soapy water solution or
a sniffer. Never test by using an open flame.
The area around the gas logset must be free of all
combustible materials, especially gasoline or other highly flammable, vapor producing liquids.
Due to high temperatures, locate this logset away from
both high traffic areas and furniture and draperies.
Children and adults alike should be aware of the high
surface temperatures; to avoid the risk of burns or ignition of clothing they should stay away.
Do not touch any part of the logset other than the
controls while it is operating or immediately after you turn it off.
Supervise young children and pets carefully when they
are in the room where the logset is operating.
Do not place clothing or other flammable material on or
near the logset.
Make sure that any safety screen or guard, removed
during servicing, has been replaced before you use the logset.
Do not, under any circumstances, install the logset in
any bedroom, bathroom, other small, enclosed room, mobile home or recreational vehicle.
Do not install the logset in a drafty area or use it with any
after-market blower system that may cause drafting and consequently alter the flame pattern.
It is imperative that you keep clear all burner areas,
control compartments and passageways for circulating air.
Do not move the logset in any way that might dislodge
the logs from their fixed positions. If you bump the logset check to see if you have dislodged anything.
Provide adequate clearances around air openings into
the combustion chamber and adequate accessibility clearance for servicing and proper operation. NEVER obstruct the front opening of the fireplace.
Avoid propane tank dropping below 25% full. This will
help keep soot from occurring.
WARNING
This appliance is for installation in a solid-fuel burning masonry fireplace with a working flue, a U.L.-127 Listed manufactured solid-fuel burning fireplace, in any CFM Specialty Home Products ventless firebox or in any listed ventless firebox enclosure certified to I.A.S.
U.S. requirements 2-97.
NOTICE
This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to pages 5 and 6.
This appliance operates as an unvented domestic room heater when fitted to a masonry or factory-built wood-burning fireplace with the flue damper closed, or as a decorative appliance when the flue damper is fully open. It must not be used for any other purpose and must be fitted in a masonry or factory-built fireplace or ventless firebox enclosure.
22
UVL Series
Page 3
Installation Requirements
The fireplace must meet the minimum dimensions listed below. (Fig. 1) Do not install the logset if the fireplace does not meet these minimums.
Min. Fireplace Dimensions
AB C D
Logset Gas Front Rear Overall Overall Pressure (w.c.) Manifold Min. Input Max. Input
Width Width Depth Height Min. Max. Pressure BTU/hr BTU/hr 18” UVL18RN 18” UVL18MN 15,000 24,000 24” UVL24RN 24” UVL24MN 18,000 35,000 30” UVL30RN 30” UVL30MN 28,500 39,000 18” UVL18RP 18” UVL18MP 10.0” 17,000 24,000 24” UVL24RP 24” UVL24MP 10.0” 18,000 35,000 30” UVL30RP 30” UVL30MP 10.0” 29,000 39,000
Natural 20¹⁄₂”18¹⁄₂”13¹⁄₂” 18” 5.5” 14.0” 3.5”
Propane 20¹⁄₂”18¹⁄₂”13¹⁄₂” 18” 11.0” 14.0”
20¹⁄₂ 17” 13¹⁄₂ 18” 5.5” 14.0” 3.5”
25¹⁄₂ 23” 13¹⁄₂ 18” 5.5” 14.0” 3.5”
20¹⁄₂ 17” 13¹⁄₂ 18” 11.0” 14.0”
25¹⁄₂ 23” 13¹⁄₂ 18” 11.0” 14.0”
Inlet Supply
17,000 24,000
24,500 35,000
25,000 39,000
11.0” 18,000 24,000
11.0” 26,000 35,000
11.0” 29,500 39,000
D
B
C
A
A. Front Width B. Rear Width C. Depth D. Height
Fig. 1 Minimum fireplace dimensions.
FD370-2
Pressure Test Points
UVL-R Series:
captured screw-type pressure test point, therefore it is not necessary to provide a 1/8" test point upstream of the control.
UVL-M Series:
with a captured screw type inlet and manifold pressure test point on the right side of the valve.
The gas control is equipped with a
The gas valve control is equipped
Odor During Operation
Neither natural gas nor propane gas give off an odor when burned. The nature of a vent free combustion system, however, is such that odors may
occasionally be produced during heater operation when impurities exist in the immediate area. Cleaning solutions, paint, solvents, cigarette smoke, candles, adhesives, new carpet or textiles, etc., all can create fumes. These fumes may mix with combustion air and can create odor. Such odors will disappear over time, however, the condition can be alleviated by opening a window or otherwise providing additional ventilation to the area.
High Elevations
Input ratings are shown in BTU per hour and are certified without deration from elevations up to 4,500 feet (1,370m) above sea level.
Nuisance outages may occur at altitudes above 4,500 feet (1,370m) if dirt, dust, lint and/or cobwebs are allowed to accumulate on burner and/or ODS pilot. Monthly inspection and cleaning is recommended for altitudes above 4,500 feet (1,370m)
For elevations above 4,500 feet (1,370m) in USA, installations must be in accordance with the current ANSI Z223.1/NFPA 54 and/or local codes having jurisdiction.
In Canada, please consult provincial and/or local authorities having jurisdiction for installations at elevations above 4,500 feet (1,370m)
UVL Series
3
Page 4
Planning
Planning the installation is an important first step. It will save time and money later in the actual installation. In planning the installation, consider:
Where the heater will be located.
All components needed to complete the installation.
DO NOT use this heater in sleeping quarters, mobile
homes, or in recreational vehicles.
Installation and repair should be done by a qualified
service person.
DO NOT use this heater if any part has been under
water. Immediately call a qualified technician to inspect the appliance and replace any part of the control system and any gas control which has been under water.
When used as an unvented heater, always ensure there
is adequate ventilation from the room where the appliance is operating. This appliance is equipped with an ODS (oxygen depletion sensor) pilot light safety system designed to shut off the appliance if enough fresh air is not available.
THIS APPLIANCE MUST NOT BE USED WITH GLASS DOORS IN A CLOSED POSITION .
Keep the burner and control compartment clean. See installation and operating instructions supplied with the heater.
WARNING: During manufacturing, fabricating and shipping, various components of this appliance are treated with certain oils, films or bonding agents. These chemicals are not harmful, but may produce annoying smoke and smells as they are burned off during the initial operation of the appliance, possibly causing headaches or eye or lung irritation. This is a normal and temporary occurrence. The initial break-in operation should last 2-3 hours with the burner at its highest setting. Provide maximum ventilation by opening windows, doors and the chimney flue to allow odors to dissipate. Any odors remaining after this initial break-in will be slight and will disappear with continued use.
This appliance operates as an unvented domestic room heater when fitted to a masonry or factory-built wood­burning fireplace with the flue damper closed, or as a decorative appliance when the flue damper is fully open. It must not be used for any other purpose and must be fitted in a masonry or factory-built fireplace or ventless firebox enclosure.
State, provincial or local codes may only allow operation of this appliance in a vented configuration. Check your state or local codes. If unvented room heaters are not permitted, the fireplace vent damper must be locked at the minimum vent area required by local codes or by the National Fuel Gas Code (ANSI Z223.1/NFPA 54, latest edition).
When installed as a Decorative Gas Appliance for installation in a solid-fuel burning fireplace, a mini­mum permanent free opening of 29 square inches must be maintained with a fixed damper stop provided with the appliance. Minimum flue size for this appli­ance is 29 square inches.
Proposition 65 Warning: Fuels used in gas,
woodburning or oil fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm. California Health & Safety Code Sec. 25249.6
Installation Precautions
1. This vent-free gas appliance and its components have been tested and will operate safely when installed in accordance with this Installation Manual. Read all instructions before starting the installation, and follow these instructions carefully during installation to maximize the appliance's benefit and safety. Failure to follow them will void your warranty and may present a fire hazard.
2. After opening the carton, refer to
Parts
on Page 17 and 18, and remove the various
Replacement
parts. Report to your dealer if any parts were damaged in
shipment.
• CFM Specialty Home Products warranty will be voided by, and CFM Specialty Home Products disclaims any responsibility for, the following actions:
• Installation of any damaged appliance.
• Modification of the appliance.
• Installation other than as instructed by CFM Specialty Home Products.
• Improper positioning of the gas logs.
• Installation and/or use of any component part or accessory not manufactured or approved by CFM Specialty Home Prod­ucts, not withstanding any independent testing laboratory or other third-party approval of such component part or acces­sory.
Any such action may create a possible fire hazard.
Consult your local building codes.
This heater shall not be installed in a confined space unless provisions are made for adequate combustion and ventilation air.
WARNING!
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refe to this manual for assistance or additional information, consult a qualified installer, service agency or the gas supplier.
44
UVL Series
Page 5
Installation Requirements
Fresh Air Requirements for
Combustion and Ventilation
WARNING
This heater must have fresh air for proper operation. If it does not, poor fuel combustion could result. Read the following instructions to ensure proper fresh air supply for this and other fuel-burning appliances in your home.
Modern construction standards have resulted in homes that are highly energy-efficient and that allow little heat loss. Your home needs to breathe, however, and all fuel-burning appliances need fresh air to function properly and safely. Exhaust fans, clothes dryers, fireplaces, and other fuel burning appliances all use the air inside the building. If the available fresh air supply is insufficient to meet the demands of these appliances, problems can result.
The vent-free logsets have specific fresh air require­ments. You must determine that these requirements will be met within the space where the appliance will be installed. The following information will help you ensure that adequate fresh air is available for the heater to function properly.
Provide for Adequate Ventilation
Any space within a home can be classified in these categories:
1) Unusually tight construction
2) Confined space
3) Unconfined space. First, determine which classification defines the intended installation space.
Unusually Tight Construction
You must provide additional fresh air if the space falls into this classification.
struction
a. Walls and ceilings exposed to the outside atmo­sphere have a continuous water vapor barrier with a rating of one perm or less, with openings gasketed or sealed,
b. weather stripping has been added on openable windows and doors
c. caulking or sealants are applied to areas such as joints around windows and door frames, between sole plates and floors, between wall and ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at all other openings.
is defined as construction wherein:
and
and
Unusually Tight Con-
If your home meets all of the above criteria, you must provide additional fresh air for the appliance as detailed on Page 6.
If your home does not meet the above criteria, follow the procedure below.
Determine If You Have a Confined or
Unconfined Space
Use the following formula to determine if you have a confined or unconfined space. Space is defined as the room in which you will install the heater, plus any adjoining rooms with doorless passageways or ventilation grilles between the rooms. The National Fuel Gas Code defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 BTU per hour input rating (4.8m rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 BTU per hour (4.8m3 per Kw) of the aggregate input rating of all appliances installed in that space. Rooms communi­cating directly with the space in which the appliances are installed, through openings not furnished with doors, are considered a part of the unconfined space.
1. Determine the volume of space (length x width x height). Include adjoining rooms connected by doorless passageways or ventilating grilles.
Example:
of 1728 cubic feet. An adjoining open kitchen that is 10’ x 12’ x 8’ has a volume of 960 cubic feet. An adjoining open dining room is 12’ x 12’ x 8’ with a volume of 1152 cubic feet. The total volume is 3840 cubic feet.
2. Divide the volume of space by 50 cubic feet. The result is the maximum BTU/hour the space can support.
Example:
76,800 BTU/hour.
3. Add the BTU/hour ratings of all fuel-burning appliances installed in the same space, including the following:
Gas Water Heater Gas Furnace Gas Fireplace Logs Vent-free Gas Heater Vented Gas Heater* Other Gas Appliances*
* Do not include Direct-vent appliances as these use outdoor air for combustion and vent to the outdoors.
3
per Kw) of the aggregate (total) input
A room that is 18’ x 12’ x 8’ has a volume
3840 cubic feet divided by 50 = 76.8 or
UVL Series
5
Page 6
Example:
Gas Range 55,000 BTU/hour Vent-Free LogSet +
25,000 BTU/hour
Total 80,000 BTU/hour
4. Compare the maximum BTU/hour rating the space can support with the total BTU/hour used by the appliances.
Example: 76,800 BTU/hour the space can support
80,000 BTU/hour used by appliances
In this example, the maximum BTU/hour that the space can support is less than the total used by the appliances. The space is considered to be
Confined Space.
Additional air must be provided to meet the require­ments on the vent-free gas log set.
The installation and the provisions for combustion and ventilation air must conform with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the CSA­B149.1 Installation Code (Series).
A confined space may be ventilated in two ways: A. Open up or provide at least two ventilating grilles to
an adjoining unconfined space. (Fig. 2) Each of the two grilles must provide an opening of at
least 50 square inches, with all opening dimensions being at least 3”. One grille must be within 12” of the ceiling; the other within 12” of the floor. (If the total exceeds 100,000 BTU/hour, additional grilles will be needed.)
B. Vent the room directly to the outdoors. (Provide one square inch of opening for each 4,000 BTU/hr.)
For further information on ventilation guidelines and sizing specifications, follow the National Fuel Gas Code/NFPA 54/ANSI Z223.1/NFPA 54, Section 5.3.
If the total BTU/hour used by the appliances is less than the maximum BTU/hr the space can support, the room meets the
Unconfined Space
criteria and
no further ventilation is needed.
WARNING
This heater shall not be installed in a confined space or unusually tight construciton unless provisions are made for adequate combustion and ventilation air.
WARNING
If the area in which the heater may be operated is smaller than that defined as an unconfined space, or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.1/ NFPA 54, 1992, Sections 5.3, or applicable codes.
WARNING: Before installing the gas log set in a
solid-fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, and loose paint by a qualified chimney cleaner.
OPTION 1 ­Vents to Adjoining Room
Fig. 2 Ventilation options for confined spaces.
OPTION 3 ­Vents to Adjoining Room
OPTION 2 ­Remove Door to Adjoining Room
12”
12”
VO370-2
66
UVL Series
Page 7
Installation Instructions
WARNING
Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns.
WARNING: Do not use a blower insert, heat exchanger insert, or other accessory not approved for use with this gas logset.
DO NOT burn solid fuels in a fireplace where an unvented gas room heater or logset is installed.
Any outside air ducts and/or ashdumps in the fireplace must be permanently closed at time of appliance installation.
Preparing the Fireplace
Gas Line Preparation
Before connecting the appliance, turn off all gas appliances. Close the main gas valve at the gas meter or appliances. Close the main gas valve at the gas meter or LP tank. Make certain there is good ventilation where the installation will be made. Installation should comply with all applicable building codes and ANSI Z223.1/NFPA 54, latest edition, or CSA B-149.1. Use LP gas-resistant pipe compound to seal threaded joints.
Installation to Existing Gas Line
There should be a manual ON/OFF valve within easy reach of the appliance. If not, before installation of the appliance make certain a valve is installed. There may be a second valve on the line close to the point where the fireplace line branches off the main gas supply line. During installation, make certain this valve is OFF.
Manufactured Fireplace Preparation
Refer to the manufacturer’s fireplace installation manual for the specific method of running the gas line into the fireplace. The following method is typical of most manufactured fireplaces.
Insert a 1/2” gas pipe through the gas line tube pro­vided by the manufacturer, from outside the fireplace, as marked by the manufacturer. An ON/OFF valve should be placed within easy reach of the appliance. After the gas supply is installed, reinstall the insulation removed from the gas line tube, and pack it around the pipe, to prevent cold air entry and to protect the gas line. (Fig. 3)
NOTE: The gas pipe should not come into contact with any wood structure until it has reached a point at least one (1) inch away from the fireplace side. (Fig. 3)
Do not install this appliance in bedrooms or bathrooms.
WARNING: Any change to this heater or its controls can be dangerous.
Hole in Outer Casing
Ceramic Knockout
Gas Access
Holes
Electrical Access
Fig. 3 Gas line installation - factory built fireplace.
Outside Air Access
1”
Gas Supply Line
Repack Insulation
760
Masonry Fireplace Installation
Preparation
A 1/2 inch gas supply line must be supplied to the firebox. In most cases, this will require drilling a gas line access hole through the masonry wall. The gas supply line should then be sealed in the access hole with mortar. The gas supply line should also have a valve within easy reach of the appliance. Use only 1/2” rigid pipe or approved 3/8” copper tubing. (Do not use cast-iron pipe).
Clean the fireplace and chimney (if used) of any ashes, soot, creosote, or obstruction. This will minimize any smell from the fireplace. We recom­mend cleaning by a chimney sweep.
Flue Damper Preparation
The vented fireplace damper should be fully opened when operating the appliance as a vented log set. A damper stop clamp with set screw is provided as a means to prevent full closure of the fireplace damper blade. The clamp is designed to prevent accidental closure of the damper when in use. (Fig. 4) (If the damper stop cannot be installed, the installer should install a permanent damper stop that will keep the damper open a minimum of 1¹⁄₂”).
UVL Series
7
Page 8
Damper Stop Installation
When installing a decorative gas appliance in a fireplace, some local codes require a damper stop be added so the damper will not close completely. The CFM Corporation damper stop is designed so the damper can be locked in the closed position, and still allow a vent for the pilot gasses.
This damper stop is designed to work on all CFM Specialty Home Products BR, BC, SR, SC, TF and TL series fireplaces.
Installation Instructions
1. Open damper. The damper must be open to
attach the damper stop.
2. Locate the damper locking bracket. From inside
the fireplace locate the damper locking bracket on the left side of the combustion dome. (Fig. 4)
3. Align the two slots on either side of the cutout on
the damper stop with the two small holes on the angled portion of the damper locking bracket. Attach the damper stop with the screws provided. (Fig. 5)
NOTE: Some of the early units may not have the holes in the end of the damper locking bracket. If this is the case use the damper stop as a template to drill two (2) 1/8” holes in the damper locking bracket to mount the damper stop.
Damper Locking Bracket
Attachment Screws (2)
Damper Stop
Fig. 5 Attach damper stop.
Damper Stop
DP101
Damper Stop
Damper Locking Bracket
Fig. 4 Locate damper locking bracket.
DP100
Typical Man ufactured
Fireplace
Fig. 6 Damper stop placement.
Typical Masonry
Fireplace
DP105
88
UVL Series
Page 9
7A
Front View
7B
Without Hood
7C
With Hood
3¹⁄₂ Min.
Top View
Finished Wall Material
Firebox
11”
Fig. 7 Mantel clearances.
42”
3¹⁄₂Min.
Noncombustible Facing Material
Mantel Trim
Noncombustible Facing Material
3¹⁄₂
762
763
Noncom­bustible Material
Stand-off
Front Edge of Grate
8”
Flat Mantel
Stand-off
38¹⁄₂
20”
4”
3”
764
4”
Seal with Noncom­bustible Material
Shelf
8”
12”
7¹⁄₂
4” Hood
765
Burner Assembly Location
Centrally locate the unit in the fireplace, far enough back into the firebox to accomplish adequate draft (if use as a vented appliance is planned). Ensure that the front grate feet sit inside the front edge of the fireplace a minimum of 3”. (Fig. 7B)
Clearances
(Refer to Fig. 7, Page 9)
To ensure the safe installation into a masonry or factory-built fireplace, carefully observe the following instructions:
1. Sidewall Clearances: The clearance from the inside of the front opening of the fireplace to any combustible wall should not be less than 3¹⁄₂” (Fig. 7A)
2. Ceiling Clearances: The ceiling height should not be less than 42” from the top of the fireplace opening. (Fig. 7A)
3. Mantel Clearances:
When installing an ANSI Z21.11.2 ventless appli­ance, the finishing material used for the mantel must be rated at 250°F or greater. Refer to firebox instruc­tions for any further information.
Without hood:
If no hood is installed, then there must be non-combustible material from the top front opening of the fireplace to a height of at least 20 inches and the full width of the fireplace. A combus­tible flat mantel shelf can be no closer than 38¹⁄₂” from the top front of the fireplace opening (Fig. 7B).
With hood:
If a hood is installed there must be non­combustible material from the top front opening of the fireplace to a height of 7¹⁄₂” and the full width of the fireplace. A combustible flat mantel shelf may be installed according to the detail in Figure 7C.
3A. Mantel Depth:
A combustible mantel can be no deeper than 8”, at 12” above the hood. (Figs. 7B and 7C)
4. Grate Clearance
The minimum clearance between the front legs of the grate and the front edge of the fireplace is 3” (Fig. 7B).
UVL Series
9
Page 10
Gas Line Connection
WARNING
Check the gas type. Use only the gas type indicated on the appliance rating plate. If the gas listed on the plate is not the type of gas supplied, DO NOT INSTALL the logset. Contact your dealer for the proper model.
Always use an external regulator for all LP appli­ances, to reduce the supply tank pressure to a maximum of 14” w.c. This is in addition to the regulator fitted to the heater.
The normal gas connection is made at the right side (facing the unit). If a left-side connection is desired, the connecting pipe may be directed under or behind the rear of the appliance, to terminate at the right­hand side for connection to the inlet of the appli­ance.
Connect the appliance to the gas line using fittings and aluminum tubing provided.
Close the valve knob on the appliance, turn the main gas supply valve ‘ON’, and carefully check all gas connections for leaks, with a soapy water solution or a sniffer. DO NOT TEST FOR LEAKS WITH AN OPEN FLAME.
Upon completing your gas line connection, a small amount of air will be in the gas lines. When first lighting the pilot, it will take a few minutes for the lines to purge themselves of air. Once the purging is complete, the pilot and burner will light and operate as indicated in this manual. Subsequent lightings of the appliance will not require purging.
Check the inlet pressure to the appliance, to ensure that it is as shown in the table on page 3. The minimum is for the purpose of input adjustment.
The pressure is controlled by the regulator and should be checked at the pressure test point located in the control valve body. Access to the pressure test point is obtained by removing all logs.
(UVL-M
series only)
The pressure should be checked with the appliance burning and the control set on ‘HIGH’.
The pressure regulator is preset and locked to avoid tampering. If the pressure is not as specified, replace the regulator. Refer to Replacement Parts.
After measuring the pressure, replace the test point plug. Ensure there are no leaks, then place the logs in their specified positions.
Connection directly to an unregulated LP tank can cause an explosion.
During the initial purging and subsequent lightings, never allow the gas valve control knob to remain depressed in the ‘Pilot’ position without lighting the pilot with a match or piezo ignitor.
There is a possibility of odor fade in LP. Never install an LP appliance or service line below grade without a gas detector.
Positioning the Logs
The logs must be positioned on the grate and locating pins, as shown in Figure 8. Make sure each bottom log engages the locator pins on the grate, and top logs are properly positioned in notches on tops of bottom logs.
Gas logs must be properly positioned or the appli­ance will not function properly, and may result in soot accumulation on the inside of the firebox and/or on the gas logs. Make sure there is no yellow
flame impingement on the logs which could result in excessive carbon monoxide emissions and carboning.
The optional volcanic rock may be applied to the hearth around the burner assembly.
Never place any other material on the burner.
WARNING
Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved for use with this appliance may result in property damage or personal injury.
1010
UVL Series
Page 11
UVL18
TPTH
TH
TP
UVL24 UVL30
LG112 LG113
Fig. 8 Positioning logs on grate assembly.
Fireplace Screen
The fireplace screen must be in place when the appliance is operating, and unless other provisions for combustion air are made, the screen must have openings for the introduction of combustion air.
5. Remote wall switch
(RN and RP models only)
1. Thread wire through the electrical knockout located on either side of the fireplace. Do not cut the wire or insulation on metal edges. Ensure that the wire is protected. Run the other end to a conve­niently-located wall receptacle box.
2. Attach the wire to the switch and install the switch into the receptacle box. Attach the cover plate to the switch.
3. Connect the wiring to the gas valve. One wire connects to the ‘TP/TH’ terminal; the other attaches to the ‘TH’ terminal. (Fig. 10)
LG114
To Wall Switch
OFF
Piezo Ignitor
Control Knob
ON
PILOT
Hi/Lo Knob
H
O
I
L
Fig. 9 Connecting a wall switch to the valve terminals. (UVL-R Series only)
751
NOTE: If any of the original wire as supplied with the appliance must be replaced, it must be replaced with a wire of at least a 60°C temperature rating.
UVL Series
11
Page 12
Operating Instructions
TPTH
TH
TP
The First Firing
On completing the gas line connection, a small amount of air will be trapped in the gas line. When you first light the unit with the pilot light, it will take a few minutes to purge the trapped air. Once you have purged the gas line, the pilot and burner will light and operate normally. Subsequent lightings of the appliance will not require purging the gas line.
When lit for the first time, the appliance will emit a slight odor for an hour or two. This is due to paint and lubricants used in the manufacturing process curing under heat. This is normal. You may wish to have the windows open to dissipate any odors during the curing process.
Control Knob
Red Glow
LG115
Fig. 13 UVL18 proper burner flame appearance.
Red Glow
ON
PILOT
OFF
HV101a
Piezo Ignitor
Fig. 10 Honeywell control valve.
HI
OFF
LO
PILOT
Fig. 11 EuroSIT control valve.
N
O
T
O
O
F
L
F
I
P
O
F
F
E A
H
F
O
Fig. 12 SIT control valve.
Flame Appearance
H
O
I
L
LG116
Fig. 14 UVL24 proper burner flame appearance.
Hi/Lo Knob
Red
Glow Piezo Ignitor
FP1036
LG117
Fig. 15 UVL30 proper burner flame appearance.
O
T
L
I
P
I
F
L
O
TH
TP
THTP
FP1395
R Series
Thermocouple
Thermopile
M Series
Thermopile
752
To obtain proper operation, it is imperative that the pilot and main burner flame characteristics are steady, not lifting or floating. Refer to Figure 13 -15 for proper burner flame appearance. Refer to Figure 16 for proper pilot flame appearance.
Typically, the top 1/8” of the thermopile should be engulfed in the pilot flame. (Fig. 16)
1212
P103
Fig. 16 Proper pilot flame.
UVL Series
Page 13
Lighting And Operating Instructions
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING:If you do not follow these instructions exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
A. This heater has a pilot which must be lit manu-
ally. When lighting the pilot follow these instructions exactly.
B. BEFORE LIGHTING smell all around the heater
area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any fireplace
• Do not touch any electric switch
• Do not use any phone in your building
•Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
Lighting Instructions
• If you cannot reach your gas supplier, call the Fire Department
C. Use only your hand to push in or turn the gas
control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Applying force or any attempted repair may result in a fire or explosion.
D. Do not use this fireplace if any part has been under
water. Immediately call a qualified service techni­cian to inspect the heater and to replace any part of the control system and any gas control which has been under water.
1. STOP! Read the safety information above.
2. Turn off all electrical power to the fireplace.
3. For MN/MP/TN/TP appliances ONLY, go on to Step 4. For RN/RP appliances turn the On/Off switch to “OFF” position or set thermostat to lowest level.
4. Open control access panel.
5. Push in gas control knob slightly and turn clockwise to "OFF".
O
L
T
I
1
t
o
l
i
P
2
F
F
O
5
3
4
P
F
F
O
O
F
F
Euro SIT SIT NOVA
ON
OFF
PILOT
ON
Honeywell
6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you do not smell gas, go to the next step.
7. Remove glass door before lighting pilot. (See Glass Frame Removal section).
8. Visibly locate pilot by the main burner.
9. Turn knob on gas control counterclockwise
to "PILOT".
10. Push the control knob all the way in and hold. Immediately light the pilot by repeatedly depressing the piezo spark ignitor until a flame appears. Continue to hold the control knob in for about one (1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8.
3/8" - 1/2"
If knob does not pop up when released, stop and immediately call your service technician or gas supplier.
If after several tries, the pilot will not stay lit, turn the gas control knob to "OFF" and call your service technician or gas supplier.
11. Replace glass door.
12. Turn gas control knob to “ON” position.
13. For RN/RP appliances turn the On/Off switch to “ON” position or set thermostat to desired setting.
14. Turn on all electrical power to the fireplace.
1. Turn the On/Off switch to Off position or set the thermostat to lowest setting.
2. Turn off all electric power to the fireplace if service is to be performed.
3. Open control access panel.
UVL Series
To Turn Off Gas To Heater
4. Push in gas control knob slightly and turn clockwise to "OFF". Do not force.
5. Close control access panel.
13
Page 14
START
Troubleshooting
Honeywell Valve (UVL-R series)
CHECK
Gas supply on
YES
Pilot lights with Piezo
YES
Pilot stays lit
NO
NO
NO
• Supply line hooked up
• Shutoff valve open
• Lockout has engaged. Wait 60 seconds and try again
• Piezo screws are tight for good ground
• For spark at electrode while depressing piezo - 1/8” gap to pilot hood needed
• All wiring connections
• Replace piezo ignitor
• For air in the lines
• Thermopile needs a minimum of 325mV
• All wiring connections
• Replace thermopile
• Thermocouple needs a minimum of 14mV
• Defective valve. turn to pilot, meter should read greater than 100mV. If not, replace the valve.
YES
Pilot lights main burner
YES
System OK
1414
NO
• Valve turned on
• Wall switch is not turned on
• Thermopile needs a minimum of 325mV
• Plugged burner
UVL Series
Page 15
Troubleshooting
SIT 630 Eurosit Valve (‘M’ Series)
With proper installation and maintenance, your new Gas Appliance should provide years of trouble-free service. If you do experience a problem, this guide will help a diagnosis of problems and the corrective action to take.
SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION
CERTIFIED SERVICE PERSON
in the
1. Pilot will not light with piezo ignitor or match.
2. Pilot will not stay lit after carefully following the lighting instructions.
3. No gas to main burner with pilot flame burning and valve turned to ‘High-Low’ range.
A. Main shutoff valve closed. B. Air in the gas line. C. Pilot orifice plugged, not
letting gas flow.
D. No gas supply to the
fireplace.
A. Defective thermocouple. B. Thermocouple fitting not
tight in valve.
C. Weak pilot flame.
D. Defective valve. E. Not enough oxygen in the
(Danger!)
room.
A. Plugged main burner
orifice.
B. Defective valve.
1. Make sure that the shutoff valve located on the pipe supplying gas to the fireplace is open.
1. Light a match, turn gas valve knob to ‘PILOT’ position and depress. Keep match near pilot burner till it lights.
1. Replace the burner assembly.
1. Check plumbing to see if gas fireplace has been hooked up to the gas supply line.
2. Propane tank is empty.
1. Replace burner assembly.
1. Carefully tighten the fitting.
1. The pilot flame must engulf the thermocouple. Clean for maximum flame impingement on the thermocouple. (Fig. 12)
1. Replace the burner assembly.
1. Open the door and get fresh air
1. Replace the burner assembly.
1. Replace the burner assembly.
at once!
UVL Series
15
Page 16
Maintenance and Safeguards
Keep the control compartment, logs and burner area around the logs clean by vacuuming or brushing at least twice a year. At altitudes above 4,500 feet (1370m) monthly cleaning is recommended.
THE LOGS CAN GET VERY HOT. HANDLE ONLY WHEN COOL.
Always turn off gas to the pilot before cleaning. For relighting, refer to the lighting instructions.
The appliance and venting system (if used) should be inspected before initial use, and at least annually by a qualified field service person.
Always keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.
Never obstruct the flow of combustion and ventilation air. Keep the front of the appliance clear of all ob­stacles and materials.
Leave clearance of at least 36” from the front of the fireplace.
Although your gas logs are very realistic in appear­ance, the fireplace must not be used for burning any solid fuels.
To avoid irreparable damage to the appliance or personal injury, matches, paper, garbage, or any other material must not be placed or thrown on top of the logs or into the flames.
To avoid personal injury, do not touch hot surfaces when the appliance is operating. Touch only the valve control knob. Avoid contact with the grate feet or prongs, or any other part which may be very hot.
Always ensure that the fireplace screen is closed when the appliance is operating.
Any safety screen or guard removed for servicing the appliances must be replaced before operating the appliance.
Close supervision is necessary when the appliance is being operated near children.
The appliance is intended for use as a gas heater mounted in a vented or unvented fireplace as de­scribed in the installation section of these instruc­tions. It should not be used for any other purpose.
Inspecting the Venting System
A vented fireplace venting system is designed and constructed to develop a positive flow adequate to remove flue gasses to the outside atmosphere. See vented fireplace installation instructions.
Any foreign objects in the venting system, except those designed specifically for the venting system, may cause spillage of the flue gases into the room.
In extreme situations, carbon monoxide poisoning or suffocation may occur.
Periodic examination and cleaning of the venting system of the solid-fuel burning fireplace must be done frequently by the home owner or a qualified agency.
UVL System Maintenance
The UVL burner and control system consists of:
• Chassis
• Gas Orifice
• Grate assembly
• UVL18 - four (4) decorative logs UVL24 - five (5) decorative logs UVL30 - seven (7) decorative logs
• Gas valve assembly
• Pressure regulator (UVL18M and UVL24M only)
Most of these components require only occasional check-up and cleaning. Some may require adjust­ment. If repair is needed, it should be performed by a qualified technician.
In order to properly clean the burner and pilot assembly, turn off the gas to the unit and remove the logs, exposing the burner and pilot assembly. Clean all foreign materials from the top of the burner. Check to make sure that all burner parts are clean. Visually inspect the pilot. Brush or blow away any dust or lint accumulations.
NOTE: The burner and pilot assembly should be checked for any dust or lint at least every six months.
Replacement Parts
Contact the factory for questions about prices and policies covering replacement parts. Parts will be shipped at prevailing prices. Normally, all parts can be ordered through your CFM Specialty Home Products distributor or dealer.
When ordering replacement parts, always give the following information:
1. The model number of the appliance.
2. The part number
3. The description of the part. (See the Replace-
ment Parts List on Page 17)
4. The installation date of the appliance.
If you need more information, beyond what the dealer can furnish, contact CFM Specialty Home Products, 410 Admiral Blvd, Mississauga, Ontario, Canada L5T 2N6, Attention: Director of Technical Service
1616
UVL Series
Page 17
TPTH
TH
TP
1
c
c
b
a
f
g
2
4
3
5
e
d
8
6a,b
c,d
Piezo Ignitor
PILOT
OFF
LO
HI
9a,b
Screw
7
12a,b
20
10
11
ON
P
IL
O
T
OFF
H
O
I
L
14a,b
15a,b
13a,b
16
17
19
21a,b
CFM Specialty Home Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
UVL18/24/30 Premium Vent Free Gas Logs
Ref. Description UVL18 UVL24 UVL30
1. Complete Log Set 20001420 20001421 20001893
18a,b
957
1a. Back Log 7583180 7583175 20001892 1b. Right Cross Log -- 7583177 20001886 1c. Left Cross Log 7583181 7583176 20001889 1d. Front Log 7583178 7583173 20001890 1e. Middle Log 7583179 7583174 20001891
1f. Middle Left Log -- -- 20001888
UVL Series
17
Page 18
UVL18/24/30 Premium Vent Free Gas Logs (continued)
Ref. Description UVL18 UVL24 UVL30
1g. Middle Right Log -- -- 20001887 2a. 3/8” Flare Tubing 7060120 7060120 7060120 2b. 3/8” Flare Tubing (M Series) 20004146 20004146 --
3. Volcanic Rock 20000198 20000198 20000198
4. Elbow Fitting 1/2” NPT (F) x 3/8” Flare 7523184 7523184 7523184
5. Damper Stop 7540310 7540310 7540310 or 3030176 3030176 3030176
6a. Burner Supply Assembly - Main Orifice (RP) 20000120 20000124 20001878 6b. Burner Supply Assembly - Main Orifice (RN) 20000119 20000123 20001877 6c. Burner Supply Assembly - Main Orifice (MN) 20000121 20000125 20001875 6d. Burner Supply Assembly - Main Orifice (MP) 20000122 20000126 20001876 7a. Orifice Hood - Front (MP,RP) 20000134 20000133 30000339 7b. Orifice Hood - Front (MN, RN) 20000130 20000132 30000337
8. Front Leg Assembly 3081122 3081122 20001862
9a. Gas Valve - SIT - MN Series 20001354 20001786 20001786 9b. Gas Valve - SIT - MP Series 20001355 20001787 20001787
10. Valve Cover - M Series (includes Piezo & Screw) 51851 51851 51851
11. Piezo Ignitor - M Series & R Series - SIT Valve 52464 52464 52464 12a. Pilot Assembly - MN Series 20001356 20001356 20001356 12b. Pilot Assembly - MP Series 20001357 20001357 20001357 13a. Gas Valve - Honeywell - RP 10000242 10000242 10000242 13b. Gas Valve - Honeywell - RN 10000235 10000235 10000235 14a. Knob Extension (Hi/Lo) - Honeywell Valve 20000006 20000006 20000006 14b. Knob Extension (HI/LO) - SIT Valve 55162 55162 55162 15a. Knob Extension (ON/OFF) - Honeywell Valve 20000007 20000007 20000007 15b. Knob Extension (ON/OFF) - SIT Valve 55163 55163 55163
16. Piezo Ignitor - R Series - Honeywell Valve 20000062 20000062 20000062
17. Piezo Extension (R Series only) 20001427 20001427 20001427 18a. Pilot Assembly - RP 55465 55465 55465 18b. Pilot Assembly - RN 55464 55464 55464
19. Ignitor Cable (M and R Series) 20004419 20004419 20004419
20. Access Panel Assembly 3085109 3081120 20001860 21a. Gas Valve - SIT - RN 55463 55463 55463 21b. Gas Valve - SIT - RP 55462 55462 55462
1818
UVL Series
Page 19
Accessories
The following accessories are available from your Vermont Castings Dealer. If you need additional informa­tion beyond what your dealer can supply, contact CFM Specialty Home Products, 410 Admiral Blvd, Missis­sauga, Ontario, Canada L5T 2N6, Attention: Technical Service.
Accessory Description Model Number
Required to protect wall above fireplace and/or mantel in certain applications.
AC100
Contact CFM Specialty Home Products with ques­tions concerning prices and policies covering re­placement parts. Parts may be ordered through your Vermont Castings distributor or dealer.
You will need the following information when ordering replacement parts:
• The appliance model number.
• The serial number.
•A description of the part.
Should you need additional information beyond what your dealer can furnish, contact:
CFM Specialty Home Products 410 Admiral Blvd. Mississauga, Ontario Canada L5T 2N6
AH3244BK (BLACK) AH3244PB (POLISHED BRASS)
Model and serial numbers are listed on the rating plate (located on right side of combustion cham­ber).
Record your model and serial number here for future reference.
Model #__________________________________ Serial # __________________________________
UVL Series
19
Page 20
2020
UVL Series
Page 21
LIMITED 2/20 YEAR WARRANTY
For VERMONT CASTINGS® Vent-Free Gas Appliances
CFM Specialty Home Products (Company) extends the
warranties specified in paragraphs A and B below with respect to its VERMONT CASTINGS Decorative Gas Appliances (the “Gas Appliance”), including the CFM Specialty Home Products supplied accessories and components referred to in those paragraphs, subject to the following conditions and limitations:
(1) These warranties are extended only to the Gas
Appliance installed in the continental United States, including Alaska, and Canada; only if and so long as the accordance with the installation and operating instructions furnished therewith; and only if and so long as Gas Appli­ance is not removed from its original installation.
(2). These warranties are limited to only the component
parts manufactured and supplied by CFM Specialty Home Products. The use of components manufactured by others with the Gas Appliance could create serious safety hazard, may result in the denial of certification by recognized national safety agencies, and could be in violation of local building codes.
(3). The Gas Appliance must be operated at all times in
accordance with the operating instruction furnished there­with. The Gas Appliance is designed to burn either natural or propane gas only. Burning conventional fireplace fuels such as wood, coal, or any other solid fuel will cause damage to the Gas Appliance, will produce excessive temperatures and will result in a fire hazard.
(4). These warranties are limited to repair, replacement or
furnishing a replacement for sale, as specified in Para­graphs A and B, for a part found to CFM Specialty Home Products satisfaction, after examination, to be defective in materials or workmanship under normal conditions, use and service. (5). All obligations with respect to these warranties may be fully discharged by CFM Specialty Home Products refunding the wholesale price of a defective part. (6) Except as otherwise expressly specified in Paragr aphs A and B. NONE OF THESE WARRANTIES COVER, AND CFM SPECIALTY HOME PRODUCTS SHALL NOT BE RESPONSIBLE FOR, ANY CONSTRUCTION, INSTAL­LATION, LABOR, TRANSPORTATION OR OTHER COSTS OR EXPENSES ARISING FROM A DEFECTIVE PART, ITS REPAIR OR REPLACEMENT OR OTHERWISE, NOR SHALL CFM SPECIALTY HOME PRODUCTS IN ANY EVENT BE RESPONSIBLE FOR ANY INDIRECT, INCI­DENTAL OR CONSEQUENTIAL DAMAGES. EXCEPT TO THE EXTENT PROVIDED BY LAW, THERE ARE NO IMPLIED WARRANTIES WITH RESPECT TO THE GAS APPLIANCE, ITS COMPONENTS AND ACCESSORIES (INCLUDING IMPLIED WARRANTIES OF MERCHANT­ABILITY OR FITNESS FOR A PARTICULAR PURPOSE),
UVL Series
ALL OF WHICH ARE HEREBY EXPRESSLY INCLUDED. IN NO EVENT SHALL ANY IMPLIED WARRANTY PRE­SCRIBED BY LAW (NOTWITHSTANDING THE FOREGO­ING EXPRESS EXCLUSION) REMAIN IN EFFECT AFTER EXPIRATIONS OF THE WARRANTIES SET FORTH IN PARAGRAPHS A AND B.
A. Gas Appliances, electrical and manual compon
ents, glass panels, all sealants or adhesives and optional accessories (exclusive of CFM Specialty Home
Products supplied decorative logs which are covered by a separate warranty under paragraph B below): Within two years from the date of manufacture of the gas appliance, CFM Specialty Home Products will repair, or replace (at our option) a defective part without charge.
B.
CFM Specialty Home Products
logs, or firebox liners:
Within two years from the date of manufacture of the gas appliance, CFM Specialty Home Products will replace a defective part without charge. Within years three through twenty from the date of manufacture of the gas appliance, CFM Specialty Home Products will provide a replacement for a defective part to the homeowner, but assumes no liability for incurred labor cost. The foregoing warranties gives you specific legal rights and you may also have other rights which vary from state to state. Some states do not allow limitations on how long an implied warranty may last, so the limitation specified above on the duration of any implied warranty prescribed by law may not apply to you. Similarly, some states do not permit the exclusion or limitation of incidental or consequential damages, so the above exclusion of such damages may not apply to you.
In order to obtain performance of any of the above warranty obligations, write to CFM Specialty Home Products at this address:
CFM Specialty Home Products
410 Admiral Blvd. Mississauga, Ontario Canada L5T 2N6 Attention: Director of Warranty Services
Since local building requirements may vary greatly throughout the country, users of CFM Specialty Home Products products should determine in advance whether there are any building code restrictions on the use of a specified product. CFM SPECIALTY HOME PRODUCTS MAKES NO REPRE­SENTATION OR WARRANTY REGARDING, AND SHALL NOT BE RESPONSIBLE FOR, ANY BUILDING CODE
cement logs, fiber
COMPLIANCE.
The foregoing warranties give you specific legal rights and you may also have other rights which vary from state to state.
21