Vermont Castings TP-250 User Manual

Page 1
Burner Orifice (3 or 4) (Refer to Table 1 or 3 to Confirm Sizes)
Pilot Orifice
Fuel Conversion Kit
Installation Instructions
Kits: Natural to LP:
20011992, 20012367, 20012368
LP to Natural:
for Models: DVT38IN, DVT44IN, DVT38S2IN
WARNING! The installation of this conversion kit must only be undertaken by a qualified, certified gas appliance installer.
Valve Minimum Rate Screw (DVT44,DVT38S2)
Label
Valve Minimum Rate Screw (LP) (DVT38)
Fig. 1 Carton contents.
CAUTION: Logs may be hot.
3. Models DVT38, DVT44
a. With a Phillips or Robertson screwdriver, remove
the two (2) screws holding the fettle to the burner assemblies. With a hex, remove the two (2) hex nuts holding the burner tube to the front of the burner assembly. Remove burner tube.
b. With the 3/8” socket remove two (2) hex nuts
holding the left burner leg. Remove burner leg. (Fig. 2)
Pressure Test Adapter
CAR205
This kit is designed for conversion of the Direct Vent Gas Heater Models DVT38, DVT44 and DVT38S2 equipped with the American Flame AF-4000 Series valve.
Tools required for conversion: TORX T20 Security Tee bit, 3/8” and 1/2” deep well socket, Phillips or Robertson screwdriver, 5/32” allen wrench, small flat blade screw-
driver, 7/16” nut driver or socket.
Check Contents of Shipping Carton
Compare contents of Figure 1 with actual parts re­ceived. If any parts are missing or damaged, contact your dealer before starting conversion.
Conversion Precautions
Allow unit to cool if it has been operating.
Before proceeding with conversion shut off fireplace and turn gas supply OFF. Turn OFF any electricity that may be going to appliance.
Conversion Procedure
1. Remove glass frame. Refer to Homeowner’s Manual.
2. Remove lava rock, volcanic rock, embers and logs. Carefully remove brick panels.
Hex Nuts
Fig. 2 Use 3/8” socket to remove hex nuts holding left burner leg.
c. Slide the burner housing assembly to the left and
away. Adjust air shutter setting. Pull burner tube assembly forward and out. Adjust air shutter set­ting. Refer to Table 2.
d. Remove two (2) screws holding the pilot as-
sembly to the burner assembly. Move the pilot assembly toward the back.
e. Slide the burner housing assembly to the left and
away.
f. With the 1/2” socket, replace the three (3) injec-
tors. Refer to Table 1.
3. Model DVT38S2
a. With a Phillips or Robertson screwdriver, remove
the four (4) nuts holding the fettle to the burner assemblies. With a hex, remove the two (2) hex nuts holding each burner tube to the front of the
20012371 11/07 Rev. 3
FP1559a
1
Page 2
Hex Nuts
FP1476
Fig. 3 Use a 3/8” socket to remove hex nuts holding burner legs.
burner assembly on both sides. Remove burner tubes.
b. Remove two (2) hex nuts holding the left burner
leg. Remove burner leg. (Fig. 3)
c. Remove two (2) screws holding the pilot assem-
bly to the burner assembly. Move the pilot assem­bly toward the back.
d. Slide the burner housing assembly to the left and
away.
e. Replace the four (4) injectors. Refer to Table 3.
5. Remove pilot orifice with 5/32” Allen wrench. (Fig. 5)
6. Install the conversion orifice.
7. Reinstall pilot hood. Be sure to align hood with index tab.
Valve Conversion
1. Remove two (2) screws holding the pilot assembly to the burner assembly. Move the pilot assembly toward the back wall.
2. Using a back-up wrench, disconnect the gas supply fitting near the right rear corner of the firebox.
3. Remove four (4) screws holding the burner assem
-
bly to the firebox floor.
4. Carefully slide the burner assembly out of the way.
5. Remove 13 screws around the perimeter holding large access panel on the of the firebox.
6. Carefully pull back the panel just enough to gain access to control box.
7. Locate the black plastic cap on the gas valve. (Fig.
6) Remove the black cap by pulling the cap straight off. Note the position of the marker on the top of the rotary knob. This marker will point to NAT or LP. (Fig. 7)
Black Plastic Cap
Pilot Hood
Pilot Bracket
CO133
Fig. 4 Remove pilot hood.
Index Tab
Snap Ring
Fig. 5 Remove pilot orifice.
Allen Wrench
CO134
Replace Pilot Orifice
4. Remove pilot hood by lifting up. (Fig. 4) NOTE: It is not necessary to remove the pilot tube for conver­sion.
Minimum Rate Screw
CO138
Fig. 6 AF4000 Valve in place.
Front of Fireplace
8. To convert the valve from NG to LP, push in the knob and rotate 90° (1/4 turn). NOTE: The shaft should point to LP. The shaft will remain pushed-in.
9. Remove the slotted brass minimum rate screw located in the valve next to the motor drive. (Fig. 7)
10. Replace the minimum rate screw with the one provided in the LP conversion kit supplied with this fireplace. Ensure the screw is fully installed.
11. Install the enclosed identification label to the valve body where it can be easily seen.
12. Reinstall steel panel.
22
Page 3
 
Pilot Adjustment Screw
Gas Type Marker
CO137
Fig. 7 Remove black plastic cap and adjust rotary knob to correct gas type. (LP position shown) Replace minimum rate screw with one supplied in conversion kit.
Minimum Rate Screw
13. Reinstall burner to original position. Reinstall burner leg, burner tube and fettle. Re-attach supply tube to gas supply fitting. Using a back-up wrench, tighten securely.
14. Test for leaks. Apply electric and gas to the system.
15. Light the pilot burner using the remote control. With soapy solution check for leaks around the pilot as­sembly where the tube enters the pilot assembly. Tighten fitting if necessary.
16. Light the main burner and check for leaks around the burner supply tube fittings and burner orifices. Tighten if necessary.
17. Turn fireplace OFF.
18. After the conversion and leak checks have been made, manifold outlet pressure can be checked with a manometer at the test ports located at the side front edge of the fireplace opening. The lower test port is manifold outlet pressure.
CAUTION: Turn off the gas supply before removing test port plug.
19. Using a 7/16” nut driver, remove the threaded plug from the test port.
20. Thread the supplied extension adaptor into the open test port.
21. Attach a 1/4” diameter pressure gauge flexible hose fully onto the barb of the adaptor.
22. Turn on gas supply and operate valve with remote control as needed to indicate gas pressure. The manifold pressure for LP should be approximately
10.0” wcp.
CAUTION: Turn off the valve and gas supply before removing test port adaptor and replac­ing plug.
23. After test, remove adaptor and replace plug.
24. Turn on gas supply and check that plugs are tight and leak free.
25. Follow instructions in Homeowner’s Manual to re-assemble brick panels, logs, lava rock, volcanic rock, embers and andirons.
26. Replace glass frame.
27. Conversion complete.
Pilot Flame Adjustment
Typically, the top 3/8” or 1/2” of the thermopile should be engulfed in the pilot flame. (Fig. 8)
To adjust pilot burner: Adjust pilot screw on valve to provide properly sized flame..
FP1229a
Fig. 8 Correct pilot flame appearance.
3
Page 4
Table 1 Injector Orifice Size Matrix
Conversion to LP Burner Orifice Input (BTU/hr) Kit # Model Front Part # Middle Part # Rear Part # Minimum Maximum
20011992 DVT38IP #66 20009182 #59 20000664 #50 30000337 36,000 46,000 (.033”) (.041”) (.070”)
20012367 DVT44IP #63 20006251 #57 20004587 #49 20006252 45,000 60,000 (.037”) (.043”) (.073”)
Conversion to Natural Gas Burner Orifice Input (BTU/hr) Kit # Model Front Part # Middle Part # Rear Part # Minimum Maximum
20013200 DVT38IN #54 20000130 #54 20000130 #30 20009175 32,000 46,000 (.059”) (.055”) (.128”)
20013199 DVT44IN #53 20007347 #40 20004263 #23 20009044 37,000 60,000 (.059”) (.098”) (.154”)
Table 2 Air Shutter Settings
Conversion to LP or Natural Gas
Burner Tube Burner Housing Model Air Shutter Setting Air Shutter Setting
DVT38IP Fully open n/a DVT44IP Fully open Fully open
Table 3 DVT38S2 Injector Orifice Size Matrix
Conversion to LP
KiT # Burner 20012368 Burner Housing/ Burner Burner Input (BTU/hr) Model Housing Part # Pilot Part # Tube Part # Tube Part # Min. Max.
DVT38S2IP #55 30000333 #54 20000130 #57 20004587 #57 20004587 45,000 56,000 (.052”) (.055”) (.043”) (.043”)
Conversion to Natural Gas
KiT # Burner 20013196 Burner Housing/ Burner Burner Input (BTU/hr) Model Housing Part # Pilot Part # Tube Part # Tube Part # Min. Max.
DVT38S2IN #38 20009310 #38 20009310 #45 20010169 #45 20010169 38,000 56,000 (.101”) (.101”) (.082”) (.082”)
Table 4 Valve Minimum Rate Screw
Model Drill Size Part # ID Stamp DVT38IP #31 (.120”) 20012364 31 DVT44IP No Shank 20012264 00 DVT38S2IP Screw DVT38IN DVT44IN No Shank 20013198 0 DVT38S2IN Screw
44