PDV20/SDVR Installation Procedure – for Pinnacle Direct Vent
1. Attach the Snapstat to the Bracket using two #10 x 1/2” phillips screws as shown in Figure 1.
2. Locate and remove the 1/4-20 x 3/8” hex head bolt installed in the hole in the right rear ledge of the fire box. (A, Fig. 1) Use that bolt to secure the Snapstat Bracket to the firebox. The mounting hole is slotted to let you adjust the bracket so that the snapstat head makes contact with the firebox surface. (Fig. 1)
3. Attach the Fan to the firebox by engaging the upper flange of the fan skirt under the lower edge of the Shroud and secure the skirt with the four #10 x 1/2” Hex Hd Cap screws and one star washer provided. (Fig. 2)
1/4-20 x 3/8”
Hex Bolt
Bracket
Snapstat
A
1/2” Sheet
Metal Screws
Fig. 1 Snapstat assembly and installation. (PDV20 shown)
-
The Fan Kit FK28/2960 attaches to the rear shroud of the PDV20/SDVR Direct Vent heater, the UVS27 Unvented, Jefferson Direct Vent, Jefferson JUV Unvented heaters and the Seville Woodburning Stove. Installation for the PDV20 should be made after the fire­box is set within the stove shell but before connection to the gas supply. Installation for the UVS27 should be made before the firebox is set within the shell. Installa­tion for the Jefferson Direct Vent and JUV may be made at any time during assembly. Installation for the Seville should be made before the stove is removed from the shipping pallet. Follow the procedure for the appropriate firebox model.
The kit includes a snapstat sensor which turns the fan on or off at approximately 109˚F. Be sure the heater is cool before beginning the installation.
Fan Kit Contents:
• #10 x 1/2” Phillips screws, 6
• Star Washer • Wire Tie
• Control Knob • Retaining Nut
• Snapstat • Snapstat Bracket
• Blower Assembly w/ Rheostat Control and Snapstat
• Silicone Tape
Rheostat Control
Fig. 2 The upper flange of the fan skirt should be located behind the lower edge of the shroud. (PDV20 shown)
Upper Flange
Sheet Metal Screws (4)
Fig. 3 Correct position of fan skirt installation. (PDV20 shown)
30000275 8/08 Rev. 6
4. The Rheostat Control switch attaches to the Control Panel plate provided in the parts bag with the stove.
• Insert the switch box shaft through the hole in the back of the right side of the Panel, aligning the loca­tor pin with the smaller hole in the panel. (Fig. 4)
• Attach the Retaining Nut to the switch control shaft to secure it to the plate.
• Attach the Control Knob to the rheostat shaft.
• Use the wire tie to secure the fan and rheostat wire harnesses together to the tubing under the bottom heat shield.
Do not install the Control Panel onto the stove until after the gas supply and valve wiring connections have been made. See Assembly Instructions, PDV20/SDVR Owner’s Guide.
Rheostat
Control Panel
Fig. 4 Attach the Rheostat to the Control Panel.
Retaining Nut
Control Knob
5. A length of silicone tape is included for installation between the Top Plate and the Rear Shroud, should you find that contact between these two surfaces causes vibration while the fan is operating.
• Remove the Top Plate.
• Cut the self-adhesive tape to size as needed, remove the backing paper and place tape on the top edge of the Shroud at those locations where it will eliminate direct contact between the Shroud and the Top Plate. (Fig. 5)
• Replace the Top Plate.
UVS27 Installation Procedure
– for Stardance and Pinnacle Vent-Free
1. Attach the Fan assembly to the rear shroud in the same manner as detailed in the preceding section for the PDV20/SDVR, following Step 3, Figures 2-3.
2. Disconnect the snapstat module from the leads inside the snapstat bracket. (Fig. 6)
3. Bend open the snapstat bracket. Use your fingers or needle nose pliers to remove the black plastic grommet from the bracket. Discard the grommet and bracket.
4. Feed the snapstat wire lead up between the in­ner and outer rear shroud panels and secure the snapstat to the upper right side of the inner shroud. (Fig. 7)
5. Secure the snapstat wire harness to the shroud panel using the wire tie provided with this kit.
6. Route the rheostat control switch and wire forward under the stove. Use the wire tie to secure the fan and rheostat wire harnesses together to the tub­ing under the bottom heat shield. UVS27R / Honeywell Millivolt Valve: Install the rheostat onto the control panel at the hole to the right of the valve, as in Figure 4. UVS27M / SIT Manual Valve: Install the rheostat onto the bracket to the left of the valve.
Pinch Grommet to Remove