Installation and Operation Instructions for Vented Gas
CER TIF IED
D
E
S
I
G
N
C
E
R
T
I
F
I
E
D
Log Set - DragonFire Hearth Kits
Models A18CFLRN/P, A24CFLRN/P, A30CFLRN/P
DECORATIVE GAS APPLIANCE FOR INSTALLATION IN SOLID FUEL BURNING FIREPLACES
Design Certified to ANSI Z21.60 and CGA 2.26 Standards
W A R N I N G
IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT,
CAUSING PROPERTY DAMAGE, INJURY, OR LOSS OF LIFE.
FOR YOUR SAFETY:
DO NOT STORE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS NEAR THIS OR ANY
OTHER APPLIANCE.
WHAT TO DO IF YOU SMELL GAS:
• SHUT OFF ALL GAS TO THE APPLIANCE.
• OPEN WINDOWS; DO NOT TOUCH ANY ELECTRICAL SWITCHES. DO NOT USE ANY PHONE IN
YOUR BUILDING.
• DO NOT TRY TO LIGHT ANY APPLIANCE; EXTINGUISH ANY OPEN FLAME
• IMMEDIATELY PHONE YOUR GAS SUPPLIER FROM A NEIGHBOR’S PHONE. FOLLOW THE SUPPLI-
ER’S INSTRUCTIONS.
• IF YOU CANNOT REACH THE GAS SUPPLIER, PHONE THE FIRE DEPARTMENT.
ATTENTION
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED AGENCY, INDI
VIDUAL, FIRM, CORPORATION, OR COMPANY,
EXPERIENCED IN THE INSTALLATION, REPAIR,
AND SERVICING OF THIS TYPE OF GAS APPLI
-
-
INSTALLER PLEASE NOTE:
DO NOT BEGIN INSTALLATION OF THIS GAS
LOG SET UNTIL ALL INSTRUCTIONS HAVE BEEN
READ AND UNDERSTOOD. AFTER INSTALLA
TION, LEAVE THESE INSTRUCTIONS WITH THE
OWNER.
-
ANCE. DO NOT MODIFY, ALTER OR TAMPER
WITH ANY PART OF THIS HEATER, CONTROL,
OR LOGS. INSTALLER, CHECK LOCAL CODES
BEFORE INSTALLING THIS LOG SET. IN SOME
AREAS OF THE COUNTRY GAS LOG SETS ARE
RESTRICTED.
READ THESE INSTRUCTIONS AND FOLLOW
THE WARNINGS.
GAS LOG’S MODEL NUMBER FOR FUTURE
REFERENCE:
Improper installation, adjustment, alteration, service or maintenance can cause injury or property
damage. Read these directions thoroughly before installation. For assistance or additional information, consult your gas log dealer, qualified installer, service agency or
gas supplier.
WARNING
Do not use this appliance or any part that has
been under water. Immediately call a qualified
service technician to inspect the appliance and
to replace any part of the control system and
any gas control which has been under water.
If not installed, operated, and maintained in
accordance with the manufacturer’s instructions, this product could expose you to substances in fuel or fuel combustion which are
known to the state of California to cause cancer, birth defects, or other reproductive harm.
WARNING
WARNING
A properly sized, unobstructed chimney will normally vent all fumes and products of combustion. Any
odor or smoke detected in the room is an indication that the flue is not properly removing the combustion products. Turn off the gas supply valve immediately! The cause of the venting problem must be
discovered and corrected before using this gas log set. Disregarding this warning can cause illness as
well as soot damage to your fireplace, room, and furnishings.
WARNING
Young children are not allowed to operate this unit and must be supervised when they are in the same
room as the appliance. Due to high temperatures, the appliance should be located out of traffic and
away from furniture and draperies. In addition, clothing or other flammable material should not be
placed on or near the appliance.
Technical Information
The operation of a gas log set, and the provision for combustion and ventilation air must
conform with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 and applicable codes.
Gas Pressure Testing: This gas log set and its individual shut-off valve MUST be
disconnected from the gas supply piping system during any pressure testing of that system at test
pressures in excess of 1/2 psig (3.5 kPA). The gas log set must be isolated from the gas supply piping
system by closing its individual manual shut-off valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than 1/2 psig (3.5 kPa)
Component Parts: Only factory authorized components listed in these instructions may be used in
accordance with the manufacturer’s instructions and all codes and requirements of the authority having jurisdiction. Any modifications to this kit, or use of unauthorized components or accessory items
will void the manufacturer’s warranty, and may result in a hazardous condition.
220003903
Before You Begin -- ATTENTION!
A. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from
carpeting, bedding material, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean.
B. Your fireplace must include a chain mesh or similar screen. The screen must remain fully closed while operating your log set. Any safety screen or guard removed for
servicing this appliance must be replaced prior to operation.
C. If your fireplace includes glass doors, they must remain fully open to allow for combustion air during operation, and to prevent overheating of the gas valve.
D. Your log set must be installed in a solid fuel burning fireplace constructed of
noncombustible material with a working flue.
E. Solid fuels shall not be burned in the fireplace where your gas log set is installed.
F. If this log set is to be used with propane gas, your propane supply tank MUST include a high to low gas pressure regulator, and must be located outside. DO NOT place supply tanks inside any structure .
G. Never use sand or other dense pan material with propane gas: use vermiculite only.
H. Be sure to apply pipe joint compound to all non-flared, threaded connections involved in this installation to avoid possible gas leaks. Compounds used in liquid propane
applications must be resistant to the action of that gas.
I.Always test for leaks using a soapy solution. NEVER USE OPEN FLAME.
J. The manufacture and shipping of your log set involves compounds which may cause detectable yet harmless odors during initial operation. Provide extra ventilation to the room for the initial 2-3 hour break-in period.
K. This gas log set may be installed in the approved fireplace in an aftermarket* manufactured (mobile) home where not prohibited by state or local codes.
*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.
L. The fireplace damper MUST be fully open when operating this log set.
Fireplace Specifications
Before installation, the chimney flue, venting system, and firebox must be cleaned of all soot,
creosote, ashes and loose paint, by a qualified chimney cleaner.
• A working flue and venting system with the minimum openings indicated on Page
• A gas supply shut off valve. If your fireplace does not have such a valve, one must be installed.
20003903
Your Fireplace Must Include:
.
3
Pre-Installation Check List
Is the gas supply inlet pressure correct?
NG: Min. 5.0” w.c./ Max. 10.5” w.c. LP: Min. 11.0” w.c.;Max. 14.0” w.c.
Does the firebox meet the minimum size dimensions below?
Is your fireplace plumbed with gas on the right side (facing) of the fireplace? If not, see
page 10.
Is the gas supply line sized properly (Minimum 1/2” Iron Pipe)?
Do you have a solid fuel (wood burning) fireplace with a vented flue?
Do you have a manual gas supply valve installed at your fireplace? If not, a licensed
plumber, gas company technician or other qualified installer must install one.
Have you checked local building codes? (Check with your local Building Dept.)
Does you fireplace have a wire mesh screen in place?
YES NO
CAUTION: If you answered “NO” to any item, or have any questions regarding your installation,
please contact your dealer/distributor for assistance.
Natural Gas Units -- Minimum Clearances & Specifications
8” adjustable crescent wrench; Pipe thread sealant compound or teflon tape; 12” pipe wrench or channel
lock pliers.
Gas Plumbed on Left Hand Side of Fireplace
NOTE: Your gas log set is assembled at the factory to be installed in a fireplace plumbed with the gas on
the right side (facing). If your fireplace is plumbed with the gas on the left side remove fittings on right and
left side of straight burner tube and switch sides, at the same time put front burner tube on right side with
the elbow fitting. (Fig. 5b)
You may also run a flexible connector (or as per local codes) along the back wall of the fireplace to bring
your gas line to the right hand side. You can then place the set in front of the flexible connector. (Fig. 5a)
Damper Stop Installation:
For Use with BR, BC, SR, SC, TF and TL Series CFM Specialty Home Products Fireplaces
This Damper Stop is designed to work on all CFM
Specialty Home Products BR, BC, SR, SC, TF and
TL series fireplaces. For all other fireplaces, refer
to Page 6.
When installing a decorative gas appliance in a
fireplace, some local codes require this Damper
Stop to be used so the Damper will not close completely. To install the Damper Stop:
The Damper Locking Bracket is already installed
on all BR, BC, SR, SC, TF and TL fireplaces. Locate the Damper Locking Bracket on the left side
of the fireplace’s Combustion Dome.
(Fig. 1)
With the Damper open, align the two slots on
either side of the cut-out on the Damper Stop with
the two small holes on the angled portion of the
Damper Locking Bracket. Attach the Damper
Stop with the Screws provided, as shown in
Figure 2.
Figure 1
Damper
Plate
Damper Locking Bracket
LS854
Damper Locking Bracket
NOTE: Some of the early fireplace units may not
have the holes in the end of the Damper Locking Bracket. If this is the case, use the Damper
Stop as a template to drill two (2) 1/8” holes in the
Damper Locking Bracket to mount the Damper
Stop.
20003903
Damper Stop
Figure 2
Damper
Stop Screw
LS855