PLEASE READ THIS MANUAL
BEFORE INSTALLING AND
USING APPLIANCE.
Electric Fireplace
WARNING!
IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED
EXACTLY, AN ELECTRICAL
SHOCK OR FIRE MAY RESULT,
CAUSING PROPERTY DAMAGE,
PERSONAL INJURY OR LOSS
OF LIFE.
FOR YOUR SAFETY
SERVICE MUST BE
PERFORMED BY A QUALIFIED
SERVICE AGENCY.
DO NOT STORE OR USE
GASOLINE OR OTHER
FLAMMABLE VAPORS AND
LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER
APPLIANCE.
1. Read all instructions before using this appliance.
2. This appliance is hot when in use. To avoid burns, do
not let bare skin touch hot surfaces. If provided, use
handles when moving this appliance. Keep combustible materials, such as furniture, pillows, bedding,
papers, clothes and curtains at least
3 feet (1 m) from the front of this appliance.
CAUTION: Extreme caution is necessary
when any heater is used by or near children or invalids, and whenever the heater
is left operating and unattended.
3. Do not operate any heater if the appliance malfunctions, or if it has been dropped or damaged in any
manner.
4. Any repairs to this fireplace should be carried out by
a qualified service person.
5. Under no circumstances should this fireplace be
modified. Parts having to be removed for servicing
must be replaced prior to operating this fireplace
again.
6. Do not use outdoors.
7. This heater is not intended for use in bathrooms,
laundry areas and similar indoor locations. Never
locate this appliance where it may fall into a bathtub
or other water container.
8. This appliance, when installed, must be electrically
grounded in accordance with local codes, or, in the
absence of local codes, with the current CSA C22.1
Canadian Electrical Code; for U.S.A. installations,
follow local codes and the National Electrical Code,
ANSI/ NFPA NO. 70.
9. Do not insert or allow foreign objects to enter any
ventilation or exhaust opening, as this may cause an
electric shock or fire, or damage the appliance.
10. To prevent a possible fire, do not block air intake or
exhaust in any manner. Do not use on soft surfaces
(e.g., beds) where openings may become blocked.
11. This appliance has hot and arcing or sparking parts
inside. Do not use it in areas where gasoline, paint or
flammable liquids are used or stored. This fireplace
should not be used as a drying rack for clothing, nor
should Christmas stockings or decorations be hung
in the area of it.
12. Use this appliance only as described in this manual.
Any other use not recommended by the manufacturer may cause fire, electric shock or injury to persons.
13. Do not burn wood or other materials in this fireplace.
TBREF Electric Fireplace
14. Do not strike the fireplace glass.
15. Always use a certified electrician for installation.
16. Disconnect all power coming to fireplace at main
service panel before performing any cleaning or
maintenance.
17. Do not install this fireplace on carpet or vinyl floors,
as discoloration may occur.
18. SAVE THESE INSTRUCTIONS.
Wiring
Ensure the power conversion/switch (if
equipped) is in the proper position for required supply voltage prior to connecting
the unit to power supply.
Do not use this fireplace if any part of it
has been under water. Immediately call a
qualified service technician to inspect the
fireplace and replace any part of the elec
trical system that has been under water.
A qualified electrician must perform any
electrical wiring of this appliance. This wiring must be done in accordance with local
codes, and/or in Canada, with the current
CSA C22.1 Canadian Electrical code; for
U.S.A. installation, National Electrical Code
ANSI/NFPA No. 70.
NOTES: The unit is shipped from the factory config
ured for 120 Volt operation.
Ensure the power conversion switch is in the
proper position for the required supply voltage.
All wiring must be completed prior to installing the
unit.
-
Electrical Connection
1. Loosen the screws securing junction box cover.
2. Remove knockouts in the box cover to use a cable
clamp.
3. Place the unit in position in the opening. Level it with
shims if necessary, and attach the unit to the frame
using the nailing flanges provided.
4. The unit is factory wired for 120 Volt power supply.
If 208/240 Volt operation is required, flip the switch
located on junction box and reconfigure the wiring
as covered on page 7. Wires L1, L2, N, and G are
located inside the junction box.
5. Wire a dedicated, properly fused, 20 Amp rated
circuit for appropriate voltage (120 or 208/240).
6. Place all connectors inside junction box and replace
the cover to ensure connections are tight.
-
10007572
3
TBREF Electric Fireplace
N
5/8" (16mm)
Recessed
Nailing Flange
G
H
Rough
Opening
Depth
L
Rough
Opening
Height
A
M
M
O
K Rough Opening Width
1/2" (13mm)
5/8" (16mm)
B
J
2"
(60mm)
3"
(95mm)
7"
(192mm)
E
F
D
E
C
Fireplace Dimensions
Fig. 1 Fireplace specifications and framing dimensions.
Ref. TBREF36/TBREF36NH
A 40" (1016mm)
B 36" (914mm)
C 36" (914mm)
D 21" (533mm)
E 7¹⁄₂" (191mm)
F 19
³⁄₄" (502mm)
G 14" (356mm)
H 27
Framing Dimensions
J 36¹⁄₂" (927mm)
K 41" (1041mm)
L 14" (356mm)
M 37¹⁄₂" (953mm)
N 54" 1372mm)
O 27" (686mm)
Electrical Specifications
Voltage: 120 Volt 120 Volt (NH) 240 Volt
Total Amps: 13 Amps 2 Amps 12.9 Amps
Total Watts: 1550 Watts 240 Watts 3100 Watts
Heater Rating: 1455 Watts N/A 2855 Watts
4
¹⁄₂" (698mm)
10007572
Mantels
J
F
G
H
I
O
N
M
L
K
ABC
D
E
V
W
X
Y
Z
The height that a combustible mantel is fitted above the
fireplace is dependent on the depth of the mantel. This
also applies to the distance between the mantel leg (if
fitted) and the fireplace.
For correct mounting height and width, refer to Figure
2a and 2b.
The distances and reference points are not affected by
the fitting of a bay window front trim kit.
Noncombustible mantels and legs may be installed at
any height and width around the appliance.
When using paint or lacquer to finish the mantel, such
paint or lacquer must be heat-resistant to prevent discoloration.
Mantel Clearances
TBREF Electric Fireplace
Black
Surround
Face
Mantel Leg
CFM164a
Side of Combustion
Chamber
Wall
Top of Combustion Chamber
Mantel Shelf Mantel from Top
Ref.
V 14" (356mm) A 25" (635mm)
W 12" (305mm) B 23" (584mm)
X 10" (254mm) C 21" (533mm)
Y 8" (203mm) D 19" (483mm)
Z 1
Fig. 2a Combustible mantel minimum installation.
Depth
¹⁄₂" (38mm) E 15" (381mm)
Ref.
of Comb. Chamber
CFM146b
CFM170
Mantel Mantel Leg from Side
Ref.
Leg Depth
Ref.
of Comb. Opening
F 14" (356mm) K 14" (356mm)
G 12" (305mm) L 12" (305mm)
H 10" (254mm) M 10" (254mm)
I 8" (203mm) N 8" (203mm)
J 1
Fig. 2b Combustible mantel leg minimum installation.
¹⁄₂" (38mm) O 1¹⁄₂" (38mm)
Framing
1. Choose fireplace location.
2. Place fireplace into position.
3. Frame in the fireplace with a header across the top.
It is important to allow for finished face when setting
the depth of the frame.
Four (4) nailing flanges are supplied with the fireplace
(found on the fireplace hearth). To level the box and
secure it firmly in place, remove the nailing flanges from
the hearth and install at the sides of the fireplace as
shown in Figure 3.
10007572
5
Loading...
+ 11 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.