Vermont Casting 7TDVP24, 7TDVP12, 7TDVP1218, 7TDVP3564, 7TDVP36 User Manual

...
Page 1
VENT SECTIONS and OFFSETTING ELBOWS
NOTE: THE INSTALLED LENGTH OF ANY VENTING SECTION IS 1
1/2
12 "
305mm
24"
610mm
36"
914mm
48"
1219mm
8"
203mm
7"
178mm
35"
889mm
64"
1626mm
10"
254mm
18"
457mm
9
1/4
"
7
1/4
"
9
1/4
"
90°
7"
13"
9
1/4
"
90
°
13"
7
1/ 4
"
13"
17
"
OFFSET
235mm
235mm
178mm
184mm
330mm
330mm
335mm
330mm
184mm
OFFSET w/2-90°
Back to Back
FIREPLACE FACTS
CONTEMPORARY TERMINATIONS
11"
7
3/8
"
45°
45°
7
3/8
"
OFFSET w/2-45°
Back to Back
45°
7
3/8
"
188mm
188mm
188mm
ELBOWS
7"
7"
32"
6
1/2
"
813mm
127mm
19"
16"
482mm
406mm
165 mm
5
"
TRIBUTE 36CDVXR REAR VENT GAS FIREPLACE
Page 2
9
1/4
"
7
1/4
"
9
1/4
"
90°
7"
13"
9
1/4
"
90
°
13"
7
1/ 4
"
13"
17
"
OFFSET
235mm
235mm
178mm
184mm
330mm
330mm
335mm
330mm
184mm
OFFSET w/2-90°
Back to Back
FIREPLACE FACTS
CONTEMPORARY TERMINATIONS
11"
7
3/8
"
45°
45°
7
3/8
"
OFFSET w/2-45°
Back to Back
45°
7
3/8
"
188mm
188mm
188mm
ELBOWS
7"
7"
32"
6
1/2
"
813mm
127mm
19"
16"
482mm
406mm
165 mm
5
"
13.25”
Tribute 36CDVXR
10.5”
9.75”
11.5”
7TDRVT
7TRVT
FEATURES:
• 36" Tribute Direct Vent Gas Appliance
• 14,700 to 21,000 BTU/hr. input
• 18" Gas Inlet Flex Line with Shut-Off Valve
• 2 Piece Log Set Fastened
• Embossed Refractory
• Attached 17' Low Voltage Wire Connected to Valve for Remote Operation Hook-Up
• Includes Electrical Recepticle
Accessories:
FK12 - Fan and Cord (160cfm) RC1/RC2 - Universal Remote Controls IMTFK - IMT Thermostat w/ Face Plate
Dedicated Tribute DV Venting Components:
7TCRVT - Rear Vent Kit includes: Rigid Flue Assembly, Hot Touch Termination which telescopes between 7" and 13" and Firestop 7TCDV45KT - Flex Pipe Assembly extends 13" to 32", Firestop & Termination (for 45º corner installation) 7TCDV90 - 90 Degree Elbow (unitized)
Bulk Flex Vent Kits*
7FDVCK - Bulk Flex Connector Kit(Includes: 10 4" Clamps and 10 7" Clamps to secure the flex vent to the fireplace and termination) 7FDVSPK - Bulk Flex Spacer Kit (Includes: 10 Spring Spacers) VSK7 - Vertical Vent Kit
BURNER SYSTEM:
• Capacity – Natural: 21,000 BTU/HR Max. 14,700 BTU/HR Min. – Propane: 21,000 BTU/HR Max. 15,750 BTU/HR Min.
• Fuel - Natural or Propane Gas
Clearance to Combustibles: Top of Unit to Ceiling 36” (914 mm) Front of Unit of Combustibles 36” (914 mm)
Appliance
Top 0” (0 mm) Bottom 0” (0 mm) Side 0” (0 mm) Back 0” (0 mm)
Venting
Concentric sections of DV Vent Top, bottom & sides 1” (25 mm)
NOTE: Hood must be permanently installed with three (3) sheet metal screws supplied in Fireplace. Gas Inlet and Manifold Pressures
Natural LP (Propane)
Inlet Minimum 5.5” w.c. 11.0” w.c. Inlet Maximum 14.0” w.c. 14.0” w.c. Manifold Pressure 3.5” w.c. 10.0” w.c.
REV. 10/07
Page 3
VENT SECTIONS and OFFSETTING ELBOWS
12 "
305mm
24"
610mm
36"
914mm
48"
1219mm
8"
203mm
7"
178mm
35"
889mm
64"
1626mm
10"
254mm
18"
457mm
9
1/4
"
7
1/4
"
9
1/4
"
90°
7"
13"
9
1/4
"
90
°
13"
7
1/ 4
"
13"
17
"
OFFSET
235mm
235mm
178mm
184mm
330mm
330mm
335mm
330mm
184mm
OFFSET w/2-90°
Back to Back
FIREPLACE FACTS
CONTEMPORARY TERMINATIONS
11"
7
3/8
"
45°
45°
7
3/8
"
OFFSET w/2-45°
Back to Back
45°
7
3/8
"
188mm
188mm
188mm
ELBOWS
7"
7"
32"
6
1/2
"
813mm
127mm
19"
16"
482mm
406mm
165 mm
5
"
FLUE SYSTEM
VERTICAL SIDEWALL INSTALLATION
FLUE SYSTEM
7” Coaxial Direct Vent System
SPECIFICATIONS:
• 7” O.D.
• 4” I.D.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL
a) Rear Wall Vent Applications 2” top, 1” Sides & Bottom b) Vertical Side Wall Applications 1” to All Sides c) Vertical thru the Roof Applications 1” to All Sides
Venting Opening for Combustible Wall
9 3/8”
(240mm)
9 3/8”
(240mm)
MINIMUM COMBUSTIBLE WALL/FLOOR OPENINGS
a) 9 3/8” W x 9 3/8” H for Rear Wall Vent Applications b) 9 3/8” W x 9 3/8” H for Vertical Side Wall/Vertical Applications
Fireplace Hearth
MAXIMUM INSTALLATION LENGTHS
a) Rear Wall Vent Applications
• 20” to 32” outside wall, and of vent outlet thru wall to be 27 1/4” up from floor, use 7TCDV45KT
• 7” to 13” straight out
• Corner Installation: 7TCDV45KT must be used. Vent outlet and thru wall must be 29 1/2” from floor
b) Vertical Side Wall Applications 20? (6 m) Horizontal Vent Length with 7.5’ (2.29 m) vertical rise *Refer to manual for alternative venting distance
Opening for Noncombustible Wall
7 1/2”
(190mm)
VERTICAL THRU THE ROOF APPLICATIONS
• 8’ (2.4 m) Minimum Vertical Rise
• 40’ (12 m) Maximum Vertical Rise
• 2 sets of 45° Elbows can be used in Vertical rise with 8’
maximum distance between elbows
• Two 90° elbows maximum for 10’ (3 m)
• Horizontal can be installed in Vertical Applications
*Maximum angular variation for Vertical Sidewall/Vertical Application in system is total of 270°
*Refer to installation manual for all venting restrictions with elbow use
V0584-100
TERMINATION CLEARANCES MINIMUM
a) Horizontal 12” (305 mm) above Grade Level 18” (458 mm) to Ventilated Soffit 12” (305 mm) to Unventilated Soffit 12” (305 mm) under veranda, porch, deck or balcony
b) Vertical 24” (610 mm) Above a Roof Surface and any other obstruction within a horizontal distance of 18” (458 mm)
*Refer to installation manual for more termination restrictions and clearance information
PRODUCT LISTING
36CDVXR Certified to - ANSI Z21.88-2005 / CSA 2.33-2005 Vented Gas Fireplace Heaters
This appliance may be installed in an aftermarket permanently located, manufactured home or mobile home, where not prohibited by local codes.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used. The CDVXR has been approved for mobile home installations.