FIREPLACE & VENTING SPECIFICATIONS
PERFECTVIEW 39LDVT TOP VENT
686mm
1095mm
1095mm
784mm
1546mm
939mm
870mm
1/4
235mm
419mm
172mm
406mm
889mm
1003mm
946mm
991mm
171mm
63/4”
171mm
584mm
143mm
202mm
302mm
VENT SECTIONS
7"
178m
8"
203mm
7
48"
1219mm
7TDVP4
12"
305mm
7TDVP1
36"
914mm
24"
610mm
7TDVP24 7TDVP3
TE: THE INSTALLED LENGTH OF ANY VENTING SECTION IS
LENGTH
EXCEPT FOR THE LAST SECTION INSTALLED.
18"
457mm
12"
305mm
7TDVP121
LESS THAN ITS TOTAL
64"
1626mm
889mm
7TDVP3
35"

9
1/4
"
7
1/4
"
9
1/4
"
90°
7
"
13"
9
1/4
"
90
°
13"
7
1/4
"
13"
17
"
OFFSET
235mm
235mm
178mm
184mm
330mm
330mm
335mm
330mm
184mm
OFFSET w/2-90°
Back to Back
FIREPLACE FACTS
• Capacity – Natural: 23,000 BTU/HR Max.
16,100 BTU/HR Min.
– Propane: 22,500 BTU/HR Max.
16,875 BTU/HR Min.
Natural Propane
Minimum Inlet Pressure 5.5” w.c. 11.0” w.c.
Maximum Inlet Pressure 14” w.c. 14.0” w.c.
Manifold Pressure 3.5” w.c. 10.0” w.c.
MINIMUM FLOOR AREA:
• 39” W X 16” D
HEARTH EXTENSION:
A Hearth Extension Is Recommended But Not Required
Mantel Depth
2”
4”
6”
8”
10”
Clearance From Top
of Combustion Chamber Opening
To Bottom of Mantel
9”
11”
13”
15”
17”
CONTEMPORARY TERMINATIONS
11"
7
3/8
"
45°
45°
7
3/8
"
OFFSET w/2-45°
Back to Back
45°
7
3/8
"
188mm
188mm
188mm
32"
6
1/2
"
813mm
127mm
19"
16"
482mm
406mm
165
mm
5
"
PerfectView 39LDVT
FEATURES:
• 39” PerfectView Direct Vent Gas Appliance
• 16,000 to 23,000 BTU/hr. input
• Patented Insta-Flame TM Ceramic Burner System with 4-piece
Split Oak Ceramic Fiber Log Set
• Tempered Glass Panel Assembly
• Adjustable Flame and Heat Output
• Wall Switch
• 18” Flex Connector with Shutoff and EB1 electrical box installed
• Wall Firestop, Zero Clearance Sleeve (Rear vent models only)
• Rated as Fireplace Heater (AFUE)
• Uses 4”/7” Majestic (Direct Vent) Venting Components
BURNER SYSTEM:
• Fuel - Natural or Propane Gas
• Ignition System - Standing Pilot With Piezo Ignitor, A Low Voltage,
Self-Generating Power Pile System (mV)
– No Outside Electrical Power Needed OR
- Electronic ignition that requires 120 VAC Electrical hook up.
• Gas Supply Line - Consult Gas Code Book for Correct Sizing
ACCESSORIES:
39LDVCR - 39” LDV Ceramic Refractory
FK12 - Fan and Cord (160cfm) (for RN/RP only)
FK24 - Variable Speed Heat-Activated Fan Kit
IMTFK - IMT Thermostat w/ Face Plate
Minimum Mantel Clearances
The Fireplace Facts Information Sheets are for
quick reference only and are subject to change without notice. Actual fi replace instructions must abide
by specifi cations provided with each product.
REV. 10/07

9LDVT
OPTIONAL ACCESSORIES (Continued):
(Trim Kits continued from second page)
• Louver Kits - Additional Louver Kits ( To replace all louvers in
desired color, 4 sets are required ) See Price List
FLUE SYSTEM
7” Coaxial Direct Vent Syste
IFICATION
• 7” O.D
”
•
• Filligree Louver Kits - See Price List
• Perimeter Trim Kits - See Price List
• Face Trim Kits - See Price List
Vent Opening for Combustible Wall
9³⁄₈"
(240 mm)
9³⁄₈"
(240 mm)
Fireplace Hearth
Opening for Non-combustible Wall
Rnd.
7¹⁄₂" Dia.
(190 mm)
Framing Detail
VO584-100
INIMUM CLEARANCE TO COMBUSTIBLE MATERIAL
Rear Wall Vent Applications 2” top, 1” Sides & Botto
b) Vertical Side Wall Applications 1” to All Side
) Vertical thru the Roof Applications 1” to All Sides
INIMUM COMBUSTIBLE WALL/FLOOR OPENING
) 9 3/8” x 10 3/8” H for Rear Wall Vent Applications
b) 9 3/8” W x 9 3/8” H for Vertical Side Wall/Vertical Ap
plications
AXIMUM INSTALLATION LENGTHS
) Rear Wall Vent Applications
20” (508mm) Vent Length
0” (508mm) Vent Length with one 45° elbo
b) Vertical Side Wall Applications
36” (914 mm) Horizontal Vent Length with 90°
elbow installed directly on top of the unit
20ʼ (6 m) Horizontal Vent Length with
7.5ʼ (2.29 m) vertical rise
*Refer to manual for alternative venting distanc
ERTICAL THRU THE ROOF APPLICATIONS
8ʼ (2.4 m) Minimum Vertical Rise
40ʼ (12 m) Maximum Vertical Rise
2 sets of 45° Elbows can be used in Vertical rise
with 8ʼ maximum distance between elbows
Two 90° elbows maximum for 10ʼ (3 m)
Horizontal can be installed in Vertical
Applications
*Maximum angular variation for Vertical Sidewall/Vertical
Application in system is total of 270°
*Refer to installation manual for all venting restrictions
with elbow use
ERMINATION CLEARANCES MINIMUM
) Horizontal
12” (305 mm) above Grade Level
18” (458 mm) to Ventilated Soffi t
12” (305 mm) to Unventilated Soffi t
12” (305 mm) under veranda, porch, deck or balcony
b) Vertical
24” (610 mm) Above a Roof Surface and any other
obstruction within a horizontal distance
of 18” (458 mm)
*Re
er to installation manual for more termination
estrictions and clearance informatio
PRODUCT LISTING
NSI Z21.88 - 2005/CSA 2.332005
Vented Gas Fire
This
as appliance should be installed by qualifi ed
installers in accor
nd the current National Fuel Gas code ANSI Z223.1
or
A B 149.1 Installation code for Gas Burning
ppliance and Equipment
lace Heaters
ance with local building codes
I
G
S
E
N
D
C
E
D
R
E
I
T
F
I
Rev. 09/06