Installation and user manual
-9-
E. F.A.Q.
Error messages
-OC: no connection with temperature probe.
-SC: Short-circuit at temperature probe.
-Err: Relay or Triac in short-circuit.
-Err2: Overload (power limit exceeded).
-Err3: No load (or very low load, below 100W, check the connection to the radiators).
-Err4: Temperature limit exceeded (>90ºC in the electronics).
F. ECO DESIGN
Item Unit
Type of heat output/room temperature control
(select one)
Single stage heat output and no
room temperature control
no
Two or more manual stages, no room
temperature control
no
With mechanic thermostat room tem-
perature control
no
With electronic room temperature
control
no
Electronic room temperature control
plus day timer
no
Electronic room temperature control
plus week timer
yes
Other control options (multiple selections pos-
sible)
Room temperature control, with pre-
sence detection
no
Room temperature control, with open
window detection
yes
With distance control option yes
With adaptative start control yes
With working time limitation yes
With black bulb sensor no
Contact information: see back cover
Information common to all radiators:
Data
Value
EcoWi
Item Simbol Unit 750W 1.000W 1.500W 2.000W
Heat output
Nominal heat output P
nom
kW 0,75 1 1,5 2
Minimum heat output (indicative) P
min
kW 0 0 0 0
Maximum continuous heat output P
max,c
kW 0,75 1 1,5 2
Auxiliary electricity consumption
At nominal heat output el
max
kW 0,75 1 1,5 2
At minimum heat output el
min
kW 0 0 0 0
In standby mode el
SB
kW
0,00095 0,00095 0,00095 0,00095