Setpoint Devices | Fancoil Unit Thermostat Retrofit Solution
VTR83X0A5X SERIES/
VC3XXXE5000
Network Ready, BACnet MS/TP,
and Wireless Models Available
VTR83x0A5x
VC3xxxE5000
This two component retrofit option consists of the VTR8300 terminal
equipment controller and the VC3000 relay pack. Together, they provide
an easy solution for retrofitting fan coil unit thermostats without
requiring upgrades to other components such as relays, transformers,
controllers, sensors, and network wiring. Existing line voltage wiring
between the fan coil unit and temperature controller can be reused,
further minimizing overall labor and installation costs.
The VC3000 relay pack features an onboard universal voltage power
supply and line-voltage relays that directly drive fractional horsepower
fan motors and valves. The VTR8300 controller features a fully digital
multi-language touch screen display that can be user customized.
The controller’s built-in commissioning and configuration utility, its
temperature sensor, and the optional humidity and occupancy sensor,
provide maximum flexibility. The VTR8300 controller is available in
Network Ready, BACnet® MS/TP or wireless ZigBee® networked models.
SPECIFICATIONS
VTR83x0A5x Series/VC3xxxE5000
Thermostat Power
Requirements
Operating Conditions 0 to 50 °C (32 to 122 °F); 0 to 95% RH
Storage Conditions -30 to 50 °C (-22 to 122 °F); 0 to 95% RH
Temperature Sensor Local 10k NTC type 2 thermistor
Temp. Sensor Resolution ± 0.1 °C (± 0.2 °F)
Temp. Control Accuracy ±0.5 °C (±0.9 °F ) @ 21 °C (70 °F) typical
Humidity Sensor and
Calibration
Humidity Sensor Precision Reading range from 10 to 90% RH non-
7 Vdc, 2.4 W min. (from VC3000)
non-condensing
non-condensing
calibrated
Single point calibrated bulk polymer sensor
condensing 10 to 20% precision is 10%;
20 to 80% precision is 5%;
80 to 90% precision is 10%
Commercial and
hospitality
Suitable for both commercial and
hospitality markets and systems
(VTR8300 Series)
Digital touch
screen
Customizable color digital
touch screen interface with
multi-language support
(VTR8300 Series)
7-day occupancy
scheduling
2 to 4 events (VTR8300 Series)
Humidity Sensor Stability <1.0% annual drift (typical)
Dehumidification Setpoint
Range
Occupied and Unoccupied
Setpoint Range Cooling
Occupied and Unoccupied
Setpoint Range Heating
Room and Outdoor Air
Temperature Display
Proportional Band for Room
Temperature Range Control
Binary Inputs Dry contact across terminal BI1, BI2 & UI3
Economizer Analog Output
Rating
Economizer Analog Output
Accuracy
Wire Gauge 18 gauge maximum, 22 gauge
WARRANTY
Limited Warranty 18 months
AGENCY APPROVALS
*
*The CE mark indicates RoHS2 compliance.
UL: 61010-1 (2nd edition); CSA: 61010-1 (3rd edition); IEC: 61010-1 (3rd edition), EN 60950-1:
2006A2: 2013, UL 873, CSA 22.2 No. 24-93; 61326-1:2005; FCC: Part 15, Subpar t B; CE: EMC
Directive 2004/108/EC (European Union); wireless models: FCC
Part 15, Subpart C; R&TTE Directive 1999/5/EC; EN: 301 489-1 V1.9.2, 301 328 V1.8.1; RSS 210
Extremely
compact design
(VC3000 Series)
90 to 277 Vac
Line powered from 90 to 277 Vac,
50 to 60 Hz (VC3000 Series)
Wire-leads
Wire-leads for line-voltage
connections (VC3000 Series)
30 to 95% RH
12 to 38 °C (54 to 100 °F)
5 to 32 °C (40 to 90 °F)
-40 to 50 °C (-40 to 122 °F)
Cooling & Heating: 1.8 °C (3.2 °F )
to Scom
0 to 10 Vdc into 2k Ω resistance min.
±3% typical
recommended
800.354.8556 | +1 503.598.4564 | sales@veris.com | intl@veris.com | www.veris.com
TM
HQ0004955.E 0117
Setpoint Devices | VTR83x0A5x Series/ VC3xxxE5000Setpoint Devices | Fancoil Unit Thermostat Retrofit Solution
WALL CONTROLLERS
Ordering Information
MANUF. PART # ORDERING # DESCRIPTION COMM.
VTR8300A5000B U025-0002
VTR8300A5000P U025-0003 Wireless (Zigbee)
VTR8300A5500B U025-0005
VTR8300A5500P U025-0006 Wireless (Zigbee)
VTR8350A5000B U025-0008
VTR8350A5000P U025-0009 Wireless (Zigbee)
VTR8350A5500B U025- 0011
VTR8350A5500P U025- 0012 Wireless (Zigbee)
Fancoil Terminal Equipment
Controller, PIR ready (PIR cover
not included)
Fancoil Terminal Equipment
Controller, PIR factory equipped
Fancoil Terminal Equipment
Controller, PIR ready (PIR
cover not included), onboard
humidity sensor
Fancoil Terminal Equipment
Controller, PIR factory
equipped, onboard humidity
sensor
BACnet
BACnet
BACnet
BACnet
RELAY PAC K S
Ordering Information
MANUF. PART # ORDERING # DESCRIPTION
VC3500E5000 U025- 0013 Transformer relay pack, 5 relay fan outputs
VC3504E5000 U025 -0014
VC3514E5000 U 025-0015
VC3400E5000 U025- 0016
VC3404E5000 U0 25- 0017
VC3300E5000 U02 5-0018 Transformer relay pack, 3 slave fan outputs
Transformer relay pack, 5 relay fan outputs and
4 outputs
Transformer relay pack, 5 relay fan outputs, smart
Vdc OCC output, and 4 inputs
Transformer relay pack, 4 relay fan outputs and
smart Vdc output
Transformer relay pack, 4 relay fan outputs, smart
Vdc output, and 4 inputs
WIRING EXAMPLES
Filter
lter status switch
3-Speed Fan
fan status switch
Cooling Coil
Heating Coil
DIMENSIONAL DRAWING
VC3504E5000
VTR8300
APPLICATIONS
Wall Control and Relay Pack Applications (BACnet models shown, wireless similar)
Application
2 or 4 pipe,
up to 3 speed
fan, humidity
control
2 pipe, up to
3 speed fan
2 or 4 pipe,
up to 3 speed
fan, humidity
control
2 pipe, up to
3 speed fan
Slave fan
control only
Outputs/
Inputs
1H/1C with
reheat
1H/1C with
4 inputs and
reheat
1H/1C with 4
inputs, reheat,
and occ. output
1H/1C with
pulsed reheat
1H/1C with
4 inputs and
pulsed reheat
1H/1C with
reheat
1H/1C with
4 inputs and
reheat
1H/1C with 4
inputs, reheat,
and occ. output
1H/1C with
pulsed reheat
1H/1C with
4 inputs and
pulsed reheat
3 fan outputs VTR8300A5000B U025- 0002 VC3300E5000 U025 -0018
Controller
Manuf. Part #
VTR8350A5000B U025-0008 VC3500E5000 U 025 - 0013
VTR8350A5000B U025-0008 VC3504E5000 U025 -0014
VTR8350A5000B U025-0008 VC3514E5000 U 025- 0015
VTR8300A5000B U025- 0002 VC3500E5000 U025-0013
VTR8300A5000B U025- 0002 VC3504E5000 U025-0014
VTR8350A5000B U025-0008 VC3500E5000 U 025 - 0013
VTR8350A5000B U025-0008 VC3504E5000 U025 -0014
VTR8350A5000B U025-0008 VC3514E5000 U 025- 0015
VTR8300A5000B U025- 0002 VC3500E5000 U025-0013
VTR8300A5000B U025- 0002 VC3504E5000 U025-0014
Controller
Ordering #
Relay
Pack Manuf.
Part #
Relay
Pack
Ordering #
4.7”
(120 mm)
3.4”
(86 mm)
1.0”
(25 mm)
HQ0004955.E 0117
800.354.8556 | +1 503.598.4564 | sales@veris.com | intl@veris.com | www.veris.com