Veris Industries HX23 SERIES Data Sheet

SENSOR OUTPUT
Selected Range
0 V
0 A
10 V
SENSED AMPS
Minimize Installed Cost
Current Monitoring | Current Transducers:
0 to 10 Vdc Analog Output
HX23 SERIES
Load Trending with 0 to 10 Vdc Output
H723
H923
H623-xx
TM
Maximize Reliability
The Hawkeye 623-xx, 723LC, 723HC, and 923 Series provide accurate load trending information with a proportional 0 to 10 Vdc output signal. Devices offer three amperage range options, with slide-switch selection for easy field adjustment – no need for jumpers.
Self-powered analog
Self-powered analog current transducer 0 to 10 Vdc output
Retrofit
Self-gripping, split-core design for fast retrofit installation…no need to remove conductor (H623-xx and H923)
No jumpers
No jumpers on unit…reduces installation error
APPLICATIONS
• Load trending
• Motor control
• Fan/pump status
No external power required
No external power required for sensor
Factory calibrated
Factory calibrated ranges for high resolution and installation ease
Field-selectable ranges
Some models available with field­selectable ranges
EXAMPLE LINEAR OUTPUT
Scale software as shown
SPECIFICATIONS
Sensor Power Induced from monitored current
Insulation Class
Frequency Range 50/60 Hz nominal
Temperature Range -15 to 60 °C (5 to 140 °F)
Humidity Range 10 to 90% RH, non-condensing
Accuracy ±2% F.S. from 10% to 100% (range)
Terminal Block Wire Size
Terminal Block Torque 3.5 to 4.4 in-lbs (0.4 to 0.5 N-m)
WARRANTY
Limited Warranty 5 years
AGENCY APPROVALS
Agency Approvals
1. The CE mark indicates RoHS2 compliance. Please refer to the CE Declaration of Conformity for additional details.
600 Vac RMS (UL) (H623-xx) 300 Vac RMS (CE) (H623-xx , H723, H923)
24 to 14 AWG (0.2 to 2.1 mm2)
UL 508 open device listing (H623-xx only); CE1: EN61010-1, CAT III, Pollution Degree 2, basic insulation
TM
HQ0001765.G 0117
Current Monitoring | Hx23 Series
H623-XX
Dimensional Drawing
2.1"
(54 mm)
0.4” x 0.2”
(10 mm x 5 mm)
Slot (2x)
H923
Dimensional Drawing
3.1”**
(79 mm)
Ø 0.3”
(8 mm)
Removable Mounting Bracket
0.6"
(16 mm)
Removable Mounting Bracket
1.1”
(26 mm)
0.5"
(13 mm)
(74 mm)
(89 mm)
(21 mm)
(70 mm)
3.0”
(76 mm)
2.1"
(54 mm)
2.9"
3.5"
0.8”
2.8”
2.5”
(64 mm)
0.7"
(18 mm)
1.0”
(25 mm)
1.2"
(31 mm)
Self-gripping Iris
1.4”*
(36 mm)
2.5"
(64 mm)
1.0"
(26 mm)
Bracket can be mounted on three sides for added installation flexibility.
H723LC/H723HC
Dimensional Drawing
Removable/Adjustable Mounting Bracket
0.9"
 0.7"
(19 mm)
(23 mm)
3.0" **
(75 mm)
0.2” x 0.15” slot (2x)
2.8"
(68 mm)
1.1" *
(27 mm)
3.8"
(95 mm)
4.2"
(106 mm)
* Terminal block may extend up to 1/8” over the height dimensions shown. ** Slide switch may extend up to 1/4” over the height dimensions shown.
MONITORING FAN/PUMP MOTORS FOR POSITIVE PROOF OF FLOW
Wiring Diagram
CONTACTOR
CONTROLLER
AI
COMMON
0 to 10 Vdc
+
Fan or Pump
* Terminal block may extend up to 1/8” over the height dimensions shown. ** Slide switch may extend up to 1/4” over the height dimensions shown.
ORDERING INFORMATION
MODEL AMPERAGE RANGE SENSOR OUTPUT HOUSING UL CE
H623-10 0 to 10 A
H623-20 0 to 20 A Split-core
H723LC 0 to 10/20/40 A Solid-core
0 to 10 Vdc
H723HC 0 to 50/100/200 A Solid-core
H923 0 to 20/100/150 A Split-core
HQ0001765.G 0117
TM
Split-core
Loading...