![](/html/a2/a227/a227dca3c85051b755fb0522bd1c198609a1c30b0abf1a43bdc928dc28558de6/bg1.png)
Current Monitoring | Adjustable Trip Point, High Voltage Output
HX09 SERIES
Detect Belt Loss, Coupling Shear,
and Mechanical Failure
H709
H809
Maximize Reliability
Minimize Installed Cost
H609
H909
Low setpoint
The H809 has a low (0.75 A)
minimum setpoint…no need for
multiple wraps of the conductor
through the sensor, even on loads
as small as 1/5 HP
Small in size
H609 and H809 are small in size
to fit easily inside small starter
enclosures
Versatility
Removable mounting bracket
optimizes field versatility
APPLICATIONS
• Detecting belt loss, coupling
shear, mechanical failure, and
interlocking loads
• Verifying lighting circuit and
other electrical service run
times
Adjustable trip
point
Precise current trip point setting
Status LEDs
For easy setup and local
indication
Flexibility
Bracket on H909 can be installed
in three different configurations
• Monitoring status of industrial
process equipment
• Monitoring status of critical
motors (compressor, fuel, etc.)
• VFD output On/Off status
• Fan/pump status monitoring
Hawkeye x09 Series are high performance current switches, ideal for line
voltage loads. The devices are powered by the current being monitored.
They are ideal for monitoring performance on unit vents, exhaust fans,
recirculation pumps, and other fixed loads.
Sensor Power Induced from monitored conductor
Insulation Class 600 Vac RMS (UL), 300 Vac RMS (CE1)
Frequency Range 50/60 Hz
Temperature Range -15 to 60 °C (5 to 140 °F)
Humidity Range 10 to 90% RH non-condensing
Hysteresis 10% (typical)
Terminal Block Wire Size 24 to 14 AWG (0.2 to 2.1 mm2)
Terminal Block Torque 3.5 to 4.4 in-lbs (0.4 to 0.5 N-m)
WARRANTY
Limited Warranty 5 years
AGENCY APPROVALS
Agency Approvals UL 508 open device listing; CE: EN61010-1,
CAT III, Pollution Degree 2, basic insulation
DETECTS BELT LOSS/COUPLING SHEAR!
DETECTS BELT LOSS/COUPLING SHEAR!
Fan/pump
Calibrated
Trip Point
O O
Now you can easily detect when drive belts slip, break, or pump couplings shear.
In fact, a typical HVAC motor that loses its load has a reduction of current draw
of up to 50%. That’s why our sensors are the industry standard for status.
1. The CE mark indicates RoHS2 compliance. Please refer to the CE Declaration of
Conformity for additional details.
Note: Do not use the LED status indicators as evidence of applied voltage.
If using this switch in an application that includes an electronically commutated motor
(ECM), see Veris Application Note VN61, at www.veris.com.
Loss of Belt/Coupling Shear
On
Electrical
Failure
TM
HQ0001755.G 0117
![](/html/a2/a227/a227dca3c85051b755fb0522bd1c198609a1c30b0abf1a43bdc928dc28558de6/bg2.png)
Current Monitoring | Hx09 Series
H609
Dimensional Drawing
Removable Mounting Bracket
0.6"
(16 mm)
2.1"
(54 mm)
0.4” x 0.2”
(10 mm x 5 mm)
Slot (2x)
H709/H709HV
Dimensional Drawing
Removable/Adjustable Mounting Bracket
0.7"
(19 mm)
0.5"
(13 mm)
2.1"
(54 mm)
2.9"
(74 mm)
0.7"
(18 mm)
3.5"
(89 mm)
1.2"
(31 mm)
Self-gripping Iris
0.9"
(23 mm)
2.5" *
(64 mm)
1.0"
(26 mm)
3.0" **
(75 mm)
H809
Dimensional Drawing
Removable/Adjustable Mounting Bracket
0.7"
(18 mm)
0.4” x 0.2”
Slot (x2)
H909/H909HV
Dimensional Drawing
Removable Mounting Bracket
1.1”
(26 mm)
3.1”**
(79 mm)
1.7
(43 mm)
2.3"
(58 mm)
0.8”
(21 mm)
1.0”
(25 mm)
0.9"
(23 mm)
1.1" *
(27 mm)
2.8" *
(71 mm)
Bracket can
be mounted
on three sides
for added
installation
flexibility.
MONITORING FAN /PUMP MOTORS
FOR POSITIVE PROOF OF FLOW
Wiring Diagram
CONTACTOR
9
Motor
CONTROLLER
Digital
Input
Fan or Pump
Self-gripping Iris
4.2"
(106 mm)
2.8"
(68 mm)
3.8"
(95 mm)
1.1" *
(27 mm)
Ø 0.3”
(8 mm)
(70 mm)
3.0”
(76 mm)
2.8”
2.5”
(64 mm)
1.4”*
(36 mm)
0.2” x 0.15”
slot (2x)
* Terminal block may extend up to 1/8” over the height dimensions shown.
** Slide switch may extend up to 1/4” over the height dimensions shown.
ORDERING INFORMATION
MODEL
H609 1.25 to 50 A N.O. 0.2 A @ 120 Vac/dc 1.25 A or less • Split-core
H709 1 to 135 A N.O. 0.2 A @ 120 Vac/dc 1.0 A or less • Solid-core •
H709HV 1 to 135 A N.O. 1.0 A @ 250 Vac 1.0 A or less Solid-core
H809 0.75 to 50 A N.O. 0.2A @ 120 Vac/dc 0.75 A or less
H909 2.5 to 135 A N.O. 0.2 A @ 120 Vac/dc 2.5 A or less • Split-core •
H909HV 2.5 to 135 A N.O. 1.0A @ 250 Vac 2.5 A or less Split-core
1. Listed for use on 75°C insulated conductors.
AMPERAGE RANGE
@ 50/60 H Z ONLY
STATUS OUTPUT
(MAX.)
MIN. TRIP
POINT
STAT US
LED
• Solid-core
HOUSING UL CE
LEAD
FREE
1
•
1
•
•
•
•
•
HQ0001755.G 0117
TM