Veris Industries 228PV SERIES, 735 SERIES, 4000 SERIES Data Sheet

Flow Monitoring | Tee Meter, Plastic
228PV, 735 & 4000 SERIES
For Pipe Sizes ½” To 4”
228PV Series
735 Series
4000 Series
Plastic tee-style flow sensor for plastic pipe or corosive applications. Use in conjunction with flow monitor or transmitter for a complete flow monitoring system.
Corrosion & impact resistant
Glass filled PPS plastic electronics housing (228PV)
Durable & reliable
Tungsten carbide impeller shaft (228PV)
Budget friendly
Cost effective for tight budgets (735 Series)
Wide flow rate range
Handles flow rates from 2 ft/sec to 20 ft/sec (735 Series)
Low flow accuracy
measure flow rates as low as
0.25 ft/sec (4000 Series)
4-20 mA output
4 to 20 mA output, programmable in the field for compatibility with standard control systems (4000 Series)
SPECIFICATIONS
228PV Series
Flow Range 0.5 to 30 ft/sec
Operating Temp Range 0 to 60 °C (32 to 140 °F)
Operating Pressure Range Up to 25 °C (77 °F): 100 psi; from 25 to
Accuracy ±1.0% of full scale over recommended
Repeatability ±0.3% of full scale over recommended
Linearity ±0.2% of full scale over recommended
Output Frequency 3.2 to 200 Hz, 5 ms ± 25% output pulse
735 Series
Flow Range 2 to 20 ft/sec
Operating Temperature/Pressure Range
Accuracy ±3.0% of full scale over recommended
Repeatability ±1.5% of full scale over recommended
Linearity ±1.5% of full scale over recommended
Output Frequency 3.2 to 200 Hz, 5 ms ± 25% output pulse
60 °C (77 to 140 °F): pressure decreases linearly with increasing temperature; at 60 °C (140 °F): 40 psi
flow range
flow range
flow range
width
150 psig @ 22 °C (73 °F); 75 psig @ 38 °C (110 °F)
flow range
flow range
flow range
width
4000 Series
Flow Range Design range: 1 to 20 ft/sec;
Low flow: Flow range 0.25 to 20 ft/sec
Max. Operating Temperature PVC: 60 °C (140 °F);
PVDF: 104 °C (220 °F)
Max. Operating Pressure PVC: 350 psi @ 60 °C (140 °F);
PVDF: 275 psi @ 105 °C (220 °F)
Accuracy <1%
Repeatability ±0.5%
Output Pulse, factor calibration or 4 to 20 mA
analog (requires A302 programming cable)
WARRANTY
Limited Warranty 1 year
TM
HQ0001782.F 0117
Flow Monitoring | 228PV, 735 & 4000 Series
228PV SERIES
Dimensional Drawing
228PV1505 A = 5.0” (127 mm) B = 5.2” (131 mm) C = 2.4” (61 mm) D = 4.0” (102 mm) E = 5.0” (127 mm)
4000 SERIES
Dimensional Drawing
735 SERIES
Dimensional Drawing
(minimum clearance for sensor removal)
E
D
B
C
A
228PV3005 A = 6.5” (165 mm) B = 6.9” (173 mm) C = 4.3” (107 mm) D = 4.7” (119 mm) E = 5.0” (127 mm)
228PV4005 A = 7.4” (187 mm) B = 6.9” (199 mm) C = 5.4” (137 mm) D = 5.1” (130 mm) E = 5.0” (127 mm)
2.2”
(55 mm)
3.5”
(89 mm)
B
A
735PV0506
A = 0.5” (13 mm) B = 0.9” (23 mm) C = 3.9” (98 mm) D = 3.1” (78 mm) E = 4.0” (107 mm)
(minimum clearance for sensor removal)
E
C
D
735PV0706
A = 0.75” (19 mm) B = 1.1” (27 mm) C = 3.9” (98 mm) D = 3.3” (84 mm) E = 4.0” (107 mm)
735PV1006
A = 1.0” (26 mm) B = 1.3” (34 mm) C = 3.9” (98 mm) D = 3.5” (89 mm) E = 4.0” (107 mm)
A
B
3.6”
(91 mm)
400210-0021
A = 8.7” ± 0.25“ (222 mm ± 7 mm) B = 4.4” (105 mm)
411210-0021 A = 10.6” ± 0.25“ (268 mm ± 7 mm) B = 4.7” (119 mm)
402210-0021
A = 13.1” ± 0.25“ (332 mm ± 7 mm) B = 5.4” (137 mm)
ORDERING INFORMATION
MODEL MANUF. PART # DESCRIPTION
U001-0032 402210-0 021 Flow, Sensor, Pure H2O, PVC80, 1”, 4 to 20 mA
U001-0033 411210- 0021 Flow, Sensor, Pure H2O, PVC80, 3/4”, 4 to 20 mA
U001-0034 400210-0021 Flow, Sensor, Pure H2O, PVC80, 1/2”, 4 to 20 mA
U001-0036 228PV1505-1211 Flow, Sensor, Insert, 1-1/2” PVC Tee
U001-0040 228 PV 30 05 -1211 Flow, Sensor, Insert, 3” PVC Tee
U001-0041 228 PV4005-1211 Flow, Sensor, Insert, 4” PVC Tee
U001-0046 735PV0506-1201 Flow, Sensor, 1/2”, PVC, Tee, Pulse, IR, Sch40
U001-0047 735PV0706-1201 Flow, Sensor, 3/4”, PVC, Tee, Pulse, IR, Sch40
U001-0048 735PV1006-1201 Flow, Sensor, 1”, PVC, Tee, Pulse, IR, Sch40
U001-0049 401210-0021 Flow, Sensor, Ln, Pure H2O, PVC80, 3/4”, 4 to 20 mA
U001-0020 A301-20 Programming Cable with CD for Analog/Modbus/BACnet/LonWorks Outputs, Serial PC Connector
HQ0001782.F 0117
TM