Veris TI Series, TIG, TID, TIW, TIH Installation Manual

VERIS INDUSTRIES
environmental SenSorS
inStallation GUiDe
TI SerIeS TI SerIeS
TID
TIW
Product IdentIfIcatIon
Immersion Probe
Enclosure
T I
D = Duct G = Servi ce Entry Body H = Threade d NPT Only W = Water resis tant housing
Length “L”
A = 2 1/2" (64mm) B = 4" (102mm) C = 6" (152mm) D = 8" (203mm) E = 12” (305mm)
Thermowell Sizing
Probe Length Thermowe ll Length
A (2 1/2") (64mm) 1 1/2” (38mm) B (4") (102mm) 3” (76mm) C (6") (152mm) 5” (127mm) D (8") (203mm) 7” (178mm) E (12”) (305mm) 11” (279mm)
Thermowell Sensor Type
0 = None 1 = Add Therm owell
TIG
TIH
B = 100R Platinu m, RTD C = 1k Platinum, RTD D = 10k T2, Therm istor E = 2.2k, Ther mistor F = 3k, Therm istor G = 10k CPC, Ther mistor H = 10k, T3, Ther mistor J = 10k Dale, Ther mistor K = 10k w/11k shunt,Thermistor M = 20k NTC, Ther mistor N = 1800 ohm, Ther mistor P = 10mV/°C, Linitemp R = 10k US, Thermis tor S = 10k 3A221, Thermis tor T = 100k, The rmistor U = 20k “D”, Thermis tor
Immersion Temperature Sensors
Installer’s Specifications
Wiring 22AWG; 2-wire:RTD Thermistor, 4-20mA; 3-wire: Voltage output models Probe Stainless Steel Test Pressure 200psi
Linitemp:
Input Power 5 to 30VDC Output 1µA/°C or 10mV/°C Operating Temperature -25° to 105°C (-13° to 221°F) Accuracy C alibration Error: 1.5°C (35°F) typic al; 2.5°C (37°F) max. at 25°C (77°F )* Error over Temperature: 1.8°C typical (35°F); 3.0°C (34°F) max. over 0° to 70°C (32° to 158°F) range
2.0°C (35°F) t ypical, 3.5°C (38°F) max. over -25° to 105°C (-13° to 221°F) range
*Room temperature error do cumented on each unit.
quIck Install
Thread assembly into a pipe fitting.1.
Wire as shown (see Wiring sec tion).2.
Options
Cal Certificate
0 = None 1 = 1 point Cal v alidation 2 = 2 point Cal v alidation
Threads
Blank = NPT A = BSPT B = DIN 2999
Z205466-0E PAGE 1 ©2009 Veris Industries USA 800.354.8556 or +1(0)503.598.4564 / support@veris.com 10091
Alta Labs, Enercep t, Enspector, Hawkeye, Trustat, Veris, and the Veris ‘ V’ logo are trademark s or registered tradema rks of Veris Industries, L.L .C. in the USA and/or othe r countries.
VERIS INDUSTRIES
dImensIons
1.5" (38 mm)
0.25"Dia. (6.3 mm)
L
1/2" NPT Standard
L
L
0.25" dia. (6.3mm)
Overall: "L" + 2" (50.8mm)
0.375" dia. (10mm)
Overall: "L" + 1.75" (45mm)
Immersion Probes
Thermowells
4"
(102 mm)
2.2"
(56 mm)
0.25" dia" (6.3mm)
L
0.5" nom. (13 mm)
CONTROLLER
TEMP SENSOR
+15v
Analog IN
Common
CONTROLLER
TEMP SENSOR
+15v
Analog IN
Common
4.5"
(114 mm)
2.8"
(71 mm)
0.25" dia" (6.3mm)
L
1.5"
(38 mm)
1/2" NPT Standard
TIG Model
TIH Model
ti SerieS
inStallation GUiDe
TIW Model
TID Model
Z205466-0E PAGE 2 ©2009 Veris Industries USA 800.354.8556 or +1(0)503.598.4564 / support@veris.com 100 91
Alta Labs, Enercep t, Enspector, Hawkeye, Trustat, Veris, and the Veris ‘ V’ logo are trademark s or registered tradema rks of Veris Industries, L.L .C. in the USA and/or othe r countries.
WIrIng
Thermistor
RTD
Linitemp
NOTE: All linitemp units are standard 3-wire 10m V/C. For 1µ A/C (2-wire) connect +15V (orange) and (white) signal wire. The (blue) wire is not connected.
Orange
Orange
ORANGE V+ (15V) WHITE SIGNAL BLUE COMMON/GND
3-Wire 10m V/C
ORANGE V+ (15V)
WHITE (SIGNAL )
BLUE (COMMON/GND)
2-Wire 1µ A/C
ORANGE V+ (15V)
WHITE (SIGNAL )
BLUE (NO CONNECT)