HxxV, HxxVB, & HxxVBSSERIES
Power Meter for Voltage-Mode CTs
VERIS INDUSTRIES
Maximize System Efficiency and
Gain Precise Power Quality with
1% Energy and Power Accuracy
DESCRIPTION
The H84xxV, H84xxVB, and H84xxVBS Series digital power meters deliver high
accuracy and high value at a competitive price.
Whether you are looking for a 1-phase pulse output meter to monitor kWh, or a
3-phase communicating meter to monitor THD, the H84xxV Series has the right
meter for you, in panel and wall mounting styles for your convenience.
The pulse output unit oers two pulse outputs. While kWh is standard, the second
pulse output provides a eld-selectable choice between phase loss or kVARh.
The Modbus communications unit oers a choice between two data outputs, Full
Data Set (FDS) or Extended Data Set (EDS). Data points are listed on the next page.
power/energy monitoring
APPLICATIONS
● Energy management and performance contrac ting
● Submetering for commercial tenants
● Activity-based costing in commercial and industrial facilities
BACne t
connectivity
via new
E8950
Gat e way
H84xx
H84xxVBS
FEATURES
● Revenue Grade measurements
● Intuitive navigation with context-sensitive menus for easy use
● Panel, wall, DIN rail mount...provide mounting exibility
● Digital power meters automatically detect and correct phase reversal,
eliminating the need to be concerned with CT load orientation...fast,
trouble-free installation
● Real-time power monitoring via local display or through control/data
acquisition systems
● Large, easy-to-read display
● Multiple values displayed at the same time on an anti-glare display
featuring a green back-light
SPECIFICATIONS
Inputs:
Control Power 100 to 415 ± 10%VAC, 5VA, 45-60 Hz
DC 125 to 250VDC ± 20%VDC, 3W *
Voltage Input UL: 600VAC; CE: 300VAC (L-N)
Current Input
CT Scaling Primary: Adjustable f rom 5A to 32,767A
Measurement Input Range 1V RMS full scale (+20% over-range)
Accuracy:
Current and Voltage 0.5%
Power ANSI C12.16, 1%
Measurement - True RMS True RMS up to 15th harmonic, 3-phase AC System
Outputs:
Pulse Output #1 (kWH ) N.O. Static Output (240VAC or 300VDC, 100mA max. @ 25˚C, derate 0.56mA per˚C above 25˚C) 2.41kV RMS isolation
Pulse Output #2 (H8463V/VB/ VBS) (Phase Loss or kVARh) N.C. Static Out put(240VAC or 300VDC, 100mA max. @ 25˚C, derate 0.56mA per˚C above 25˚C) 2.41kV RMS isolation
Mechanical:
Weigh t H84xxV: 0.8 lbs; H8 4xxVB: 6.35 lbs; H84xxVBS: 9.15 lbs
Protection Class V: IP40 front, IP30 back; VB: NEMA 1, IP40
Environmental:
Operating Temperature Range Meter: 0° to 60 °C (32° to 140°F); Display: -10° to 50°C (14° to 122°F)
Storage Temperature Range Meter and Display: -40°C to 85°C (-40° to 185°F)
Humidity Range 0-95% noncondensing
Agency Approvals UL508; ANSI C22.2, Cat. III, Pollution Degree 2, for distribution systems up to 347VAC (L-N)/600VAC (L-L);
CE per IEC61010, Cat. III, Pollution Degree 2, f or distribution systems up to 300VAC (L-N)/480VAC (L-L)
*For control voltages >415VAC to 600VAC order H84xxVBS
Year
5
Warranty
800.354.8556
+1 503.598.4564
www.veris.com
HQ0001713.B 01131
800.354.8556
+1 503.598.4564
www.veris.com
DIMENSIONAL DRAWINGS
+0.8
3.6"
–0.0
H84xxV
+0.8
3.6"
–0.0
(92 mm)
H84xxVB(S)
(92 mm)
2"
(50 mm)
(19 mm)
8.3"
(210 mm)
H8400 SERIES
0.8"
3.9"
(96 mm)
3.9"
(96 mm)
4.1"
(104 mm)
9.1"
(242 mm)
DATAOUTPUTS
H8436:
Full Data Set (FDS)
kWh, Consumption
kW, Real Power
kVAR, Reactive power
kVA, Apparent power
Power fac tor
Voltage, line to line
Voltage, line to neutral
Amps, Average cur rent
kW, Real power ØA
kW, Real power ØB
kW, Real power ØC
Power factor ØA
Power factor ØB
Power factor ØC
Voltage, ØA to ØB
Voltage, ØB to ØC
Voltage, ØA to ØC
Voltage, ØA to Neutral
Voltage, ØB to Neutral
Voltage, ØC to Neutr al
Amps, Current ØA
Amps, Current ØB
Amps, Current ØC
H8437: Extended Data Set (EDS)
(FDS Plus):
Amps, Current Neutral
Frequency
kVAh, Consumption
kVARh, Consumption
Minimum Real power
Maximum Real power
KVA, Apparent Power, Per Phase
KVAR, Reactive Power, Per Phase
KW, Total Real Power Present Demand
KVA, Total Apparent Power Present Demand
KVAR, Total Reactive Power Present Demand
KW, Total Real Power Max Demand
KVA, Total Apparent Power Ma x Demand
KVAR, Total Reactive Power Max Demand
THD, Voltage A-N, B-N, C-N
THD, Voltage A-B, B-C, A-C
THD, Current, Per Phase
Usage Hours
Usage Minutes
Tot al Hour s
Total Minutes
ORDERING INFORMATION
MODEL DESCRIPTION DATA OUTPUT DISPLAY SCREENS
PANEL MOUNT - 120-4 80V
(For Control Voltages > 415VAC to
600VAC order H84x xVBS)
H84 63V* Panel Moun t, 1V, CT Input , FDS
H8453V * Panel Moun t, 1V, CT Input , FDS
H8436V Panel Moun t, 1V, C T Input, FDS
H8437 V Panel Mount, 1V, CT Input, ED S
WALL MOUNT - 120-4 80V
(For Control Voltages > 415VAC
to 600VAC order H84x xVBS)
H84 63VB* Wall Mount , 1V, C T Input, FDS
H8453V B* Wall Mount, 1V, CT Inp ut, FDS
H8436VB Wall M ount, 1V, CT Input, FDS
H8437 VB Wall Mount , 1V, C T Input, EDS
WALL MOUNT - 240- 600V Pulse Modbus FDS EDS
H8463VBS* Wa ll Mount, 1V, CT Input, FDS, 240 -600V
H8453VBS* Wall Mo unt, 1V, CT Input, FDS, 240- 600V
H8436VBS Wall Mou nt, 1V, CT Inpu t, FDS, 240-600V
H8437 VBS Wall Mount, 1V, CT Inp ut, FDS, 240-60 0V
The H8453 has two normally open solid-state outputs: one kWh and one eld selectable for phase loss or kVARh. The
H8463 has one normally open output (kWh) and one normally closed output (eld selectable for phase loss or kVAR).
Pulse Modbus FDS EDS
n n
n n
n n
n n
Pulse Modbus FDS EDS
n n
n n
n n
n n
n n
n n
n n
n n
COMPANION CURRENT TRANSFORMERS
(Model/Amps)
H681
Small:
0-1 00 = 10 0A
0-2 00 = 200A
0-30 0 = 300A
Medium:
1-40 0 = 400A
1-60 0 = 600A
1-80 0 = 800A
Large:
2-80 0 = 800A
2-16 00 = 1600A
2-2000 = 2000A
2-24 00 = 2400A
(Output Type)
-
1V
= 0 -1VAC
Example:
H681 2-800 – 1V
ACCESSORIES
Fuse Kits (AH02, AH03, AH04)
DIN Rail Mounting Kit (AH23)
Modbus-to-BACnet Converter (E8950)
Modbus TCP Gateway (U013- 0012)
AH04
E8950
U013-0012
AH23
power/energy monitoring