Verint Nextiva S1808e, Nextiva S1816e, Nextiva S1816e-A, Nextiva S1808e-A, Nextiva S1816e-SP Quick Installation Manual

...
All users should read the user manuals for complete details on installation, usage and functionality.
Quick Installation Guide for the Multiport Encoders
1
Nextiva S1800e Series
This installation guide provides instructions for installing and performing the initial configuration. All users should read the user manuals for complete details on installation, usage and functionality.
Contents of the Package
One set of rack-mount brackets with four screws (Philips M3 x 6mm pan head)
One Nextiva S1800e series Quick Installation Guide
Optional Accessories
PS1261: Efficiency level V compliant power supply for Nextiva S1800e series
PS1281: 19-inch rack mountable power supply for up to 10 multiport devices.
PS1282: Efficiency level V compliant 19-inch rack mountable power supply available in two models:
PS1282-10: 19-inch rack mountable power supply for up to 10 - Nextiva S1800e series encoders.
PS1282-20: 19-inch rack mountable power supply for up to 20 - Nextiva S1800e series encoders.
PDP10-2: 19-inch 1U power distribution panel rack mount to connect up to ten Nextiva S1800e series
encoders
Hardware Overview
The Nextiva Multiport S1800e series multiport encoders are available in five models: S1808e, S1808e-A, S1816e, S1816e-A or S1816e-SP. Prior to adding the S1816e-SP encoder to Nextiva VMS, use SConfigurator to set the mode of the unit. The change will take effect after rebooting the unit. For information on changing the setting, see Setting the H.264 Encoding Mode for the S1816e-SP on page 6.
Nextiva S1800e Series Multiport Front View
Nextiva S1800e Series Multiport Rear View
The audio option is only available on the S1808e-A and S1816e-A.
2
Installing the Nextiva S1800e Series Encoder
This section explains how to install a Nextiva S1800e series encoder on a desktop or flat surface and mount the encoder in a rack.
NOTE: This equipment must be used in compliance with local laws and regulations.
To install the Nextiva S1800e series encoder on a flat surface:
1. Remove any debris and dust from the surface as well as the surrounding area.
2. Place the encoder on the flat surface.
3. Ensure that you have access to both the front and rear of the encoder and that the fan airflow is not blocked.
To install the Nextiva S1800e series encoder on a rack:
1. Align the rack-mount brackets with the holes on the side of the encoder.
2. Screw the rack-mount brackets to the encoder using 5 in-lb (0.56 N-m) force with the provided screws.
3. Slide the encoder into the 1U mounting space in the rack cabinet and ensure that the fan airflow is not blocked.
4. Secure the encoder to the rack cabinet using the screws supplied with the rack.