Verine NRDC**MN2, NRDC**SN2, NRDC**RN2, NRDC**MP2, NRDC**TN2 Installation, Maintenance & User Instructions

Important Note
This manual is only suitable for Verine Quasar MK2 models that are to be installed in GB / IE. If in the future the product is to be installed in any other country detailed as appropriate for the gas type and supply pressure on the rating plate then the manufacturer (BFM Europe Ltd.) must be contacted to obtain a set of instructions that are translated into the language of the country of destination, and reflect the differing legislative installation criteria for that country.
INSET RADIANT FUEL EFFECT GAS FIRE
Installation, Maintenance & User Instructions
Hand these instructions to the user
Model No’s NRDC**MN2, NRDC**SN2, NRDC**TN2 & NRDC**RN2 are for use on Natural Gas (G20) at a supply pressure of 20 mbar in G.B. / I.E. Model No’s NRDC**MP2 is for use on Propane Gas (G31) at a supply pressure of 37 mbar in G.B. / I.E.
** denotes variant of trim / fascia where applicable
CONTENTS
S
ection 1 Information and Requirements PAGE
1.0 Appliance Information 3-4 1
.1 Conditions of Installation 5
1
.2 Flue and chimney suitability 5
1.3 Fireplace / surround suitability 6
1.4 Shelf position 6 1
.5 Chimney inspection 6
1.6 Fire place opening / catchment space 7-8
1.7 Fitting to Metal Flue Boxes 9
1.8 Hearths 9
1.9 Spillage Monitoring System 9
Section 2 Installation of Fire
2.1 Unpacking the fire 10
2.2 Installing the fire box 10-19
2.3 Gas tightness and inlet pressure (MC models) 20
2.4 Gas tightness and inlet pressure (SC models) 20
2.5 Gas tightness and inlet pressure (RC models) 20
Section 3 Assembling Fuel Bed and Commissioning
3.1 Assembling the ceramics and fuel bed (coal models) 21-24
3.2 Assembling the ceramics and fuel-bed (pebble models) 24-27
3.3 Fixing the Infra-red Eye in position 28
3.4 Connecting the battery pack 29
3.5/3.6 Fitting the trim / fret (all models) 29
3.7 Lighting the appliance (Manual control models) 30
3.8 Lighting the appliance (Slide control models) 30-31
3.9 Lighting the appliance (Remote control models) 32
3.10 Lighting the appliance (Electronic fire control models) 33
3.11 Checking for clearance of combustion products 34
Section 4 Maintenance
4.1 Removal of the Burner Assembly (Manual control models) 35
4.2 Removal of the Piezo Igniter 35
4.3 Removal of the Control Tap 36
4.4 Removal of the Pilot Assembly 36
4.5 Removal of the Burner Assembly (Slide control models) 36-37
4.6 Removal of the Battery Ignitor 37
4.7 Repacing the Battery 38
4.8 Removing the Oxy-Pilot Assembly 38
4.9 Replacing the Control Cable 38-39
4.10 Removal of the Burner Assembly (Remote & EFC models) 40
4.11 Removal of the Valve (Remote & EFC models) 40
4.12 Removal of the EFC trim switch (EFC models only) 40-41
Section 5 User Instruction Section
5.1 Conditions of Installation & About Your New Fire 42-43
5.2 Operating the fire (MC Models) 45
5.3 Operating the fire (SC Models) 45
5.4 Operating the fire (RC Models) 46-47
5.5 Operating the fire (EFC Models) 47
5.6 Remote handset / EFC trim switch malfunction 48
5.7 Cleaning the Fire 49
5.8 Re-assembling the ceramics and fuel bed (coal models) 50-53
5.9 Re-assembling the ceramics and fuel bed (pebble models) 54-56
2
SECTION 1
INFORMATION AND REQUIREMENTS
1.0 APPLIANCE INFORMATION
Model NRDC**MN2 (MC) NRDC**MP2 (MC)
NRDC**SN2 (SC) NRDC**RN2 (RC) NRDC**TN2 (EFC)
Gas Type G20 G31
Main injectors (2 off) Size 260 Size 85
Pilot Type Copreci Copreci
21100 / 141 (MC) 21100 / 264 (MC) 21100 / 162 (SC & RC)
Max. Gross Heat Input : 6.9 kW 6.9kW Min. Gross Heat Input : 4.2 kW 4.2kW Cold Pressure : 20.0 +/- 1.0mbar 37.0 +/- 1.0mbar
Ignition : Push Button Piezo (MC models)
1.5V Battery Generator (SC models) 9V Battery (RC & EFC models)
Electrode Spark Gap 4.5mm nominal
Weight (without fender) Slide Control Models 13 kg
Manual Control Models 12 kg Remote / EFC Models 13.5 kg
Fire box Dimensions (with trim’s fitted)
Width : (with standard trim, no spacer) 470mm Height : (with standard trim, no spacer) 586mm Depth : (overall-without fender) 170mm
Gas Connection 8mm Compression (Supplied with fire)
Efficiency Declaration
The efficiency of this appliance has been measured as specified in BS 7977-1 : 2002 and the result is 48%. The gross calorific value of the fuel has been used for this efficiency calculation. The test data from which it has been calculated has been certified by BSI. The efficiency value may be used in the UK Government’s Standard Assessment Procedure (SAP) for energy rating of dwellings.
3
INSTALLATION REQUIREMENTS
1.1 CONDITIONS OF INSTALLATION
It is the law that all gas appliances are installed only by a GAS SAFE Registered Installer, in accordance with these installation instructions and the Gas Safety (Installation and Use) Regulations 1998 as amended. Failure to install appliances correctly could lead to prosecution. It is in your own interest and that of safety to comply with the law.
The installation must also be in accordance with all relevant parts of the Local and National Building Regulations where appropriate, the Building Regulations (Scotland Consolidation) issued by the Scottish Development Department, and all applicable requirements of the following British Standard Code of Practice.
1. BS 5871 Part 3 Installation of Decorative Fuel Effect Gas Fires
2. BS 6891 Installation of Gas Pipework
3. BS 5440 Parts 1 & 2 Installation of Flues and Ventilation
4. BS 1251 Open fire place components
5. BS 715 / BS EN 1856-2 Metal flue pipes for gas appliances
6. BS EN 1858 Clay Flue Blocks and Terminals
7. IS 813 : 1996 Domestic Gas Installation (Republic of Ireland)
No purpose made additional ventilation is normally required for this appliance, when installed in G.B. When Installing in I.E. please consult document I.S. 813 : 1996 Domestic Gas Installation, which is issued by the National Standards Authority of Ireland. If installing in Northern Ireland, please consult local building regulations. Any purpose made ventilation must be checked periodically to ensure that it is free from obstruction.
1.2 FLUE AND CHIMNEY SUITABILITY
This appliance is designed for use with conventional brick built or lined chimneys and fabricated flues and metal flue boxes conforming to BS 715 / BS EN 1856-2 All flues must conform to the following minimum dimensions.
Minimum diameter of circular flues 125 mm (Without Flue
Restrictor Fitted)
Minimum effective height of all flue types 3 metres
When fitting to conventional chimneys or 175mm flues it may be desirable to fit the flue restrictor baffle (supplied) to reduce the flue flow and increase the efficiency of the fire. Safe clearance of products must always be checked by carrying out a smoke match test as described.
4
1.3 FIREPLACE / SURROUND SUITABILITY
The fire must only be installed on a hearth it must not be installed directly onto carpet or other combustible floor materials.
The fire is suitable for fitting to non-combustible fire place surrounds and
proprietary fire place surrounds with a temperature rating of at least 150oc.
If a heating appliance is fitted directly against a wall without the use of a fire surround or fire place all combustible material must be removed from behind the trim. Soft wall coverings such as blown vinyl, wall paper etc. could be affected by the rising hot air and scorching and/or discoloration may result. Due consideration should be made to this when installing or decorating.
1.4 SHELF POSITION
The fire may be fitted below a combustible shelf providing there is a minimum distance of 200mm above the top of the fire and the shelf does not project more than 150mm. If the shelf overhangs more than 150mm the distance between the fire and the shelf must be increased by 15mm for every 25mm of additional over­hang over 150mm.
1.5 FLUE / CHIMNEY INSPECTION
Before commencing installation, a flue or chimney should be inspected to ensure that all the following conditions are satisfied.
1. Check that the chimney / flue only serves one fire place and is clear of any obstruction. Any dampers or register plates must be removed or locked in the open position.
2. Brick/stone built chimneys or any chimney or flue which has been used for an appliance burning fuel other than gas must be thoroughly swept. The base of the chimney / flue must also be thoroughly cleared of debris etc.
3. Any under-floor air supply to the fire place must be completely sealed off.
4. Ensure that the inside of the chimney / flue is in good condition along it’s length and check that there is no leakage of smoke through the structure of the chimney during and after the smoke pellet test. With pre-cast flues
it is especially important to check the inside of the flue for extruded cement / sealant protruding from the joints between the flue blocks. If present, these should be removed by rodding the flue before proceeding with the installation.
5. Using a smoke pellet, check that there is an up-draught in the chimney / flue and that the smoke can be seen issuing from the terminal / chimney pot outside.
5
There must be no leakage of smoke through the structure of the chimney during or after the smoke pellet test and it is important to check inside upstairs rooms adjacent to the chimney / flue. Check the chimney pot / terminal and general condition of the
brickwork or masonry. If the chimney or flue is in poor condition or if there is no up-draught do not proceed with the installation. If there is a history of down-draught conditions with the chimney / flue, a tested and certificated flue terminal or cowl suitable for the relevant flue type should be considered.
6. A spillage test must always be carried out during commissioning of
the appliance.
1.6 FIRE PLACE OPENING AND CHIMNEY CATCHMENT SPACE
The front opening of the fire place must be between 375 and 440 mm wide, and between 550 and 570mm high. If the opening exceeds these dimensions then a surround must be constructed from suitable non-combustible material to produce a correct size opening. Any surround must be suitably sealed to the fire place to prevent leakage. See below in fig.1
When installing into a brick built chimney, you must ensure that there is sufficient depth to accomodate any debris which may fall from the chimney. This depth must be sufficient to accomodate 12 litres of volumetric space.
Fire Opening
375mm Minimum 440mm Maximum
610mm Minimum
490mm Minimum
Fig. 1
550mm Minimum 570mm Maximum
Minimum Flat Sealing Area
6
Table A - Installation Depth Requirements for a Verine Quasar MK2 gas fire being installed into a brick built chimney, requiring 12.0 litres of debris collection volume (fig. 2)
When installing this product into a builders opening / brick-built chimney, the depth required is a minimum of 170mm (150mm for EFC models). The 12.0 litres of debris collection volume is achieved by the space available taper down the sides of the firebox. This appliance is suitable for use in fireplaces fitted with an existing chairbrick without the need for removal of the chairbrick, providing the minimum depth of the fireplace exceeds 260mm. If the depth is less than 260mm then the spacer (optional) must be used to give a minimum clearance from the rear of the fire to the rear of the chairbrick of at least 90mm to allow sufficient space for the collection of debris which may fall down the chimney. The fireplace must be checked to ensure that no part of the chairbrick is within 50mm of the flue outlet of the fire when installed.
For example, if the appliance was to be fitted into a 400mm wide opening (without a chairbrick), the depth required would be 170mm (150mm for EFC models). See fig. 2 below for explanatory diagram.
Fig. 2
7
Opening Width ( e.g. 400mm)
Depth Required
(e.g. 170mm or
150mm for
EFC models)
1.7 FITTING TO PRE-FABRICATED TWIN WALL METAL FLUE BOXES
The appliance may be fitted to twin wall metal flue boxes conforming to the constructional requirements of BS 715 / BS EN 1856-2, (for example the Selkirk LFE 175 box). The box must have a minimum flue diameter of 175mm internal and minimum internal dimensions of 170mm deep by 580mm high by 350mm wide. There are no maximum dimensional requirements for the box. The top face of the box must be insulated with a minimum thickness of 50mm of non­combustible mineral wool insulation or similar material. The flue box must stand on a non-combustible base of minimum thickness 12mm.
1.8 FITTING TO PRE-CAST FLUE INSTALLATIONS
When installing this appliance into pre-cast flues, always ensure that the spigot restrictor baffle has been removed. To install the fire box in to pre-cast flue starter blocks, there must be at least 170mm (150mm for EFC models) from the mounting face of the fire to the rear of the pre-cast flue starter block to allow sufficient space for debris
collection. It is important to consider this depth when choosing a fire surround as the thickness of the fire surround must be sufficient to give a total depth of at least 170mm (150mm EFC models) to the rear of the starter block, otherwise there will be insufficient depth. If in doubt about the suitability of the fire contact BFM Europe Ltd for advice before proceeding. This fire has been designed to fit
standard 100mm pre-cast starter blocks with 3 inch rebated surrounds.
It is important to ensure that the pre-cast flue is in good condition and is free from extruded mortar or sealant from between the flue blocks.
This appliance has been tested for use in a pre-cast flue block complying with BS EN 1858. In accordance with BS EN 1858, pre-cast flues built with directly plastered faces (front or rear) are not correctly installed as to ensure proper operation with any type of gas fire. In some instances of this flue construction, temperature cracking of surface plaster may occur through no fault of the appliance. An air gap or some form of insulation material should be installed to prevent normal flue temperatures from damaging wall surfaces.
1.9 HEARTHS
This appliance must only be installed on to a concrete or non-combustible hearth. The hearth material must be a minimum thickness of 13mm with the top surface at least 50mm above the floor. The hearth must be fitted symmetrically about the fire opening and have a minimum width of 760mm and a minimum projection of 300mm forwards from the fire opening (320mm for EFC models). If the appliance is fitted with a black 50mm spacer frame (not suitable for EFC models), then the hearth projection must be increased to 350mm forwards of the fireplace opening.
8
1.10 SPILLAGE MONITORING SYSTEM
This appliance is fitted with an atmosphere sensing spillage monitoring system in the form of an oxygen sensing pilot. This is designed to shut the fire off in the event of a partial or complete blockage of the flue causing a build up of combus­tion products in the room in which the fire is operated. The following are important warnings relating to this spillage monitoring system :-
1) The spillage monitoring system must not be adjusted by the installer.
2) The spillage monitoring system must not be put out of operation.
3) When the spillage monitoring system is exchanged only a complete original
manufacturers part may be fitted. It is not possible to replace individual parts on the pilot system on this appliance, only a complete pilot assembly (including the thermocouple) may be fitted.
9
SECTION 2
INSTALLATION OF FIRE
2.1 UNPACKING THE FIRE
Carefully lift the fire out of the carton. Remove the loose item packaging carefully from the front of the appliance. Check the contents as listed :-
Packing Check List - All models
1 off Fire box / burner assembly 1 off Boxed ceramic base, front ceramic rail and 18 coals. 1 off Loose items bag 1 off Installation / user book
RC models only
1 off Remote control handset 6 off AA Batteries 1 off PP3 Battery
EFC models only
6 off AA Batteries
2.2 INSTALLING THE FIRE BOX
Establish which type of flue you are intending to install the fire in to :-
225 x 225mm (9 inch x 9 inch) brick built chimneys 175mm (7 inch) diameter lined brick or stone flue, insulated pre-fabricated metal flue box to BS 715 / BS EN 1856-2 or Pre-Cast Flue to B.S. E.N. 1858
When installing into 125mm (5 inch) diameter lined brick or stone flue, or insulated pre-fabricated metal flue box to BS 715 / BS EN 1856-2 and pre­cast flues the restrictor baffle must not be fitted.
A spillage test must always be carried out to check satisfactory clearance of flue products, regardless of the type of flue the appliance is being fitted to.
10
For manual control models proceed as follows :-
a) Remove the trim / fret. Remove the burner heat shield from the front of
the fire box to allow access to the burner. See fig. 3 below.
Fig. 3
b) Ensure that the hearth is protected from damage and carefully lift the
fire box into the fire opening, then slide it back into position. Check that the fire box flange fits flush to the sealing face of the fire surround or wall with no gaps present.
c) Remove the four retaining screws securing the burner to the firebox.
The base of the burner unit can now be pulled forward, allowing the burner to be removed from the fire box. See fig. 4 below.
Fig. 4
11
For slide control models proceed as follows:
d) Remove the trim / fret. Remove the burner heat shield from the front of
the fire box to allow access to the burner. See fig. 5 below.
Fig. 5
e) Ensure that the hearth is protected from damage and carefully lift the
fire box into the fire opening, then slide it back into position. Check that the fire box flange fits flush to the sealing face of the fire surround or wall with no gaps present.
f) Remove the burner. To allow burner removal, the control lever operat
ing cable must be removed. The control lever operating cable can be seen running across the base of the fire, below the burner. To release the cable, unscrew the cable securing screw located in the centre of the aluminium operating arm and pull the cable out from its fixing hole. Release the other end of the cable by pushing the cable forwards to the right, i.e. into the operating arm so as to release the tension. Pull the cable nipple out of the retaining hole and remove the cable through the slot in the operating arm. See fig. 6 overpage
12
Fig. 6
g) Unscrew the burner assembly fixing screws at either side of the firebox,
and the two fixing screws at the base of the fire (See fig. 7 below). Carefully pull the base of the burner forwards from the fuel-bed support panel. The burner can now be removed from the appliance.
Fig. 7
13
For remote control / electronic fire control models proceed as follows:
a) Remove the trim. Remove the burner heat shield from the
front of the fire box to allow access to the burner. See fig. 8 below.
Fig. 8
b) Ensure that the hearth is protected from damage and carefully lift the
fire box into the fire opening, then slide it back into position. Check that the fire box flange fits flush to the sealing face of the fire surround or wall with no gaps present.
c) Remove the four retaining screws securing the burner to the firebox.
The base of the burner unit can now be pulled forward, on EFC models disconnect the trim switch lead from the control board to allow the burner to be removed from the fire box. See fig. 9 below.
Fig. 9
14
Continue for all models
Whilst the fire box is still in position, decide which side the gas supply is to enter the fire from. If concealed pipe work is required plan the pipe run to enter the fire box through one of the openings in the sides of the fire box below the fuelbed support panel and connect to the isolating / inlet elbow. The gas connection to the appliance should be made to the isolating / inlet elbow using 8mm rigid tubing. There must be no soldered joints within the firebox. See fig. 10 & 11 below for suggested concealed pipe layouts.
Fig. 10
Fig. 11
Note : Before breaking into the gas supply a pressure drop test should be carried out to establish that the existing pipework is sound.
Carefully withdraw the fire box from the opening to enable the gas supply and fire fixing to be completed.
15
Firebox
Fireplace
Builders Opening
Gas Supply
Firebox
Approx. 40mm
Fireplace
Gas Supply
Approx. 40mm
IMPORTANT : Sealing of the Gas Unused Gas Pipe Inlet Apertures
In line with current GAS SAFE regulations, it is imperative that the gas supply inlet apertures that are not utilised during the installation are sealed with the foil tape as supplied. Failure to seal these inlet apertures could lead to flame
reversal, which in turn will damage the burner and control systems of the product. Fig. 12 below shows a correctly sealed installation.
Fig. 12
PLEASE NOTE :-
Seal off unused gas inlet
apertures and cable fixing holes
as shown
Only holes to be left are the specifically sized air relief holes as indicated by the labels positioned by them and the gas inlet aperture that is used
BFM EUROPE LTD WILL NOT BE LIABLE FOR GUARANTEE CLAIMS THAT ARE AS A DIRECT RESULT OF THE UNUSED GAS INLET APERTURES NOT BEING CORRECTLY SEALED.
16
The preferred method of fixing which is suitable for almost all situations is the cable fixing method which is described in the following section in detail.
The fire may be secured using the cable method as described below, or alterna­tively, in installations where the cable method is not suitable (eg. loose masonary in rear of fire opening)
To fit using the preferred cable method proceed as follows-
h) Mark out and drill 4 off No 14 (6mm) holes in the back face of the fire
opening in the positions shown below in fig. 13
Fig. 13
Fit the wallplugs provided and screw the fixing eyes securely into the rear of the fire opening. If the clearance at the rear of the fire is at the minimum specified for a precast flue application, it may be necessary to bend over the lower fixing eyes after screwing them fully in to the rear of a pre-cast starter block.
i) Uncoil the two fire fixing cables and thread one end of each of the
cables through one of the two holes on each side of the flue outlet shroud.
j) Position the fire carefully on the (protected) surface of the hearth and
reach into the fire opening. Thread each of the cables vertically downwards through the pair of fixing eyes on the same side of the fire. Thread the free end of the cables through the corresponding circular hole on each side of the lower rear of the fire. Carefully slide the fire box back into the fire opening and pull both cables tight.
17
20mm
500mm
Fireplace Opening
100mm
250mm
k) Thread a tensioning screw over each of the cables and ensure that the
tensioning nut is screwed fully up against the hexagon shoulder of the tensioning screw (this provides maximum travel for the tensioning nut).
l) Fit a screwed nipple on to each of the cables and pull hand tight up
against the tensioning screw, then secure each nipple with a flat bladed screwdriver. See fig. 14 below
Fig. 14
m) Evenly tighten the tensioning nuts to tension both cables and pull the
fire snugly against the wall. Do not overtighten, it is only necessary to pull the seal up against the sealing face of the wall, it does not need to be compressed. Check that there are no gaps behind the seal.
n) With the fire securely in place, if a concealed gas connection has been
made through either of the access holes in the sides of the fire, the holes should be closed around the pipe to prevent leakage of air through the gap around the pipe.
o) Refit the burner. Fit the four retaining screws and check that the burner
is correctly locked into position. On slide control models refit the control cable. To do this, firstly locate the nipple on one end of the cable into recess in operating arm and then secure the front part of the operating arm back onto the rear of the operating arm with the retained screw.
18