Verilink 1558D Installation Guide

TRANSPORT
®
1558D APS
Configuration Guide
1558D Front View
Part Number 45-00102
Revision 1.0
SUPV
1
PWR
STATUS
ALOCKED B
3
2
4
PATH
SELECT
AUTO
A
5 6
PATH
STATUS
ALM LOS LP
B
A B
7 8
RX BRDG
N E T
A
TX BRDG
RX BRDG
N E T
B
TX BRDG
9
10
DTE
STATUS
SD RD TEST
13
12
11
RL
LOOP
NORM
14
TxPORT
LL
1558D Controls and Indicators
Index Indicator Description
1 SUPV The Supervisory port allows the user to connect to the 1558D via a PC running the suppl ied L APS softw are. 2 Power The power (green) L ED will be ON whe n a nominal power source of 110 volts AC is present. 3 Locked When the Lock ed amber LED is on, the 1558 D has been manu ally or remo tely (soft c ontrol) force d and locked to
4 A / B These green status LEDs indicate which of the two T1 receive paths (A or B) is presently actively carrying the service 5 Path Select
Auto/A/B
6 Alarm
A/B
7 LOS When on, thes e red LEDs indicate that no T1 pulses are being detected on the receive signal paths from the ne tw ork
8 Loop
A/B
9/10 Test Jacks Bantam test access jacks and bridge/monitor jacks are provided to gain physical test access to the T1 path for NET A,
11 Send Data This green LED will indicate that data transitions are present on the Send Data (to the network) lead coming from the
12 Receive
Data
13 Test This LED (tri-colored amber, red, green) will indicate when the DSU portion of the 1558D has been placed in a test
14 Loop
Switch
either the A or B path. Moving the Path Select switch back to the AUTO position or remotely sending an unlock com­mand will turn off this LED and restores normal APS operation.
The user can manually force and lock either the A or B path as the active path by moving this switch from the AUTO position to either the A or B position. The 1558D is now manually locked to this path and will not switch from it, even if the selected path fails
When on, these red LEDs indicate that one or more of the user definable alarm parameters (ES, CSES, LOS, and LOF) have been met or exceeded for Pa th A or Path B, respectively.
for Path A or Path B, respectively. When on, these amber LED indicates that a loop (either manually or under soft control) has been activated for Path A
or Path B, respectively .
NET B, and the T1 DTE transmit an d receive signal paths (see 1558D Bloc k Diag r am).
DTE equipment. The LED will be on for a mark condition and off for a space condition. The LED will vary in intensity depending upon the relative number of marks or spaces present at any gi ven time.
This green LED will indicate that data transitions are present on the Receive Data lead coming from the active network path (A or B). The LED will be on for a mark condition and off for a space condition. The LED will vary in intensity depending upon the relative number of marks or spaces present at any gi ven time.
mode either via re mote co mmand s or activ ation of t he front p anel lo op switch. The LED wi ll be ON (a mber) whe n the manual swi tch i s pl aced in the l oc al lo op p osit ion or w hen a rem o te eq uip men t or V.5 4 loop co mm and h as b ee n received. Initially, the LED will be on (amber) when the manual loop switch is placed in the Remote Loop (V.54) position. After activation, the LED will turn from yellow to red if the unit does not detect a far end V.54 loop. If a loop is detected from the far end, the LED will change from amber to green (far unit in loop).
This three position loop switch (Remote Loop, Normal, Local Loop) al lows the user to initiate a LL (local loop) or a far end 1558D RL (remote V.5 4 loop). Moving the switc h to the LL (lo cal lo op) posit ion ini tia tes a loo p of both th e A and B paths back to the 1558D unit (see 1558D Block Diagram). Placing the switch in the RL position initiates a V.54 inband loop comma nd towards the far end unit. A V.54 loop initiates an an Equipment Loop of the far end unit (see 1558D Block Diagram. Mov in g the switch back to the Normal position removes the loop co ndi ti on (either local or remote). The Remo te loop/unloop process takes approximately 5 seconds to complete.
1558D
NET BNET A
COM BUS
ON
S1 S2 S3
V.35
ON
S4
ALARM
GND
N.O.
COM
N.C.
IN OUT
1558D Wiring and Connector Information
COM BUS IN
PIN
RJ11 6-pin
Modual
Connector
1 Not Used Not Used 2 Signal Ground Signal Ground 3 Data, output Data, Output 4 Data, input Not Used 5 Signal Ground Signal Ground 6 Not Used Not Used
COM BUS Out
RJ11 6-pin
Modual
Connector
OFF
1558D Rear View
Function CCITT Name
Frame Ground 101 FG A
Signal Ground 102 SG B
Send Data 103 A/B SD P, S
Receive Data 104 A/B RD R, T
Request to Send 105 B RTS C
Clear to Send 106 B CTS D
Data Set Ready 107 B DSR E
Data Terminal Ready
108 B DTR H
Direction
DTE....1558
OFF
1558D V.35
(34 pin, female)
Data Carrier Detect 109 B DCD F
Pin
NET A & B, RJ48
Modular Connectors
Transmit Clock 114 A/B TC Y, AA
Receive Clock 115 A/B RC V, X
1 Data In, T ip 2 Data In, Ring 3 Not Used
External Clock 113 A/B EXT.TC U, W
Test Mode 142 TM K
4 Data Out, Tip 5 Data Out, Ring 6 Not Used 7 Not Used 8 Not Used
Terminal 1558D Alarm Relay Terminal Descriptions
GND
(Ground)
N.0.
(normally open)
COM
This terminal can be used to connect the 155D to a good earth ground
External alarm equipment requiring a normally open contact should be wired to this terminal and the common terminal
Common lead for the 1558D alarm relay contact(s)
(Common)
N.C.
(normally closed)
External alarm equipment requiring a normally closed contact should be wired to this terminal and the common terminal
1558D Option Switch Configuration Information
Option Switch S1, Pos. 1 - 8
Position Description
OFF
1
2,3
4
5
6
7
8
= Card Function, Slave
ON= Card Function, Master
,OFF
OFF
= Boot from Switches OFF,ON = Boot from Manager ON,OFF = Boot from RAM ON,ON = Boot from ROM
OFF
= ARM from ROM
ON= ARM from RAM
OFF
= Enable Frame Error Alarm
ON = Disable Frame Error Alarm
OFF
= LOS, Enabled
ON= LOS, Disabled
OFF
= NET/ A, B8ZS
ON = NET/A, AMI
OFF
= NET/B, B8ZS
ON = NET/B, AMI
Option Switch S2, Pos. 1 - 8
Position Switch S2 Description
OFF
1
2
3,4 NET A LBO Value
5,6 NET A LBO Value
7,8
= CSU Mode, Enabled
ON = CSU Mode, Disabled
OFF
= Path Revert, Disabled
ON = Path Revert, Enabled
OFF, OFF
0.0 db
7.5 db OFF, ON
15.0 db ON, OFF
22.5 db ON, ON
OFF, OFF
0.0 db
7.5 db OFF, ON
15.0 db ON, OFF
22.5 db ON, ON
OFF, OFF
=Network Clocking OFF, ON = Network Clocking ON, ON = Internal Clocking ON, OFF = External DTE Clocking
Option Switch S4, Positions 1 - 6 (speed selection)
Pos1Pos2Pos3Pos4Pos5 Pos 6
(64Kb)
OFF OFF OFF OFF 1536
OFF
OFF OFF OFF ON OFF 1472 1288 23
ON OFF OFF ON OFF 1408 1232 22
OFF ON OFF ON OFF 1344 1176 21
ON ON OFF ON OFF 1280 1120 20
OFF OFF ON ON OFF 1216 1064 19
ON OFF ON ON OFF 1152 1008 18
OFF ON ON ON OFF 1088 952 17
ON ON ON ON OFF 1024 896 16
OFF OFF OFF OFF ON 960 840 15
ON OFF OFF OFF ON 896 784 14
OFF ON OFF OFF ON 832 728 13
ON ON OFF OFF ON 768 672 12
OFF OFF ON OFF ON 704 616 11
ON OFF ON OFF ON 640 560 10
OFF ON ON OFF ON 576 504 9
ON ON ON OFF ON 512 448 8
OFF OFF OFF ON ON 448 392 7
ON OFF OFF ON ON 384 336 6
OFF ON OFF ON ON 320 280 5
ON ON OFF ON ON 256 224 4
OFF OFF ON ON ON 192 168 3
ON OFF ON ON ON 128 112 2 ON ON ON ON ON 64 56 1
OFF
Pos 6 ON
(56Kb)
1344
Option Switch S4, Pos. 7 - 10
Position Switch S4 Description
OFF
7
8
9
10 Spare, Not Used
= Contiguous DS0s
ON = Alternate DS0s
OFF
= Control Lines (CTS, DSR,CD) are set on ON = Control Lines follow (DSR follows T1 sync, CTS follows RTS, and CD fol­lows T1 density status)
OFF
= Data Invert Disabled ON = Data Invert Enabled
DS0
24
Option Switch S3, Pos. 1 - 8
*APS Mgr.
Unit Pos.
1.01 1/2
1.02 3/4 ON ON OFF OFF OFF
1.03 5/6 ON OFF ON OFF OFF
1.04 7/8 ON ON ON OFF OFF
1.05 9/10 ON OFF OFF ON OFF
1.06 11/12 ON ON OFF ON OFF
NET A/B
Address
Pos
Pos
1
OFF OFF OFF OFF
OFF
Pos
2
3
Pos
4
Pos
5 - 8
1558D Block Diagram
Tx Clk
Ext Clk
Rx Clk
TM DSR
CD RTS
RD
SD
COM Bus
IN
COM Bus
OUT
Alarm
Contacts
(COM,
NO, NC)
Select
Path A/B
V.35 Interface
Eq/V.54
Loop
Loop
Set/Reset
CPU
ROM
RAM
SUPV
Performance History, Alarms, Unit Address
APS
Port
A
B
Deframer
Fac/Local
PLB
Framer
Loop
Line
Loop
+5 VDC
±12 VDC
Power
Supply
Bridge
Jack
Bridge
Jack
Receive
Transmit
NET A
AC Input, 110 VAC
Jack
Jack
NET A
Line
Protection
Line
Protection
Rx
NET
A
RJ48
Tx
NET A
Signal
Split
BERT: QRSS, 1:8, 3:24, etc.
NET B
Deframer
Fac/Local
PLB
Framer
Loop
Line
Loop
Bridge
Jack
Bridge
Jack
NET B
Receive
Transmit
NET B
Jack
Jack
Line
Protection
Line
Protection
Rx
NET
B
RJ48
Tx
TxPORT Customer Service
TxPOR T
127 Jetplex Circle
Madison, Alabama 35758
888-4TxPORT / 800-926-0085 / 205-772-3770
Customer Service Returns: 800-926-0085, ext. 2227
Product Technical Support
Normal Hours - 8 a.m. to 5 p.m. C e ntral, Monday – Friday
Telephone: 888-4TxPORT / 800-285-2755 / 205-772-3770
Emergency - Nights / Weekends / Holidays:
Telephone: 800-285-2755
E-Mail: support@txport.com
Loading...