Verilink 1250 Installation Guide

TRANSPORT
®
1250 P ower and Alarm Card
Configuration Guide
1250 Front View
Part Number 45-00007
Revision 2.0
ALARM &
POWER
123
1234
O N
CHASSIS
ADDRESS
1 2 3 4 5 6 7 7
POWER
NORMAL
SILENT
ACO
1250 Controls and Indicators
Index Indicator Description
Silent disables the ACO.
4 ACO The Alarm Cut Off LED indicates that the alarm
relay contacts are disabled.
5 ALARM This LED indicates that an APS shelf alarm has
occurred. 6 FUSE ALARM This LED indicates that a bus fuse has blown. 7 3 AMP GMT Two 3 Amp fuse for power source A/B.
ALARM
®
A
FUSE
ALARM
3 AMP
B
TRANSPORT
GMT
1250
NOTES: 1250 cards that are Rev. 2.63 or higher add the capability to maintain alarm card functions (front panel indicators, switch functions, and relay operation) even when Fuse A and B are open. This is possible be­cause these cards have the alarm circuitry wired to the ‘hot’ side of the incoming A and B external power source(s). In early revi­sions, the 1250 alarm functi ons were only op­erational if one or more of the front panel fuses were functional (not blown).
Earlier versions of the 1250 card were called 1555P cards. The function of each card is the same.
Chassis Address Selection
Each APS chassis must be assigned a block of addresses for its 1557 APS cards so that the 1559 APS Manager may communicate with them. The DIP switch located on the front panel of the 1250 Alarm and Power C ard is used to provide up to 8 chassis addresses. These addresses are used by the APSM to poll and send commands to the 1557 cards.
Three out of the four switches (S2, S3, and S4) are set to one of the 8 pos­sible address codes as shown in the table to the right. The DIP switch posi­tions are number S1 thr ough S4, with S1 on top an d S4 on bottom. Not e that S1 is not used.
The first unit address (1557 card) in the chassis is the base address plus 1. For example, if S2, S3, and S4 were all set to 0, the first unit address in the chassis would be ‘1’ (0 + 1).
Chassis Addresses
Chassis Number
10 to 27000 2 32 to 59 0 0 1 3 64 to 91 0 1 0 4 96 to 123 0 1 1 5128 to 155100 6160 to 187101 7192 to 219110 8224 to 251111
Base
Address
S2 S3 S4
TRANSPORT
®
1050 Chassis Rear View
Power and Alarm Position
J1
J2
C14 C13 C12 C11 C10 C9 C8 C7 C6 C5 C4 C3 C2 C1
J3
J4
REMOTE ALARMS/ CONTROL
J5
TB1
J6
J7
J8
J9
Front Panel
(see other side)
21
36
C15
Pin C15 Function
1 -48 VDC - Primary 5 48 VRTN
9 -48 VDC - Secondary 18 Alarm NC 19 Alarm NO
35
20 Alarm Common 29 NMS In 30 NMS Out 34 NMS Ground
3 Amp
GMT Fuses
Contacts
:
Primary
Name: Phone:
Location: Date installed: Date last serviced: Slot number:
Chassis number:
Fuse number: Source A:
Source B:
FUSE
F1
Secondary
1250 Power and Alarm Card
TxPORT Customer Service
127 Jetplex Circle
Madison, Alabama 35758
Customer Service
800-926-0085, ext. 227
Product Technical Supp or t
(8 a.m. to 5 p.m. Central Time)
800-285-2755 or
205-772-3770
Emergency After Hours
800-285-2755
E-Mail (Internet Address):
support@txport.com