TRANSPORT
®
1061 T1 Multicast
Configuration Guide
45- 00117
1.00
Front Panel Description
STATUS: Green LED illuminates when the unit is powered. Red LED illuminates when an alarm
exceeding thresholds is detected or other unit failure.
ACO: Amber LED illuminates when the Alarm Cutoff switch is On (switch left) indicating that the
alarm relay contacts are forced to the No Alarms condition.
ACO SW: Alarm Cutoff switch controls the alarm relay circuitry. When the switch is On (left), the
circuitry is deactivated. The ACO indicator still functions normally.
ADDRESS: This 8-position switch (Switch 1) sets the address of the unit ta rg eted by the comm and from
the EM8000 cont r oll er. Val i d a dd re s se s a r e 0 thr o ug h 253 with zero being the br o ad c as t a dd r e s s a n d 25 3
reserved as a universal hailing frequency.
FORCE: Amber LED illuminates when the select switch is in either the A or B position. NMS
commands will not override this switch.
A / B: Green LEDs illuminate indicating which input (A or B) is being broadcast to the ports. If both
ports (A and B) have input, only the selected port’s indicator illuminates.
Select: The select switch forces the input to either the A (switch left) or B (switch right) inp ut. N (switch
center) is for normal operation.
NMS BR: S2-1 and S2-2 set the NMS bit rate. Refer to the NMS Bit Rate table below for setting
information.
SUPV BR: S2-3 and S2-4 set the Supervisory port bit rate. Refer to the SUPV Bit Rate table below for
setting information.
LSB: S2-5 sets the Least Significant Bit with respect to the duplex select. Refer to the Duplex Select
table for setting information.
Duplex Select : S2-6 and S2-7 select the channel (1-12) that is full duplexed to the selected (A or B) input
channel. No channel is selected when set to zero. The expansion settings (A EXPD, B EXPD, and A/B
EXPD) full duplex back to their respecti ve T1 in put lines. For e xample, th e A EXPD setting full duplex es
the return feed back to the T1 A input line; the B EXPD setting full duplexes the return feed back to the
T1 B input line; and the A/B EXPD setting full duplexes the return feed back to the respective T1 A and
T1 B input lines.
MSB: S2-8 sets the Most Significant Bit with respect to the duplex select. Refer to the Duplex Select
table for setting information.
Activity Indicators: The two red activity indicators allow you to identify transmission flow in the unit.
The left light indicates supervisory port transmission. The right light indicates NMS bus transmission.
SUPV: The supervisory por t allow you to configure the unit’s software through a VT100 connection.
TRANSPORT
1061
Multicast
ACO SW
B
B
®
ADDRESS
A
FORCE
A
NMS BR
SUPV BR
LSB
DUPLEX SEL
MSB
A
STATUS
ACO
B
N
S
U
P
V
Duplex Select
S2-5 S2-6 S2-7 S2-8
0BBBB
1ABBB
2BABB
3AABB
4BBAB
5ABAB
6 BAAB
7 AAAB
8BBBA
9ABBA
10 B A B A
11 A A B A
12 B B A A
A Expd A B A A
B Expd B A A A
A/B Expd A A A A
NMS Bit Rat e
NMS BR S2-1 S2-2
19.2 kbps B B
9.6 kbps A A
2.4 kbps B A
1.2 kbps A B
SUPV Bit Rate
Bit Rate S2-3 S2-4
19.2 kbps B B
9.6 kbps A A
2.4 kbps B A
1.2 kbps A B
Specifications
Input/Output
Input (A/B): Impedance terminated
100 Ω (± 2%)
Unterminated 1000 Ω
Ext. Alarm Inputs: Off when ≤ 3 mA,
On when > 4 mA and
≤ 20 mA
Output: Per 62411 waveform
into 100 Ω
Power
DC Power: -48 VDC (±10%), 100
mA max.
2.5 Watts, 8.5 BTU
max.
Connection: Terminal block
Mechanical
Mounting: Desktop, wall, horizon-
Dimensions
Width: 1.72 in (4.37 cm)
Height: 6.8 in (17.27 cm)
Depth: 10.5 in (5 0. 90 cm)
Weight: 4.0 lbs (1.81 kg)
Industry
FCC Compliance: Part 15 Class A,
U.S. Safety: UL 1950 Third Edition
Canadian Safety: CSA C22.2
tal rack, vertical rac k
or vertical nest mount
Standards
Subpart B
No. 950-95

Rear Panel Description
NMS (IN/OUT): These two ports connect th e chassis to the Tx PORT EM8000. W ith in the cha ssis, each unit
is physically connected to the next unit in a daisy chain. Each unit in the NMS chain must have a unique
address, however, they all use the same NMS bit rate.
Expand (A/B): These two 8-pin modular jacks expand the A or B inputs to other 1061 units providing
additional outputs. The maximum number of units is ten.
T1 IN (A/B): These two 8-pin modular jacks are used for the T1 input signal as wel l as the output of each
input. They output AIS with no input.
T erminate/Unterminate: These two slide switches set the A or B input. Terminate is used when the
expansion connector is not used. Unterminate is used when the expansion connector is daisy chained. The
recessed switches can be moved with a screwdriver. The last unit in a daisy chain must be terminated.
T1 Broadcast Port: This 50-pin female connector is used for the expanded outputs of either the A or B
inputs. Refer to the T1 Multicast Port Pinout table.
Alarm/P ower: This 10-pin connector is used as a power and alarm conne ction. The unit requires a -48
VDC power source capable of supplying 100 mA current. The chassis ground lead is connected to pin 8. The
-48 VDC lead is connected to pin 7. The return lead is connected to pin 5. The alarm connection is made on
pins 6 and 9 to operate in a normally closed mode (NC - opens on alarm) or on pins 6 and 10 to operate in a
normally open mode (NO - closes on alarm). The contacts are rated at 1.0 Amp AC or 1.0 Amp DC. 18 to 20
gauge wire is recommended. The external alarm connectors are unpowered, isolated inputs indi cating
external alarms on inputs A and B. External alarm A is connected on pin 1 (+) and pin 2 (-). External alarm B
is connected on pin 3 (+) and pin 4 (-). They are 10 mA current loops and must be powered externally.
Rear Panel
N
M
S
O
U
T
A
E
X
P
D
T1
A
I
N
UNTERM
A
TERM
ALARM/
POWER
1
18
81
1818
81 81
B
26 50
N
M
S
I
N
B
E
X
P
D
T1
B
I
N
Connector Pinout
Pin NMS Out NMS In EXPAND T1 IN Alarm/Power
1 Not Used Not Used Data Out Data In External Alarm A (+)
2 Signal Gnd Signal Gnd Data Out Data In External Alarm A (-)
3 Data Out Data Out Not Used Not Used External Alarm B (+)
4 Not Used Data In Data In Data Out External Alarm B (-)
5 Signal Gnd Signal Gnd Data In Data Out 48 VDC Return
6 Not Used Not Used Not Used Not Used Alarm Common
7 Chassis Gnd Chassis Gnd -48 VDC
8 Chassis Gnd Chassis Gnd Frame Ground
9 Normally Closed
10 Normally Open
T1 Multicast Port Pinout
Tip Ring Function
1 26 Output # 1
2 27 Input # 1
3 28 Output # 2
4 29 Input # 2
5 30 Output # 3
6 31 Input # 3
7 32 Output # 4
8 33 Input # 4
9 34 Output # 5
10 35 Input # 5
11 36 Output # 6
12 37 Input # 6
13 38 Output # 7
Tip Ring Function
14 39 Input # 7
15 40 Output # 8
16 41 Input # 8
17 42 Output # 9
18 43 Input # 9
19 44 Output # 10
20 45 Input # 1 0
21 46 Output # 11
22 47 Input # 1 1
23 48 Output # 12
24 49 Input # 1 2
25 50 Frame Gnd
10
- - -
____
48 VDC
TRANSPORT
127 Jetplex Circle
Madison, Alabama 35758
Sales and Marteking
205-772-3770
800-926-0085
info@txport.com
Returns/RMA
800-926-0085, ext. 2227
Technical Support
(205) 772-3770
800-285-2755
support@txport.com
251
®