TRANSPORT
®
1060A Broadcast Card
Configuration Guide
45-00118
1.00
321
4 5 6
B
N
®
TRANSPORT
STATUS
1060A
Broadcast
ACO
A
FORCED
ACO SW
Front Panel Description
1 Status: Green LED illuminates when the unit is powered and operation is normal. The red LED illuminates when an alarm exceeding
thresholds is detected or for other unit failure.
2 ACO: Amber LED illuminates when the ACO (alarm cutoff) switch is placed in the left (On) position. It indicates that the alarm relay
contacts are forced to the
3 ACO SW: The alarm cutoff switch controls the alarm relay circuitry. When the switch is placed in the left (On) position, this circuitry is
deactivated. The ACO indicator still functions as usual.
4 Forced: Amber LED illuminates indicating that the 5 A / B: Either the A or B green LED illuminates indicating which input is being broadcast to the ports. Even if both Port A and Port B have
input, Port A will be selected and the A indicator illuminates.
6 Force Switch: This switch is used to force the input to either the A or B input.
No Alarms
condition.
Force
switch is in either the A or B direction.
TRANSPORT
®
General
The TxPORT 1060A Broadcast card (part num ber F­1060-100A-111) is used to expand a single T1 input to 14 T1 inputs w here bridging m ay not be po ssible or practical.
The inputs are redundant , switching from the Port A to Port B or Port B to Port A on receipt of an alarm in­dication signal (AIS) or on a loss of signal (LOS). AIS occurs on the r eceipt o f 8192 consec utive ones. LO S occurs on the receipt of 175 consecutive zeros.
Installation
The 1060A card is designed to be installed in a single unit housing module for standalone desktop use or for wall mounting.
Operation
The card has t wo input choices - A or B. The gr een LEDs indicate w hich si de is sup ply in g the in put . The
unit alarms on a loss o f signal (LOS) or on an al arm indication signal (AIS).
The manual force switch is used to select the input to either side A or the side B. The ber) indicates that the force switch is out of th e mal) position. The unit will stay in the selected input mode unless an alarm condition is detected on the se­lected input. The unit will not switch from the selected input if an alarm condition exists on the other input.
The unit has a Bridge or Term option on both inputs al- lowing more than one input to be tied together with the last one terminated.
FORCED
LED (am-
N
(nor-
Specifications
Input (A/B): Impedance terminated 100 (± 2%)
Unterminated 1000
Output: Per 62411 waveform into 100
Power
DC Power: - 48 VDC (± 10%), 50 mA max
2.5 Watts, 8.5 BTU maximum
Connection: Terminal block
Mechanical
Mounting: Desktop
Wall Horizontal or vertical rack Vertical nest mount
Dimensions: 1.72 in (4.37 cm) Wide
6.8 in (17.27 cm) High
10.5 in (26.67 cm) Deep
Weight: 4.0 lbs (1.81 kg)
Industry
FCC Compliance: Part 15 Subpart B, Cla s s A FCC Part 68 Reg:
Standards
1
1060A Broadcast Card Rear Panel
81
81
EXPAND
AB
Expand:
1818
1 2 3 4 5
These two 8-pin modular jacks are used for jumping the A or B inputs together to provide additional inputs.
T1 IN
AB
UNTERM
26 50
A
251
Alarm / Power
TERM
B
Rear Panel Description
Alarm /
Power Pinout
Pin Function
148 VDCReturn 2 Alarm Common
48 VDC
180 mA
61
3 -48 VDC 4 Frame Ground 5 Normally Close d 6 Normally Open
2
T1 IN:
These two 8-pin modular jacks are used for the T1 input signal as well as the output of each input. These 2 connectors output AIS
with no input.
3
Terminate/Unterminate:
These two slide switches are used for setting the A or B input. They are recessed and can be moved with a screwdriver. Terminate is used when the expansion connector is not used. Unterminate is used when the expansion connector is daisy chained.
4
T1 Broadcast Port:
This 50-pin female connector is used for the expanded outputs of either the A or B inputs. Refer to the pinout table
below.
5
Alarm:
This 6-pin connector is used as follows for the alarm connection. Th e alarm connection is made on pins 2 and 5 to operate in a normally closed mode (NC - opens on alarm) or on pins 2 and 6 to operate in a normally open mode (NO - closes on alarm). The contacts are rated at 1.0 Amp AC or 1.0 Amp DC. 18- to 20-gauge wire is recommended.
5
Power:
This 6-pin connector i s used as follows for the power connection. The unit requires a -48 VDC power source that is capable of supplying 50 mA current. Connect a chassis ground lead to pin 4. Connect the -48 VDC lead to pin 3. Connect the return lead to pin 1. 18­to 20-gauge wire is recommended.
T1 Broadcast Port Pinout
Tip Ring Function
1 26 Output # 1 2 27 Output # 2 3 28 Output # 3 4 29 Output # 4 5 30 Output # 5 6 31 Output # 6 7 32 Output # 7 8 33 Output # 8
9 34 Output # 9 10 35 Output # 10 11 36 Output # 11 12 37 Output # 12 13 38 Output # 13
Tip Ring Function
14 39 Output # 14 15 40 Not Used 16 41 Not Used 17 42 Not Used 18 43 Not Used 19 44 Not Used 20 45 Not Used 21 46 Not Used 22 47 Not Used 23 48 Not Used 24 49 Not Used 25 50 Frame Gnd
Expand / T1 In Pinout
Pin EXPAND T1 IN
1 Data Out Data In 2 Data Out Data In 3 Not Used Not Used 4 Not Used Data Out 5 Not Used Data Out 6 Not Used Not Used 7 Chassis Gnd Chassis Gnd 8 Chassis Gnd Chassis Gnd