Verilink 1050 Installation Guide

®
TRANSPORT
1050 APS Chassis
Configuration Guide
Part Number 45-00006
1050 Chassis Front View
Rev 2.00
ALARM &
POWER
N
O 1234
CHASSIS
ADDRESS
POWER
NORMAL
SILENT
ACO
ALARM
FUSE
ALARM
A
3 AMP
GMT
B
TxPORT
1250
1 2 3 –
STATUS
PATH A
PATH B
LOS
TxPORT
1557
STATUS
PATH A
PATH B
LOS
TxPORT
1557
STATUS
PATH A
PATH B
LOS
TxPORT
1557
STATUS
PATH A
PATH B
LOS
TxPORT
1557
STATUS
PATH A
PATH B
LOS
TxPORT
1557
STATUS
PATH A
PATH B
LOS
TxPORT
1557
STATUS
PATH A
PATH B
LOS
TxPORT
1557
STATUS
PATH A
PATH B
LOS
TxPORT
1557
STATUS
PATH A
PATH B
LOS
TxPORT
1557
STATUS
PATH A
PATH B
LOS
TxPORT
1557
STATUS
PATH A
PATH B
LOS
TxPORT
1557
STATUS
PATH A
PATH B
LOS
TxPORT
1557
STATUS
PATH A
PATH B
LOS
TxPORT
1557
STATUS
PATH A
PATH B
LOS
TxPORT
1557
Alarm and
Power Card
(Slot 0)
1557 AP S Cards or 1554 DLIU Cards (Slots 1 - 14)
Connections
Refer to the diagram on the reverse side for the locations of the following connectors.
Equipment: Primary (Path A) and Secondary (Path B) equipment con­nection to the APS system may be made through standard 0.045 gauge wire wrap pins or through 50- pin female miniature ribbon type connec­tors. Equipment side sign als for all 14 APS cards are gathe red on a single 50 -pin female miniature ribbon type co nnector for each path. Input con­nectors are labeled J6 and J9. Output connectors are labeled J7 and J8.
Network: Primary (Path A) and Secondary (Path B) net work connection to the APS system may b e made through st andard 0.045 g auge wire wrap pins or through 50 -pin female miniatu re ribbon type conn ectors. Network side signals for all 14 APS cards are gathered on a sing le 50 -p in female miniature ribbon type connector for each path. Input connectors are labeled J1 and J4. Output connectors are labeled J2 and J3.
NMS Bus: The TxPORT 1559 APS Manager (APSM) is used to remotely configure, control, and monitor the 1557 cards mounted in the APS chassis as well as 1558 APS CPE installations. The manager communicates to the
Rack and Mounting Hardware
1557 cards through a bus interface (P1 Bus In and P2 Bus Out). The 1559 APSM can communicate with u p to 8 chassis (or up to 112 APS cards). The OUT port (P2) is used only to connect one chassis to the next in a ‘daisy-chain’ fashion. It is an output only port.
Alarm: Conn ector J5 provides relay contacts for conn ection to a remote indicating device. The alarm output of the Alarm and Power Card is also available on terminal block TB1 and on the wire wrap connectors of the Alarm and Power Card.
Power: The APS Chassis must be powered by an external -48 VDC source capable of d elivering 2-ampere maximu m current. The ch assis can accommodate two - 48 VDC power sources if redundancy is desired. Con­nect a ground lead to TB1-10 (Chassis Ground). C onnect the o ther end of the ground lead to a solid chassi s ground. Conn ect the prim ary power sup­ply return lead to TB1-2. If a second ary power supply is used, connect it s return lead to TB1- 1. Connect the primary power supply 48 VDC lead to TB1-4. If a secondar y power supply is used, connect it s 48 VDC lead to TB1-3. 18- or 20-gauge wire is recommended for power connections.
1050 Chassis Rear View
21
36 35
C14
J1 - FACILITY B IN
26
J2 - FA CI LITY B OUT
26
21
36 35
21
36 35
C13
C12
J3 - FACILITY A OUT
26
J4 - FA CI LITY A IN
26
(1-14)
(1-14)
(1-14)
(1-14)
50
251
50
251
21
36 35
C11
50
251
50
251
21
36 35
C10
P1 P2
IN-TVIEW-OUT
14 14
J5 - REMOTE ALARMS/CONTROL
21
36 35
C9
21
36 35
C8
21
36 35
C7
21
36 35
C6
TB1
10987654321
Alarm NC
Alarm NO
-48 VDC A
Alarm Com
Force Switch
Chassis Ground
Force Switch Com
-48 VDC B
-48 VDC Return A
21
36 35
C5
-48 VDC Return B
J6 - EQUIPMENT B IN
(1-14)
25
J7 - EQUIPMENT B OUT
21
36 35
C4
J8 - EQUIPMENT A OUT
(1-14)
25
21
36 35
C3
(1-14)
25
J9 - EQUIPMENT A IN
(1-14)
25
21
36 35
C2
1
2650
1
2650
21
36 35
C1
1
2650
1
2650
21
36 35
C15
0.045 Gauge Wire Wrap
Pins
C1 - C14 Connection
Function Tip Ring
Network Out - Secondary 1 2 Network Out - Primary 3 4 Equipment Out - Secondary 5 6 Equipment Out - P rimary 7 8 Network In - Secondary 9 10 Network In - Primary 11 12 Equipment In - Secondary 13 14 Equipment In - Primary 15 16 NMS In / Out 29 / 30
J1-J4 and J6-J9 Connection
Circuit Tip Ring
1 1 26 2 2 27 3 3 28 4 4 29 5 5 30 6 6 31 7 7 32 8 8 33
9 9 34 10 10 35 11 11 36 12 12 37 13 13 38 14 14 39
C15 Connections NMS Connections
Function Pin
-48 VDC - Primary 1 48 V RTN 5
-48 VDC - Secondary 9
Alarm NC 18 Alarm NO 19 Alarm Common 20 NMS In 29 NMS Out 30 NMS Ground 34
Pin NMS In NMS Out
1 Ground Ground 2 Data Out Data Out 3DataIn Open 4 Ground Ground
J5 Connection
Alarm Trip NO/NC Common
1 1 26 2 2 27 3 3 28 4 4 29 5 5 30 6 6 31 7 7 32 8 8 33
9 9 34 10 10 35 11 11 36 12 12 37 13 13 38 14 14 39
TxPOR T Custom er Service
127 Jetplex Circle
Madison, Alabama 35758
Customer Service Returns:
800-926-0085, ext. 227
Product Technical Support:
(8 – 5 Centr al Time)
Emergency After Hours:
E-Mail (Internet Address):
support@txp ort.com
®
TRANSPORT
800-285-2755 205-772-3770
800-285-2755