TRANSPORT
®
1041 Redundant Power Shelf
Configuration Guide
Part Number 45-00070
Rev 1.00
Installation
The TxPORT 1041 Redundant Power Supply
Shelf is designed to hold either one or two
power supplies confor ming to industr y standard
Type 400 mechanics (such as TxPORT’s model
number 9-1000-48V-2). The shelf provides
wiring from the power supply connectors to an
AC power input. Fused DC output terminals are
located on the rear of the shelf.
Rack mounting ears are available for installation
into standard 19" or 23" racks. To install the ears
onto the 1041, use the 2 tapped scr ew holes on
1041 POWER SUPPLY
P/S A P/S B
each side of the 10 41. To install the 1041 in to a
rack, insert two screws through both the left and
right mountin g brackets.
The 1041 shelf has two slots acces sible from the
front in which the power supplies are inserted. To
install the power supplies, first remove the front
panel by removing the two screws. Then insert
each supply thro ugh o ne of the two slo ts unt il the
card is firmly seated to the rear connector.
AC power is applied to the unit by inserting the
power cord into a 110 V outlet. DC power is then
derived from the unit by connection to the rear
panel terminal strips.
Front View
ALARM
CUTOFF
ACO
ALARM
WARNING: Use caution when installing or
removing the power supplies. 110 volts AC is
present on the inside rear circuitry.
When installing a power supply with AC power
connected, the ‘Alarm’ LED will light for about
10 seconds while the unit stabilizes (un dergoes a
soft start). The green power indicator then lights
if the unit is operating normally.
WARNING: When replacing one of the power
supplies while in service, wait at least 10 minutes after removing the supply before replacing
the new one. This prevents contact arcing of the
edge connector.
®
TRANSPORT
2 43 6 7
1
1
Mounting Bracket:
2
Panel Screw:
3
Power Indicator:
4
Power Supply:
5
6
7
This yellow LED lights if the Alarm Cut Off switch is placed in the upper ‘ON’ position, in dic atin g th at the alarm relay contac ts are disabled.
ACO:
Alarm:
This red LED lights if any fuse opens or if one of the redundant power supplies fails (this can be cleared by removing the supply).
Alarm Cutoff:
Rack mounting ears are available for installation into standard 19" or 23" racks.
These two screws are used to mount the front panel to the 1041 housing.
This green indicator lights when the 1041 power shelf has 110 VAC applied to it and operation is normal.
Power supplies ‘P/S A’ and ‘P/S B’ are inserted into these 2 openings.
This switch controls the alarm relay contacts. If it is placed in the upper ‘ON’ position, the alarm relay circuitry is deactivated.
Specifications
Input Voltage: 115 VAC (± 20 V)
Output Voltage: 48 VDC (± 2 V)
Output Current: 2 A maximum, 50 mA minimum
Power Input: 113 W maximum
Heat Generation: 390 BTU
Efficiency: 80%
Alarm Contact 1.0 A @ 220 VDC
Ratings: 1.0 A @ 250 VAC
5
Ordering Numbers
The part number for the 10 41 Shelf
(dual 400 plug - in shel f) without any
power supplies is:
F-1041-000 --110
The part number for the 48 VDC
power supply is:
9- 1000-48V-2
Mechanical: 16.5" W, 1.625" H, 6" D
4.5 pounds with no power supplies
7 pounds with two power supplies

1041 Power Shelf Rear Panel
115 VAC
2.0 A
60 HZ
FUSE RATING
3.0 A 125 V
GND NC C NO
–
AB
F1
2 4 5 6
+
48 VDC
2A
31 7
ALARM
CONTACTS
FUSE RATING
.25 A 125 V
12345678
F2
1
1 8 RETURN
Rear Panel Description
1
AC Power Cord:
2
3
Fuse F1:
48 VDC:
Fuses A and B protect the main power feeds.
The three screw terminals on the left are used to connect a -48 VDC load to the mai n feeds.
Alarm Contacts:
4
configured as normally closed (NC) or normally open (NO). NO and NC refer to the contact’s relationship to the common (C)
contact under a ‘no alarms’ condition.
5
Fuse F2:
Fuses 1 through 8 protect the multiple load terminal strip with a rating of 0.25 A each.
This cord can be connected to any available 110 V outlet.
The three isolated contacts on the right permit connecti on to a remote indicating device. The contacts may be
8 -48 VDC
6
7
-48 VDC:
Return:
These 8 screw terminals are used to connect multiple 0.25 A loads to the main feeds.
These 8 screw terminals are used as returns for the multiple feeds.
Simplified Schematic
+
P/S A
-48 V
F1-A
••
P/S B
-48 V
3 A
F1-B
3 A
GND
–
F2
F22F2
1
RETURN
21 345678
-48 VDC
21 345678
F2
F2
F2
3
4
5
6
F27F2
8
8 fuses at 0.25 A each
TRANSPORT
TxPORT Customer Service
127 Jetplex Circle
Madison, Ala ba m a 35 758
Customer Service Returns:
800-926-0085, ext. 227
Product Technical Sup-
port:
(8 – 5 Central Time)
800-285-2755 or
205-772-3770
Emergency After Hours:
800-285-2755
E-Mail (Internet Address):
support@txport.com
®