Verilink 1024 Installation Guide

1024 Chassis
Configuration Guide
45-00123
3.0
The Verilink 1024 chassis is designed to hold from one to twenty-fou r modules.
The front view figure shows the chassis with brack­ets for a 19-inch rack. The rear panel NMS and pow­er connections are described on the reverse side.
Each module inte rf ac es the c ha ssis bac kpl ane b oar d through two card connectors. With these connectors, each module receives a 48 VDC power source and exchanges control signals with the rear panel chassis connectors. The chas sis cont ains no ac tive compo­nents. Rack mounting bracket s are reversible for sta ndard 19- and 23-inch racks. To install the chassis in a rack, insert two screws through both the left and the right mounting b rackets. Please note: In order to
meet GR-1089 grounding requirements, the chassis must be installed using t hread-forming screws with external tooth lock washers.
CHASSIS
TRANSPORT
1024
Specifications
Dimensions: 17.2" W, 7" H, 10.5" D, Weight: 9.5 pounds Operating Temp: 0° to 50° C (32° to 122°F) Storage Temp: 20° to 85° C (4° to 185°F) Humidity: 95% max (non-condensing )
Caution: The 3002 is designed for convec­tion cooling. Mount the 1024 with a top and bottom clearance of at least 1¾ inches.
Verilink 1024 Chassis Front View
Industry Listings
FCC Compliance: Part 15 Class A
Subpart B U.S. Safety: UL 1950 3rd Edition Canadian Safety: CSA C22.2 No. 950-95
242322212019181716151413121110987654321
NOTICE:
If your Verilink 1024 Chassis has a top assembly number of F-1024-000--120, metal dividers are installed in slots 5, 10, 15 and 20. Removal of these dividers voids NEBS compliance!
NMS Connections
The NMS ports are used to connect the chassis into the Verilink EM8100A element mana ger. Within the chassis, each unit is ph ysic ally co nnecte d to the next unit in a daisy-chain fashion. Two 6-pin mod­ular connectors are provided for bot h the A side and the B side. Each unit in the NMS chain must have a unique ad­dress. All units in the chain must use the same NMS bit rate.
Pin NMS In (P5) NMS Out (P4)
1 Not Used Not Used 2 Signa l Gnd Signal Gnd 3 Data Out Data Out 4 Data In Not Used 5 Signa l Gnd Signal Gnd 6 Not Used Not Used
Power Connections
The chassis is designed with two power buses con­nected to TB1 (te rminal block 1). The A bus feeds the slots 1 through 12 . The B bus feeds slots 13 through 24. Connect a Frame Gr ound lea d (18- to 20 - gaug e wire) to pin 2 before applying power to the unit. Connect the other end of this lead to an ap­propriate frame ground .
NOTE: The maximum current draw of a fully loaded chassis i s 4 amperes. The Verilink 1042 power shelf can su pply a ma x­imum of 4 amperes (refer to the c onfigura­tion guide for specifications). Ensure that the proper fuse size is used.
OUTPUT INPUT
Verilink 1024 Chassis Rear View
+48VDC IN A CHASSIS GND
-48VDC IN A
-48VDC IN B SIGNAL GND +48VDC IN B
TB1
OUTPUT INPUT
+48VDC IN A CHASSIS GND
-48VDC IN A
-48VDC IN B SIGNAL GND +48VDC IN B
TB1
123456789101112131415161718192021222324