Verilink 1024 Installation Guide

Page 1
1024 Chassis
Configuration Guide
45-00123
3.0
The Verilink 1024 chassis is designed to hold from one to twenty-fou r modules.
The front view figure shows the chassis with brack­ets for a 19-inch rack. The rear panel NMS and pow­er connections are described on the reverse side.
Each module inte rf ac es the c ha ssis bac kpl ane b oar d through two card connectors. With these connectors, each module receives a 48 VDC power source and exchanges control signals with the rear panel chassis connectors. The chas sis cont ains no ac tive compo­nents. Rack mounting bracket s are reversible for sta ndard 19- and 23-inch racks. To install the chassis in a rack, insert two screws through both the left and the right mounting b rackets. Please note: In order to
meet GR-1089 grounding requirements, the chassis must be installed using t hread-forming screws with external tooth lock washers.
CHASSIS
TRANSPORT
1024
Specifications
Dimensions: 17.2" W, 7" H, 10.5" D, Weight: 9.5 pounds Operating Temp: 0° to 50° C (32° to 122°F) Storage Temp: 20° to 85° C (4° to 185°F) Humidity: 95% max (non-condensing )
Caution: The 3002 is designed for convec­tion cooling. Mount the 1024 with a top and bottom clearance of at least 1¾ inches.
Verilink 1024 Chassis Front View
Industry Listings
FCC Compliance: Part 15 Class A
Subpart B U.S. Safety: UL 1950 3rd Edition Canadian Safety: CSA C22.2 No. 950-95
242322212019181716151413121110987654321
NOTICE:
If your Verilink 1024 Chassis has a top assembly number of F-1024-000--120, metal dividers are installed in slots 5, 10, 15 and 20. Removal of these dividers voids NEBS compliance!
Page 2
NMS Connections
The NMS ports are used to connect the chassis into the Verilink EM8100A element mana ger. Within the chassis, each unit is ph ysic ally co nnecte d to the next unit in a daisy-chain fashion. Two 6-pin mod­ular connectors are provided for bot h the A side and the B side. Each unit in the NMS chain must have a unique ad­dress. All units in the chain must use the same NMS bit rate.
Pin NMS In (P5) NMS Out (P4)
1 Not Used Not Used 2 Signa l Gnd Signal Gnd 3 Data Out Data Out 4 Data In Not Used 5 Signa l Gnd Signal Gnd 6 Not Used Not Used
Power Connections
The chassis is designed with two power buses con­nected to TB1 (te rminal block 1). The A bus feeds the slots 1 through 12 . The B bus feeds slots 13 through 24. Connect a Frame Gr ound lea d (18- to 20 - gaug e wire) to pin 2 before applying power to the unit. Connect the other end of this lead to an ap­propriate frame ground .
NOTE: The maximum current draw of a fully loaded chassis i s 4 amperes. The Verilink 1042 power shelf can su pply a ma x­imum of 4 amperes (refer to the c onfigura­tion guide for specifications). Ensure that the proper fuse size is used.
OUTPUT INPUT
Verilink 1024 Chassis Rear View
+48VDC IN A CHASSIS GND
-48VDC IN A
-48VDC IN B SIGNAL GND +48VDC IN B
TB1
OUTPUT INPUT
+48VDC IN A CHASSIS GND
-48VDC IN A
-48VDC IN B SIGNAL GND +48VDC IN B
TB1
123456789101112131415161718192021222324
145 Baytech Drive
San Jose, California 95134
127 Jetplex Circle
Madison, Alabama 35758
(800) 837-4546
www.verilink.com
FAX-On-Demand
(800) 957-5465
Technical Assistance Center
(800) 285-2755
Loading...