VeriFone Indoor VeriPASS Installation Manual

Page 1
VeriFone Indoor VeriPASS
Terminal Installation Guide
P/N: 55295 Revision A
Page 2
VeriFone Indoor VeriPASS Terminal Installation Guide
August 15, 1999
VeriFone
, a division of Hewlett-Packard 4988 Great America Parkway Santa Clara, CA 95054-1200 Telephone: 408-496-0444 http://www.verifone.com
Printed in the United States of America.
© 1999 by Ver iFone, a divisio n o f Hewlett- Packar d All rights reserved.
No part of this publication covered by the copyrights herein may be reproduced or copied in any form or by any means — graphic, electronic, or mechanical, including photocopying, taping, or information storage and retrieval systems — without written permission of the publisher.
The content of this document is subject to change without notice. The information contained herein does not represent a commitment on the part of VeriFone, a division of Hewlett-Packard.
Publications are not stocked at the address given above. Requests for VeriFone publications should be made to your VeriFone representative.
VeriFone is a registered trademark of Hewlett-Packard Company. All other products mentioned in this manual are trademarks or registered trademarks of their respective owners.
Page 3
VeriFone Indoor VeriPASS
Terminal Installation Guide
Revision History
Revision Date Comments
A August 15, 1999 Initial release of software
and documentation.
Page 4
FCC Compliance
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installatio n. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment doe s cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Safety Instructions
Read all instructions contained in this guide before making any equipment connections.
Save these instructions for later use.
Unplug the unit before servicing or cleaning. Do not use liquid or aerosol cleaners. Use only a damp cloth for cleaning.
Page 5
Do not use any attachments not specifically reco mmended by VeriFone as they may result in the risk of fire, electric shock, or injury to persons.
Do not use the unit near water.
Do not place the unit on an unstable cart, stand, or table. The unit may fall, causing serious personal injury and/or damage to the equipment.
Page 6
Page 7
Contents
1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . .1
2. Unpacking. . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Installation Procedures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Equipment Power Up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
4. Specifications. . . . . . . . . . . . . . . . . . . . . . . . .9
Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Operating Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Service and Repair. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Cleaning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Contents
i
Page 8
Contents
ii
Page 9
1
This document provides the information necessary to install your VeriFone Indoor VeriPASS Terminal System.
mobilind.wmf 125%
VeriFone Indoor VeriPASS Terminal
Introduction
Everest
Base Cable
Ferrite Bead
Base Unit
Cable Tie
Multicable
Installation Manual
Optional Power Supply* (VFI P/N: 04250 -05)
* Optional Power Supply not required
when used with a Ruby SuperSystem
The VeriFone Indoor VeriP ASS T er minal System is a self-contained device, when properly installed, becomes an integral part of the Ruby SuperSystem. It has the ability to read a retail customer’ s tag when placed near an antenna mounted on the face of the equipment. Information from the tag is processed and transferred to the Ruby.
Introduction
1
Page 10
Introduction
2
Page 11
2
Carefully inspect the shipping carton and its contents for any damage that may have occurred during shipment. If anything appears damaged, immediately file a claim with the shipping company or carrier and notify your VeriFone representative.
Warning: Never use damaged equipment. A shock or fire
Remove the following items from the shipping carton:
Unpacking
hazard may exist if equipment is energized in a damaged condition.
Ve ri Fone Indoor VeriPASS Terminal Unit with attached Mulitcable
Power Su pply (optional)
Ferrite Bead
Remove any protective plastic wrapping from the components and place the components on a table or countertop.
Retain the shipping carton and any packing material in case it is necessary to move components from one location to another or to return the equipment for service.
Unpacking
3
Page 12
Unpacking
4
Page 13
3
Unpack equipment in accordance with instructions listed in Chapter
2.
Wa rning: To reduce the risk of fire, do not place this unit near
When selecting a location for your VeriFone Indoor VeriPASS Te rminal equipme nt, avoid areas having:
Installation
any heat producing source.
Direct sunlight or objects that produce heat. Moist areas. Excessive dust. Electrical “noise” or devices that cause excessive voltage
vari ations such as ai r condit ioner s, fan s, or high fr equenc y security systems.
Installation Procedures
Note: If not present, install the Ferrite Bead on the
Multicable, as close to the Base Unit as possible. This filters out any interference generated by the equipment. Refer to the diagram on page 1 for location.
Use the following procedure to install and power up the VeriFone Indoor VeriPASS Terminal in a VFI Ruby environment.
Installation
5
Page 14
1. Ensure power to the Ruby is disconnected
2. Place the unit close to the Ruby.
3. Uncoil the Multicable and ensure that it does not kink or is not placed under heavy equipment.
4. Mount the unit on a custom stand, if applicable.
5. Insert the RS232 cable connector from the Ruby into the Multicable jack labeled PORT 1.
6. Apply power to the Ruby.
Ferrite Bead
Ver iFone Indoor VeriPASS Terminal
Multicable
PORT 1
Ruby
Com Port*
Seri al C a ble
P/N: 13836-01
* Consult VASC Service Manual to determine the correct com port for your application.
Equipment Power Up
The Verifone VeriPASS Terminal is powered from the Ruby T erm inal through a serial cable. This feature eliminates the need for an optional power supply.
Note: The VeriPASS Terminal may be powered by an
optional external power supply (VeriFone P/N: 04250-05).
Use the following procedures to power up the VeriFone Indoor Ve riPASS Terminal unit using the optional power supply:
Installation
6
Page 15
1. Insert the Power Cable connector into the Multicable jack labeled POWER.
Note: Use a locally available cable tie to secure the Power
Cable jack to the Multicable connector as shown in the diagram on page 1. This configurati on maintains the integrity of the connection and provides additional connection security.
Warning: When the optional Pow e r Supply is plugged into the
AC power outlet, voltage is immediately available to the VeriFone Indoor VeriPASS Terminal. Avoid handling the exposed power cable conne ctor.
Note: The AC power outlet should be easily accessible
should the user desire quick power disconnect.
2. Connect the Power Supply to the AC power outlet or appropriately configured power connector.
3. Verify the customer display is activated.
4. Verify the logo illuminates momentarily when power is applied.
5. Verify the display is illuminated and the display is activated.
Warning: To turn off your VeriFone Indoor VeriPASS Terminal,
always unplug the power supply from the AC power outlet first. This eliminates the presence of voltage at the Multicable power receptacle and the potential shock hazard.
Installation
7
Page 16
Installation
8
Page 17
4
Specifications
Power Requirements
Input: 120VAC 60Hz 18 W
Output: 12VDC 1000 mA
Operating Environment
Temperature: 0 to 40oC (32 to 104oF)
Humidity: 20% to 90%, noncondensing
Service and Repair
Do not, under any circumstances, attempt to repair, service, or adjust your VeriFone Ind oor VeriPASS Terminal equipment. I f you have any problems with your unit, contact your VeriFone Authorized Service Contractor.
Note: Changes or modifications not expressly approved by
VeriFone could void the user's authority to operate this equipment.
Specifications
9
Page 18
Cleaning
Warning: Disconnect power before cleaning this equipment.
Routine cleaning can be accomplished by removing dust or dirt with a clean, damp cloth and mild soap or detergent. Use a cloth dampened with alcohol for more stubborn stains.
Warning: Never use thinner, trichloroethylene, or ketone based
solvents to clean this equipment or cabling as they may deteriorate plastic parts.
Specifications
10