![](/html/ce/ce66/ce669a7f163defd3988ee76574116c62b6bafbc207fb9aec42b47e42ab178105/bg3.png)
TABLE OF CONTENTS
ET8K(X) INSTRUCTION MANUAL
SECTION 100 DESCRIPTION & SPECIFICATIONS
21821 INSTALLATION DIMENSIONS - ET8K(X)
21592 21571 BASE MOUNTING DIMENSIONS
21701 CAPACITY CHART - ET8K(X)
16941 TYPICAL REINFORCEMENT FOR MOUNTING CRANE ON TOP OF SERVICE BODY
21594 INSTALLATION DRAWING - 21571 MOUNTING PEDESTAL
22686 INSTALLATION DRAWING - 18500-CD MANUAL OUTRIGGER
13509 INSTALLATION DIMENSIONS - 13500 MANUAL OUTRIGGER SIDE BRACKET
I23961 INSTALLATION DIMENSIONS - 23961 MANUAL OUTRIGGER SIDE BRACKET
I23960 INSTALLATION DIMENSIONS - 23960 MANUAL OUTRIGGER FOLD AWAY TYPE
SECTION 150 SAFETY
850711 SAFETY & HAZARDS - GENERAL
15394 VEHICLE & CRANE ELECTRICAL HAZARD INFORMATION
21822 DECAL PLACEMENT
21353 SAFETY DECALS
21354 DECALS FOR ET CRANES
21362 MISCELLANEOUS DECALS - ET8/12K(X)
21825 MODEL AND CAPACITY DECALS - ET8K(X)
SECTION 200 INSTALLATION
711105 CABLE & BATTERY REQUIREMENTS - ET AND HT CRANES
15660 BATTERY CABLE INSTALLATION DRAWING
20906-8 ET8K, ET8KX STABILITY TEST
20907 STABILITY CHART
900530a ET8/10/12K(X) OPERATION & MAINTENANCE INSTRUCTIONS (PAGE 1 OF 4)
900530b ET8/10/12K(X) OPERATION & MAINTENANCE INSTRUCTIONS (PAGE 2 OF 4)
900530c ET8/10/12K(X) OPERATION & MAINTENANCE INSTRUCTIONS (PAGE 3 OF 4)
22245 WIRE ROPE INSTALLATION DRAWING
20872 ADJUSTABLE BOOM REST
SECTION 300 MAINTENANCE & SERVICE
21306 ET8/12/18K(X) OPERATION & MAINTENANCE INSTRUCTIONS (PAGE 4 OF 4)
19963 MINIMUM VOLTAGE TEST
23225 WIREROPE AND HOOK SPECIFICATIONS
SECTION 400 REPLACEMENT PARTS
21826 ET8K(X) REPLACEMENT PARTS DRAWING
21827 ET8K(X) REPLACEMENT PARTS LIST
21828 ET8K(X) REPLACEMENT FASTENER LIST
21600 21515 ELECTRICAL COMPONENT ASSEMBLY
21737 ELECTRICAL SYSTEM SCHEMATIC - ET8K
21658 ELECTRICAL SYSTEM SCHEMATIC - ET8/12KX
21654 HYDRAULIC SYSTEM COMPONENTS REPLACEMENT PARTS DRAWING
21602 HYDRAULIC SYSTEM SCHEMATIC - ET12KX
21584 16770 SWIVEL TERMINAL ASSEMBLY REPLACEMENT PARTS
19791 REPLACEMENT PARTS - 3 FUNCTION PENDANT CONTROL
20161 REPLACEMENT PARTS - 4 FUNCTION PENDANT CONTROL
21834 21729 BOOM ASSEMBLY REPLACEMENT PARTS
21829 21719 BOOM ASSEMBLY REPLACEMENT PARTS
21741 21556 WINCH REPLACEMENT PARTS DRAWING & LIST
22689 REPLACEMENT PARTS - 18500-CD MANUAL OUTRIGGER
21833 FIELD SERVICE LABEL KIT
SECTION
-
MFG., INC.
CINCINNATI, OHIO
TITLE
TABLE OF CONTENTS
ET8K(X)
DATE
9-1-11E
SUPERCEDES
7-31-08D
21820
![](/html/ce/ce66/ce669a7f163defd3988ee76574116c62b6bafbc207fb9aec42b47e42ab178105/bg10.png)
CRANE SAFETY AND HAZARDS
ET CRANES
CAUTIONS
1. INSPECT VEHICLE AND CRANE, INCLUDING OPERATION, PRIOR TO USE DAILY.
2. DO NOT USE THIS EQUIPMENT EXCEPT ON SOLID, LEVEL SURFACE WITH CRANE MOUNTED ON
FACTORY-RECOMMENDED TRUCK.
3. BEFORE OPERATING THE CRANE, REFER TO MAXIMUM LOAD (CAPACITY) CHART ON CRANE FOR
OPERATING (LOAD) LIMITATIONS.
4. DO NOT OPERATE, WALK, OR STAND BENEATH BOOM OR A SUSPENDED LOAD.
5. ATTACH PENDANT CORD SUPPORT SNAP TO ATTACHMENT POINT BEFORE PLUGGING IN PENDANT, IF
SO EQUIPPED.
6. UNPLUG PENDANT AND SHUT OFF MASTER DISCONNECT SWITCH WHEN CRANE NOT IN USE.
7. FOR TRAVEL, BOOM MUST BE IN STOWED POSITION.
DANGER
• THIS CRANE IS NOT A PASSENGER LIFT
• IT IS NOT DESIGNED OR INTENDED TO BE USED TO LIFT, SUPPORT, OR OTHERWISE TRANSPORT
PERSONNEL.
YOU MUST NOT OPERATE THIS CRANE UNLESS
1. YOU HAVE BEEN TRAINED IN THE SAFE OPERATION OF THIS CRANE
AND
2. YOU KNOW AND FOLLOW THE SAFETY AND OPERATING RECOMMENDATIONS CONTAINED IN THE
MANUFACTURER'S MANUALS, YOUR EMPLOYER'S WORK RULES, AND APPLICABLE GOVERNMENT
REGULATIONS. AN UNTRAINED OPERATOR SUBJECTS HIMSELF AND OTHERS TO DEATH OR SERIOUS
INJURY.
ELECTROCUTION HAZARD
• THIS MACHINE IS NOT INSULATED.
• MAINTAIN SAFE CLEARANCES FROM ELECTRICAL LINES AND APPARATUS.
• YOU MUST ALLOW FOR BOOM SWAY, ROCK OR SAG, AND ELECTRICAL LINE AND LOADLINE
SWAYING.
• THIS LIFTING DEVICE DOES NOT PROVIDE PROTECTION FROM CONTACT WITH OR PROXIMITY TO AN
ELECTRICALLY CHARGED CONDUCTOR.
• YOU MUST MAINTAIN A CLEARANCE OF AT LEAST 10 FEET BETWEEN ANY PART OF THE CRANE,
LOADLINE, OR LOAD, AND ANY ELECTRICAL LINE OR APPARATUS CARRYING UP TO 50,000 VOLTS.
ADDITIONAL CLEARANCE IS REQUIRED FOR VOLTAGES IN EXCESS OF 50,000 VOLTS. REFER TO
DRAWING 15394 FOR ADDITIONAL INFORMATION.
• DEATH OR SERIOUS INJURY WILL RESULT FROM CONTACT OR INADEQUATE CLEARANCE.
MFG., INC.
CINCINNATI, OHIO
TITLE
INSTALLATION DWG
ELECTRIC CRANES
DATE
4-18-08H
SUPERCEDES
7-29-03G
SECTION
C150
850711