Vents-us Quietline User Manual

AXIAL FAN User’s manual
www.vents-us.com
Quietline (120V/60Hz)
EN
2
EN
CONTENTS
Timer adjustment .............................................................................................................................................................................................................................. 11
Technical maintenance ................................................................................................................................................................................................................... 12
Storage and transportation regulations ............................................................................................................................................................................... 12
Manufacturer’s warranty ................................................................................................................................................................................................................ 13
3
EN
This user’s manual is a main operating document, intended for technical, maintenance, and operating staff.
The manual contains information about the purpose, technical details, operating principle, design, and installation of the Quietline unit and all of its modifications.
Technical and maintenance staff must have theoretical and practical training in the field of ventilation systems and should be able to work in accordance with workplace safety rules as well as construction norms and standards applicable in the territory of the country.
The information in this user’s manual was correct at the time of the document’s preparation.
The Company reserves the right to modify the technical characteristics, design, or configuration of its products at any time in order to incorporate the latest technological developments.
No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means in any information search system or translated into any language in any form without the prior written permission of the Company.
READ THE USER’S MANUAL CAREFULLY BEFORE PROCEEDING WITH INSTALLATION WORKS.
COMPLIANCE WITH THE MANUAL REQUIREMENTS ENSURES RELIABLE OPERATION AND LONG
SERVICE LIFE OF THE UNIT.
KEEP THE USER’S MANUAL AVAILABLE AS LONG AS YOU USE THE UNIT. YOU MAY NEED TO RE-
READ THE INFORMATION ON THE PRODUCT SERVICING.
READ AND SAVE THESE INSTRUCTIONS
4
EN
FOLLOW THE USER’S MANUAL REQUIREMENTS TO ENSURE DURABLE AND
TROUBLE-FREE OPERATION OF THE UNIT.
Disconnect the unit from power supply prior to any connection, servicing, maintenance, and repair operations.
Only qualied electricians with a work permit for electrical units up to 1000 V are allowed for installation and maintenance. The present user’s manual should be carefully read before beginning works.
• Single-phase power mains must comply with the acting local electrical norms and standards.
• Fixed electrical wiring must be equipped with an automatic circuit breaker.
• The unit must be connected to power mains through a QF automatic circuit breaker integrated into the fixed wiring system. The gap between the circuit breaker contacts on all poles must be not less than 3 mm. Check the unit for any visible damages of the impeller and the casing before starting installation. The casing internals must be free of any foreign objects that can damage the impeller blades.
• While mounting the unit, avoid compression of the casing! Deformation of the casing may result in the motor jam and noisy operation. Misuse of the unit and any unauthorised modifications are not allowed.
• Take steps to prevent ingress of smoke, carbon monoxide, and other combustion products into the room through open chimney flues or other fire-protection devices. Sufficient air supply must be provided for proper combustion and exhaust of gases through the chimney of fuel burning equipment to prevent back drafting. Transported air must not contain any dust or other solid
5
EN
impurities, sticky substances, or fibrous materials.
• Do not use the unit in a hazardous or explosive environment containing spirits, gasoline, insecticides, etc.
• Do not close or block the intake or extract vents in order to ensure the efficient air flow.
• Do not sit on the unit and do not put objects on it.
• The unit is allowed to be used by children aged from 8 years old and above and persons with reduced physical, sensory, or mental capabilities or no experience and knowledge provided that they have been given supervision or instruction regarding safe use of the unit and understand the risks involved.
• Do not allow children to play with the unit.
THE PRODUCT MUST BE DISPOSED SEPARATELY AT THE END OF ITS SERVICE LIFE.
DO NOT DISPOSE THE UNIT AS UNSORTED MUNICIPAL WASTE.
6
EN
DELIVERY SET
Fan 1 pc. Screws and dowels — 4 pcs. Screws for retaining cable clamp* — 2 pcs. Fixing bracket (applicable for Quietline-k) — 1 pc. Plastic screwdriver (only for the models with timer) — 1 pc. Cable clamp* 1 pc. User’s manual 1 pc. Packing box 1 pc. _____________ * - except for the models with a power cable
BRIEF DESCRIPTION
The products is an axial fan for exhaust or supply ventilation of small to medium-sized premises. The fan is designed for connection to 100, 125 and 150 mm air ducts.
MODIFICATIONS:
Quietline k: fan with a fixing bracket Quietline R: fan with a power cable and a plug Quietline T: fan with a controllable timer (for details please refer to electronic control logic) Quietline K: fan with a back valve to prevent back air flow during the fan standby Quietline DUO: fan with a two speed motor Quietline Extra: fan with a high-powered two speed motor Quietline Q: fan with a low-speed motor
Quietline 12: fan with a safe voltage 12V / 50 Hz motor
CAUTION! FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR
EXPLOSIVE MATERIALS AND VAPORS
7
EN
OPERATION GUIDELINES
The fan is rated for connection to AC single-phase 120 V/60 Hz power supply.
Quietline 12 and is rated for connection to 12 V, 50 Hz power mains directly or to AC 120 V, 60 Hz power supply via a step-down transformer, for example, TRF 120/12-25 (not included in the delivery set, available upon separate order). The fan is rated for operation at the ambient air temperature from +41 ˚F to +104˚F Ingress protection rating against access to hazardous parts and water ingress is IP X4. The fan requires no grounding.
WARNING: NOT SUITABLE FOR USE WITH SOLID-STATE SPEEDCONTROLS
AVERTISSEMENT : NE CONVIENT PAS A DES REGULATEURS DE VITESSE A SEMI-CONDUCTEURS.
8
EN
DESIGNATION KEY
Quietline k 100 Т X A
Colour
_ — white
Motor modication
_ - standard capacitor motor
DUO - fan with a two speed motor Extra - fan with a high-powered two speed motor Q - fan with a low-speed motor (с расщепленными полюсами) 12 - safety extra low voltage of 12 V/50 Hz
Additional options
T - fan with a controllable timer (for details please refer to electronic control logic) К - K - fan with a back valve to prevent back air flow during the fan standby Р - fan with a power cable and a plug
Outlet duct diameter [mm]
Built-in option
k- fan with a fixing bracket